Records from 1999 to 2021. Most recent: inspection, 29 January 2021.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 25
29 January 2021
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7132899
17 November 2020
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 7096959
6 June 2019
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6710796
26 July 2018
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6491092
20 March 2018
COI Inspection · Drydock Exam
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6378873
26 April 2017
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 6133532
21 April 2016
Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 5914489
27 June 2012
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4358531
1 December 2011
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4207381
8 August 2011
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 4111149
18 February 2010
Administrative Inspection
Administrative · Marine Safety Unit Pittsburgh · USCG Heartland District (CGD-H) · Activity 3681827
18 April 2007
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2911653
18 April 2006
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2626750
17 May 2005
Re-Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2361463
11 May 2004
Re-Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 2064321
9 April 2003
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1770624
3 May 2002
Deficiency Check
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1612400
19 April 2002
Administrative Inspection
Administrative · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1606562
5 April 2002
Annual Inspection
Physical examination · Marine Safety Detachment Nashville · USCG Heartland District (CGD-H) · Activity 1601451
3 July 2001
Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 1067429
30 April 2001
Deficiency Check
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1064242
29 March 2001
COI Inspection · Hull Examination
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1433785
5 August 1999
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 824856
12 July 1999
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1386563
27 May 1999
Hull Examination · Initial Certification
Physical examination · MSO MEMPHIS · USCG Heartland District (CGD-H) · Activity 1437549
Engineering › Fuel Oil Service System › Piping
Issued 26 April 2017
Resolved
Fuel fill deck penetration fails to prevent fuel from entering the bilge in case of overfill.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2017
Resolved 26 April 2017
Resolution: Installed rubber bellow that prevents fuel from entering bilges.
Fire Fighting › Fire Bucket › Stenciling
Issued 27 June 2012
Resolved
Label fire buckets.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 10 July 2012
Resolution: Cleared.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 27 June 2012
Resolved
Replace expired items in first aid kit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 10 July 2012
Resolution: Cleared.
Construction/Loadline › Structures › Door
Issued 27 June 2012
Resolved
Replace broken spring on stbd side curtain.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 10 July 2012
Resolution: Cleared.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Mounting Bracket
Issued 27 June 2012
Resolved
Replace fire ext bracket with proper size.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 July 2012
Resolved 10 July 2012
Resolution: Cleared.
Documentation › Certificates/Documents › Stability Letter
Issued 1 December 2011
Resolved
Submitted CG-835 due to the dead line for submittal of the AAWPP certification of compliance the following vessels maximum persons allowed will be reduced to comply with the new 185lb AAWPP in accordance with CG 543 Policy Letter 11-03:
Allegheny Alice 25 Persons / Dahntahn Dottie 26 Persons / [name withheld] 24 Persons / Myrna Faith 21 Persons / Norside Nelly 24 Persons / South Side Sally 21 Pe
Condition: Invalid
Action required: 705 - Other - as specified
Due 29 March 2012
Resolved 29 March 2012
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 8 August 2011
Resolved
Install automatic engine and vent shutdowns IAW applicable regulations on a pre-engineered fixed fire fighting system.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 11 October 2011
Resolved 12 October 2011
Documentation › Certificates/Documents › Certificate of Number (state)
Issued 8 August 2011
Resolved
Provide state registration numbers.
Condition: Invalid
Action required: 705 - Other - as specified
Due 17 October 2011
Resolved 27 March 2012
Documentation › Markings/Placards › Warning Signs
Issued 8 August 2011
Resolved
[name withheld] fuel shutoffs with proper size and visibility.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 September 2011
Resolved 12 October 2011
Engineering › Gasoline Engine (propulsion) › Fuel Intake (2 stroke)
Issued 18 April 2007
Resolved
Replace flexible fuel lines with approved hoses or hard pipe fuel lines from fuel tank to engine.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2007
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 18 April 2007
Resolved
Replace fuel filter with metallic filter iaw 46CFR182.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2007
Engineering › Fuel Oil Storage/Transfer System › Hose
Issued 18 April 2007
Resolved
Re-route fuel line in engine compartment from proximity with exhaust manifold.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2007
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 April 2007
Resolved
Renew lens cover for port running light due to U/V damage.
Action required: 705 - Other - as specified
Resolved 9 May 2007
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 18 April 2007
Resolved
Replace one type B-I portable fire extinguisher with a marine type B-II portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 May 2007
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 18 April 2007
Resolved
Provide proof of random drug testing for CY 2006.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2010
Resolved 24 May 2010
Resolution: Vessel was sold to Just Ducky Tours Inc. and DAPI audit completed satisfactory.
Operations/Management › Drug and Alcohol Testing › MIS Submission
Issued 17 May 2005
Resolved
Provide proof of annual MIS submission.
Condition: Improper/Lack of Maintenance
Due 17 June 2005
Resolved 18 May 2005
Resolution: MIS submission received, via fax.
Stability › Watertight Integrity › General
Issued 17 May 2005
Resolved
Make permanent weld repairs to crack (approx. 1") in shaft tube.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 May 2005
Resolution: Shaft tube renewed "in-kind", float test, CG witnessed.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 17 May 2005
Resolved
Provide proof of drills (Monthy/Quarterly), IAW 46CFR185.520 and .524.
Condition: Improper/Lack of Maintenance
Due 17 June 2005
Resolved 18 May 2005
Resolution: Training/Drill log provided, via fax.
Operations/Management › Drug and Alcohol Testing
Issued 11 May 2004
Resolved
Provide proof of MIS submission for CY 2003. LEGACY COMPONENT DESC: MIS Submission
Condition: Unknown
Due 11 June 2004
Resolved 14 May 2004
Resolution: MIS Report submitted.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 11 May 2004
Resolved
Secure (bolt/fasten) bench seat aft/stbd, to the deck. LEGACY COMPONENT DESC: Open Deck Space
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 11 May 2004
Resolved 14 May 2004
Resolution: Seating bolted down to deck.
Fire Fighting › Fixed Halon Fire Extinguishing System
Issued 11 May 2004
Resolved
Renew, expended halon bottle/tank, provide proof/documentation for annual service of fixed halon system. LEGACY COMPONENT DESC: Tanks
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 14 May 2004
Resolution: Bottle renewed, proof of annual service provided.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 11 May 2004
Resolved
Repair gasoline/explosive gas detection alarm system. System test failed to give audible alarm as designed. LEGACY COMPONENT DESC: Ventilation
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 19 May 2004
Resolution: Renewed and tested explosive gas detector successfully.
Operations/Management › Drug and Alcohol Testing
Issued 9 April 2003
Resolved
Submit MIS report for CY 2002. LEGACY COMPONENT DESC: MIS Submission
Condition: Unknown
Due 9 May 2003
Resolved 29 May 2003
Resolution: Operator provided proof of MIS submission.
Electrical › Electrical Distribution System (service)
Issued 9 April 2003
Resolved
Install metal hangers in engine compartment, bundle conductors w/wire ties, place in hangers. LEGACY COMPONENT DESC: Conductor
Condition: Improper/Lack of Maintenance
Due 9 May 2003
Resolved 1 May 2003
Resolution: Hangers installed/utilized.
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 9 April 2003
Resolved
Remove spring clips and install/renew cotter pins in hinge plates of propusion shaft tube, IAW NVIC 1-01.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2003
Resolution: Cotter Pins installed, IAW NVIC 1-01
Engineering › Shafting/Propeller Arrangements › Intermediate Shaft
Issued 9 April 2003
Resolved
Hinge plate bolts, wrong length. Install shorter bolts with lock washers in hinge plate, for propulsion shaft tube, IAW NVIC 1-01.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 April 2003
Resolution: Bolts renewed, w/ proper length bolts.
Fire Fighting › Ventilation Systems
Issued 9 April 2003
Resolved
Install vent covers/louvers for engine compartment intake/exhaust vents to facilitate fixed extinguishing system actuation w/o the loss of extinguishing agent. LEGACY COMPONENT DESC: Ducts
Condition: Improper/Lack of Maintenance
Due 9 May 2003
Resolved 1 May 2003
Resolution: Covers installed.
Navigation › Collision/Grounding Avoidance
Issued 9 April 2003
Resolved
Demonstrate proper operation of nav lts. Prior to carriage of passengers in times of limited visibility and after sunset. LEGACY COMPONENT DESC: Navigation Lights
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 May 2003
Resolution: Nav lts operation, verified.
Documentation › Safety/Response Plans/Programs
Issued 5 April 2002
Resolved
Post vessel stability letter in the area of the operating station.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2002
Resolved 5 April 2002
Lifesaving › Lifejacket/PFD (General)
Issued 5 April 2002
Resolved
Post PFD instructions in the passenger area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 5 April 2002
Resolved 5 April 2002
Construction/Loadline › Structures
Issued 5 April 2002
Resolved
Replace gasket material for forward stowage area and engine compartment. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 3 May 2002
Construction/Loadline › Structures
Issued 5 April 2002
Resolved
Replace or renew the steel bevel that forms the knife edge for the door gasket for the engine compartment. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 3 May 2002
Construction/Loadline › Structures
Issued 5 April 2002
Resolved
Prove proper operation of all hatch closing devices for the forward stowage area and engine compartment. LEGACY COMPONENT DESC: Door
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 May 2002
Resolved 3 May 2002
Lifesaving
Issued 29 March 2001
Resolved
Relocate #3 and 4 P/S vertical canopy supports to allow unobstructed egressprior to carrying passengers in those seats.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Engineering
Issued 29 March 2001
Resolved
Provide & install keepers for fuel tank space vents on stern.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Engineering
Issued 29 March 2001
Resolved
Prior to operating with passengers, prove proper operation of all vapor detector alarms.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Construction/Loadline
Issued 29 March 2001
Resolved
Provide a permanent (weld bead or punched mark) indicating minimum freeboard at the vessel's stern.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Lifesaving
Issued 29 March 2001
Resolved
Provide for USCG review a company operations manual IAW NVIC 1-01.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Lifesaving
Issued 29 March 2001
Resolved
Prior to operating with passengers, demonstrate for USCG a satisfactory Fire, Abandon Ship, and Man overboard drill, and underway operational tests.
Condition: Unknown
Due 29 March 2001
Resolved 29 March 2001
Unknown
Issued 12 July 1999
Resolved
Provide CG Approved Crew Safety, Training and Maintenance Manual.
Condition: Unknown
Due 5 August 1999
Resolved 5 August 1999
Unknown
Issued 12 July 1999
Resolved
Prove compliance with employer sponsored drug testing program.
Condition: Unknown
Due 15 July 1999
Resolved 5 August 1999
Lifesaving
Issued 27 May 1999
Resolved
PROVIDE FIRST AID KIT APPROVED IAW 46 CFR.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Lifesaving
Issued 27 May 1999
Resolved
CONDUCT "NEW TO ZONE" INSPECTION AND EMERGENCY DRILLS TO SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999
Fire Fighting
Issued 27 May 1999
Resolved
INSTALL FLAMMABLE VAPOR DETECTION SYSTEM PRIOR TO OPERATING WITH PASSENGERS.
Condition: Unknown
Due 27 May 1999
Resolved 27 May 1999