Inspection history · 30
13 July 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8437219
9 February 2026
COI Inspection
Physical examination · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8309376
30 January 2026
Administrative Inspection
Administrative · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 8304014
9 September 2025
Damage Survey · Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Lake Worth · USCG Southeast District (CGD-SE) · Activity 8230449
9 January 2025
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 8049371
19 September 2024
COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7999189
20 November 2023
Deficiency Check · Damage Survey · Administrative Inspection
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7827621
16 November 2023
Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7807909
6 April 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7663979
9 March 2023
Load Line/Change of Employment
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7647575
26 January 2023
Drydock Exam · Examination of Repairs · Administrative Inspection · Construction Oversight
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 7628178
23 January 2023
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7625726
18 January 2022
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7352422
31 August 2021
In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7302036
18 March 2021
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7138292
14 December 2020
Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 7087175
19 December 2019
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6885035
18 December 2019
Administrative Inspection · COI Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6876615
24 April 2019
Examination of Repairs · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6669111
26 March 2019
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6646933
5 November 2018
Deficiency Check · Annual Inspection · DAPI Audit
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6565568
15 August 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6512796
13 April 2018
Administrative Inspection
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6394002
22 January 2018
Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6340308
25 September 2017
DAPI Audit · Deficiency Check · Annual Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6274355
19 August 2016
Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5975409
12 July 2016
Administrative Inspection · Internal Structural Exam · Examination of Repairs · Hull Examination · In-Service Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5941906
9 July 2016
Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5940197
9 July 2016
Type not recorded
No type recorded · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5947466
29 March 2016
Hull Examination · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5842529
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2026
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must:
(1) Be buoyant;
(2) Be of at least 18.3 meters (60 feet) in length;
(3) Be non-kinking;
(4) Have a diameter of at least 7.9 millimeters (5/16 inch);
(5) Have a breaking strength of at least 5 kilonewtons (1,124 pounds); and
(6) Be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Life ring's line was worn and brittle.
46CFR180.70(c)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 February 2026
Resolution: New life rings and equipment have been updated.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 February 2026
Resolved
The hailing port of the vessel must be marked on some clearly visible exterior part of the stern of the vessel. Vessel had the wrong hailing port.
46CFR67.123
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2026
Resolved 11 February 2026
Resolution: Vessel has updated the Hailing Port on the stern.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 9 September 2025
Resolved
The Coast Guard was made aware that the vessel hit the bottom of the waterway while overtaking another vessel in the Saint Lucie Canal causing potential damage below the waterline.
Prior to movement, a damage survey must be completed by an attending CG Marine Inspector. Additionally, all repairs, if applicable, must be completed to the satisfaction of an attending CG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 23 October 2025
Resolution: All repairs made. Sea trials conducted. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 1 February 2024
Resolved
Tubular gauge glasses, if fitted to diesel fuel tanks, must be of heat resistant materials, adequately protected from mechanical damage, and provided at the thank connections with devices that will automatically close in the event of rupture of the gauge or gauge lines.
Vessel's main diesel fuel tank is equipped with a tubular sight gauge that is constructed of plastic vinyl tubing with manual ball valves at the tank connections.
Remove current sight glass arrangement and cap valves or install proper tubular gauge glass arrangement to the satisfaction of the attending Marine Inspector prior to vessel movement.
46 CFR 182.440(a)(7)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 March 2024
Resolved 1 February 2024
Resolution: Sightglass removed and valves plugged off.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 1 February 2024
Resolved
Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy.
Vessel's ring life buoy equipped with a floating light located on the second deck has a lanyard of less than 3 feet in length.
46 CFR 180.70(d)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2024
Resolved 1 February 2024
Resolution: Vessel rep provided picture of new six foot lanyard attached to life buoy.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 12 April 2023
Resolved
07109 - Fixed CO2 System
The following spaces must be equipped with a fixed gas fire extinguishing system...a space containing propulsion machinery. During semi-annual maintenance and servicing, the third party inspection agency reported that the automatic discharge functions of the fixed carbon dioxide fire extinguishing system serving the engine compartment were inoperable.
In the interim, vessel may operate in accordance with owner's letter dated 25JAN23, requiring 01 additional crewmember in excess of what is required on the COI, who will be stationed in the engine compartment and follow the provided "STARSHIP III Engine Room Watch Duties" procedures. Operation is also contingent upon Coast Guard receipt of confirmation from the servicing company that the automatic discharge components of the CO2 system have been isolated and that the remote pull station for the system located at the entrance is operational.
Vessel rep must either repair the system to a fully operational status with an accompanying third party servicing tech report attesting as such, OR submit a proposal for replacement of the system for review/approval by the deficiency due date of 12MAY23.
46 CFR 181.400(a)(1)
50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 12 May 2023
Resolved 17 April 2023
Resolution: Received third party servicing report stating the system was fully operational
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 6 April 2023
Resolved
02103 - Stability
When necessary for safe operation, the cognizant OCMI may place specific stability restrictions in a stability letter or on the Certificate of Inspection of a vessel... Vessel installed new potable water tank in last drydock without approved drawings or calculations by MSC.
Vessel is reduced to 146 passengers until MSC has reviewed and approved calculations for stability changes.
46 CFR 178.210(c)
50c
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2023
Resolved 17 April 2023
Resolution: Received letter from MSC regarding lightship weight changes.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 29 March 2023
Resolved
Due to the removal of four plastic potable water tanks and installation of a single aluminum potable water tank, IAW the vessel's Stability Ltr H1-1502747 you must provide verification to the Marine Safety Center (MSC)that the vessel's lightship parameters have not changed, as presently outfitted.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 April 2023
Resolved 6 April 2023
Resolution: Naval Architect has provided MSC with stability calculations with the added new tank and added weight. CG SSP has issued a CG-835 def. reducing pax by four with the added weight of the P/W tank until MSC provides approval letter for this change.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 26 January 2023
Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system...a space containing propulsion machinery.
During semi-annual maintenance and servicing, the third party inspection agency reported that the heat detection system and automatic discharge functions of the fixed carbon dioxide fire extinguishing system serving the engine compartment were inoperable.
Rectify within 7 days.
In the interim, vessel may operate in accordance with owner's letter dated 25JAN23, requiring 01 additional crewmember in excess of what is required on the COI, who will be stationed in the engine compartment and follow the provided "STARSHIP III Engine Room Watch Duties" procedures.
Operation is also contingent upon Coast Guard receipt of confirmation from the servicing company that the automatic discharge components of the CO2 system have been isolated and that the remote pull station for the system located at the entrance is operational.
46 CFR 181.400(a)(1)
Action required: 705 - Other - as specified
Due 3 February 2023
Resolved 12 April 2023
Resolution: Updated deficiency and issued new deficiency for 30 days. Refer to MISLE Activity #7663979.
07 - Fire Safety › N/A - No Subsystem › Remote Means of control (opening,pumps,ventilation,etc.) Machinery spaces
Issued 23 January 2023
Resolved
The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located.
MI observed remote fuel shutoff for the main fuel tank did not fully close the center valve at the tank.
Rectify within 3 days.
46 CFR 182.455(b)(4)
Action required: 705 - Other - as specified
Due 26 January 2023
Resolved 26 January 2023
Resolution: Vessel rep sent pictures of proper alignment of valves.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2023
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
MI observed flexible hose installed on the supply side of the bow thruster engine raw water cooling system was bulging in multiple locations along its length.
Replace within 7 days.
46 CFR 182.100
Action required: 705 - Other - as specified
Due 30 January 2023
Resolved 27 January 2023
Resolution: Replaced hose.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 23 January 2023
Resolved
All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury.
MI observed pipe section just prior to the strainer for the generator cooling piping was showing signs of significant corrosion.
46 CFR 182.100
Action required: 16 - Rectify deficiencies w/in 14 days
Due 6 February 2023
Resolved 27 January 2023
Resolution: Replaced corroded section of piping.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 23 January 2023
Resolved
Cooking and heating equipment must be suitable for marine use.
MI observed vessel utilized portable open flame heaters for keeping food warm on the serving line.
46 CFR 184.200
Action required: 10 - Deficiency Rectified
Due 23 January 2023
Resolved 23 January 2023
Resolution: Removed open flame cannisters from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 23 January 2023
Resolved
Each ring life buoy must be marked in clearly legible block capital letters with the vessel's name.
MI observed ring life buoy on the second deck was missing lettering on the required marking.
Rectify within 7 days.
46 CFR 185.604(b)
Action required: 705 - Other - as specified
Due 30 January 2023
Resolved 6 February 2023
Resolution: Re-stenciled labeling on ring life buoys.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 23 January 2023
Resolved
Stop valves and check valves are installed in the piping to isolate the systems during simultaneous operation and prevent possible flooding through the bilge system.
MI conducted operational test of bilge system with both the engine room and steering compartment not drawing a suction when bilge pump was energized. Identified both check valves in both compartments stuck closed not allowing suction.
Crew got both check valves loose, then showed proper operation.
46 CFR 182.520(i)(3)
Action required: 10 - Deficiency Rectified
Due 23 January 2023
Resolved 23 January 2023
Resolution: Crew was able to get the check valves to function while CG was onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 23 January 2023
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions.
MI observed missing quantity of aspirin.
Crew retrieved additional aspirin to meet compliance.
46 CFR 184.710
Action required: 10 - Deficiency Rectified
Due 23 January 2023
Resolved 23 January 2023
Resolution: Crew provided suitable quantities of aspirin.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 January 2022
Resolved
Exhaust gas must not leak from the piping or any connections.
MI noted a salt buildup on stbd engine exhaust system.
46 CFR 182.430(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 24 January 2022
Resolution: Vessel representative patched hole on exhaust using FRP. No leak detected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 January 2022
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets.
MI noted child and adult size life jackets stored in the same area without partition or separation.
46 CFR 180.78(a)(5)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 18 January 2022
Resolution: Vessel representative added partition between adult and child size life jackets.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 January 2022
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible, tide tables, and current tables.
MI noted vessel's charts were not updated and vessel did not have tide and current tables.
46 CFR 184.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2022
Resolved 18 January 2022
Resolution: Vessel updated charts and obtained tide and current tables.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 January 2022
Resolved
At least one ring life buoy must be fitted with a
lifeline. If more than one ring life buoy is carried,
at least one must not have a lifeline attached.
MI noted that all 3 life ring buoys had lifelines attached.
46 CFR 180.70(c)
Action required: 10 - Deficiency Rectified
Due 18 January 2022
Resolved 18 January 2022
Resolution: Vessel representative removed lifeline from one life ring.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 18 January 2022
Resolved
Each vessel that operates on the high seas, or that operates beyond three miles from the coastline of the Great Lakes, must have on board a FCC Type Accepted Category 1, 406 MHz EPIRB, installed to automatically float free and activate.
MI noted EPIRB was restricted from being float free by overhead on the 3rd deck aft of the operating station.
46 CFR 180.64
Action required: 10 - Deficiency Rectified
Due 18 January 2022
Resolved 18 January 2022
Resolution: Vessel representative moved EPIRB to a float free location.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 December 2020
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment...under all practicable conditions. Overboard dewatering pipe discovered on the forward port side of the engine room found corroded.
46 CFR 182.500 (a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2020
Resolved 25 December 2020
Resolution: Vessel rep provided pictures via e-mail rectifying deficiency. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2020
Resolved
Cable and wire for power and lighting circuits must: be listed by Underwriters Laboratories (UL), as UL boat or UL Marine cable. Cable used for welding found leading from the battery space to the DC panel.
46 CFR 183.340(d)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2020
Resolved 25 December 2020
Resolution: Vessel rep provided pictures via e-mail rectifying deficiency. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2020
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Loose uncapped wiring found behind the operating station and on the starboard side of the fly bridge.
46 CFR 183.200(c)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2020
Resolved 27 December 2020
Resolution: Vessel rep provided pictures via e-mail rectifying deficiency. Deficiency cleared.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 14 December 2020
Resolved
A portable or temporary electric cord or cable must be constructed and used in compliance with the requirements of 111.60-13 in subchapter J of this chapter for a flexible electric cord or cable. Multiple power strips leading to permanent fixtures discovered in battery space.
46 CFR 183.340(r)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2020
Resolved 25 December 2020
Resolution: Vessel rep provided pictures via e-mail rectifying deficiency. Deficiency cleared.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 14 December 2020
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Nautical charts found out-of-date since 2011.
46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2020
Resolved 25 December 2020
Resolution: Vessel rep provided pictures via e-mail rectifying deficiency. Deficiency cleared.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 14 December 2020
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. A/C discharge hose on the starboard side of the sewage tank compartment found not capped or permanently enclosed.
46 CFR 182.100
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 December 2020
Resolved 25 December 2020
Resolution: Vessel rep provided pictures via e-mail rectifying deficiency. Deficiency cleared.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 19 December 2019
Resolved
To maintain a valid Certificate of Inspection, you must complete your annual inspection within the periods specified in §176.500(b)(1) and your Certificate of Inspection must be endorsed.
Vessel exceeded 3 month time frame to complete annual inspection.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2019
Resolution: Conducted full COI and issued new COI.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 December 2019
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. The OCMI may also decrease the drydock examination intervals to monitor the vessel's structural condition.
Vessel ran aground, suspected to have sustained hull and/or internal structural damage.
IAW: 46 CFR 176.600 (d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 December 2019
Resolution: No visible damage could be found. All sat.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 5 November 2018
Resolved
A device must be provided to automatically shut down power ventilation servicing the protected space and engines that draw intake air from the protected space prior to release of the extinguishing agent into the space.
Starboard engine room ventilation shut down flap is inoperable. Repair or replace. - 46CFR181.410(b)(10)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 November 2018
Resolution: Rectified on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 5 November 2018
Resolved
Batteries must be mounted in trays.
Battery mount for #2 generator is loose. Repair. - 46CFR183.350(e)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 November 2018
Resolved 27 November 2018
Resolution: Vessel representative mounted tray permanently.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 15 August 2018
Resolved
Vsl is broadcasting: Greater/smaller than expected vessel length, no dimension information (AIS Antenna Position ABCD values equals 0), and not broadcasting an AIS Ship Type.
Condition: Invalid
Action required: 705 - Other - as specified
Due 15 September 2018
Resolved 30 September 2019
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 4 October 2017
Resolved
Renumber life jacket containers for appropriate numbers iaw 46CFR185.604(f).
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 18 October 2017
Resolution: Life jacket storage containers renumbered to relfect appropriate number of lifejackets inside.
Communications › Radio Communications › VHF Radiotelephone
Issued 4 October 2017
Resolved
Install GPS on VHF-FM radio iaw 46CFR184.502.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 October 2017
Resolved 18 October 2017
Resolution: GPD properly displayed on VHF-FM radio.
Engineering › Bilge Water Management System › Strainer
Issued 26 September 2016
Resolved
Provide a bilge suction strainer no less than three times the area of the bilge pipe in the tank room IAW 46 CFR 182.510(b).
Action required: 705 - Other - as specified
Due 3 October 2016
Resolved 3 October 2016
Engineering › Freshwater System (jacketwater cooling) › Pump
Issued 9 July 2016
Resolved
The port main engine was not in compliance with 46 CFR 182.420 (a). The cooling pump was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 July 2016
Resolution: Tech from CAT attended the vsl - found the pump was loose causing the v-grooved belt to fall off pulley. Tightened pump, replaced pulley and belt.