Behind this panel: 10 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 10
7 December 2020
Administrative Inspection
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 7107754
22 April 2019
Drydock Exam
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6684786
1 April 2019
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6653849
3 April 2018
Annual Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6388009
21 April 2017
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6130041
18 January 2017
Examination of Repairs
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6072998
6 January 2017
COI Inspection
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6064642
24 October 2016
DAPI Audit
Administrative · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 6033508
11 April 2016
Deficiency Check
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 5876494
7 April 2016
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5854231
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 1 April 2019
Resolved
Starboard emergency fuel shutoff valve inoperable.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2019
Resolved 2 April 2019
Resolution: replaced attachment from reach-rod
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 April 2019
Resolved
horn inoperable
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 2 April 2019
Resolved 2 April 2019
Resolution: replaced
Lifesaving › Lifefloat › Float-free Link
Issued 6 January 2017
Resolved
float free link missing tags port and starboard side.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 18 January 2017
Resolution: provided new tags for float free links
Engineering › Generator (propulsion/auxiliary-electric) › Winding
Issued 6 January 2017
Resolved
repair/replace windings
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 18 January 2017
Resolution: replaced and tested windings
Electrical › Electrical Distribution System (service) › Wiring
Issued 6 January 2017
Resolved
battery cables and conectors need replaced
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 23 January 2017
Resolved 18 January 2017
Resolution: replaced cables and connectors
Documentation › Logs/Records › Drug Test Records
Issued 24 October 2016
Resolved
Vessel/Company needs to show proof of Letter of Regulatory Compliance and DOT approved alcohol testing device.
Action required: 705 - Other - as specified
Due 15 November 2016
Resolved 29 November 2016
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 7 April 2016
Resolved
Missing double hose clamps on port engine wet exhaust hose.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 11 April 2016
Engineering › Fuel Oil Service System › Filter
Issued 7 April 2016
Resolved
Flame inpingement bowl missing on center engine fuel filter.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 11 April 2016
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 7 April 2016
Resolved
Sea rails not installed on cooking range.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 11 April 2016
Stability › Weathertight Integrity › General
Issued 7 April 2016
Resolved
2 cracked windows on vessels port side. Replace cracked windows. 46 CFR 176.25-50(a)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 11 April 2016
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 7 April 2016
Resolved
Ship name faded/illegible on all three ring buoys. Mark ships name on all ring buoys. 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 11 April 2016
Fire Fighting › Means of Escape › Doorways
Issued 7 April 2016
Resolved
Emergency exit in engine cannot be opened from inside engine room. Emergency exit in galley will not open/close properly. 46 CFR 176.25-50(a)
Condition: Improper/Lack of Maintenance
Due 21 April 2016
Resolved 11 April 2016
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 April 2016
Resolved
Hard wire potable water pump and battery charger. 46 CFR 111.60-5
Due 14 April 2016
Resolved 11 April 2016
Fire Fighting › Ventilation Systems › Ducts
Issued 7 April 2016
Resolved
Engine room ventilation ducts have excess oil/dirt build up. Clean ventilation ducts in engine room. 46 CFR 176.25-50(b)
Condition: Improper/Lack of Maintenance
Due 14 April 2016
Resolved 11 April 2016
Engineering › Bilge Water Management System › Valve
Issued 7 April 2016
Resolved
Screw down valve and reach rod in bilge line forward of collision bulkhead inoperable. Repair valve and reach rod. 46 CFR 182.25-5(d)
Action required: 705 - Other - as specified
Due 14 April 2016
Resolved 11 April 2016
Construction/Loadline › Hull › Weld
Issued 7 April 2016
Resolved
Found cracked welds in steering room and stbd engine mounts. Repair cracked welds.
Action required: 705 - Other - as specified
Due 21 April 2016
Resolved 11 April 2016
Accommodation/Occupational Safety › Potable Water System › General
Issued 7 April 2016
Resolved
Aft potable water tank is bulging and damaged with cracked supporting welds. Tank must remain empty until repaired to the satisfaction of attending CG marine inspector.
Action required: 705 - Other - as specified
Due 12 April 2016
Resolved 11 April 2016
Electrical › Electric Generation Source (service) › Generator
Issued 7 April 2016
Resolved
Excessive oil build up on generator windings. 46 CFR 176.25-50(b)
Condition: Improper/Lack of Maintenance
Due 14 April 2016
Resolved 11 April 2016