← All vessels
R/V ANNIKA MARIE
Research Vessel · Research Ship class · Built 1970s · USCG Arctic District (CGD-A) · Other hulls named R/V ANNIKA MARIE
R/V ANNIKA MARIE is a 1977 research vessel. The Coast Guard has recorded 15 inspections since 1987, most recently in March 2026, along with 32 deficiencies.
Records from 1987 to 2026. Most recent: inspection, 17 March 2026.
- Built
- 1977
- Last inspected
- 17 March 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 32 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
581710
WYL6242
49144
Flag
UNITED STATES
367382590
Maury page id
psix-49144
Inspections, by type
The 15 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Research Ship class in Maury's sources begin in 1980.
Documentation record
Registered dimensions (L × B × D)41.9 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE & LAKE UNION · SEATTLE WA · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPRUDHOE BAY, AK
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itResearch Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDK9835MMSI 367382590 · active · voluntarily equipped · granted 27 July 2019, expires 27 July 2029
WYL6242MMSI 367382590 · expired · compulsorily equipped · granted 30 October 2008, cancelled 23 February 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 15
17 March 2026
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 8329493
24 June 2022
Administrative Inspection · ORV Letter of Designation
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 7486036
4 March 2020
ORV Letter of Designation · Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6939665
11 January 2018
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 6368227
10 March 2016
Administrative Inspection · ORV Letter of Designation
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 5831502
8 February 2010
Administrative Inspection · ORV Letter of Designation
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3703023
6 May 2008
Administrative Inspection
Administrative · Sector Western Alaska and U.S. Arctic · USCG Arctic District (CGD-A) · Activity 3200152
17 May 2006
Administrative Inspection
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 2651682
28 June 1999
Administrative
Administrative · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1121944
22 July 1998
Re-Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1386313
23 July 1997
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1453396
1 November 1996
Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 858966
20 July 1996
COI Inspection · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1425771
29 July 1994
Plan Review "T" Boat · COI Inspection · Inclining Experiment · Hull Examination
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1174648
13 July 1987
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1323216
Deficiency record · 32
Engineering
Issued 20 July 1996
Resolved
PROVIDE PROPER PIPING INSTALLATION WITH EMERGENCY SHUT OFF DEVICES FOR THE TWO CENTERLINE FUEL OIL TANKS IN ACCORDANCE WITH 46 CFR 182.20-30, 35, & 40. UNTIL ACCOMPLISHED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR THESE F.O. TANKS SHALL REMAIN OUT OF SERVICE.
Construction/Loadline
Issued 29 July 1994
Resolved
Make collision bulkhead watertight.
Electrical
Issued 29 July 1994
Resolved
Provide proper junction box for 12VDC terminal block in forward cabin overhead.
Electrical
Issued 29 July 1994
Resolved
Submit single line drawing of 110VAC electrical system. Do not operate 110VAC electrical system until drawing is approved. System is not to be operated until this item is corrected.
Lifesaving
Issued 29 July 1994
Resolved
Provide lifefloat or buoyant apparatus for at least 50% of total persons tobe allowed onboard.
Lifesaving
Issued 29 July 1994
Resolved
Provide 24 inch lifering with waterlight and lines.
Lifesaving
Issued 29 July 1994
Resolved
Mark lifejacket storage areas with number and type of lifejackets.
Fire Fighting
Issued 29 July 1994
Resolved
Service installed halon fire extinguisher in engine room or provide additional B-II portable fire extinguisher.
Fire Fighting
Issued 29 July 1994
Resolved
Provide approved brackets for 2 B-II fire extinguishers.
Construction/Loadline
Issued 29 July 1994
Resolved
Repair damaged engine powered bilge pump discharge hose.
Electrical
Issued 29 July 1994
Resolved
Replace 12VDC power supply cable for the refrigerator with cable of an approved type. Do not operate unit until the cable has been replaced.
Construction/Loadline
Issued 29 July 1994
Resolved
Provide accurate weight of solid ballast in hold space.
Navigation
Issued 29 July 1994
Resolved
Provide proper navigation lights configured as per the 72 COLREGS and 33 USC 1602 Annex I. Operation of the vessel is limited to daylight hours onlyuntil this item is corrected.
Engineering
Issued 29 July 1994
Resolved
Provide proper hangars for exhaust pipes on both main engines in engine room.
Accommodation/Occupational Safety
Issued 29 July 1994
Resolved
Provide additional upright support for rails around aft deck.
Engineering
Issued 29 July 1994
Resolved
Repair fuel leak on inlet side of oven fuel pump in engine room.
Documentation
Issued 29 July 1994
Resolved
Repaint name on bow of vessel.
Electrical
Issued 29 July 1994
Resolved
Properly insulate electrical connections throughout the vessel.
Lifesaving
Issued 29 July 1994
Resolved
Provide adequate mountings for hot potable water heater in hold space.
Construction/Loadline
Issued 29 July 1994
Resolved
Provide permanent closure on unused through hull fitting on transome.
Construction/Loadline
Issued 29 July 1994
Resolved
Provide weather tight seal on engine room deck hatch.
Construction/Loadline
Issued 29 July 1994
Resolved
Provide seavalve on engine powered bilge pump overboard discharge.
Lifesaving
Issued 29 July 1994
Resolved
Provide adequate mounting for potable water tanks in hold space.
Lifesaving
Issued 29 July 1994
Resolved
Provide waterlight for the buoyant apparatus. Operation of the vessel is limited to daylight only until this item has been corrected.
Construction/Loadline
Issued 29 July 1994
Resolved
Provide adequate bulkhead penetration seals between the engine room and thenext hold forward.
Electrical
Issued 29 July 1994
Resolved
Provide adequate ventilation to/from the battery area in the hold space.
Construction/Loadline
Issued 29 July 1994
Resolved
Secure ballast in hold space.
Electrical
Issued 29 July 1994
Resolved
Install correct size fuses in 12VDC electrical system as per 46 CFR 183. Fuses on circuits with AWG 14 size conductors shall be no larger than 15 amps.
Electrical
Issued 29 July 1994
Resolved
Replace voltmeter cable run with a cable of approved size and type.
Engineering
Issued 29 July 1994
Resolved
Provide 30X30 mesh or equivalent flame screens for all fuel tank vents.
Engineering
Issued 29 July 1994
Resolved
Provide metal safety bowls for RACOR fuel filters.
Construction/Loadline
Issued 29 July 1994
Resolved
Provide permanent closure on unused through hull fitting on starboard side just aft of main engine.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.