Records from 2016 to 2026. Most recent: inspection, 16 March 2026.
Documentation record
Registered dimensions (L × B × D)44.0 ft × 15.0 ft × 3.8 ft
Registered tonnagegross 16 / net 13
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderCARMAN BOATS INC · MARION, MD, UNITED STATES · built 1999
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeShip
Hull configurationMonohull
Hailing portSTONY CREEK, CT
Trade endorsementsCoastwise, unrestricted
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it16 - Simplified, Gross Ton
13 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Inspection history · 15
16 March 2026
Internal Structural Exam · Annual Inspection · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8412302
29 April 2025
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 8123958
2 May 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7895613
21 February 2024
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7866111
24 April 2023
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7664058
18 April 2022
Deficiency Check · COI Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7426619
13 December 2021
Internal Structural Exam · Hull Examination
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7367308
6 May 2021
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 7171734
17 June 2020
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6965324
30 March 2020
Hull Examination · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6934206
29 April 2019
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6672750
22 May 2018
Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6420552
5 March 2018
Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6366210
27 April 2017
COI Inspection · Deficiency Check
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6123028
3 May 2016
Deficiency Check · Annual Inspection
Physical examination · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 5867876
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 April 2025
Resolved
High level alarms for helm an engine space need an audible and visual alarm. Both not operating during the inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2025
Resolved 21 May 2025
Resolution: Alarms provides audible and visual alarm.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 29 April 2025
Resolved
The fwd most Life Float grab lines were not serviceable. Replace grab lines with new.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2025
Resolved 21 May 2025
Resolution: New lines are now on Life Float.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 May 2024
Resolved
Pre-engineered fire fighting systems need annual maintenance by a certified person. Engine room fire buoy doesn't have a current certification.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 3 May 2024
Resolution: Fire boy was serviced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 May 2024
Resolved
Remote fuel shutoff stations must be marked clearly legible letters at least 1" high indicating purpose of the valve and direction of operations. Markings is illegible due to foot traffic in the area.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 3 May 2024
Resolution: Fuel shutoffs clearly marked.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 2 May 2024
Resolved
Contained cooling system for the engine should have no leaks. Correct leak from coolant on the engine expansion tank.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 May 2024
Resolved 3 May 2024
Resolution: Vessel has corrected the leak.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 April 2022
Resolved
FCC Safety Radio certificate is expired. Renewal certificate. Route restricted to 1,000 ft from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2022
Resolved 25 April 2022
Resolution: Vsl has valiad FCC Safety.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 18 April 2022
Resolved
FCC Station license is expired. Renewal license. Route restricted to 1,000 ft from shore.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2022
Resolved 25 April 2022
Resolution: Valid FCC Station license.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 18 April 2022
Resolved
Float life for one of the Life Floats inop. Provide working float light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2022
Resolved 25 April 2022
Resolution: Vsl has operational float light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 18 April 2022
Resolved
Mast light not operational. Provide working mast light. Restrict route to day time operation only.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 May 2022
Resolved 25 April 2022
Resolution: Vsl has working mast light.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 June 2020
Resolved
Child life jackets topside not separated from adult. Separate and label child life jackets accordingly.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 18 June 2020
Resolution: Vessel rep has put a divide to distinguish child life jackets.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 17 June 2020
Resolved
Fixed pre-engineered system not inspected by certified persons. Have system certified accordingly.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 18 June 2020
Resolution: Certified company completed the annual maintenance on pre-engineered system.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for survival craft
Issued 17 June 2020
Resolved
Weak link for life floats not secured on a permanent fixture. Relocate weak link to permanent fixture.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 July 2020
Resolved 18 June 2020
Resolution: Weak link was relocated to a permanent fixture on the vessel.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 April 2019
Resolved
Portable extinguisher was missing from upper operating station
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 April 2019
Resolved 30 April 2019
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 29 April 2019
Resolved
High bilge water alarm in bar midship compartment was not operational
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 April 2019
Resolved 30 April 2019
Lifesaving › Lifefloat › Pendant
Issued 27 April 2017
Resolved
Replace painter, grab lineand pendants on life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2017
Resolved 5 May 2017
Resolution: Lines replaced.
Lifesaving › Lifefloat › Paddle
Issued 27 April 2017
Resolved
Replace life float paddles.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2017
Resolved 5 May 2017
Resolution: New paddles provided.
Engineering › Bilge Water Management System › Pump
Issued 27 April 2017
Resolved
Repair engine room bilge pump.
Action required: 701 - Prior to carriage of passengers/cargo
Due 5 May 2017
Resolved 5 May 2017
Resolution: Bilge pump repaired.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 3 May 2016
Resolved
Provide new asprin and eyewash for first-aid kit.
Due 3 June 2016
Resolved 3 May 2016
Resolution: New meds provided.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 3 May 2016
Resolved
Provide updated FCC safety radiotelephony certificate.
Due 3 June 2016
Resolved 3 June 2016
Resolution: Owner email certificate to MI.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 3 May 2016
Resolved
Provide pin and tamper seal for fireboy manual pull T-handle.
Due 3 June 2016
Resolved 3 May 2016
Resolution: New pin and tamper seal installed.