MAURY USCG vessel records
← All vessels

MISS FREEDOM

MISS FREEDOM is a 1977 passenger vessel (inspected). The Coast Guard has recorded 20 inspections since 2016, most recently in April 2026, along with 7 deficiencies.

Records from 2016 to 2026. Most recent: inspection, 8 April 2026.

Built
1977
Last inspected
8 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Everything above is free. The detail below — the inspection history, the deficiency record and the documentation record — is Professional, $39 a month. Sign in.

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 April 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ6620
Flag
UNITED STATES
Maury page id
psix-49157

Documentation record

Registered dimensions (L × B × D)121.6 ft × 27.0 ft × 8.0 ft
Registered tonnagegross 98 / net 74
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORPORATION · WARREN, RI, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLIBERTY ISLAND, NY
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 30 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
74 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
Detail on this page

20 inspections, each with its date, unit and type; 7 deficiencies with the resolution recorded against each; the documentation record: dimensions, tonnage, builder, hailing port, endorsements, dates. The counts in the summary above are the same counts, and they are free.

$39 a month or $299 a year, every vessel page, cancel any time. Founding rate $19.99 a month for life, for the first 200 subscribers. Plans Sign in

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 20

8 April 2026 MSP Select Additional Oversight – Risk Assessment · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8344282
7 April 2025 Annual Inspection · Deficiency Check · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8106180
16 December 2024 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 8047800
9 April 2024 DAPI Audit · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7892166
13 September 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7791071
12 April 2023 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7667293
28 March 2022 COI Inspection · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7420017
17 November 2021 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7352971
4 October 2021 Internal Structural Exam · Drydock Exam
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7331933
13 April 2021 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7174074
14 September 2020 Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 7057999
23 September 2019 Hull Examination · Internal Structural Exam · Examination of Repairs
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6818867
10 April 2019 Annual Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6659055
6 September 2018 In-Service Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6535056
24 May 2018 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6422073
2 April 2018 Examination of Repairs · Administrative Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6383426
9 January 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6334547
14 September 2017 Internal Structural Exam · Hull Examination
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6277374
5 April 2017 COI Inspection · MTSA Verification
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 6118517
20 April 2016 Annual Inspection · Deficiency Check
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 5858310

Deficiency record · 7

07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 8 April 2026 Resolved
A device must be provided to automatically shut down power ventilation serving the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space. Pressure switch for the CO2 fixed firefighting system did not automatically shut down the generators in the engine room. Submit repair proposal for approval to local OCMI prior to installation of pressure switches for generators. 46 CFR 118.410(b)(10)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 9 April 2026
Resolution: Attached approved CO2 suppression approval.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 7 April 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Chart last updated 27Jul24. Update within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 April 2025
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 7 April 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Upgrade naviation chart to commercial within 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 23 April 2025
Fire Fighting › Fire Pumps › Capacity
Issued 24 May 2018 Resolved
The minimum capacity of the fire pump shall be 50 gallons per minute at a pressure of at least 60psi. During functional test of fire pump it was discovered that the pump was only rated for 55psi. Vessel must install a fire pump that meets the requirements.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2018
Resolved 6 June 2018
Resolution: Vessel rep installed a new fire pump, operated the pump and gauge indicate 65psi with one hose.
Deck/Cargo › Marine Portable Tanks › Bottom Filling/Discharge Connection
Issued 24 May 2018 Resolved
Vessels shall be inspected for compliance with the standards required by this sub-chapter. All other items shall be inspected to the standards acceptable the the local [name withheld] inspection it was noted the the pipe leading away from the drop pan in the sewage tank space had broken free. Vessel must repair.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2018
Resolved 6 June 2018
Resolution: vessel rep conducted permanent repair to the drip pan.
Electrical › Electric Supply System (service) › Battery Charger
Issued 20 April 2016 Resolved
01) Provide ammeter for battery charger on bridge.
Condition: Invalid
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 3 May 2016
Electrical › Lighting (emergency) › Lighting Fixture
Issued 20 April 2016 Resolved
02) Prove proper operation of emergency lighting on 2nd deck, aft-stbd side.
Action required: 705 - Other - as specified
Due 20 May 2016
Resolved 3 May 2016

Ownership record