Inspection history · 19
22 April 2026
Internal Structural Exam · Deficiency Check · Vessel Attendance · Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8331783
15 April 2026
Internal Structural Exam · Examination of Repairs · Vessel Attendance · Administrative Inspection · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8331739
3 March 2025
Administrative Inspection · Deficiency Check · Internal Structural Exam · Annual Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8087233
12 March 2024
COI Inspection · Examination of Repairs · Drydock Exam · In-Service Inspection · Internal Structural Exam · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7878035
12 April 2023
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7667187
19 May 2022
Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7454483
7 April 2022
Administrative Inspection · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7426700
4 May 2021
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7181267
26 May 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6961027
18 May 2020
Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6955099
30 April 2019
Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6673794
29 April 2019
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6673000
16 March 2019
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6645504
24 May 2018
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6417128
3 April 2018
In-Service Inspection · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6384546
23 October 2017
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6326561
24 April 2017
Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6131204
17 May 2016
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5882296
28 March 2016
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5842289
09 - Working and Living Conditions › 092 - Working Conditions › Fitness for duty - intoxication
Issued 22 April 2026
Resolved
No marine employer may engage or employ any individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer. Marine Inspector observed that Deckhand on board at time of the inspection was not included on the list of crew members for the consortium.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 11 May 2026
Resolution: Vessel provided documentation showing new deckhand has been added to the consortium.
09 - Working and Living Conditions › 092 - Working Conditions › Pipes, wires (insulation)
Issued 22 April 2026
Resolved
Internal combustion engine exhaust, boiler, and galley uptakes, and similar sources of ignition shall be kept clear of and suitably insulated from any woodwork or other combustible matter. Marine Inspector found insulation removed from exhaust pipe and needs to be reinstalled.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 May 2026
Resolved 11 May 2026
Resolution: Vessel reinstalled inulation. Deficiency rectified.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 April 2025
Resolved
Penetrations and openings in watertight bulkheads must; have means to make them watertight... Observed wire penetration between engine room and rudder room on upper port side of bulkhead to not be watertight. Seal bulkhead penetration to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 15 May 2025
Resolution: Received photos of sealed bulkhead penetration.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 9 April 2025
Resolved
Before getting underway on a voyage or as soon as practicable thereafter, the master of a vessel shall ensure that suitable public announcements are made informing all passengers of the following: (1) The location of emergency exits, survival craft embarkation areas, and ring life buoys;(2) The stowage location(s) of life jackets;(3) Either:(i) The proper method of donning and adjusting life jackets of the type(s) carried on the vessel including a demonstration of the proper donning of a lifejacket, or(ii) That passengers may contact a crew member for a demonstration as appropriate, prior to beginning an oceans or coastwise
voyage(4) The location of the instruction placards for
life jackets and other lifesaving devices; (5)That all
passengers will be required to don life jackets when
possible hazardous conditions exist, as directed by the master; and (6)If the vessel is operating with reduced manning or equipment requirements in § 176.114 of this chapter... Vessel did not have a standard brief for crew passengers prior to getting underway. Perform passenger brief to include items 1 through 6 above to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 15 May 2025
Resolution: Spoke with owner and verified operator is giving verbal briefings prior to getting underway.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 9 April 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date:(1) Charts of large enough scale to make safe navigation possible... Vessel's electronic chart not up to date. Ensure charts are updated to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 15 May 2025
Resolution: Received photos of electronic chart update.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 April 2025
Resolved
Unless other means are provided to ensure that a potential waste receptacle fire would be limited to the receptacle, waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom.
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 May 2025
Resolved 15 May 2025
Resolution: Received photos of trash receptacle removed from vessel.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 24 April 2024
Resolved
All vessels shall be provided with a hand operated portable fire pump having a capacity of at least 5 gallons per minute. This fire pump shall be equipped with suction and discharge hose suitable for use in fire fighting. (b) The hand portable fire pump may also serve as a bilge pump. Vessels portable hand pump was inoperable. Additional hose used to reach the water was not secure.
46 CFR 181.10-5
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2024
Resolved 26 April 2024
Resolution: New hose was secured to handpump. Observed full operation of the pump and its ability to reach the water.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 April 2024
Resolved
Each water light must be of an approved automatic electric type, constructed in accordance with subpart 161.010 of this chapter, except as allowed under paragraph (c) of this section. Water light was inoperable and was fitted with a battery that has been expired for 8 years. Vessel is daylight restricted.
46 CFR 180.30-1(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2024
Resolved 26 April 2024
Resolution: Battery was replaced and water light was operational.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 April 2024
Resolved
Each life preserver carried on a vessel must have at least 200 sq. cm (31 sq. in.) of retroreflective material attached on its front side, at least 200 sq. cm on its back side, and at least 200 sq. cm of material on each of its reversible sides. Retroreflective material on 2 PFDs were wasted and not longer reflective. Vessel is authorized to carry 41 passengers.
46CFR 180.25-25
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2024
Resolved 26 April 2024
Resolution: Worn Retro was replaced and PFDs were put back in service.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 April 2024
Resolved
Before getting underway, the master of each vessel subject to this subpart shall ensure that suitable public announcements, instructive placards or both are provided in a manner which affords all passengers the opportunity to become acquainted with… Proper method of donning and adjusting life preservers of the type(s) carried on the vessel; Vessel provided instructions for 2 out of 5 types of PFDs carried on board. Master will demonstrate donning instructions until all 5 PFD donning placards are posted.
46CFR 185.25-1(d)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2024
Resolved 26 April 2024
Resolution: 4 out of 5 PFD donning placard was posted. Vessel captain will brief crew and passangers on how to properly don the PFD (that does not have a placard) prior to getting underway.
04 - Emergency Systems › N/A - No Subsystem › Public address system
Issued 24 April 2024
Resolved
Except as otherwise provided in this section, it shall be the duty of the master of any vessel subject to the regulations in this Subchapter to prepare and post emergency checkoff lists in a conspicuous place accessible to crew and passengers. Vessel had no emergency instructions provided for the crew or passengers. Master will brief emergency instructions to crew and passengers prior to getting underway until emergency instructions are posted.
46 CFR 185.25-1(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2024
Resolved 26 April 2024
Resolution: A printed set of emergancy instructions is posted in the wheelhouse.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 24 April 2024
Resolved
The employer shall provide an Employee Assistance Program (EAP) for all crewmembers.... must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Crew was unfamiliar with EAP and there was no display or distribution on information.
46 CFR 16.401
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 May 2024
Resolved 26 April 2024
Resolution: Vessel owner porvided proof of enrollment in EAP. Contact information was posted in the wheelhouse.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 19 May 2022
Resolved
Vessel must have onboard a 25 foot fire hose which can be a garden hose. Vessel only had a 12 foot garden hose onboard which could not reach around to the engine room.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 19 May 2022
Resolution: Pics received
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 May 2022
Resolved
Vessel's life ringbuoy was missing retroreflective tape
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 June 2022
Resolved 19 May 2022
Resolution: pics recieved attesting to repairs.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 4 May 2021
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment other than small buoyancy compartments under all practical conditions. IAW Table 182.25-10(a) S vessels with less than 49 passengers 26' to 65', 1 fixed 10 GPM and 1 portable 5 GPM or 1 fixed hand pump 10 GPM and 1 portable hand pump at 5 GPM. Vessel's fixed bilge system is not drawing suction from all spaces.
46 CFR 182.25-1
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 May 2021
Resolution: Crew repaired bilge dewatering system and conducted satisfactory operational test.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 4 May 2021
Resolved
Except as further modified in this section where fire extinguishing systems or equipment are not required, but are installed, the system or equipment must meet this part. Vessel is equipped with a fixed fire pump and portable fire pump instead of fire buckets required by New Subchapter "T", the fire pump cannot produce adequate pressure to extinguish a fire. Hand pump not on board.
46 CFR 181.05-5
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 5 May 2021
Resolution: Crew repaired fixed fire pump and conducted satisfactory operational test.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 4 May 2021
Resolved
Lifejacket placard containing instructions for donning and use of the lifejacket aboard the vessel must be posted in conspicuous places that are regularly assessible and visible to the crew and passengers. Vessel has two types of lifejackets, but only a placard for one type.
46 CFR 185.516
Action required: 10 - Deficiency Rectified
Resolved 4 May 2021
Resolution: Crew provided and placed lifejacket placard onboard vessel to meet both types of lifejacket donning procedures.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 4 May 2021
Resolved
Lifejackets - All vessels shall be provided with an approved adult type life preserver for each person carried. The vessel is required 45 adult life lifejackets and only has 36. Vessel is restricted to 34 passengers until 9 additional lifejackets are approved and provided. Owner replaced 8 of 9, passenger count reduced to 42 until last PFD is replaced.
46 CFR 180.25-5
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2021
Resolution: Crew provided one life preserver to meet passenger count as per COI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 May 2021
Resolved
Each ring buoy must be marked with type II retroreflective material approved in accordance with 46 CFR 164.018. The ring buoy was not marked with retro-refelctive material.
46 CFR 185.604(i)
Action required: 10 - Deficiency Rectified
Resolved 4 May 2021
Resolution: Crew provided and installed retro-reflective material for the ring buoy.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 4 May 2021
Resolved
A marine employer whose vessel is involved in a marine casulty or incident, that is, or is likely to become a serious marine incident shall comply with the requirements of 46 CFR 4.06. 46 CFR 4.06 states a marine employer must have a sufficient number of alcohol testing devices readily accessible onboard the vessel. The vessel did not have alcohol testing devices nor did they have an established plan to get alcohol testing completed within 2 hours.
46 CFR 189.212
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2021
Resolution: Captain stated that the vessel will utilize police station for testing.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2021
Resolved
All vessels shall be equipped with a hand operated portable pump having a capacity of at least 5 gallons per minute. The vessel was missing the required hand fire pump.
46 CFR 181.10-5
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2021
Resolution: Crew provided hand operated portable pump and conducted operational test.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 May 2021
Resolved
All hand portable fire extinguishers and semi-portable fire extinguishing systems shall be checked as noted in Table 176.25-25(a)(2), and in addition shall be examined for excessive corrosion and general condition. One of two portable fire extinguishers for the machinery space is missing a tamper seal.
46 CFR 176.25-25(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 12 May 2021
Resolution: New tamper seals installed on both portable fire extinguishers for the machinery space.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 4 May 2021
Resolved
All electrical installations shall be to the satisfaction of the Officer In Charge, Marine Inspection. Exposed wire terminal lugs were observed to be disconnected and unlabeled in the space underneath operating station console and the forward bulkhead of the engine room. Cables that are unused shall be removed from service.
46 CFR 183.01-15(a)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 12 May 2021
Resolution: Crew removed unused cable located on the forward bulkhead of the engine room and capped/sealed disconnected cable terminals underneath operator station console.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 May 2020
Resolved
A vessel must comply with the structural design requirements of ABS aluminum Vessel Rules. Inspection of hull revealed 03 holes of varying sizes 1" to 2" in diameter penetrating the hull on the STBD side approximately 4-6" up from the keel. Repairs must be completed prior to the completion of dry dock. 46 CFR 177.300 (d)(ii)
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 22 May 2020
Resolution: Owner repaired with 02 inserts, welds tested via pressure washer to the satisfaction of the attending MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 March 2019
Resolved
46 CFR 176.01-1(a) Except as noted in this subpart, every vessel subject to inspection and certification shall, when carrying more than six passengers, have on board a valid certificate of inspection and shall be operated in compliance therewith.
Vessel was being operated without a deckhand when the COI requires there to be one onboard.
Action required: 10 - Deficiency Rectified
Due 30 March 2019
Resolved 16 March 2019
Resolution: Vessel owner called in a third employee that meets all requirements to be a deck hand on the vessel after the second employee was discovered to not meet DAPI requirements.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 16 March 2019
Resolved
46 CFR 16.210: No marine employer shall engage or employ and individual to serve as a crewmember unless the individual passes a chemical test for dangerous drugs for that employer.
Discovered that the crew member used after DEF #1 was issued the company used an employee who had not been drug tested to act as a deckhand.
Action required: 10 - Deficiency Rectified
Due 30 March 2019
Resolved 16 March 2019
Resolution: Vessel Owner called in a Licensed / Credintialed Captain to act as deckhand for the remainder of the work day. Verified the employee met all requirments.
Engineering › Bilge Water Management System › Not Operational
Issued 24 May 2018
Resolved
Vessels will be provided with bilge pumps in accordance with table 182.25-10(a). Vessels bilge pump is inoperative.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 June 2018
Resolved 25 May 2018
Resolution: Vessel installed a new impeller, all tests SAT
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 17 May 2016
Resolved
Vessel has no publications on board.
Condition: Invalid
Action required: 705 - Other - as specified
Due 24 May 2016
Resolved 2 May 2017
Resolution: This def was never cleared from previous inspection. Vessel has all required publications and passed inspection May 2017