← All vessels
JACQUES JACOB
JACQUES JACOB is a 2000 tank ship. The Coast Guard has recorded 39 inspections since 2000, most recently in October 2016, along with 19 deficiencies and 6 operational controls.
Records from 2000 to 2016. Most recent: inspection, 8 October 2016.
- Built
- 2000
- Last inspected
- 8 October 2016
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 19 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9164201 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ZDKG7
4918
Flag
GIBRALTAR
—
Maury page id
psix-4918
Inspections, by type
…with no type recorded16
Years with a record
14 calendar years (2000–2016)
The 39 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it71345 - Dead Weight, Metric Ton
86900 - Displacement, Metric Ton
40705 - Convention (Subpart B), Gross Ton
21529 - Convention (Subpart B), Net Ton
86900 - Displacement, Metric Ton
40705 - Convention (Subpart B), Gross Ton
21529 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 39
8 October 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6018777
21 December 2015
Ballast Water Examination · COC-TVE Renew · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5781868
12 October 2014
Ballast Water Examination · ISPS II Exam · COC-TVE Annual
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4999220
29 June 2014
COE-Administrative
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4903760
24 January 2011
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3932159
21 September 2010
COC-TVE Annual · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3846806
27 July 2009
Deficiency Check · PI Safety Exam · ISPS III Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3547464
25 July 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3545497
25 July 2009
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3548929
11 May 2009
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 3472639
6 April 2009
Administrative Inspection
Administrative · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3448473
6 December 2008
MARPOL Annex V Examination · COC-TVE Annual · MARPOL Annex I Examination · ISPS II Exam · Ballast Water Examination
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3370969
2 August 2008
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3286826
26 November 2007
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3103919
25 September 2007
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3065818
14 September 2007
Ballast Water Examination · ISPS II Exam · COC-TVE Renew · MARPOL Annex I Examination
Physical examination · Resident Inspection Office St. Croix · USCG Southeast District (CGD-SE) · Activity 3059672
13 September 2007
ISPS II Exam · COC-TVE Renew · Ballast Water Examination · MARPOL Annex I Examination
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 3056910
13 October 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2799899
12 October 2006
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2799635
6 September 2006
COC-TVE Annual · ISPS II Exam · Ballast Water Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2771035
13 March 2006
Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 2601864
8 March 2006
ISPS II Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2595834
7 December 2005
Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2547562
18 August 2005
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2466903
26 July 2005
Ballast Water Examination · COC-TVE Renew
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2440240
25 July 2005
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2439933
7 March 2005
PII Safety Exam · Random ISPS/MTSA/PSC
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2304794
5 March 2005
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2305158
17 November 2004
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 2243716
16 August 2004
Type not recorded
No type recorded · MSO PORTLAND MAINE · USCG Northeast District (CGD-NE) · Activity 2167301
16 July 2004
ISPS II Exam · COC-TVE Annual
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2129221
6 January 2004
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1988219
20 November 2002
Ballast Water Examination · Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1706599
26 March 2002
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1597734
15 September 2001
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1071377
18 June 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 291345
21 July 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 768299
16 July 2000
Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 198347
15 May 2000
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 277882
Deficiency record · 19
Lifesaving › Lifeboat › Propulsion Engine
Issued 21 December 2015
Resolved
0610-Lifeboats- Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Vessel's lifeboat engine started initially but shutdown during propulsion test. Crew was unable to re-start lifeboat engine after multiple attempts. SOLAS 74 am III/20
Lifesaving › Rescue Boat › Propulsion Engine
Issued 21 December 2015
Resolved
0615-Rescue Boats- Before the ship leaves port and at all times during the voyage, all lifesaving appliances shall be in working order and ready for immediate use. Vessel's rescue boat engine failed to start during PSC inspection. Multiple attempts were tried using electrical means to no avail but pull start method worked as second means. SOLAS 74 am III/20
Electrical › Electrical Distribution System (service) › Grounding Conductor
Issued 27 July 2009
Resolved
1800- Numerous ground wires for the exterior light fixtures on the house are deteriorated and wasted. Class to verify renewal / reconnection. ISGOTT CH-3 (17abc)
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 27 July 2009
Resolved
0750- Numerous self closing fire doors do not close completely and latch. Door for A/C room is stenciled -keep open and has a hold back device. Doors include purifier room, E/R to passageway at Incinerator, stair tower to passageway at main deck level. (17abc)
Fire Fighting › Portable Foam Applicators › General
Issued 27 July 2009
Resolved
0720- Twenty liter foam cans in the four engine room fire fighting foam stations do not have testing certificates. One container is dated, May 2001. (17abc)
Lifesaving › Rescue Boat › Propulsion Engine
Issued 27 July 2009
Resolved
0615- Rescue boat flexible fuel hose for outboard engine is dry rotted and cracked by primer bulb and inline fuel filter. (17abc)
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 27 July 2009
Resolved
2199- Sewage system is not being maintained IAW the manufacturers operating procedures. Chlorine tablet levels are not being maintained and weekly chlorine levels are not being tested and recorded. (70ab) MARPOL IV/9, ISM A-2
Documentation › Logs/Records › Garbage Recordkeeping
Issued 27 July 2009
Resolved
2120- Garbage Management Plan is not being followed. Numerous containers throughout the ship are not color coated per the plan. Mixed garbage was found in numerous containers inside the ship and at final collection point for at sea disposal indicating that plastic and cigarette butts are being disposed of at sea. (70ab) ISM A-2
Documentation › Certificates/Documents › Cargo Ship Safety Construction Certificate
Issued 17 September 2007
Resolved
SOLAS Safety Equipment, Radio, and Construction certs have incorrect keel laid dates.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 17 September 2007
Resolved
Oxygen testing meter onboard for testing cargo tanks is expired in August 07. New test meter is enroute and will be onboard in Port Everglades.
Deck/Cargo › Holds/Tanks › Portable Gas Measuring Equipment
Issued 13 September 2007
Resolved
Oxygen testing meter onboard for testing cargo tank is expired in August 07.
Documentation › Certificates/Documents › Cargo Ship Safety Equipment Certificate
Issued 13 September 2007
Resolved
SOLAS certificates show different keel laid dates.
Documentation › Certificates/Documents › Cargo Ship Safety Certificate
Issued 13 September 2007
Resolved
Owner on Continuous Synopsis Record is incorrect. Class to fax report to Sector Miami.
Construction/Loadline › Markings › Load Line Mark
Issued 6 September 2006
Resolved
The Vessel's loadline on the Starboard side has been painted and is not permanently marked. The vessel's port loadline is no longer visibleand in a contrasting color. The loadline certificate doesnt match the markings on the vessel.
Operations/Management › Pollution › Control of Garbage
Issued 6 September 2006
Resolved
The Ships garbage management plan is not in accordance with the "Guidelines for the Developement of Garbage Management Plan"- MECP 70(38) as incorporated by reference by MARPOL V/9. The plan doesnt have ship specific procedures and garbage was found to be mixed throughout the ship.
Navigation › Piloting/Steering › US Coast Pilot
Issued 26 July 2005
Resolved
Corrections to Coast Pilot 8 are not being recorded inside the front cover.
Documentation › Logs/Records › Ballast Water Logs/Records
Issued 26 July 2005
Resolved
Ballast Water management plan not ship specific. Total numbers of tanks, pumps, sediment removal and the items addressed in the IMO resolution have not been identified.
Documentation › Logs/Records › Garbage Recordkeeping
Issued 26 July 2005
Resolved
Garbage Plan is not ship specific for the collecting, disposal and incineration of garbage.
Electrical › Lighting (emergency) › Conductor
Issued 16 July 2004
Resolved
Emergency battery room has A/C ducting passing above that drips condensation on top of the Emergency Batteries. Prevent condensation from A/C ducting to collect on top of batteries. SOLAS 2001 Ch. 11 Reg. 45 1.3. A50
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.