MAURY USCG vessel records
← All vessels

LARISSA ANN

Built
1977
Last inspected
9 December 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 9 December 2025
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDE5195
Flag
UNITED STATES
Maury page id
psix-49180

Documentation record

Registered dimensions (L × B × D)44.8 ft × 14.0 ft × 6.2 ft
Registered tonnagegross 26 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE, LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN PEDRO, CA
Endorsements, as the file codes themcw_un
DocumentationValid · issued 8 April 2026 · expires 31 May 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it26 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 19 inspections, each with its date, unit and type; 11 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 19

9 December 2025 Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8197739
16 June 2025 COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8110330
18 September 2024 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8013368
17 September 2024 Damage Survey · Deficiency Check · Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7976653
18 October 2023 Deficiency Check · Internal Structural Exam · Damage Survey · Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7790569
14 September 2023 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7758256
11 August 2022 Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7492383
17 June 2022 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7480290
1 December 2021 Internal Structural Exam · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7360226
11 August 2021 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7283598
29 July 2020 Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7117974
18 June 2020 Deficiency Check · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6978521
23 April 2020 Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6942979
24 September 2019 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6820285
2 July 2019 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6679148
30 May 2018 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6388220
28 November 2017 Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6296440
31 May 2017 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6132693
25 April 2016 Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5854123

Deficiency record · 11

02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 17 September 2024 Resolved
A vessel must be provided with a main steering gear that is of adequate strength and capable of steering the vessel at all service speeds. STBD tiller arm that connects to rudder post and hydraulic ram was found wasted. Provide plan to MI to repair or replace tiller arm, plan shall be approved by MI prior to any work.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 October 2024
Resolved 4 October 2024
Resolution: Tiller arm replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 September 2024 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. Vessel operator reported a sheen emitting from the wet exhaust system overboard discharge. Operator secured STBD engine and returned to dock under the power of Port engine. STBD engine was believed to be leaking fuel into raw water cooling system by way of fuel heat exchanger. Repair/replace damaged components to prevent any future discharge of fuel or oil and conduct underway sea trial with attending Marine Inspector following repairs.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 September 2024
Resolution: Transmission heat exchanger replaced, verified oil free wet exhaust operation.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 11 August 2022 Resolved
Replace missing gasket for E/R deck hatch to ensure space is watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 August 2022
Resolved 11 August 2022
Resolution: Receieved picture via email of new gasket installed on E/R hatch.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 June 2022 Resolved
The person in command of a documented vessel must have on board that vessel the original Certficate of Documentation currently in effect for that vessel. 46 CFR 67.313
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 July 2022
Resolved 26 June 2022
Resolution: Certification is onboard.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 June 2020 Resolved
A pre-engineered fixed gas fire extinguishing system must have a light to indicate discharge. Found discharge light to be inoperable.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 19 June 2020
Resolution: Deficiency rectified to the satisfaction of the attending marine inspector. Light indicator panel was replaced in kind.
05 - Radio Communications › N/A - No Subsystem › Distress messages: obligations and procedures
Issued 18 June 2020 Resolved
Placard must be posted next to all radio telephone installations with emergency broadcast instructions and information, specific to the vessel. Provide emergency broadcast placard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 July 2020
Resolved 19 June 2020
Resolution: Deficiency rectified to the satisfaction of the attending marine inspector. Emergency broadcast placard provided/posted.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 18 June 2020 Resolved
Vessel must carry adequate and up to date light list and coast pilot. Found 2017 LL & 2019 CP. Provide updated publications.
Action required: 10 - Deficiency Rectified
Due 18 June 2020
Resolved 18 June 2020
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 July 2019 Resolved
Hydrostatic release for EPIRB was expired.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 2 July 2019
Resolved 2 July 2019
Resolution: Vessel renewed Hydrostatic release for EPIRB.
Lifesaving › Inflatable Buoyant Apparatus › Stowage
Issued 30 May 2018 Resolved
Connect IBA painter correctly to hydrostatic release unit.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 30 May 2018
Resolved 30 May 2018
Resolution: Crew attached painter to HRU.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 25 April 2016 Resolved
Ladder and deckplates for engine room were missing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 25 April 2016
Resolution: Ladder and deckplates reinstalled.
Engineering › Bilge Water Management System › Hose
Issued 25 April 2016 Resolved
(05) hose clamps were missing on flexible hose connections for the bilge system in the engine room.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 25 April 2016
Resolved 25 April 2016
Resolution: Hose clamps installed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.