MAURY USCG vessel records Sign in
← All vessels

TINA LOUISE

TINA LOUISE is a 1999 passenger vessel (inspected). The Coast Guard has recorded 43 inspections since 1999, most recently in October 2025, along with 72 deficiencies.

Records from 1999 to 2025. Most recent: inspection, 2 October 2025.

Built
1999
Last inspected
2 October 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ3475
491687
Flag
UNITED STATES
367500610
Maury page id
psix-491687

Inspections, by type

…with no type recorded1
Years with a record 23 calendar years (1999–2025)
The 43 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)43.7 ft × 12.1 ft × 2.4 ft
Registered tonnagegross 8 / net 6
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWAYNE BAILEY · DELMAR, DE, UNITED STATES · built 1999
Hull materialWood
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portWENONA, MD
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 25 June 2026 · expires 31 July 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it8 - Simplified, Gross Ton
6 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDF8984MMSI 367500610 · active · compulsorily equipped · granted 9 July 2021, expires 30 July 2031
WCZ3475MMSI not assigned · expired · voluntarily equipped · granted 21 June 1999, cancelled 22 August 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 43

2 October 2025 COI Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8245586
30 September 2025 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8244214
26 August 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8218268
7 August 2025 Drydock Exam · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8205086
16 July 2025 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8187301
3 October 2024 Annual Inspection · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8014226
10 October 2023 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7807927
22 September 2023 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7796498
5 June 2023 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7710484
4 February 2022 Administrative Inspection · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7390856
15 April 2021 Annual Inspection · Internal Structural Exam · Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7188931
1 April 2021 Drydock Exam · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7166332
20 August 2020 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7038982
21 September 2019 Type not recorded
No type recorded · Station Crisfield · USCG East District (CGD-E) · Activity 6818006
20 June 2019 Annual Inspection · DAPI Audit
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6720667
15 April 2019 Internal Structural Exam · Drydock Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6663795
19 July 2018 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6485405
2 April 2018 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6388159
7 February 2017 In-Service Inspection · DAPI Audit · Drydock Exam · Administrative Inspection · COI Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 6084211
22 June 2016 Deficiency Check · DAPI Audit · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5920442
14 August 2015 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 5215733
6 September 2011 Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 4143987
30 March 2009 Drydock Exam · Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3442933
3 April 2008 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3195786
31 March 2008 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 3174537
18 April 2007 Deficiency Check · COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2916752
6 April 2006 Annual Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2638587
22 March 2006 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2613439
13 June 2005 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2450964
1 September 2004 Periodic Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2183295
30 March 2004 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 2033848
22 July 2003 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1854708
28 May 2003 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1821574
25 April 2002 COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1609104
4 March 2002 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1490531
30 May 2001 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1362237
21 April 2000 Re-Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1389102
22 July 1999 Deficiency Check
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1104154
22 July 1999 Administrative
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1104159
8 May 1999 Hull Examination
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1129242
8 May 1999 Initial Certification
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1130564
17 March 1999 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 810194
5 February 1999 Plan Review "T" Boat
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 1384023

Deficiency record · 72

01 - Certificates & Documentation › 012 - Crew Certificates › Medical certificate
Issued 7 August 2025 Resolved
Medical certificates issued to all other mariners will be issued for a maximum period of 5 years. Master could not provide medical certificate. 46CFR10.301(b)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 August 2025
Resolution: Recieved objective evidence to rectify def. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 7 August 2025 Resolved
A portable hand bilge pump must be:(1) Capable of pumping water, but not necessarily simultaneously, from all watertight compartments; and(2) Provided with suitable suction hose capable of reaching the bilge of each watertight compartment and discharging overboard Portable hand bilge pump could not provide suction and discharge overboard from any space. 46CFR182.520(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 18 August 2025
Resolution: Recieved objective evidence to rectify def. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 7 August 2025 Resolved
A vessel must carry one floating water light, unless it is limited to daytime operation, in which case no floating water light is required. Life ring water light battery was expired (2018) 46CFR180.70(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2025
Resolution: Receievd objective evididence that the light was working.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 August 2025 Resolved
The discharge ends of fuel tank vent pipes must terminate on the hull exterior as high above the waterline as practicable and remote from any hull openings, or they must terminate in U-bends as high above the weather deck as practicable and as far as practicable from openings into any enclosed spaces. Both diesel fuel tanks did not vent outside the space and did not have flame screens. 46CFR182.450(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 2 October 2025
Resolution: Fuel tank vent/piping was installed. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 7 August 2025 Resolved
Remote fuel shutoff stations must be marked in clearly legible letters at least 25 millimeters (1 inch) high indicating purpose of the valve and direction of operation. Fuel shutoff valves were not labeled. 46CFR185.608
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 September 2025
Resolution: Receievd objective evidence that the fuel cutoff valve was labeled.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 7 August 2025 Resolved
Each ship transporting more than six passengers for hire equipped with a radiotelephone station IAW part III of the Communications Act must carry a radio operator who meets the following requirements. Master could not provide radio operators 47CFR80.159(e)
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 18 August 2025
Resolution: Recieved objective evidence to rectify def. All sat.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 July 2025 Resolved
Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. As of 14JUL2025 the vessel as exceeded time-frame for an annual inspection. 46CFR176.500
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2025
Resolution: Conducted Annual insoection.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 16 July 2025 Resolved
The owner or managing operator shall make a vessel available for drydock examinations, internal structural examinations, and underwater surveys (UWILD) required by this section. A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. As of 30JUN2025 the vessel as exceeded the time-frame for a drydock and internal structural examination. 46CFR176.600
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2025
Resolution: Conducted drydock/ISE exam
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 3 October 2024 Resolved
11116 - Lakes, bays, and sounds, and rivers routes. A vessel on a lakes, bays, and sounds, or rivers route must carry:three hand red flare distress signals and three hand orange smoke distress signals. Red flare distress signals may substitute orange smoke distress signals. The flares on board the vessel were expired. 46 CFR 180.68(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2025
Resolution: New flares were on board. All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 October 2024 Resolved
01305 - Abandon ship and man overboard drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include date of the drill and training and General description of the drill scenario and training topics. The vessel has not logged man overboard drills since April 2024 and had no abandon ship drills logged. Drills must be completed every 3 months. 46 CFR 185.520(f)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2025
Resolution: Drills were loggeg in log book. All sat.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 3 October 2024 Resolved
01305 - Fire fighting drills and training shall be logged or otherwise documented for review by the Coast Guard upon request. The drill entry shall include the following information:(1) Date of the drill and training; and(2) General description of the drill scenario and training topics. The vessel had no fire drills logged since May 2024. Drills must be completed every 3 months. 46 CFR 185.524(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2025
Resolution: Fire drill logged in logbook. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 October 2024 Resolved
11117 - A vessel must have one or more ring life buoys as follows a vessel of more than 26 feet in length, but not more than 65 feet, must carry a minimum of one life buoy of not less than 24 inches in diameter. The vessels life buoy was deteriorated rendering it inoperable. 46 CFR 180.70(a)(2)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2025
Resolution: New life buoy on board. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 3 October 2024 Resolved
13199 - On a vessel of at least 7.9 meters (26 feet) in length, a visual and audible alarm must be provided at the operating station to indicate a high water. The high water alarm visual indicator was inoperable. 46 CFR 182.530(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2025
Resolution: Bilge alarms tested sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 October 2024 Resolved
07110 - The installation and location of portable fire extinguishers must be to the satisfaction of the Officer in Charge, Marine Inspection. One of the 4A-80-B:C extinguishers was not mounted. 46 CFR 181.520
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2025
Resolution: Fire extinguisher was mounted.
10 - Safety of Navigation › N/A - No Subsystem › Magnetic compass
Issued 3 October 2024 Resolved
10105 - Except as otherwise provided in this section every vessel must be fitted with a suitable magnetic compass to be mounted at the primary operating station. The magnetic compass was not mounted. 46 CFR 184.402(a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 August 2025
Resolution: Compass was mounted. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 3 October 2024 Resolved
13103 - Gauges to indicate engine revolutions per minute (RPM)must be provided for all propulsion engines installed in the vessel. The gauges must be readily visible at the operating station. The operator was unable to show the Marine Inspector the RPM gauge. 46 CFR 1882.410(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2025
Resolution: RPM gauge was all sat.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 3 October 2024 Resolved
01310 - A ship, except a ship of less than 26 feet in length, must have a Discharge of Oil Prohibited placard of at least 5 by 8 inches, made of durable material fixed in a conspicuous place in each machinery space, or at the bilge and ballast pump control station. The vessel did not have an oil discharge placard. 33 CFR 155.450(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2025
Resolution: Oil discharge placard was on board.
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 3 October 2024 Resolved
01310 - The person in charge of a ship shall ensure that one or more placards meeting the requirements of this section are displayed in prominent locations and in sufficient numbers so that they can be read by the crew and passengers. The vessel did not have a discharge of garbage prohibited placard. 33 CFR 151.59
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 August 2025
Resolution: Garbage placard was on board.
01 - Certificates & Documentation › 011 - Ships Certificates › Cargo Ship Safety Radio (including exemption)
Issued 3 October 2024 Resolved
01104 - Every vessel subject to Part III of Title III of the Communications Act must have a detailed inspection of the radio installation by an FCC-licensed technician in accordance with § 80.59 once every five years. If the ship passes the inspection, the technician will issue a Communications Act Safety Radiotelephony Certificate. The vessel did not have a Safety Radio Certificate on board. 47 CFR 80.903
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2025
Resolution: Safety radiotelephony certificate was on board and valid.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 10 October 2023 Resolved
46 CFR 180.137(a)(2) The float-free link required by 180.130(a)(1) must be of proper strength for the size of the life float as indicated on its identification tag. Vessel carries a 10 person life float and link is rated for 11-20 person life float. Replace with appropriate weak link and replace corroded painter.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 7 August 2025
Resolution: Life float was removed and taken off the COI at the Masters request. COI will be amended to only operate in warm water only.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 October 2023 Resolved
46 CFR 176.810(b)(1) Portable extinguishers must be inspected and maintained IAW NFPA 10 as amended. 2A extinguisher was missed during annual servicing.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 October 2024
Resolution: All fire extinguishers were serviced 09/2024.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 October 2023 Resolved
46 CFR 185.604 The number and identification of the items stowed inside, and their sized, must be marked in clearly legible letters and numbers on each container. Label child and adult life jacket containers in 2" high letters and numbers.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 3 October 2024
Resolution: Witnessed proper PFD stowage location labeling.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 22 September 2023 Resolved
CG001 - Your vessel must undergo an annual inspection within the 3 months before or after each anniversary date. You must contact the cognizant OCMI to schedule an inspection at a time and place which he or she approves. No written application is required. Your vessel was due to have completed an annual inspection by 14 July 2023. You may not carry passengers until an annual inspection is completed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 10 October 2023
Resolution: Conducted annual inspection
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 20 August 2020 Resolved
Vessel had insufficient amount of flares for Lakes, Bays, and Sounds route.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 August 2020 Resolved
Life float paddles were not attached to the life float
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 15 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 August 2020 Resolved
The life float waterlight line was connected to the vessel and also used as the painter for the life float. There needs to be two seperate lines, one for the waterlight and one for the painter.
Action required: 705 - Other - as specified
Due 31 October 2020
Resolved 15 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 August 2020 Resolved
Water light line on life buoy is fraying. Life line was not 60 ft.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2021
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 20 August 2020 Resolved
Fuel shutoff valve was not labeled
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 September 2020
Resolved 15 April 2021
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 20 August 2020 Resolved
Vessel did not have a third serviced fire extinguisher on board.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 15 April 2021
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 July 2018 Resolved
Provide on board 3 hand held Red Flares.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 July 2018
Resolved 23 July 2018
Resolution: Received via email proof of correction.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 19 July 2018 Resolved
Provide proof of current Certificate of Documentation and place on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2018
Resolved 13 September 2018
Resolution: Received via email proof of correction.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 19 July 2018 Resolved
Provide copy of Coast Pilot/Light List and Tide Tables on board.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2018
Resolved 24 July 2018
Resolution: Received via email proof of correction.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 19 July 2018 Resolved
Repair/Replace Life Float including new retro-reflactive tape.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2018
Resolved 17 August 2018
Resolution: Received via email proof of correction.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 19 July 2018 Resolved
provide on board First Aid Kit in compliance with 46 CFR 160.041.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2018
Resolved 24 July 2018
Resolution: Received via email proof of correction.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 19 July 2018 Resolved
Provide on board 2 2.5 gal fire buckets, Total 3.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2018
Resolved 24 July 2018
Resolution: Received via email proof of correction.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Number
Issued 20 April 2017 Resolved
Provide A-II portable fire extinguisher on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 31 May 2017
Resolution: Attended vessel and cleared above deficiency.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 20 April 2017 Resolved
Provide 02 Alcohol test kits on board.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 31 May 2017
Resolution: Attended vessel and cleared above deficiency.
Construction/Loadline › Structures › Door
Issued 7 February 2017 Resolved
Cabin access door only 23.5 inches. Cabin is restricted to crew members only.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 20 May 2018
Resolved 13 September 2018
Resolution: Door access approved by OCMI.
Navigation › Piloting/Steering › US Coast Pilot
Issued 7 February 2017 Resolved
Provide Coast Pilot and Light List for OP Area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 31 May 2017
Resolution: Attended vessel and cleared above deficiency.
Navigation › Collision/Grounding Avoidance › Radar
Issued 7 February 2017 Resolved
Install and prove proper operation of marine radar.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 31 May 2017
Resolution: Attended vessel and cleared above deficiency.
Navigation › Piloting/Steering › Magnetic Compass
Issued 7 February 2017 Resolved
Install magnetic compass with light.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 31 May 2017
Resolution: Attended vessel and cleared above deficiency.
Electrical › Lighting (service) › Lighting Fixture
Issued 7 February 2017 Resolved
Properly install all wiring to include ground wires and light / speaker wires. Remove old wires and properly secure dead-end wires.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 31 May 2017
Resolution: Attended vessel and cleared above deficiency.
Engineering › Bilge Water Management System › Not Operational
Issued 22 June 2016 Resolved
Bilge and High water alarm not working, (Electrical Problem). Repair/replace and prove proper operation to attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2016
Resolved 30 June 2016
Resolution: Attended vessel and cleared above deficiency.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 22 June 2016 Resolved
Mast Head light not operating properly. Repair/Replace to satisfaction of attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 June 2016
Resolved 30 June 2016
Resolution: Attended vessel and cleared above deficiency.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 18 April 2007 Resolved
Line from ring buoy to light not CG approved. Need 3-6 ft dark synthetic line IAW 46 CFR 180.70(c).
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2007
Resolved 20 April 2007
Resolution: Attended vessel to conduct deficiency follow-up. Cleared above deficiency.
Lifesaving › Lifefloat › Lifeline
Issued 18 April 2007 Resolved
Line from life float to the light not CG approved need 18ft lanyard IAW 46 CFR 180.175(f)(1).
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2007
Resolved 20 April 2007
Resolution: Attended vessel to conduct deficiency follow-up. Cleared above deficiency.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 April 2007 Resolved
Need CG approved first aid kit w/eye wash solution.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2007
Resolved 20 April 2007
Resolution: Attended vessel to conduct deficiency follow-up. Cleared above deficiency.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 April 2007 Resolved
Need masthead light IAW Navrules # 23.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2007
Resolved 20 April 2007
Resolution: Attended vessel to conduct deficiency follow-up. Cleared above deficiency.
Lifesaving › Lifefloat › Retroreflective Material
Issued 18 April 2007 Resolved
Add retroreflective material to life float.
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 April 2007
Resolved 20 April 2007
Resolution: Attended vessel to conduct deficiency follow-up. Cleared above deficiency.
Fire Fighting › Fixed Fire Detection System › Approval
Issued 18 April 2007 Resolved
install a type-approved fire detection system in the engine compartment by July31, 2007.
Action required: 705 - Other - as specified
Due 1 April 2008
Resolved 3 April 2008
Resolution: Vessel currently has a type approved structural fire protection system installed.
Communications › Radio Communications › VHF Radiotelephone
Issued 6 April 2006 Resolved
Provide proof of valid FCC safety certificate.
Due 6 May 2006
Resolved 15 May 2006
Resolution: Recived fax of FCC safety cert.
Communications › Alarms/Indicators
Issued 28 May 2003 Resolved
PROVIDE SEPARATE VISUAL/AUDIBLE INDICATOR FOR SECOND BILGE HIGH WATER ALARM. LEGACY COMPONENT DESC: High Water Alarm
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 22 July 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 28 May 2003 Resolved
RE-MOUNT BRACKET FOR BII PORTABLE FIRE EXTINGUISHER IN CABIN. LEGACY COMPONENT DESC: Mounting Bracket
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 22 July 2003
Lifesaving › Buoyant Apparatus
Issued 28 May 2003 Resolved
LABEL LIFE FLOAT WITH NUMBER OF PASSENGERS CAPACITY.
Action required: 705 - Other - as specified
Due 28 June 2003
Resolved 22 July 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher
Issued 25 April 2002 Resolved
SERVICE BII EXTINGUISHER. ITEM TO BE COMPLETED PRIOR TO CARRYING PASSENGERS. LEGACY COMPONENT DESC: Service
Due 27 April 2002
Resolved 25 April 2002
Lifesaving › Hand Flares
Issued 25 April 2002 Resolved
OBTAIN THREE FLARES. ITEM TO BE COMPLETED PRIOR TO CARRYING PASSENGERS. LEGACY COMPONENT DESC: Condition
Due 27 April 2002
Resolved 25 April 2002
Lifesaving › Buoyant Apparatus
Issued 25 April 2002 Resolved
RENEW LIGHT FOR LIFEFLOAT. VSL IS RESTRICTED TO DAYLIGHT OPERATIONS UNTIL COMPLETED.
Due 27 April 2002
Resolved 25 April 2002
Navigation › Piloting/Steering
Issued 25 April 2002 Resolved
PROVIDE A COPY OF TIDE TABLES. LEGACY COMPONENT DESC: Tide/Tidal Current Tables
Due 25 May 2002
Resolved 25 April 2002
Navigation › Collision/Grounding Avoidance
Issued 25 April 2002 Resolved
RENEW/REPAIR STBD RUNNING LIGHT. VSL RESTRICTED TO DAYLIGHT OPERATIONS UNTIL COMPLETED. LEGACY COMPONENT DESC: Navigation Lights
Due 27 April 2002
Resolved 25 April 2002
Communications › Alarms/Indicators
Issued 25 April 2002 Resolved
PROVIDE VISUAL INDICATING LIGHT FOR SECOND HIGH WATER ALARM. LEGACY COMPONENT DESC: High Water Alarm
Due 25 May 2002
Resolved 30 April 2002
Fire Fighting
Issued 21 April 2000 Resolved
SERVICE FIRE EXTINGUISHERS: 1 BI AND 1 BII.
Condition: Unknown
Due 21 May 2000
Resolved 1 June 2000
Lifesaving
Issued 21 April 2000 Resolved
PROVIDE PFD DONNING PLACKARD.
Condition: Unknown
Due 21 May 2000
Resolved 1 June 2000
Lifesaving
Issued 21 April 2000 Resolved
PROVIDE PADDLES FOR LIFE FLOAT.
Condition: Unknown
Due 21 May 2000
Resolved 1 June 2000
Documentation
Issued 21 April 2000 Resolved
POST STABILITY LETTER.
Condition: Unknown
Due 21 May 2000
Resolved 1 June 2000
Navigation
Issued 21 April 2000 Resolved
PROVIDE CURRENT CHARTS, LOG BOOK AND COPY OF 46 CFR PARTS 166 THRU 199.
Condition: Unknown
Due 21 May 2000
Resolved 1 June 2000
Engineering
Issued 21 April 2000 Resolved
LABEL EMER FUEL SHUT OFF AND PROVIDE QUICK ACCESS.
Condition: Unknown
Due 21 May 2000
Resolved 1 June 2000
Lifesaving
Issued 21 April 2000 Resolved
REPLACE LIFE FLOAT WATER LIGHT ON 18' LINE.
Condition: Unknown
Due 21 April 2000
Resolved 1 June 2000
Lifesaving
Issued 21 April 2000 Resolved
PROVIDE CG APPROVED WATER LIGHT ON RING BUOY ON 3' TO 6' LINE WITH SNAP HOOK.
Condition: Unknown
Due 21 May 2000
Resolved 1 June 2000
Lifesaving
Issued 21 April 2000 Resolved
PROVIDE 60' 5/16" BUOYANT SUN RESISTANT LINE ON RING BUOY.
Condition: Unknown
Due 21 May 2000
Resolved 1 June 2000
Lifesaving
Issued 21 April 2000 Resolved
UPDATE FIRST AID KIT.
Condition: Unknown
Due 21 May 2000
Resolved 1 June 2000
Documentation
Issued 21 April 2000 Resolved
OBTAIN FCC SAFETY CERTIFICATE AND OPERATOR LIC.
Condition: Unknown
Due 1 June 2000
Resolved 1 June 2000
Construction/Loadline
Issued 8 May 1999 Resolved
PROVIDE KEEL COOLER SHUT-OFF VALVES AS PER 46 CFR 182.422.
Condition: Unknown
Due 8 May 1999
Resolved 8 May 1999

Ownership record