05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 25 November 2024
Resolved
Observed functional test of EPIRP, test was UNSAT. Vessel is to replace EPIRP and will be limited to operated within 3 less than 3 nautical miles from shore.
46CFR180.64
Action required: 705 - Other - as specified
Resolved 5 April 2025
Resolution: POC provided copy of new registration and video of a function test. All SAT
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 25 November 2024
Resolved
essel does not have a smoke/fire detection system in the engine. Vessel is to install an smoke detection system that will be integrated with all existing smoke detectors. Vessel will be limited to Lakes, bay, and sounds until replacement and CG Marine Inspector witness proper testing.
46CFR177.410
Action required: 705 - Other - as specified
Resolved 16 April 2025
Resolution: Marine Inspector witnessed proper operation of newly added interconnected engine room smoke detector, activating the interconnected existing portions of the fire detection and Smart Skipper system.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 November 2024
Resolved
Vessel does not have a watchmen monitoring device in the engine room. Vessel shall not carry overnight passengers and operate on a Coast-wise or Ocean route, until monitoring device is installed forward of the engine room and a witness test by a CG Marine Inspector witness.
46CFR185.410
Action required: 705 - Other - as specified
Resolved 16 April 2025
Resolution: Witnessed watch alerter call point installed in forward engine room operate with vessel Smart Skipper roving watch system.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 16 April 2024
Resolved
Observed all three life floats were not properly stored. Vessel is to store life floats IAW 46CFR180.137, prior to taking on passengers.
Action required: 705 - Other - as specified
Resolved 22 April 2024
Resolution: Def rectified during hull exam MISLE 7883079
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 February 2024
Resolved
An owner or managing operator shall make a vessel available for drydock and internal structure examinations at least once every two years. During repower, vessel has past its 31 DEC 2023 drydock date.
Condition: Placed in Improper Service
Action required: 17 - Rectify deficiencies prior to departure
Due 1 February 2024
Resolved 22 April 2024
Resolution: Vessel received drydock credit.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 6 March 2023
Resolved
A vessel must be provided with bilge pumps in accordance with Table 182.520(a). MI found vessel bilge pump motor un-wired.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2023
Resolved 21 April 2023
Resolution: Attended vessel, All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2023
Resolved
The shutoff valve at the tank shall be operable from outside the tank compartment, preferably from an
accessible position on the weather deck. MI found diesel
day tank in engine room with out an accessible shutoff
valve.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2023
Resolved 21 April 2023
Resolution: Attended vessel, All sat.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 March 2023
Resolved
A suitable marine type strainer shall be fitted in the fuel supply line in the engine compartment. MI found both Generators in the E/R without a marine type fuel strainer. Vessel can install metal flame shield and metal petcock on bottom to fulfill this requirement.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 7 March 2023
Resolved 21 April 2023
Resolution: Attended vessel, All sat.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 6 March 2023
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10. Vessel could not provide portable fire-fighting certificate.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 March 2023
Resolved 21 April 2023
Resolution: Attended vessel, All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 6 March 2023
Resolved
A vessel may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. MI found 02 R/W suction valves in the engine room open with no attached piping or blank flanged.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 21 April 2023
Resolution: Attended vessel, All sat.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 6 March 2023
Resolved
Each vessel must meet the applicable requirements in Sub chapter S of this chapter. MI found fwd/port bulkhead in the lazarette not water tight.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 21 April 2023
Resolution: Attended vessel, All sat.
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 6 March 2023
Resolved
At each inspection for certification and at every other vessel inspections all observed unsafe practices, fire hazards, and other hazardous situations must be corrected. MI found excessive gear adrift about the vessel and ongoing carpentry projects.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 21 April 2023
Resolution: Attended vessel, All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 March 2023
Resolved
Life floats shall be stowed that when the vessel sinks the survival craft floats fee. Vessel shall provide evidence that life floats are in a float free-arrangement.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 April 2023
Resolved 21 April 2023
Resolution: Attended vessel, All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 6 March 2023
Resolved
When life floats are stowed in tiers, the separate units must be kept apart by spacers. MI found no spacer between life floats.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 March 2023
Resolved 21 April 2023
Resolution: Attended vessel, All sat.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2021
Resolved
Electrical wire in lazarette space found to have unprotected dead end. Cap or remove bare wire.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 7 February 2022
Resolution: Terminated dead end of wire.
06 - Cargo Operations Including Equipment › N/A - No Subsystem › Other (cargo)
Issued 13 December 2021
Resolved
Bait tank pump found to be leaking and not mounted. Repair leak, and securely mount to prevent movement.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 7 February 2022
Resolution: POC provided proof of pump being securely mounted and leak free.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 13 December 2021
Resolved
Certificate of Documentation found to be expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 13 January 2022
Resolution: Provided proof of documentation
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 December 2021
Resolved
EPIRB registration found to be expired. Vessel restricted to <3NM until registered.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 15 December 2021
Resolution: Provided Coast Guard with updated EPIRB registration
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 13 December 2021
Resolved
Vessel not equip with second bilge pump arrangement as
required for routes and conditions: Oceans zone 2.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 21 January 2022
Resolved 10 January 2022
Resolution: POC provided proof of installing a second bilge pump.
05 - Radio Communications › N/A - No Subsystem › Functional requirements
Issued 13 December 2021
Resolved
Single side band radio not able to receive transmission
during operational tests. Repair or replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 January 2022
Resolved 20 January 2022
Resolution: Sent invoice for SSB maintenance.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 7 October 2021
Resolved
Each life- float must be stowed so that when the vessel sinks the survival craft floats free and, if inflatable inflates automatically. Life floats observed to have rigid cover restricting their ability to float free. Restrict persons allowed to 25 until resolved.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 8 October 2021
Resolved 23 November 2021
Resolution: Restricted within the deficiency.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of Lifeboats
Issued 7 October 2021
Resolved
Each liferaft or group of liferafts must be arranged for float free launching. Life raft painter line found to be incorrectly installed.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 23 November 2021
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 18 December 2020
Resolved
Repair/replace wasted/leaking fuel supply piping in forward engine room.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 December 2020
Resolution: Received photos of replaced piping.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 18 December 2020
Resolved
Provide 03 UL 217 approved smoke detectors within overnight accommodation spaces. No overnight passengers until corrected.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 December 2020
Resolution: Received photos of new smoke detectors installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 December 2020
Resolved
Prove proper operation of bilge pump system.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 18 December 2020
Resolution: Received video of bilge system operating and taking suction from forward compartment.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 18 December 2020
Resolved
Remove/replace recreational diesel fuel filter from stbd generator.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2021
Resolved 18 December 2020
Resolution: Received photos of removed filter from generator.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 18 December 2020
Resolved
Remove or terminate to J-box, 02 dead-end cables in stbd steering compartment.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 January 2021
Resolved 18 December 2020
Resolution: Received photos of cables removed from lazarette.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 9 December 2019
Resolved
Provide vessel with valid FCC station license certificate.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 December 2019
Resolution: Vessel was provided with valid certificate.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 9 December 2019
Resolved
Provide DSC VHF radio with GPS input for emergency location signaling.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 December 2019
Resolution: VHF DSC radio was provided with GPS input.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 9 December 2019
Resolved
Prove operation of installed bilge piping system.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 19 December 2019
Resolution: Vessel rep proved operation of installed bilge system.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 December 2019
Resolved
Renew life ring light line with 3-6' length.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 19 December 2019
Resolution: Life ring was provided with new line.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file or current installations do not match what we have on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps. Due 02Jan2020.
Action required: 705 - Other - as specified
Due 2 January 2020
Resolved 19 May 2020
Resolution: Vessel rep submitted one-line drawing of onboard electrical panels.
10 - Safety of Navigation › N/A - No Subsystem › Other (navigation)
Issued 2 October 2019
Resolved
While underway or drifting at sea, every vessel shall at all times maintain a proper look-out by sight and hearing. The designated watchmen required by 46 CFR 185.410 cannot preform both roving patrolling and look-out watch simultaneously. Vessel has been instructed to operate with a look-out and watchman while conducting drift operations.
Action required: 10 - Deficiency Rectified
Due 2 October 2019
Resolved 2 October 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
All electrical equipment must be clearly labeled marked and identified. Label all breakers on all panels for what circuit they feed.
Action required: 705 - Other - as specified
Due 4 November 2019
Resolved 4 November 2019
Resolution: Received photo of breaker panel labeling.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Provide chafe protection (stuffing tube / squeeze fittings) for all cable penetrations on all electrical panels.
Action required: 705 - Other - as specified
Due 4 November 2019
Resolved 4 November 2019
Resolution: Received photo of squeeze fitting installed on main breaker panel.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Remove Romex (solid copper) cable from wheel house 12volt panel and replace with proper sized boat cable.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 4 November 2019
Resolution: Recieved photo of removed romex cable.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019
Resolved
Provide both aft accommodation doors with labeling on both sides in clearly legible 2" letters that reads "EMERGENCY EXIT, KEEP CLEAR".
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 4 November 2019
Resolution: Received photo of installed sign.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 2 October 2019
Resolved
Provide additional emergency lighting in forward area of accommodation space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 4 November 2019
Resolution: Received photo of installed emergency light fixture.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Remove permanently installed extension cord in wheel house.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 November 2019
Resolved 4 November 2019
Resolution: Received photo of removed extension cord.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 2 October 2019
Resolved
Replace burnt conductors found in engine room electrical distribution panel for bunk room A/C circuit.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 2 October 2019
Resolution: Vessel rep provided photos of conductors cut back to good conductors and re-attached.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 13 June 2019
Resolved
Replace EPIRB battery, renew EPIRB registration, replace EPIRB hydrostatic release.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 June 2019
Resolution: EPIRB battery was replaced, device was registered, and new hydrostatic release was provided.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 13 June 2019
Resolved
Properly install life floats to ensure float free arrangement and ensure that each life float is attached to the vessel via an approved weak link.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 June 2019
Resolution: Life floats were installed properly and new weak link installed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2019
Resolved
Properly secure dead-end wires (upper deck-freezer location, state room).
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 June 2019
Resolution: Wires were pulled back and removed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 June 2019
Resolved
Replace welding cables throughout vessel with approved battery cables.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 June 2019
Resolution: Welding cables were replaced with boat cable.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 13 June 2019
Resolved
Replaced unsuitable/worn fuel hoses in the machinery space, as identified, with hoses and fittings approve in accordance with SAE J-1942. Ensure that all fuel hoses are properly supported. Install plugs on fuel filter drains.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 June 2019
Resolution: Fuel hoses were replaced with SAE J-1942, supported, and plugs were installed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 13 June 2019
Resolved
Remove shafts for inspection of shaft tubes - crop and renew wasted shaft tubes as identified.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 June 2019
Resolution: Shafts were removed and inspected. Port shaft tube was cropped and renewed.
04 - Emergency Systems › N/A - No Subsystem › Water level indicator
Issued 13 June 2019
Resolved
Prove proper operation of bunk space high water alarm.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 June 2019
Resolution: High water alarm was repaired and proved operational.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 13 June 2019
Resolved
Make machinery space bulkhead penetrations watertight.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 18 June 2019
Resolution: Bulkhead penetrations were sealed and made watertight.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 13 June 2019
Resolved
Conduct underway emergency drills (Fire/Abandon Ship/MOB).
Action required: 705 - Other - as specified
Resolved 25 June 2019
Resolution: Sea trial and underway drill were completed.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 14 September 2018
Resolved
NAME: Vsl is broadcasting incorrect Name, ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 4 February 2019
Resolution: Verified in VIVS.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 June 2018
Resolved
Replace damaged ring buoy.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2018
Resolved 25 June 2018
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 20 June 2018
Resolved
Replace corroded life raft strap clip.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2018
Resolved 25 June 2018
09 - Working and Living Conditions › 091 - Living Conditions › Galley, handlingroom (maintenance)
Issued 20 June 2018
Resolved
Provide an acceptable means to prevent grease from accumulating on electrical wiring in the galley hood.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 July 2018
Resolved 25 June 2018
Stability › Watertight Integrity › Weathertight Enclosure
Issued 8 June 2017
Resolved
Make forward hatch watertight
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 19 September 2017
Resolution: Corrected
Engineering › Steering Gear System › Hydraulic Hose
Issued 8 June 2017
Resolved
Repair hydraulic leak under pilothouse console helm.
Action required: 705 - Other - as specified
Due 21 June 2017
Resolved 19 September 2017
Resolution: Corrected