MAURY USCG vessel records Sign in
← All vessels

INDIAN II

INDIAN II is a 1977 passenger vessel (inspected). The Coast Guard has recorded 51 inspections since 1985, most recently in April 2007, along with 118 deficiencies.

Records from 1985 to 2007. Most recent: inspection, 24 April 2007.

Built
1977
Last inspected
24 April 2007
Documentation
No Operation - PM · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDC5136
Flag
UNITED STATES
367036380 (licence lapsed)
Maury page id
psix-49170

Inspections, by type

…with no type recorded7
Years with a record 23 calendar years (1985–2007)
The 51 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 19 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)53.0 ft × 115.8 ft × 6.3 ft
Registered tonnagegross 35 / net 29
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · KENNEBUNK, ME, UNITED STATES · built 1977
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORTLAND, ME
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationNo Operation - PM · issued 27 March 2006 · expires 30 April 2007
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it29 - Regulatory (Subpart C or D), Net Ton
35 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDC5136MMSI 367036380 · expired · compulsorily equipped · granted 23 April 2005, cancelled 27 June 2015
WCZ9383MMSI not assigned · expired · compulsorily equipped · granted 14 July 2000, cancelled 18 September 2010
WCR8420MMSI not assigned · expired · compulsorily equipped · granted 25 May 1995, cancelled 30 July 2005
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 51

24 April 2007 Hull Examination
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2914675
15 June 2006 Re-Inspection
Physical examination · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 2680311
13 May 2005 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2359208
25 April 2005 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2340743
20 May 2004 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2072744
9 May 2003 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1790097
13 June 2002 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1630519
14 May 2001 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1063719
21 March 2001 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1461371
27 April 2000 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1051032
2 August 1999 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 773725
19 July 1999 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1101749
20 June 1999 COI Inspection · Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1434839
17 June 1999 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 811418
14 April 1999 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 789206
16 August 1998 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 157634
27 April 1998 COI Inspection · Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 790197
19 May 1997 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1464037
22 April 1997 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1418120
7 June 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 875246
24 May 1996 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1085972
6 May 1996 Deficiency Check · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1459223
31 July 1995 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 872804
1 June 1995 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 879891
12 May 1995 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1382959
1 May 1995 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 891047
26 April 1995 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 861861
17 April 1995 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1175101
15 August 1994 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1176042
19 May 1994 MARPOL Annex V Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1021645
18 July 1993 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 64407
7 June 1993 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 834232
21 April 1993 Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 841026
11 August 1992 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 124068
21 April 1992 Deficiency Check
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1256083
10 April 1992 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1011936
15 July 1991 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 935620
10 April 1991 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1242168
10 May 1990 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1229545
16 April 1990 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 925277
13 April 1989 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 897418
6 May 1988 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1197965
6 May 1988 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1346453
27 January 1988 Hull Examination
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1321597
27 January 1988 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1322576
30 December 1987 Administrative
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1008396
29 June 1987 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1316743
13 May 1987 Re-Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1331830
10 April 1986 COI Inspection
Physical examination · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 999519
3 April 1986 Credit Drydock
Administrative · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1307248
17 April 1985 Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 1290093

Deficiency record · 118

Construction/Loadline › Hull › Longitudinal Frame
Issued 1 May 2007 Resolved
Replace portside deck clamp beginning at the bow and continuing until good wood is met.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Side Shell
Issued 1 May 2007 Resolved
Port and starboard chine clamp, renew to original entire length
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Transverse Frame
Issued 1 May 2007 Resolved
Remove sisters and replace all transverse beams in forward compartment. Beams are rotten and sisters were used to shore up rotten beams.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Strut/Cross Tie
Issued 1 May 2007 Resolved
Rebolt in good wood, shaft struts. Several bolts are missing
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Side Shell
Issued 1 May 2007 Resolved
Remove copper strapping port and starboard bow to all for further inspection
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 June 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Keel
Issued 1 May 2007 Resolved
Install keepers or double-nut rudder cross arm
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 18 August 2008
Construction/Loadline › Structures › Machinery Space Opening
Issued 1 May 2007 Resolved
Bring to good wood port and starboard engine exhaust ports
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 June 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Longitudinal Frame
Issued 24 April 2007 Resolved
Recaulk main deck edge entire length of vessel port and stbd side including seams as pointed out by CG Marine Inspector.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Resolution: Vessel destroyed Summer 2007.
Construction/Loadline › Hull › Bottom Plating
Issued 24 April 2007 Resolved
Conduct underway check ride
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Keel
Issued 24 April 2007 Resolved
Clean engine room bilges to expose all keel bolts for inspection
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Keel
Issued 24 April 2007 Resolved
Remove plywood flooring in lazerette to provide for inspection of keel bolts underneath.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Penetrations › Pipe Flange
Issued 24 April 2007 Resolved
Remove port and stbd engine exhaust ports to provide for further inspection
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Penetrations › Weld
Issued 24 April 2007 Resolved
Repair loose starboard rudder.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Penetrations › Valve Flange
Issued 24 April 2007 Resolved
Repair or renew throughhull fittings and pointed out by CG Marine Inspector.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Hull Plating
Issued 24 April 2007 Resolved
Replace fastener/recaulk seam on starboard plank above chine as pointed out by CG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 24 April 2007
Construction/Loadline › Hull › Side Shell
Issued 24 April 2007 Resolved
Replace starboard bow plank underneath rub-rail as pointed out by CG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Hull Plating
Issued 24 April 2007 Resolved
At stem, Clean to good wood, repair existing holes, and refasten loose pulpit brace.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Side Shell
Issued 24 April 2007 Resolved
Renew/repair two portside bow planks underneath rub rail as pointed out by CG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Side Shell
Issued 24 April 2007 Resolved
Reseam/recaulk areas marked on hull by CG Marine Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Side Shell
Issued 24 April 2007 Resolved
Rebung missing bungs
Condition: Unknown
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Structures › Deck Plating
Issued 24 April 2007 Resolved
Bring to good wood port and starboard transom corners.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Keel
Issued 24 April 2007 Resolved
Replace broken keel bolt as pointed out by CG Marine Inspector and provide proposal to CG to prove satisfactory condition of all remaining keel bolts.
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Construction/Loadline › Hull › Stiffener
Issued 24 April 2007 Resolved
Repair/renew forward compartment starboard side deck clamp
Action required: 705 - Other - as specified
Due 24 May 2007
Resolved 18 August 2008
Communications › Radio Communications › EPIRB
Issued 13 May 2005 Resolved
EPIRB sent out for service, awaitng return. Restricted vessel operations to within 3 miles from land pending reinstallation.
Due 20 May 2005
Resolved 20 May 2005
Resolution: EPIRB reinstalled.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 20 May 2004 Resolved
Add updated first aid kit.
Due 27 May 2004
Resolved 21 May 2004
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 20 May 2004 Resolved
Replace 3 adult type I pfds. Vessel limited to 47 adults pending replacement.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 May 2004
Resolved 21 May 2004
Construction/Loadline › Hull › Stringer
Issued 9 May 2003 Resolved
REMOVE KEEPER FROM STBD AND PORT SIDE FOR INSPECTION AND RECAULK
Condition: Unknown
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 9 May 2003
Resolution: REMOVED AND RECAULK KEEPER, ALL SAT
Engineering › Lubricating Oil Service System › Piping
Issued 9 May 2003 Resolved
REPAIR HYDRAULIC OIL LEAK ON PIPE LEADING TO BRIDGE IN MAIN COMPARTNMENT
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 9 May 2003
Resolution: REPLACED PIPE FITTING AND TIGHTENED
Electrical › Electric Supply System (service)
Issued 9 May 2003 Resolved
REMOVE ALL DEADEND WIRES ON VESSEL IN PARTICULAR LAZERETTE AND ENGINROOM LEGACY COMPONENT DESC: LOOSE DEAD END WIRES
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 9 May 2003
Resolution: REMOVED ALL DEAD END WIRE AND NEATED UP COMPARTMNETS
Engineering › Diesel Engine (propulsion-direct drive)
Issued 9 May 2003 Resolved
U/W/CHECKRIDE PRIOR TO CARRYING PASSENGERS FOR HIRE LEGACY COMPONENT DESC: U/W PORTION OF INSPECTION
Action required: 705 - Other - as specified
Due 9 May 2003
Resolved 9 May 2003
Resolution: U/W PORTION OF HULL COMPLETE
Personnel › Training
Issued 9 May 2003 Resolved
PROVIDE 50% OF CREW WITH CPR/FIRST AID TRAINING LEGACY COMPONENT DESC: First Aid/CPR
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 15 May 2003
Resolution: CREW TRAINED IN CPR/FIRST AID
Operations/Management › Drug and Alcohol Testing
Issued 9 May 2003 Resolved
PROVIDE PROOF OF CHEMICAL TESTING PROGRAM TO LOCAL MSO. LEGACY COMPONENT DESC: Proof of Enrollment
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 15 May 2003
Resolution: [withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation › Piloting/Steering
Issued 9 May 2003 Resolved
PROVIDE UPDATED DEVIATION CARD. LEGACY COMPONENT DESC: Deviation Table/Graph
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 15 May 2003
Resolution: OWNER SWUNG COMPASS AND PROVIDED NEW DEVIATION CARD
Lifesaving › Lifejacket/PFD (General)
Issued 9 May 2003 Resolved
PROVIDE TWO ADDITIONAL PFD'S PRIOR TO CARRYING PASSENGERS. LEGACY COMPONENT DESC: Quantity
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 15 May 2003
Resolved 15 May 2003
Resolution: 2 PFDS PROCURED AND PLACED ON BOARD
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 13 June 2002 Resolved
REPLACE BOTH BII EXTINGUISHERS IN MAIN CABIN
Condition: Improper/Lack of Maintenance
Due 13 June 2002
Resolved 13 June 2002
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 13 June 2002 Resolved
PROVIDE MEANS OF CLOSURE IN CASE OF FIRE FOR MAIN ENGINEROOM VENTS LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Due 17 June 2002
Resolved 28 June 2002
Electrical › Electrical Distribution System (service)
Issued 13 June 2002 Resolved
PROPERLY MAKE UP WIRES IN TRUNK LEGACY COMPONENT DESC: Wiring
Condition: Improper/Lack of Maintenance
Due 28 June 2002
Resolved 28 June 2002
Engineering › Fuel Oil Storage/Transfer System
Issued 13 June 2002 Resolved
RENEW OR PROVE TIGHT DIESEL OIL TANK LEGACY COMPONENT DESC: Tank
Condition: Improper/Lack of Maintenance
Due 17 June 2002
Resolved 28 June 2002
Resolution: New aluminum fuel tank installed.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 13 June 2002 Resolved
PROPERLY MAKE UP BOTH MAIN ENGINE SHUT DOWN SOLENIODS LEGACY COMPONENT DESC: Operating Controls
Condition: Improper/Lack of Maintenance
Due 28 June 2002
Resolved 28 June 2002
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 13 June 2002 Resolved
RENEW ALL UNSERVICABLE LIFE JACKETS
Condition: Improper/Lack of Maintenance
Due 13 June 2002
Resolved 13 June 2002
Lifesaving › Lifejacket/PFD (General)
Issued 13 June 2002 Resolved
PROVIDE MARKER LIGHTS FOR ALL PFD's VESSEL MAY NOT OPERATE ON AN OCEAN ROUTE UNTIL CORRECTED. LEGACY COMPONENT DESC: Lights
Condition: Improper/Lack of Maintenance
Due 8 July 2002
Resolved 8 July 2002
Fire Fighting
Issued 14 May 2001 Resolved
PROVIDE VENT CLOSURE PLUGS FOR ENGINE ROOM VENTS.
Condition: Unknown
Due 15 May 2001
Resolved 17 May 2001
Lifesaving
Issued 14 May 2001 Resolved
PROVIDE ONE ADDITIONAL WATERLIGHT FOR LIFE FLOATS.
Condition: Unknown
Due 14 May 2001
Resolved 17 May 2001
Fire Fighting
Issued 14 May 2001 Resolved
INSPECT SYSTEM TO ENSURE ENGINE SHUT DOWN SYSTEM WORKS CORRECTLY.
Condition: Unknown
Due 14 May 2001
Resolved 17 May 2001
Construction/Loadline
Issued 21 March 2001 Resolved
GET U/W WITH MI TO ASSESS WATERTIGHT INTEGRITY OF VESSEL PRIOR TO THE CARRIAGE OF PASSENGERS.
Condition: Unknown
Due 20 April 2001
Resolved 20 April 2001
Lifesaving
Issued 27 April 2000 Resolved
RENEW 01 ADULT PFD
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Lifesaving
Issued 27 April 2000 Resolved
PROVIDE 01 ADDITIONAL ADULT PFD WITH LIGHT
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Lifesaving
Issued 27 April 2000 Resolved
RENEW LIGHT ON 01 ADULT PFD _x001C_
Condition: Unknown
Due 27 April 2000
Resolved 27 April 2000
Construction/Loadline
Issued 19 July 1999 Resolved
MAKE PERMANENT REPAIR TO THE LEAK(S) IN THE FOREPEAK. VSL MASTER SHALL MONITOR THE ABOVE CONDITION. IF ANY SIGNIFICANT CHANGES OCCUR, THE OCMI SHALL BE NOTIFIED IMMEDIATELY.
Condition: Unknown
Due 19 July 1999
Resolved 19 July 1999
Lifesaving
Issued 20 June 1999 Resolved
Replace the becket on the lifefloat.
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Lifesaving
Issued 20 June 1999 Resolved
Add amonia inhalents and a splint to the first aid kit.
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Electrical
Issued 20 June 1999 Resolved
Properly splice the wiring for the engine room float switch.
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Construction/Loadline
Issued 20 June 1999 Resolved
Add a bilge alarm to the forepeak.
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Electrical
Issued 20 June 1999 Resolved
Properly splice wiring for forepeak bilge pump.
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Accommodation/Occupational Safety
Issued 20 June 1999 Resolved
Repair leak in holding tank.
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Lifesaving
Issued 20 June 1999 Resolved
Add 3 smoke signals to flare kit for a total of 6.
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Construction/Loadline
Issued 20 June 1999 Resolved
Get underway with a Coast Guard inspector on or about 19 July 1999 to inspect the stem area for possible leaks.
Condition: Unknown
Due 20 June 1999
Resolved 20 June 1999
Fire Fighting
Issued 20 June 1999 Resolved
Repair fire pump clutch.
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Fire Fighting
Issued 20 June 1999 Resolved
Repair leak in fire hydrant
Condition: Unknown
Due 20 June 1999
Resolved 21 June 1999
Navigation
Issued 27 April 1998 Resolved
Provide nautical publications and chart corrections for areas on Certificate of Inspection.
Condition: Unknown
Due 6 May 1998
Resolved 6 May 1998
Lifesaving
Issued 27 April 1998 Resolved
Place 3'-6' u/v protected lanyard for the life float to the waterlight.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Lifesaving
Issued 27 April 1998 Resolved
Place a 60' painter that is u/v protected on life ring.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Navigation
Issued 27 April 1998 Resolved
Place a log on board that contains crew training, conducting of emergency drills, and the logging of monthly EPIRB tests.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Documentation
Issued 27 April 1998 Resolved
PROVIDE PROPER DOCUMENTATION OF FULLY COMPLIANT CHEMICAL TESTING. MARINE EMPLOYER IS NOT AUTHORIZED TO OPERATE AFTER 27 MAY 98 UNLESS THIS REQUIREMENT HAS BEEN CLEARED TO THE SATISFACTION OF AN ATTENDING USCG MARINE INSPECTOR.
Condition: Unknown
Due 14 May 1998
Resolved 14 May 1998
Electrical
Issued 27 April 1998 Resolved
Clean-up electrical wires in the switchboard and engine room IAW 46 CFR 183.
Condition: Unknown
Due 29 April 1998
Resolved 29 April 1998
Construction/Loadline
Issued 22 April 1997 Resolved
REPAIR FOLLOWING LEAKS:(A)FOREPEAK IN WAY OF STEM AT HEIGHT OF RUB RAIL (B)RUB RAIL BOLT IN MSD SPACE,PORTSIDE,NEAR 2ND FRAME AFT OF FWD BULKHEAD &UNDER CHINE CLAMP STBD SIDE OF MSD SPACE AFT OF FWD BULKHEAD TO FRAME #4. PROHIBITED FROM CARRYING PASSENGERS UNTIL REPAIRS MADE TO SAT OF USCG INSP.
Condition: Unknown
Due 23 April 1997
Resolved 5 May 1997
Documentation
Issued 6 May 1996 Resolved
PROVIDE COAST GUARD MARINE INSPECTOR WITH DRUG TESTING INFORMATION FOR LASTOPERATING SEASON (FY 95)._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1996
Resolved 14 May 1996
Lifesaving
Issued 6 May 1996 Resolved
PROVIDE VESSEL WITH PFD DONNING PLACARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1996
Resolved 24 May 1996
Lifesaving
Issued 6 May 1996 Resolved
VESSEL REQUIRED TO GET UNDERWAY FOR EMERGENCY DRILLS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 May 1996
Resolved 24 May 1996
Lifesaving
Issued 6 May 1996 Resolved
REPAIR LIFE LINES ON LIFE FLOAT._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1996
Resolved 24 May 1996
Lifesaving
Issued 6 May 1996 Resolved
VESSEL RESTRICTED TO 45 PASSENGER UNTIL 3 PFDS ARE PROVIDED FOR COASTWISE ROUTE REQUIRMENT FOR A TOTAL OF TOTAL (50),ALLOWED BY THE COI._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 May 1996
Resolved 24 May 1996
Lifesaving
Issued 6 May 1996 Resolved
VESSEL RESTRICTED TO NO MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL AN EPIRB HAS BEEN PLACED ONBOARD AND INSPECTED BY A CG MARINE INSPECTOR._x001C_ _x001C_
Condition: Unknown
Due 6 May 1996
Resolved 6 May 1996
Fire Fighting
Issued 6 May 1996 Resolved
PROVIDE VESSEL WITH HAND FIRE/BILGE PUMP THAT CAN BE USED FOR BOTH SITUATIONS._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 30 May 1996
Resolved 24 May 1996
Navigation
Issued 6 May 1996 Resolved
UPDATE CHART # 13290,13286 WITH LATEST NOTICE TO MARINERS CORRECTIONS._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 25 May 1996
Resolved 24 May 1996
Accommodation/Occupational Safety
Issued 12 May 1995 Resolved
AFT CABIN DOOR NEEDS DOOR HANDLE
Condition: Unknown
Due 12 May 1995
Resolved 12 May 1995
Documentation
Issued 1 May 1995 Resolved
RENEW FCC LIC. PRESENT ONE EXPIRED ON 02-27-95_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Fire Fighting
Issued 1 May 1995 Resolved
BI FIRE EXTINGUISHER REQUIRES BRACKET ON BRIDGE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1995
Resolved 12 May 1995
Engineering
Issued 1 May 1995 Resolved
REHANG EXHAUST HANGER FOR STARBOARD ENGINE EXHAUST LINE TO SUPPORT EXHAUST._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1995
Resolved 12 May 1995
Engineering
Issued 1 May 1995 Resolved
PUT CHAFEING GEAR ON RETURN FUEL LINE FOR STARBOARD ENGINE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1995
Resolved 12 May 1995
Construction/Loadline
Issued 1 May 1995 Resolved
EXHAUST VENT DUCKING REQUIRED TO REACH BOTTOM OF 1/3 OF BILGE AREA._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 1 May 1995
Resolved 1 May 1995
Fire Fighting
Issued 1 May 1995 Resolved
REPLACE HAND FIRE PUMP WITH PUMP THAT CAN BE USED TO DRAW FROM WATER SOURCEAND BILGE AREA. PUMP LENGTH NOT LONG ENOUGH FOR DRAW._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1995
Resolved 12 May 1995
Electrical
Issued 1 May 1995 Resolved
POWER PANEL IN CABIN BREAKER FOR BILGE PUMP IN STEERING COMPARTMENT REQUIRES LABELING._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1995
Resolved 12 May 1995
Electrical
Issued 1 May 1995 Resolved
POWER PANEL IN BRIDGE REQUIRES LABEL FOR SPARE VHF ON BREAKER._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1995
Resolved 12 May 1995
Lifesaving
Issued 1 May 1995 Resolved
STORAGE BOX ON FANTAIL FOR PFD REQUIRE STENCILING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1995
Resolved 12 May 1995
Lifesaving
Issued 1 May 1995 Resolved
PFD STORAGE IN CABIN OVERHEAD REQUIRES STENCILING._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 May 1995
Resolved 12 May 1995
Construction/Loadline
Issued 26 April 1995 Resolved
PARTIAL DECK SUPPORTS ON OVERHEAD_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Construction/Loadline
Issued 26 April 1995 Resolved
STRINGERS FOR DECK SUPPORT IN ENGINE ROOM COMPARTMENT AT FRAMES #4,6,7 ON STARBOARD, AND AT FRAME #5,6,7 ON PORT SIDE._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Construction/Loadline
Issued 26 April 1995 Resolved
12FT ROTTED DECK PLANK PORT SIDE AFT_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Navigation
Issued 26 April 1995 Resolved
PORT AND STARBOARD RUDDERS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Construction/Loadline
Issued 26 April 1995 Resolved
10FT SECTION OF WORM SHOE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 26 April 1995
Resolved 26 April 1995
Navigation
Issued 19 May 1994 Resolved
FWD NAV LIGHT IS CURRENTLY OBSTRUCTED AT FORWARD SWEEP DUE BRIM ON CABIN TOP. CORRECT TO COMPLY WITH COLREGS. NO REDUCED VISIBILITY OPS UNTIL CORRECTED.
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Engineering
Issued 19 May 1994 Resolved
REPLACE FUEL VENT SCREEN, CURRENTLY HOLED
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Engineering
Issued 19 May 1994 Resolved
REPAIR STBD ENG GOVERNOR CONTROL, SURGES WITHOUT WARNING WHEN COLD
Condition: Unknown
Due 19 May 1994
Resolved 19 May 1994
Engineering
Issued 21 April 1993 Resolved
PROVIDE FLAME GUARD AROUND FUEL CUT OUT VALVE.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Lifesaving
Issued 21 April 1993 Resolved
INSTALL PROPER WEAK LINK AND RETRO-TAPE ON BOUYANT APPARATUS. ROUTE RESTRICTED TO ONE(01) MILE UNTIL CORRECTED.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Navigation
Issued 21 April 1993 Resolved
SECURE RAM ATTACHMENT BLOCK AND FULLY INSERT COTTER PIN.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Navigation
Issued 21 April 1993 Resolved
INSTALL PROPER BULB IN PORT RUNNING LIGHT, NO REDUCED VISIBILTY OPERATIONS UNTIL CORRECTED.
Condition: Unknown
Due 21 April 1993
Resolved 21 April 1993
Lifesaving
Issued 10 April 1992 Resolved
REPLACE 8 WATERLIGHTS ON PFD'S. VESSEL RESTRICTED TO 17 PERSONS (15 PASS) WHEN OPERATING ON THE OCEAN'S ROUTE UNTIL REPLACEMENT COMPLETE.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Fire Fighting
Issued 10 April 1992 Resolved
REPLACE FIRE HOSES PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Engineering
Issued 10 April 1992 Resolved
MAKE PERMANENT REPAIRS TO STBD ENGINE TRANSMISSION DRIVE LINKAGE.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Fire Fighting
Issued 10 April 1992 Resolved
REPLACE PLASTIC ELBOW ON FIRE HOSE CONNECTION AT BULKHEAD WITH STEEL OR BRASS.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Fire Fighting
Issued 10 April 1992 Resolved
REPLACE FIRE HOSE CONNECTION, HOSE AND GALVENIZED PIPE AT BULKHEAD.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Navigation
Issued 10 April 1992 Resolved
MAKE PERMANENT REPAIRS TO SSB RADIO PRIOR TO OPERATING ON THE OCEAN'S ROUTE.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Lifesaving
Issued 10 April 1992 Resolved
REPLACE 1 ADULT PFD. VESSEL LIMITED TO 49 TOTAL PERSONS (47 PASS) WHILE OPERATING ON A LAKES, BAYS & SOUNDS ROUTE UNTIL REPLACEMENT COMPLETE.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Lifesaving
Issued 10 April 1992 Resolved
STENCIL VESSEL NAME ON RING BUOY.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Lifesaving
Issued 10 April 1992 Resolved
REPLACE CLASS A EPIRB WITH CLASS A MANUFACTURED AFTER OCT 1988 OR 406 MHZ CAT 1/2. VESSEL RESTRICTED TO LAKES, BAYS & SOUNDS ROUTE UNTIL EPIRB IS REPLACED.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Construction/Loadline
Issued 10 April 1992 Resolved
CLEAN ENGINEROOM BILGES.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Engineering
Issued 10 April 1992 Resolved
INSTALL DOUBLE CLAMPS ON AFT END OF BOTH EXHAUST HOSES.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Construction/Loadline
Issued 10 April 1992 Resolved
REPAIR AFT DECK HATCH AND MAKE WEATHER TIGHT.
Condition: Unknown
Due 10 April 1992
Resolved 10 April 1992
Navigation
Issued 13 April 1989 Resolved
RENEW WASTED PORTIONS OF STEERING SUPPORT BRACKET.
Condition: Unknown
Due 13 April 1989
Resolved 13 April 1989
Electrical
Issued 13 April 1989 Resolved
PERMANENTLY MOUNT ELECTRICAL BOX ALONG SIDE PORT ENGINE ALTERNATOR.
Condition: Unknown
Due 13 April 1989
Resolved 13 April 1989
Construction/Loadline
Issued 13 April 1989 Resolved
MAKE PERMANENT REPAIR TO COLLSION BULKHEAD.
Condition: Unknown
Due 13 April 1989
Resolved 13 April 1989
Engineering
Issued 13 May 1987 Resolved
REPLACE WITH APPROVED HOSE AND FITTINGS, THE FUEL HOSE BETWEEN LAST FILTER AND ENGINE ON BOTH MAIN ENGINES.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Engineering
Issued 13 May 1987 Resolved
REPAIR EMERGENCY FUEL SHUTOFF ON STARBOARD FUEL TANK.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Fire Fighting
Issued 13 May 1987 Resolved
INSTALL BELT ON ENGINE DRIVEN FIRE AND BILGE PUMP.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Navigation
Issued 13 May 1987 Resolved
INSTALL ADDITIONAL PIPE HANGERS ON HYDRAULIC LINES IN STEERING COMPARTMENT.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Engineering
Issued 13 May 1987 Resolved
INSTALL PIPE HANGERS ON STARBOARD ENGINE COOLING WATER LINE.
Condition: Unknown
Due 13 May 1987
Resolved 13 May 1987
Navigation
Issued 17 April 1985 Resolved
INSTALL SINGLE SIDE BAND VHF TO COMPLY WITH FCC REQUIREMENTS FOR VESSEL'S ROUTE AND PROVIDE FCC SAFETY CERTIFICATE FOR NEW STATION. VESSEL IS RESTRICTED TO NOT MORE THAN 20 MILES FROM A HARBOR OF SAFE REFUGE UNTIL THIS REQUIREMENT IS COMPLIED WITH.
Condition: Unknown
Due 17 April 1985
Resolved 17 April 1985

Ownership record