Records from 2016 to 2024. Most recent: inspection, 23 September 2024.
Inspection history · 40
23 September 2024
Administrative Inspection
Administrative · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 8007787
10 July 2024
Deficiency Check
Physical examination · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7957667
6 June 2024
Administrative Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7929372
2 May 2024
COC-CVE Annual · Administrative Inspection · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7905076
13 October 2023
Type not recorded
No type recorded · Sector Maryland-National Capital Region · USCG East District (CGD-E) · Activity 7811052
12 September 2023
Type not recorded
No type recorded · Sector Northern New England · USCG Northeast District (CGD-NE) · Activity 7794328
1 August 2023
COC-CVE Quarterly
Type not classified · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7756721
2 May 2023
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7679244
20 February 2023
COC-CVE Annual · PSC A
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7635032
7 September 2022
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7553601
16 August 2022
PSC B
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 7534589
23 February 2022
COC-CVE Annual
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7391197
14 September 2021
Administrative Inspection
Administrative · Sector San Juan · USCG Southeast District (CGD-SE) · Activity 7311813
5 April 2020
In-Service Inspection
Physical examination · USCG Southeast District (dp) · USCG Southeast District (CGD-SE) · Activity 6935674
3 February 2020
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6901377
11 December 2019
ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6871408
12 November 2019
Deficiency Check
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6853608
22 October 2019
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6839411
12 October 2019
Administrative Inspection · In-Service Inspection
Physical examination · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6833300
12 October 2019
Type not recorded
No type recorded · Sector Key West · USCG Southeast District (CGD-SE) · Activity 6833368
14 June 2019
COC-CVE Annual · Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6717743
17 May 2019
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6686308
12 December 2018
Ballast Water Examination · COC-CVE Quarterly · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6596678
3 August 2018
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6500347
13 July 2018
Administrative Inspection
Administrative · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6482027
18 June 2018
Ballast Water Examination · ISPS III Exam · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6444007
16 May 2018
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6416365
7 May 2018
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6420302
18 December 2017
COC-CVE Quarterly · Ballast Water Examination · ISPS III Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6323791
18 October 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6289967
17 July 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6212353
17 July 2017
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6222388
27 June 2017
Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6188267
19 June 2017
ISPS II Exam · Ballast Water Examination · COC-CVE Annual
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6176489
12 June 2017
In-Service Inspection
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6174366
20 February 2017
In-Service Inspection · Deficiency Check
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6091382
15 December 2016
ISPS II Exam · Ballast Water Examination · COC-CVE Quarterly
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 6058200
17 June 2016
Ballast Water Examination · COC-CVE Annual · ISPS II Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5910259
10 June 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5905879
1 April 2016
Type not recorded
No type recorded · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5845358
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 2 May 2024
Resolved
Sufficient intact stability shall be provided in all service conditions so as to enable the ship to withstand the final stage of flooding of any one main compartment which is required to be within the floodable length. Vessel could not demonstrate cross-flooding devices were operating as intended.
74 SOLAS (04) II-1/8.1.1
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 2 June 2024
Resolved 6 June 2024
Resolution: provided class report attesting to full operation of cross flooding devices.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 August 2023
Resolved
Furniture in stairway enclosures shall be limited to seating. It shall be fixed, limited to six seats on each deck in each stairway enclosure, be of restricted fire risk, and shall not restrict the passenger escape route. Furniture shall not be permitted in passenger and crew corridors forming escape routes in cabin areas. In addition, lockers of non-combustible material, providing storage for safety equipment required by regulations, may be permitted. Portable, non-fixed hand-sanitizing station identified in passenger stairways. 74 SOLAS 01 II-2/41-2.4.10
Action required: 10 - Deficiency Rectified
Resolved 1 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 1 August 2023
Resolved
Fire hoses shall be of non-perishable material approved by the Administration and shall be sufficient in length to project a jet of water to any of the spaces in which they may be required to be used. Each hose shall be provided with a nozzle and the necessary couplings. In interior locations in passenger ships carrying more than 36 passengers, fire hoses shall be connected to the hydrants at all times. Pin hole leak identified in charged fire hose during Fire Drill (deck 6). 74 SOLAS 97 II-2/4.7.1
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Resolved 1 August 2023
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 1 August 2023
Resolved
General arrangement plans shall be permanently exhibited for the guidance of the ship’s officers, showing clearly for each deck, the control stations, the various fire sections, enclosed by “A” class divisions, the sections enclosed by “B” class divisions together with particulars of the fire detection and fire alarm systems, the sprinkler installation, the fire extinguishing appliances, means of access to different compartments, decks, etc., and the ventilating system, including particulars of the fan control positions, the position of dampers and identification numbers of the ventilating fan serving each section. The secondary means of escape from the Cagny restaurant is not clearly identified on the means of escape plan. 74 SOLAS 20 II-2/15.2.4.1
Action required: 10 - Deficiency Rectified
Resolved 1 August 2023
04 - Emergency Systems › N/A - No Subsystem › Abandon ship drills
Issued 1 August 2023
Resolved
Every crew member with assigned emergency duties shall be familiar with these duties before the voyage begins. Stairway guide on embarkation deck, (deck 6) was unfamiliar with their duties regarding muster station locations. 74 SOLAS 20 III/19.2.1
Action required: 10 - Deficiency Rectified
Resolved 1 August 2023
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 1 August 2023
Resolved
Electrical installations shall be such that electrical services for safety will be ensured under various emergency conditions. Emergency light in AC station (deck 4, aft through FSD 40590A) was missing cover and lightbulb. 74 SOLAS 04 II-1/40.1.2
Action required: 10 - Deficiency Rectified
Resolved 1 August 2023
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 1 August 2023
Resolved
Above the bulkhead deck there shall be at least two means of escape from each main vertical zone or similarly restricted space or group of spaces at least one of which shall give access to a stairway forming a vertical escape. Cagny restaurant (CAT 8 public space) secondary means of escape (aft) hidden behind a large curtain, means of escape is fitted with a thumb screw in the direction of escape. 74 SOLAS 97 II-2/28.1.2
Action required: 10 - Deficiency Rectified
Resolved 1 August 2023
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 20 February 2023
Resolved
Passenger ships engaged on international voyages which are not short international voyages shall carry lifeboats complying with the requirements of regulation 42, 43, 0r 44 on each side of such aggregate capacity as will accomadate not less than 50% of the total number of person onboard.
#1 starboard lifeboat experienced propulsion casualty during abandonship drill due to sea painter line wrapping around the lifeboat prop. Due to inoperable lifeboat, a reduction in total number of persons to 3000 in accoradance with short term PSSC issued by DNV.
74 SOLAS (97) III/20.1, 50ac
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2023
Resolved 7 March 2023
Resolution: DNV Class Survey Report states: "Lifeboat No. 1 gear box was repaired, and lifeboat was function tested in the water with satisfactory result."
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 23 February 2022
Resolved
The following fire protection systems shall be kept in good order so as to ensure their required performance if a fire occurs: structural fire protection, including fire-resistant divisions, and protection of openings in these divisions. The following fire screen doors required adjustment: FSD 4046A, 58507A, and 80270A. The following sliding door required adjustment: 70200C. 74 SOLAS 20 II-2/14.2.1.1
Action required: 10 - Deficiency Rectified
Resolved 23 February 2022
Resolution: The identified fire screen doors and sliding door were adjusted.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 23 February 2022
Resolved
A fixed fire detection and fire alarm system of an approved type shall be installed, complying with the requirements of regulation 13 and so installed and arranged as to provide smoke detection. Spaces having little or no fire risk such as voids, public toilets and similar spaces need not be fitted with fixed fire detection. PSCOs observed port and starboard Dive Equipment Lockers to be modified and used as Category 13 spaces per updated Fire Control Plan; lockers now store towels and life jackets presenting a fire risk. Crew removed contents and were instructed that the spaces remain empty until proper fire detection is installed. 74 SOLAS 97 II-2/36.2
Action required: 10 - Deficiency Rectified
Resolved 23 February 2022
Resolution: Crew removed combustible material. The lockers will not be used for storage until fire detection devices are installed.
07 - Fire Safety › N/A - No Subsystem › Jacketed high pressure lines and oil leakage alarm
Issued 23 February 2022
Resolved
Oil fuel lines shall be screened or otherwise suitably protected to avoid as far as practicable, oil spray or oil leakages onto hot surfaces, into machinery air intakes and other sources of ignition. Several fuel pipe flanges have been found without a spray-shield tape or fire protection lagging in both fuel purifying units.
Action required: 10 - Deficiency Rectified
Resolved 23 February 2022
Resolution: Spray-shield tape was added to the fuel pipe flanges on the port and starboard side purifying units.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 23 February 2022
Resolved
All escape route signs and fire equipment location markings shall be marked by lighting or photo luminescent material. PSCOs observed intermittently functioning emergency escape sign near Cabin 60004. 74 SOLAS 97 II-2/28.1.10
Action required: 10 - Deficiency Rectified
Resolved 23 February 2022
Resolution: Vessel fixed the lighting for the emergency escape sign located near cabin 60004.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 11 December 2019
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons onboard. Hose in pool machinery space had leaked into the space and created a potentially hazardous atmosphere.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 11 December 2019
Resolved 11 December 2019
Resolution: rectified on the spot
07 - Fire Safety › N/A - No Subsystem › Fire doors/openings in fire-resisting divisions
Issued 14 June 2019
Resolved
07105 - Fire doors/openings in fire-resisting divisions - Holdback hooks not subject to Central Control station are prohibited. 20+ fire doors did not register as closed at Central Control Station when centrally released.
74 SOLAS (97 CONS) II-2 / 30.4.3
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 June 2019
Resolved 21 June 2019
Resolution: CLASS SURVEYOR ATTENDED THE VESSEL. CREW REPAIRED AND TESTED DOORS SATISFACTORILY. REMOTE CLOSING OF FIREDOORS CONFIRMED AS OPERATIONAL
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 4 August 2018
Resolved
The vessel reported failure of the transitional uninterrupted power supply, which has now been bypassed to facilitate inspection and troubleshooting.
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 August 2018
Resolved 10 August 2018
Resolution: Vessel submitted class report after technicians repaired UPS system and conducted satisfactory test.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 18 June 2018
Resolved
0799 - (other) fire fighting equipment - "A" class divisions shall be so constructed as to be capable of preventing the passage of smoke and flame to the end of the one-hour standard fire test. Fire doors 70384B and 70367A would not prevent the passage of smoke and flame to the end of a one-hour fire test. - 74SOLAS(97 cons)II-2/3.3
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 July 2018
Resolved 13 July 2018
Resolution: Fire doors were adjusted and found satisfactory by class
Fire Fighting › Structural - A Class Divisions › Accommodation Spaces
Issued 18 December 2017
Resolved
74SOLAS (2001) II-2/26.1 - The minimum fire integrity of all bulkhead and decks shall be as prescribed in table 9.1 and 9.2. Identified the crew gym had numerous drilled penetrations through the deck.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 18 December 2017
Operations/Management › Vessel Safety Management › Designated Person(s)
Issued 18 December 2017
Resolved
74SOLAS IV/16.2 - In passenger ships at least one person qualified in accordance with paragraph 1 shall be assigned to perform only radio communication duties during distress incidents. Ships designated GMDSS operator performed other duties during distress incident.
Action required: 705 - Other - as specified
Due 18 December 2017
Resolved 18 December 2017
Operations/Management › Vessel Safety Management › Company Responsibilities/Authority
Issued 17 July 2017
Resolved
Crew did not follow established checklist resulting in flooding of comparment #12, while cleaninig the strainer to the seachest.
Action required: 705 - Other - as specified
Due 31 July 2017
Resolved 27 July 2017
Resolution: Rceived LLoyds report attesting to the correction of ISM issues.
Electrical › Electric Generation Source (service) › Generator
Issued 17 July 2017
Resolved
Generator #4 is inoperable provide class report attesting to proper operation.
Action required: 705 - Other - as specified
Due 28 February 2018
Resolved 16 May 2018
Resolution: Class surveyor verified rewinding of generator and tested to ensure full operational capacity.
Personnel › Training › Familiarization Training
Issued 19 June 2017
Resolved
74 SOLAS ('14 cons) Ch.III/19.2.2.1 - Every crewmember with assigned emergency duties shall be famliar with these duties before the voyage begins. Personnel in charge of bakery was not familiar with fire fighting procedures or release of fixed CO2 suppression. Additionally vice commanders of tender boats were unfamiliar with duties.
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 22 June 2017
Resolution: Received satisfactory evidence that all required training was conducted.
Fire Fighting › Structural Fire Protection - General › Accommodation Space Protection
Issued 19 June 2017
Resolved
74 SOLAS ('97 cons) Ch. II-2/26.4 - In approving structural fire protection details, the Administration shall have regard to the risk of heat transmission at intersetions and terminal points of required barriers. Replace missing insulation in tailor shop and deck 4 chemical storage locker.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 3 July 2017
Resolved 30 June 2017
Resolution: Received picture evidence and Class attestation to rectify deficience.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 June 2017
Resolved
74 SOLAS ('97 cons) Ch II-2/30.1 - All openings shall be provided with permanently attached means of closing which shall be effective for resisting fires. Several fire doors found inoperable and unable to maintain class "A" boundary protection.
Due 19 June 2017
Resolved 19 June 2017
Resolution: 10c - Deficiency rectified during exam.
Lifesaving › Launching Appliances › Davit
Issued 12 June 2017
Resolved
01 - 0630 - Each lifeboat shall be provided with an appliance which is capable of launching and recovering the lifeboat. The number eight port side lifeboat davit is not operational. - 74SOLAS(1997 Cons)CH III/Reg 15.2 - 16ac
Action required: 705 - Other - as specified
Due 26 June 2017
Resolved 13 June 2017
Resolution: Brake control valve was replaced and proper launching of lifeboat to the water was tested several times to the satisfaction of the attending surveyor.
Engineering › Steam Boiler (propulsion) › Piping
Issued 20 February 2017
Resolved
0999 - Safety in General other - Condition of ship and its equip shall be maintained to conform with the provisions of the present reg to ensure that ship in all respects wil remain fit to proceed to sea without danger to the ship. Excessive fuel soaked lagging on boiler #2 and in starboard bilge in the aft engine foom as result of fuel leak on main fuel supply. 74 SOLAS (97 con.) I/11(a)
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 February 2017
Resolution: Lagging was removed from the piping of boiler #2. Boiler #2 was removed from service until lagging/insulation replaced as orig.
Engineering › Fuel Oil Service System › Piping
Issued 20 February 2017
Resolved
0999 - Safety in General other - Machines, boilers and other pressure vessels, associated piping systems and fittings shall be of design and construction adequate for the service for which they are intended and shall be so installed and protected as to reduce to min any danger to persons onboard. Fuel supply line insulation/lagging removed in aft engine room compartment, fuel oil soaked lagging
Condition: Damaged By Earlier Event
Due 4 March 2017
Resolved 27 February 2017
Resolution: Received class survey report from DNV GL confirming that all lagging was replaced for main fuel supply piping to boiler #2.