Passenger (Inspected) · Passenger Ship class · Built 1990s · USCG East District (CGD-E) · Other hulls named LADY THAMES
LADY THAMES is a 1999 passenger vessel (inspected). The Coast Guard has recorded 54 inspections since 1999, most recently in July 2026, along with 52 deficiencies, 1 operational control and 3 casualty investigations between 2015 and 2019.
Records from 1999 to 2026. Most recent: inspection, 13 July 2026.
- Built
- 1999
- Last inspected
- 13 July 2026
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 52 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 3 investigations · 2015–2019
Identity
1078662
WDQ6537
491937
Flag
UNITED STATES
367619930
Maury page id
psix-491937
Inspections, by type
…with no type recorded5
Years with a record
25 calendar years (1999–2026)
The 54 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)80.8 ft × 20.0 ft × 6.0 ft
Registered tonnagegross 76 / net 51
ITC dimensions (L × B × D)80.8 ft × 20.0 ft × 6.0 ft
ITC tonnagegross 169 / net 61
BuilderMID-CITY STEEL FABRICATION · LA CROSSE, WI, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portBALTIMORE, MD
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 17 June 2026 · expires 30 June 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it76 - Regulatory (Subpart C or D), Gross Ton
169 - Convention (Subpart B), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
61 - Convention (Subpart B), Net Ton
169 - Convention (Subpart B), Gross Ton
51 - Regulatory (Subpart C or D), Net Ton
61 - Convention (Subpart B), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ6537MMSI 367619930 · active · compulsorily equipped · granted 27 November 2025, expires 27 November 2035
WDH4654MMSI 367619930 · cancelled · compulsorily equipped · granted 14 February 2024, cancelled 25 November 2025
WDC6996MMSI 367064550 · expired · compulsorily equipped · granted 30 August 2005, cancelled 31 October 2015
WCZ8788MMSI not assigned · expired · compulsorily equipped · granted 14 June 2000, cancelled 14 August 2010
WCZ2391MMSI not assigned · expired · compulsorily equipped · granted 5 May 1999, cancelled 11 July 2009 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 54
13 July 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8437219
9 February 2026
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8309376
30 January 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8304014
9 September 2025
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8230449
9 January 2025
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8049371
19 September 2024
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7999189
20 November 2023
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7827621
16 November 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7807909
6 April 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7663979
9 March 2023
Load Line/Change of Employment
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7647575
26 January 2023
Drydock Exam · Examination of Repairs · Administrative Inspection · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7628178
23 January 2023
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7625726
18 January 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7352422
31 August 2021
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7302036
18 March 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7138292
14 December 2020
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7087175
19 December 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6885035
18 December 2019
Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6876615
24 April 2019
Examination of Repairs · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6669111
26 March 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6646933
5 November 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6565568
15 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6512796
13 April 2018
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6394002
22 January 2018
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6340308
25 September 2017
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6274355
19 August 2016
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5975409
12 July 2016
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5941906
9 July 2016
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5940197
9 July 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5947466
29 March 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5842529
17 December 2015
Excursion Permit
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5783632
16 October 2015
Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5747272
16 October 2015
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5790664
1 September 2015
COI Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5232524
9 May 2014
In-Service Inspection · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4854097
10 January 2011
Administrative Inspection
Administrative · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3924279
11 February 2010
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment St. Paul · USCG Heartland District (CGD-H) · Activity 3679081
15 August 2008
Administrative Inspection
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3299193
27 April 2007
COI Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2916986
7 August 2006
Annual Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2738501
18 May 2006
Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 2652247
9 November 2005
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2531583
7 June 2005
Periodic Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2379709
29 April 2004
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2113998
27 June 2003
Annual Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1831809
29 October 2002
Administrative Inspection
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1697957
3 May 2002
COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1611887
3 April 2001
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1059875
2 March 2001
Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1059081
18 May 2000
Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 818499
30 December 1999
Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1418638
8 November 1999
Administrative
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1444247
10 May 1999
Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1433486
1 April 1999
COI Inspection · Hull Examination · Initial Construction-Excluding Oversight
Physical examination · MSO ST LOUIS · USCG Heartland District (CGD-H) · Activity 1411848
Deficiency record · 52
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2026
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:
(1) Be buoyant;
(2) Be of at least 18.3 meters (60 feet) in length;
(3) Be non-kinking;
(4) Have a diameter of at least 7.9 millimeters (5/16 inch);
(5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and
(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Life ring's line was worn and brittle.
46CFR180.70(c)
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 February 2026
Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel had the wrong hailing port.
46CFR67.123
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 September 2025
Resolved
The Coast Guard was made aware that the vessel hit the bottom of the waterway while overtaking another vessel in the Saint Lucie Canal causing potential damage below the waterline.
Prior to movement, a damage survey must be completed by an attending CG Marine Inspector. Additionally, all repairs, if applicable, must be completed to the satisfaction of an attending CG Marine Inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 February 2024
Resolved
Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials, adequately protected from mechanical damage, and provided at the thank connections with devices that will automatically close in the event of rupture of the gauge or gauge lines.
Vessel's main diesel fuel tank is equipped with a tubular sight gauge that is constructed of plastic vinyl tubing with manual ball valves at the tank connections.
Remove current sight glass arrangement and cap valves or install proper tubular gauge glass arrangement to the satisfaction of the attending Marine Inspector prior to vessel movement.
46 CFR 182.440(a)(7)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2024
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy.
Vessel's ring life buoy equipped with a floating light located on the second deck has a lanyard of less than 3 feet in length.
46 CFR 180.70(d)(2)
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 April 2023
Resolved
07109 - Fixed CO2 System
The following spaces must be equipped with a fixed gas fire extinguishing system...a space containing propulsion machinery. During semi-annual maintenance and servicing, the third party inspection agency reported that the automatic discharge functions of the fixed carbon dioxide fire extinguishing system serving the engine compartment were inoperable.
In the interim, vessel may operate in accordance with owner's letter dated 25JAN23, requiring 01 additional crewmember in excess of what is required on the COI, who will be stationed in the engine compartment and follow the provided "STARSHIP III Engine Room Watch Duties" procedures. Operation is also contingent upon Coast Guard receipt of confirmation from the servicing company that the automatic discharge components of the CO2 system have been isolated and that the remote pull station for the system located at the entrance is operational.
Vessel rep must either repair the system to a fully operational status with an accompanying third party servicing tech report attesting as such, OR submit a proposal for replacement of the system for review/approval by the deficiency due date of 12MAY23.
46 CFR 181.400(a)(1)
50c
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 April 2023
Resolved
02103 - Stability
When necessary for safe operation, the cognizant OCMI may place specific stability restrictions in a stability letter or on the Certificate of Inspection of a vessel... Vessel installed new potable water tank in last drydock without approved drawings or calculations by MSC.
Vessel is reduced to 146 passengers until MSC has reviewed and approved calculations for stability changes.
46 CFR 178.210(c)
50c
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 29 March 2023
Resolved
Due to the removal of four plastic potable water tanks and installation of a single aluminum potable water tank, IAW the vessel's Stability Ltr H1-1502747 you must provide verification to the Marine Safety Center (MSC)that the vessel's lightship parameters have not changed, as presently outfitted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 January 2023
Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system...a space containing propulsion machinery.
During semi-annual maintenance and servicing, the third party inspection agency reported that the heat detection system and automatic discharge functions of the fixed carbon dioxide fire extinguishing system serving the engine compartment were inoperable.
Rectify within 7 days.
In the interim, vessel may operate in accordance with owner's letter dated 25JAN23, requiring 01 additional crewmember in excess of what is required on the COI, who will be stationed in the engine compartment and follow the provided "STARSHIP III Engine Room Watch Duties" procedures.
Operation is also contingent upon Coast Guard receipt of confirmation from the servicing company that the automatic discharge components of the CO2 system have been isolated and that the remote pull station for the system located at the entrance is operational.
46 CFR 181.400(a)(1)
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 January 2023
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located.
MI observed remote fuel shutoff for the main fuel tank did not fully close the center valve at the tank.
Rectify within 3 days.
46 CFR 182.455(b)(4)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2023
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
MI observed flexible hose installed on the supply side of the bow thruster engine raw water cooling system was bulging in multiple locations along its length.
Replace within 7 days.
46 CFR 182.100
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2023
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
MI observed pipe section just prior to the strainer for the generator cooling piping was showing signs of significant corrosion.
46 CFR 182.100
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 January 2023
Resolved
Cooking and heating equipment must be suitable for marine use.
MI observed vessel utilized portable open flame heaters for keeping food warm on the serving line.
46 CFR 184.200
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2023
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
MI observed ring life buoy on the second deck was missing lettering on the required marking.
Rectify within 7 days.
46 CFR 185.604(b)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 January 2023
Resolved
Stop valves and check valves are installed in the piping to isolate the systems during simultaneous operation and prevent possible flooding through the bilge system.
MI conducted operational test of bilge system with both the engine room and steering compartment not drawing a suction when bilge pump was energized. Identified both check valves in both compartments stuck closed not allowing suction.
Crew got both check valves loose, then showed proper operation.
46 CFR 182.520(i)(3)
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 January 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
MI observed missing quantity of aspirin.
Crew retrieved additional aspirin to meet compliance.
46 CFR 184.710
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2022
Resolved
Exhaust gas must not leak from the piping or any connections.
MI noted a salt buildup on stbd engine exhaust system.
46 CFR 182.430(b)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 January 2022
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
MI noted child and adult size life jackets stored in the same area without partition or separation.
46 CFR 180.78(a)(5)
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 January 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible, tide tables, and current tables.
MI noted vessel's charts were not updated and vessel did not have tide and current tables.
46 CFR 184.420(a)
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2022
Resolved
At least one ring life buoy must be fitted with a
lifeline. If more than one ring life buoy is carried,
at least one must not have a lifeline attached.
MI noted that all 3 life ring buoys had lifelines attached.
46 CFR 180.70(c)
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 January 2022
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
MI noted EPIRB was restricted from being float free by overhead on the 3rd deck aft of the operating station.
46 CFR 180.64
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 December 2020
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment...under all practicable conditions. Overboard dewatering pipe discovered on the forward port side of the engine room found corroded.
46 CFR 182.500 (a)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2020
Resolved
Cable and wire for power and lighting circuits must: be listed by Underwriters Laboratories (UL), as UL boat or UL Marine cable. Cable used for welding found leading from the battery space to the DC panel.
46 CFR 183.340(d)(2)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Loose uncapped wiring found behind the operating station and on the starboard side of the fly bridge.
46 CFR 183.200(c)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2020
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. Multiple power strips leading to permanent fixtures discovered in battery space.
46 CFR 183.340(r)
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 December 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Nautical charts found out-of-date since 2011.
46 CFR 184.420(a)(1)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 December 2020
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. A/C discharge hose on the starboard side of the sewage tank compartment found not capped or permanently enclosed.
46 CFR 182.100
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 December 2019
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in §176.500(b)(1) and your Certificate of Inspection must be endorsed.
Vessel exceeded 3 month time frame to complete annual inspection.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 December 2019
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. The OCMI may also decrease the drydock examination intervals to monitor the vessel's structural condition.
Vessel ran aground, suspected to have sustained hull and/or internal structural damage.
IAW: 46 CFR 176.600 (d)
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 November 2018
Resolved
A device must be provided to automatically shut down power ventilation servicing the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space.
Starboard engine room ventilation shut down flap is inoperable. Repair or replace. - 46CFR181.410(b)(10)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2018
Resolved
Batteries must be mounted in trays.
Battery mount for #2 generator is loose. Repair. - 46CFR183.350(e)
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length, no dimension information (AIS Antenna Position ABCD values equals 0), and not broadcasting an AIS Ship Type.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 October 2017
Resolved
Renumber life jacket containers for appropriate numbers iaw 46CFR185.604(f).
Communications › Radio Communications › VHF Radiotelephone
Issued 4 October 2017
Resolved
Install GPS on VHF-FM radio iaw 46CFR184.502.
Engineering › Bilge Water Management System › Strainer
Issued 26 September 2016
Resolved
Provide a bilge suction strainer no less than three times the area of the bilge pipe in the tank room IAW 46 CFR 182.510(b).
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 9 July 2016
Resolved
The port main engine was not in compliance with 46 CFR 182.420 (a). The cooling pump was inoperable.
Engineering › Shafting/Propeller Arrangements › Thrust Shaft
Issued 16 October 2015
Resolved
Find cause of port engine mount and shaft extension fracture. Make proper repairs to the satisfaction of the attending marine inspector. Submit repair proposal on all work prior to conducting IAW 46CFR182.200
Fire Fighting › Remote Fuel Shutoff › General
Issued 8 September 2015
Resolved
Emergency fuel shut-off valve is inoperable. 46CFR182.720(c)(3)(ii)
Communications › Radio Communications › EPIRB
Issued 8 September 2015
Resolved
Hydrostatic release for EPIRB has expired. 46CFR185.740. Vessel is restriced from passing the COLREGS line
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 8 September 2015
Resolved
Vessel must provide proof od Drug and Alcohol testing program.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 September 2015
Resolved
Vessel must have all required contents in first aid kit. 46CFR184.710
Operations/Management › Drills/Instruction › Flooding Mitigation
Issued 8 September 2015
Resolved
Vessel emergency instructions to include must be posted. 46CFR185.110
Navigation › Piloting/Steering › Coast Guard Light List
Issued 8 September 2015
Resolved
Vessel must provide updated light list and NTM for current chart or procure an updated chart. 46CFR184.402
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 September 2015
Resolved
Vessel must post current COI, COD, and stability letter in passenger view. 46CFR 176.302
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 September 2015
Resolved
Plastic zip-ties must be removed and replaced with metalic when holding up wire in engine space. 46CFR 183.310
Engineering › Fuel Oil Service System › Hose
Issued 8 September 2015
Resolved
Aft generator flex hose line to fuel filter must be shortened to not more than 30in. 46CFR 182.720 (e)(3)(v)
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 September 2015
Resolved
Metalic vales must be fitted to PVC pipe where it penatrates the water-tight bulkhead between the soda room and tank room. 46CFR182.720(d)
Lifesaving
Issued 8 November 1999
Resolved
PROPERLY ATTACH WEAK LINK TO DECK AND PAINTER ON LIFEFLOATS.
Lifesaving
Issued 8 November 1999
Resolved
PROVIDE RESCUE BOAT OR AN APPROVED ALTERNATIVE PROCEDURE ACCEPTABLE TO COGNIZANT OCMI.
Documentation
Issued 1 April 1999
Resolved
Provide proof of Documentation _x001C_ To be completed prior to carrying passengers.
Fire Fighting
Issued 1 April 1999
Resolved
Provide crew to conduct Manoverboard and Fire Drills for the attending Coast Guard Marine Inspector upon arrival in Naples, FL and Prior to carrying passengers.
Documentation
Issued 1 April 1999
Resolved
Provide proof of Drug testing Program for crew. _x001C_ To be completed prior to carrying passengers.
Casualty record · 3
16 October 2015Routine · role: Involved in a Marine Casualty · activity 5790664
9 July 2016Routine · role: Involved in a Marine Casualty · activity 5947466
19 December 2019Routine · role: Involved in a Marine Casualty · activity 6885035
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Recorded names · 2
SENSATION (2015–2016), STARSHIP III (2019). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.