Inspection history · 22
17 April 2025
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 8102606
7 May 2024
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7904225
26 April 2024
Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7899738
24 April 2023
Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7675628
12 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608085
26 April 2022
Deficiency Check
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7585627
25 April 2022
Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7438794
7 February 2022
COI Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 7392086
26 January 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7386044
28 February 2021
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7147669
2 April 2020
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6939572
18 February 2020
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6910493
8 March 2019
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6638661
28 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6550507
14 May 2018
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6413931
9 April 2018
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6388472
2 April 2018
Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6383346
4 January 2018
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6332525
29 March 2017
Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6114044
14 February 2017
DAPI Audit · Deficiency Check · Administrative Inspection · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6087308
20 October 2016
Simplified Stability Test · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6028429
17 March 2016
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5846250
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 17 April 2025
Resolved
A hatch exposed to the weather must be watertight. Marine Inspector observed lazarette hatch with failed gasket. Vessel to install gasket to satisfaction of Marine Inspector.
46 CFR 179.360(a)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 29 April 2025
Resolution: Operator submitted photos to Marine Inspector showing satisfactory replacement.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 17 April 2025
Resolved
Flexible nonmetallic hose may be used in non-vital water and pneumatic systems. Marine Inspector observed corroded hose end on saltwater system for toilet. Vessel to replace hose to satisfaction of Marine Inspector.
46 CFR 182.720(e)(2)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 29 April 2025
Resolution: Operator submitted photos to Marine Inspector showing satisfactory replacement.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 April 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Marine Inspector observed 120-volt outlet in engine room mounted by zip-tie. Vessel to properly mount outlet box and install cover to satisfaction of Marine Inspector.
46 CFR 183.200(b)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2025
Resolved 29 April 2025
Resolution: Operator submitted photos to Marine Inspector showing satisfactory repair.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 17 April 2025
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Marine Inspector observed metal support brackets in engine room with excessive corrosion. Vessel to replace to satisfaction of Marine Inspector prior to next credit dry-dock.
46 CFR 177.100
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 March 2026
Resolution: Vessel replaced corroded support brackets.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 17 April 2025
Resolved
On a nonmetallic vessel, the enclosures and frames of electrical equipment must be bonded together to a common ground by a normally non-current carrying conductor. Marine Inspector observed grounding straps in center hold with excessive corrosion. Vessel to replace to satisfaction of Marine Inspector prior to next credit dry-dock.
46 CFR 183.372(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 March 2026
Resolution: Vessel replaced corroded grounding straps.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 May 2024
Resolved
Each survival craft required on a vessel by this part must meet one of the following: For an inflatable buoyant apparatus—Approved under approval series 160.010 or other standard specified by the Commandant.
46 CFR 180.200(a)(3)
Servicing. Inflatable buoyant apparatus must be serviced periodically at approved servicing facilities in accordance with the applicable requirements of §§ 160.151-35 through 160.151-57. Vessel’s IBA’s next service is due no later than 31MAY2024. Operator to provide documentation that IBA has been serviced by this date, or deficiency will be updated to prior to carriage of passengers.
46 CFR 160-010-3(c)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 May 2024
Resolved 20 May 2024
Resolution: Operator submitted documentation showing proper servicing of IBA.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 7 May 2024
Resolved
At least one ring life buoy must be fitted with a lifeline. If more than one ring life buoy is carried, at least one must not have a lifeline attached. Each lifeline on a ring life buoy must be: buoyant, of at least 60 feet in length, non-kinking, a diameter of at least 5/16 inch, have a breaking strength of at least 1,124 pounds, and be of a dark color if synthetic, or of a type certified to be resistant to deterioration from ultraviolet light. Vessel’s life ring line was severely deteriorated. Operator replaced with new line.
46 CFR 180.70(c)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 May 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 May 2024
Resolved
An adult life jacket must be provided for each person carried on board a vessel. Vessel was missing 03 life jackets. Operator brought 03 additional life jackets from home.
46 CFR 180.71(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 7 May 2024
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 7 May 2024
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radio Beacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel has expired Communications Act Safety Radiotelephony Certificate. Vessel has expired Communications Act Safety Radiotelephony Certificate. Vessel to acquire new Communications Act Safety Radiotelephony Certificate to the satisfaction of the marine inspector.
46 CFR 184.502
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 30 March 2026
Resolution: Replaced with special note.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 24 April 2023
Resolved
Each launching appliance and each survival craft and rescue boat on a vessel must be in good working order and ready for immediate use before the vessel leaves port and at all times when the vessel is underway. The 25 person life float was damaged where the grab lines attached to the float body. Repair or replace the 25 person life float. Any repairs must be in accordance with the manufactures instructions. Vessel is limited to carrying a total of 25 persons until Coast Guard approved survival craft appropriate for the route, and accommodating a total of 46 persons is placed aboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 24 April 2023
Resolved 29 June 2023
Resolution: Received documentation from vessel operator that (02) 25 person Life Floats have been replaced by (01) 50 person IBA.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 7 February 2022
Resolved
A submersible electric bilge pump discharge line must have a positive shutoff valve installed at the hull penetration. The submersible electric bilge pump discharge line for the starboard side engine room submersible electric bilge pump, did not have a positive shutoff valve installed in the discharge line at the hull penetration. Owner must install a positive shutoff valve in the discharge line of the submersible electric bilge pump at the hull penetration.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 March 2022
Resolved 26 April 2022
Resolution: Positive shutoff valve was installed on submersible bilge pump discharge line.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 8 March 2021
Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release for EPIRB is expired. Vessel limited to 3 nautical miles with passengers.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2021
Resolved 26 April 2021
Resolution: Owner provided photo for hydro release
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 8 March 2021
Resolved
The discharge ends of fuel tank vent pipes must be fitted with removable flame screens. The flame screen must consist of a single screen of corrosion resistant wire of at least 30 x 30 mesh. Flame screen for starboard fuel tank vent was holed.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2021
Resolved 13 April 2021
Resolution: Owner provided photo for replaced flame screen
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 28 February 2021
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts or large enough scale to make safe navigation possible. Charts onboard not currently updated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 April 2021
Resolved 13 April 2021
Resolution: Owner provided photo for updated chart.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 12 March 2019
Resolved
The general construction of the vessel shall be such as to minimize fire hazards insofar as reasonable and practicable. Vapor barrier not provided for cables running from the engine room forward. Make bulkhead penetrations vapor tight to prevent vapors from spreading. 46 CFR 177.10-5
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2019
Resolved 22 March 2019
Resolution: Fire stop installed to secure vapor tight boundaries.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 12 March 2019
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. One adult life jacket stowed in the same compartment as the child life jackets. Either use a separator to distinguish between the two sizes or move the adult life jacket.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2019
Resolved 22 March 2019
Resolution: Life jackets have been separated
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 12 March 2019
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Paper charts onboard are from 2013. Update charts with applicable corrections to area of operation or buy new charts.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 April 2019
Resolved 22 March 2019
Resolution: New charts landed
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 12 March 2019
Resolved
The marine employer must have a sufficient number of alcohol testing devices readily accessible on board the vessel to determine the presence of alcohol in the system of each individual who was directly involved in the SMI. Two alcohol testing strips were onboard, however, both expired in 2017. Provide current testing strips. 46 CFR 4.06-15
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 March 2019
Resolved 12 March 2019
Resolution: Owner sent photos of new alcohol test strips.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 12 March 2019
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material. Retroreflective material on the lifefloat was worn. Replace tape.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 12 March 2019
Resolved 12 March 2019
Resolution: Replaced retroreflective tape.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 28 September 2018
Resolved
MMSI: Vsl is broadcasting invalid MMSI
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 8 March 2019
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 14 February 2017
Resolved
Vessel required to present Certificate of Documentation. - 46 CFR 67.7
Action required: 705 - Other - as specified
Due 28 February 2017
Resolved 28 February 2017
Resolution: Operator received new COD and placed it onboard vessel.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 14 February 2017
Resolved
Vessel required to present FCC Safety Radiotelephony certificate due to expiration. - 47 CFR 80.903
Action required: 705 - Other - as specified
Due 14 March 2017
Resolved 14 March 2017
Resolution: Operator presented proof of FCC Safety Radiotelephony certificate.
Engineering › Fuel Oil Service System › Piping
Issued 17 March 2016
Resolved
Properly repair inoperable stbd remote/emergency fuel shut off.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 March 2016
Resolution: Deficiency satisfactorily corrected.