MAURY USCG vessel records Sign in
← All vessels

KITZIANA

KITZIANA is a 1977 freight ship. The Coast Guard has recorded 24 inspections since 1982, most recently in October 2000, along with 37 deficiencies and 2 operational controls.

Records from 1982 to 2000. Most recent: inspection, 30 October 2000.

Built
1977
Last inspected
30 October 2000
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

7505956 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
HO2845
Flag
VANUATU
—
Maury page id
psix-49160

Inspections, by type

…with no type recorded11
Years with a record 10 calendar years (1982–2000)
The 24 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 26 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 1981.

Documentation record

Tonnage as PSIX records it199 - Convention (Subpart B), Net Ton
199 - Regulatory (Subpart C or D), Net Ton
665 - Convention (Subpart B), Gross Ton
685 - Regulatory (Subpart C or D), Gross Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspection history · 24

30 October 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 282893
22 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 282386
21 September 2000 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 279522
10 July 2000 Administrative
Administrative · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1051563
9 March 1992 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1008957
26 July 1990 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1240949
5 June 1990 Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 916417
5 April 1990 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1233453
1 November 1989 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 977077
5 October 1989 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1017185
21 September 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1322580
15 September 1989 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 898575
24 May 1989 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1039464
19 August 1988 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1038385
11 April 1988 Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1195806
10 July 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015439
6 June 1987 Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1019872
27 May 1987 Administrative
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1333768
27 January 1987 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1321993
2 October 1986 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318335
27 September 1985 Credit Drydock · Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 991917
4 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 974890
4 September 1984 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992249
29 July 1982 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275860

Deficiency record · 37

Accommodation/Occupational Safety
Issued 21 September 2000 Resolved
Galley is infested with bugs, vessel to have galley fumigated prior to departing Port of Miami.
Condition: Unknown
Due 21 September 2000
Resolved 21 September 2000
Lifesaving
Issued 21 September 2000 Resolved
Prior to departure and loading cargo, vsl must conduct an Annual Freight Exam (w/entire crew) w/USCG and satisfactorily perform firefighting and lifesaving drills.
Condition: Unknown
Due 21 September 2000
Resolved 21 September 2000
Documentation
Issued 21 September 2000 Resolved
Vessel has no crew list, vessel to provide crew list prior to departing Port of Miami.
Condition: Unknown
Due 21 September 2000
Resolved 21 September 2000
Documentation
Issued 21 September 2000 Resolved
Vessel has no Safe Manning Certificate, vessel to provide certificate priorto departing Port of Miami.
Condition: Unknown
Due 21 September 2000
Resolved 21 September 2000
Navigation
Issued 21 September 2000 Resolved
Vessel has no deviation card, vessel to provide deviation card by next US port.
Condition: Unknown
Due 31 October 2000
Resolved 31 October 2000
Construction/Loadline
Issued 5 April 1990 Resolved
RENEW GASKETS AND ADJUST AS NECESSARY AND PROVE EFFECTIVE SEAL ON ENGINEROOM FORE AND AFT WATERTIGHT DOORS IN ACCORDANCE WITH 46CFR171.111.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 5 April 1990 Resolved
PROVIDE HANDLE AND LABEL AT FOREPEAK BILGE SUCTION REACH ROD.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Navigation
Issued 5 April 1990 Resolved
PROVIDE A MAGNETIC COMPASS DEVIATION TABLE ON THE BRIDGE.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Construction/Loadline
Issued 5 April 1990 Resolved
RENEW OR REPAIR GASKETS AND KNIFE EDGES, ADJUST AS NECESSARY AND PROVE EFFECTIVE SEAL ON ALL WEATHER DECK WEATHERTIGHT DOORS, DUCT CLOSURES, AND ENGINE ROOM EXAUST CLOSURES IN ACCORDANCE WITH 46CFR42.15-10 & 35.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Electrical
Issued 5 April 1990 Resolved
RENEW THE WASTED ELCTRICAL CABLES AT THE FOREWARD MAST (MASTHEAD NAV LIGHT)IN ACCORDANCE WITH 46CFR91.25-10.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Accommodation/Occupational Safety
Issued 5 April 1990 Resolved
EFFECT REPAIRS AND PROVE OPERABLE THE MARINE SANITATION DEVICE IN ACCORDANCE WITH 33CFR159.7.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 5 April 1990 Resolved
PROVIDE HANDLES AND LABEL ALL REMOTE OPERATED REACH RODS FOR OIL TANKS IN ACCORDANCE WITH 46CFR56.50-75
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 5 April 1990 Resolved
PROVE OPERATION OF LOW LUBE OIL TRIPS BOTH MAIN PROPULSION ENGINES IN ACCORDANCE WITH 46CFR58.05-1.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 5 April 1990 Resolved
PROVIDE APPROVED AUTOMATION TEST PROCEEDURES IN ACCORDANCE WITH 46CFR61.40.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Engineering
Issued 5 April 1990 Resolved
PROVE OPERATION OF THE OVERSPEED TRIPS ON BOTH MAIN PROPULSION ENGINES IN ACCORDANCE WITH 46CFR58.05-1.
Condition: Unknown
Due 5 April 1990
Resolved 5 April 1990
Unknown
Issued 2 October 1986 Resolved
SERVICE ALL DOWELL-SCHLUMBERGER PORTABLE FIRE EXTINGUISHER. PROVIDE SEAL- PORTABLE FIRE EXTINGUISHERS IN ENGINE ROOM THAT IS WITHIN-CURRENT (5 YEAR) HYDRO TEST DATE.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
PROVIDE TWO COMPLETE FIREMAN'S OUTFITS IN ACCORDANCE WITH 46 CFR 96.35-10. REPAIR LOW BELL ON MSA REGULAR AND REPAIR GOUGE ON MSA.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
RENEW OR REPAIR AS NECESSARY HOLED AIR START LINE IN WAY OF SOFT PATCHED AREA ON STARBOARD MAIN ENGINE.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
PROVIDE EQUIPMENT FOR RESCUE BOAT: BOW AND STERN PAINTERS, PROPER OAR AND OARLOCKS, AND PELICAN STYLE RELEASE HOOK.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
ESTABLISH MAXIMUM ALLOWABLE WORKING PRESSURE OF ALL FOUR (4) DRY BULK MUD TANKS. PROVIDE AND TEST IN LINE RELIEF VALVE SET AT A PRESSURE NOT TO EXCEED THE MAWP. EQUIP RELIEF VALVE WITH HAND RELIEVING GEAR.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
EQUIP FOLLOWING PRESSURE OF THE TANKS OR 100 PSIG/1200% WHICHEVER IS LOWEST; HOT WATER HEATER, SANITARY WATER PRESSURE SET AND PORTABLE WATER PRESSURESET.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
PROVIDE TWO ADDITIONAL COAST GUARD APPROVED TYPE I, LIFEJACKETS EQUIPPED WITH WHISTLE AND LIGHT.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
INSTALL FIXED FIRE FIGHTING SYSTEM IN PAINT LOCKER.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
INSTALL REQUIRED PLASTIC BOWL PROTECTORS ON ALL RECOR FUEL FILTERS ON BOTH MAIN ENGINES.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
RENEW ALL HATCHES ON DRY BULK MUD TANKS USING A WELDING PROCEDURE ACCEPTA- BLE TO THE MANUFACTURES AND ACCORDANCE TO ASME STANDARDS. USE WELDER QUALIFIED TO THE PRCEDURED. UNTIL PERMANENT REPAIRS ARE MADE, TANKS SHALL NOT BE USED.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
PROPERLY LABEL RANGE DISCONNECT SWITCH.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
EQUIP ALL FIRE HOSE STATUS WITH U.L. APPROVED HOSE AND APPROVED COMBINATIONNOZZLES. REMOVE ALL ADAPTERS, UNAPPROVED HOSE, AND UNAPROVED NOZZLES FROM VESSEL.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
PROVIDE COAST GUARD APPROVED INFORMATION OR, AND RESTORE TO PROPER WORKING ORDER; INSTALLED MARINE SANITATION DEVICE.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
RENEW PIPING DIAGRAM FOR OIL TRANSFER PROCEDURES.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
TEST OIL TRANSFER HOSE TO A MINIMUM PRESSURE OF 225 PSIG, AND MAINTAIN RECORDS ON HOSE AND TRANSFER EQUIPMENT IN ACCORDANCE WITH 33 CFR 155.820.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
PROVIDE AND POST LEGIBLE FIREFIGHTING AND LIFESAVING PLAN.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
OBTAIN NEW STABILITY LETTER BASED ON CARRIAGE OF ACIDIZING EQUIPMENT AND CARGO VERTICAL CENTER OF GRAVITY WHICH EXCEEDS THREE (3) FEET.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
MAN VESSEL IN ACCORDANCE WITH CURRENT COI, NAMELY PROVIDE ONE (1) ABLE BODIED SEAMAN IN CREW.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
PROVIDE EMERGENCY ILLUMINATION FOR PORT SIDE LIFERAFT AREA.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
MAKE OPERABLE BILGE LEVEL ALARM.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
RE-INSTALL PARALLEL LOCK OUT BAR ON MAIN SWITCHBOARD. RENEW LIGHT BULB ON MAIN GROUND DETECTOR CIRCUIT.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986
Unknown
Issued 2 October 1986 Resolved
RENEW MOTOR CONTROLLERS ON FREEZER AND CHILL BOX COMPRESSOR REPLACING/ REPAIRING AT A MINIMUM THE FUSE BOTTOM STOP/START SWITCHES AND THE SAFETY OVERRIDES.
Condition: Unknown
Due 2 October 1986
Resolved 2 October 1986

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.