09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 22 October 2025
Resolved
Emergency lighting must be sufficient to allow crew and passengers to find their way to open decks. Emergency light on EXIT sign in passenger space was not operating. Repair sign/light.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 22 October 2025
Resolved
Each life buoy must be approved under approval series 160.150 and must remain in serviceable condition. All life buoys have significant sun damage and wear on the reflective tape, grab lines, and markings. Replace reflective tape and grab lines and re-stencil vessel name on all life buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Repaired
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 October 2025
Resolved
All life jackets must remain in serviceable condition. Life jackets in the port aft deck box are dirty and show signs of potential wear. Clean and inspect all life jackets in the port aft deck box.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 November 2025
Resolved 3 November 2025
Resolution: Repaired
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 31 July 2025
Resolved
Visual alarms are to be a flashing signal when first activated and change to steady display when acknowledged and must visually and audibly indicate the nature of the condition causing the alarm. Alarm indicator light for High Bilge Level failed to display visual alarm (audible alarm still functioning). Repair visual alarm.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 August 2025
Resolved 31 July 2025
Resolution: Light repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2025
Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. The starboard shaft seal is designed to be "drip free". However, there was a small leak on the seal. Repair shaft seal.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2025
Resolved 18 August 2025
Resolution: Shaft seal repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 31 July 2025
Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. A small oil leak was present on the starboard main engine on an inspection plate near the lower inboard side of the engine. Repair oil leak.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2025
Resolved 18 August 2025
Resolution: Oil leak repaired.
08 - Alarms › N/A - No Subsystem › Closing water-tight doors alarm
Issued 15 April 2025
Resolved
The minimum system monitoring requirement for watertight doors requires that an alarm sounds when a watertight door is in the “open” position. The “open” alarm for the emergency escape hatch was not operating properly. Repair the “open” alarm for the emergency escape hatch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 24 April 2025
Resolution: Alarm repaired
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 April 2025
Resolved
All Lifeboat and rescue boat equipment: Fire Extinguisher. The fire extinguisher must be approved under approval series 162.028. Fire extinguisher was found expired in expired in August 2024.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 23 April 2025
Resolution: Inspected/replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 April 2025
Resolved
All Lifeboat and rescue boat equipment: First aid kit. First Aid kit in the rescue boat was found to be expired.
Action required: 10 - Deficiency Rectified
Due 15 April 2025
Resolved 15 April 2025
Resolution: New-in-kind First Aid Kit obtained from office and placed onbaord prior to completion of inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 15 April 2025
Resolved
Lifeboats and rescue boats. Each lifeboat and rescue boat must be plainly marked as follows: Each side of each lifeboat and rescue boat bow must be marked in block capital letters with the name of the vessel.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 23 April 2025
Resolution: Stenciled vessel name in place.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 14 January 2025
Resolved
Installed Gages on pressure vessels shall have an upper range of no less than 1.2 times nor more than 2 times the reliving valve setting. The relief valve setting on each pressure vessel was 200 psi and the upper range of each gage maxed out at 200 psi. Replace both gages with a range that goes up to 250 psi at least, but no more than 400 psi.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2025
Resolved 14 February 2025
Resolution: Recieved objective evidence (photos) of gauges new-in-kind installed.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 15 October 2024
Resolved
In general, compliance with the standards established by the American Bureau of Shipping will be considered satisfactory evidence of the structural efficiency of the vessel. Two cracked welds were found in the steering space. One of the cracks was on a short athwartships hull stringer and one of the cracks was on a longitudinal strength member in way of the starboard rudder post. The latter crack was exacerbated by metal wastage. Repair hull strength members to the satisfaction of the attending USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2024
Resolved 6 November 2024
Resolution: Strength members repaired
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 15 October 2024
Resolved
Each opening in a watertight bulkhead must have a means to close it watertight. The emergency escape hatch would not properly close. Repair hatch to ensure watertightness.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2024
Resolved 31 October 2024
Resolution: Hatch repaired and closed to watertight condition.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 15 October 2024
Resolved
A vessel required to have Type I or II subdivision must be watertight below the bulkhead deck. Port rudder seal is leaking when vessel is underway. Repair rudder seal to be free of leaks.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2024
Resolved 31 October 2024
Resolution: Rudder seal repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2024
Resolved
Electrical installations on vessels must ensure protection of crew from electrical hazards. Missing breakers of distribution panels on main switchboard were missing covers. Cover empty breaker openings.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2024
Resolved 31 October 2024
Resolution: Openings were covered on panel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 October 2024
Resolved
Each switchboard must have a frequency meter with a selector switch. Frequency meter and selector switch were not functional. Repair meter/switch.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 October 2024
Resolved 31 October 2024
Resolution: Frequency meter repaired.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 19 July 2024
Resolved
Visual alarms are to be a flashing signal when first activated and change to steady display when acknowledged and must visually and audibly indicate the nature of the condition causing the alarm. Alarm indicator light for starboard generator low lube oil pressure was not clearing, although lube oil pressure was present. Alarm was repaired on the spot.
Action required: 10 - Deficiency Rectified
Resolved 19 July 2024
Resolution: Repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 July 2024
Resolved
Electrical installations on vessels must ensure protection of crew from electrical hazards. Emergency light fixture in engine room broke from mounts. Repair light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2024
Resolved 1 August 2024
Resolution: Light repaired/replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 July 2024
Resolved
Bilges must be kept to a minimum content at all times. Steering space, starboard shaft alley, and engine room have accumulated excess water. Pump excess water out of noted spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 August 2024
Resolved 1 August 2024
Resolution: Water removed, bilges observed dry.
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 17 April 2024
Resolved
Visual alarms are to be a flashing signal when first activated and change to steady display when acknowledged and must visually indicate the nature of the condition causing the alarm. Alarm indicator light for low air pressure alarm was not illuminating (audible alarm was still functional). Additionally, the indicators for the low air pressure alarm and the port MDE low oil pressure alarm were not properly labeled. Repair and properly label alarm indicators.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2024
Resolved 22 April 2024
Resolution: Alarm panel properly labeled and illuminating.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 January 2024
Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. There was a coolant leak on the keel cooler piping of the port generator. Repair leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2024
Resolved 1 February 2024
Resolution: Leak repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 January 2024
Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. There was a coolant leak on the keel cooler piping of the starboard generator. Repair leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2024
Resolved 1 February 2024
Resolution: Leak repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 19 January 2024
Resolved
Electric installations on vessels must ensure protection of crew from electrical hazards. Battery box covers were missing. Replace battery box covers.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2024
Resolved 1 February 2024
Resolution: Covers replaced
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 19 January 2024
Resolved
Each ventilation stop must have a nameplate that identifies the system controlled. Properly label ventilation stop.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 February 2024
Resolved 1 February 2024
Resolution: Label installed
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 19 October 2023
Resolved
There must be two means of escape from all general areas where the crew may be normally employed. The port bridge escape door was seized shut. Repair and free up the door for quick escape from the bridge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2023
Resolved 7 November 2023
Resolution: Door repaired
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 October 2023
Resolved
On vehicular ferries, suitable gates shall be installed as a continuation of required rails. The port gate had a large crack in the top rail. Weld/repair crack.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2023
Resolved 7 November 2023
Resolution: Crack repaired
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 19 October 2023
Resolved
Each power motor for main steering gear must have a: "motor running" indicator light in the pilothouse. The light was inop. Install new lamp and test.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2023
Resolved 7 November 2023
Resolution: Lamp repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 October 2023
Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. There was an oil leak on the inboard block of the starboard main engine. Repair leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2023
Resolved 7 November 2023
Resolution: Oil leak repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 19 October 2023
Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. There was a cooling water leak on the starboard generator. Repair leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2023
Resolved 7 November 2023
Resolution: Leak repaired.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 19 October 2023
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed hazards, such as rotating machinery. Shaft coupler for port main engine was expose and posed
a hazard. Place covers in way of main engine shaft
coupling for port main engine.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 November 2023
Resolved 7 November 2023
Resolution: Cover installed.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 17 July 2023
Resolved
Any vessel of at least five net tons which engages in coastwise trade must have a valid Certificate of Documentation. COD expired and newly-applied-for COD has not yet arrived. Provide proof of new COD application.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 26 July 2023
Resolution: New COD onboard
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2023
Resolved
Visual alarms are to be a flashing signal when first activated and change to steady display when acknowledged. Alarm indicator light for starboard generator low lube oil pressure alarm was not operating (audible alarm was still functional). Repair alarm indicator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 26 July 2023
Resolution: Visual alarm repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2023
Resolved
Electrical installations on vessels must ensure protection of crew from electrical hazards. Light fixture in steering space broke from mounts and electrical outlet in wheelhouse was missing a cover. Make repairs to light and outlet.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 26 July 2023
Resolution: Light fixture repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 July 2023
Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. The cooling water header on the starboard main engine has a pinhole leak. Repair leak.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 26 July 2023
Resolution: Engine repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2023
Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. The port steering ram linkage was missing a cotter pin. Replace cotter pin.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 26 July 2023
Resolution: Linkage repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 17 July 2023
Resolved
The material, design, workmanship, and arrangement must be equivalent to ABS standards for engineering systems. The feed water to the sewage system has a cracked union and is leaking water into the engine room bilge. Repair cracked union.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 26 July 2023
Resolution: Feed water union tightened. Leak repaired.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 17 July 2023
Resolved
The vessel's Coast Guard-issued stability letter states that the vessel's bilges and voids shall be kept pumped to minimum content at all times consistent with pollution prevention requirements. The steering space bilge contains 3-4 inches of water throughout the bilge. Remove all water from steering space bilge.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 31 July 2023
Resolved 26 July 2023
Resolution: Water removed from bilge.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 19 April 2023
Resolved
The minimum system monitoring requirement for reduction gears requires a high lube oil temperature alarm. During testing, high lube oil temp alarm for port reduction gear failed. Repair alarm.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 May 2023
Resolution: Alarm sensor repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 April 2023
Resolved
The minimum system monitoring requirement for generators requires a high cooling water temperature alarm. During testing, high cooling temp alarm for port generator failed. Repair alarm.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 3 May 2023
Resolution: Alarm sensor repaired
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 19 April 2023
Resolved
Fire pumps shall be fitted with a pressure gauge on the discharge side of the pumps. No gauge was installed. Install gauge.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 May 2023
Resolution: Gage installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 April 2023
Resolved
Each cable installation must meet IEEE 45-2002. Each
vertical cable must be supported every 610mm with metal
straps. Electrical installations on vessels must ensure protection of crew from electrical hazards. Repair loose wiring in void spaces.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 May 2023
Resolution: Wires properly braced.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 24 January 2023
Resolved
Each lighting fixture must be fixed. Emergency light in engine room is broken and the bulbs fixtures were hanging by the wires. Repair emergency light.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 7 February 2023
Resolution: Repaired
03 - Water/Weathertight Conditions › N/A - No Subsystem › Doors
Issued 24 January 2023
Resolved
Each Class 1 watertight door must be operative from both sides of the door and must be designed to withstand a head of water equivalent to the depth from the sill of the door to the margin line but in no case less than 10 feet. Watertight doors for both shaft alleys and for the steering space were difficult to operate and may be out of adjustment. Repair doors and prove watertightness by chalk test or other means in presence of marine inspector.
Action required: 705 - Other - as specified
Due 7 February 2023
Resolved 3 May 2023
Resolution: Gaskets replaced on doors
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 24 January 2023
Resolved
Visual alarms are to be a flashing signal when first activated and change to steady display when acknowledged. Alarm indicator light for starboard generator low lube oil pressure alarm was not operating (audible alarm was still functional). Repair alarm indicator.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 7 February 2023
Resolution: Repaired
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 24 January 2023
Resolved
Suitable guards shall be installed in way of dangerous places. Inboard of port main engine, a hinged deck plate
is broken, causing a tripping hazard near the machinery. Repair deck plate to eliminate tripping hazard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 7 February 2023
Resolution: Repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 January 2023
Resolved
All pressure relief valves for use on pressure vessels shall be set to relieve at a pressure which does not exceed the maximum allowable working pressure of the pressure vessel it services. Relieving pressure markings for the relief valves on the air receivers were painted over and inspector could not ascertain the relief valve setting. Prove proper relief valve setting.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 February 2023
Resolved 7 February 2023
Resolution: Scratched off paint so that PRV data plates legible. They were below MAWP.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 24 January 2023
Resolved
Fixed firefighting systems must be checked as noted in table 71.25-20(a)(2) at each annual inspection. Inspectors are not limited from making tests deemed necessary to ensure the safety of the vessel. CO2 system was inspected/tested in December 2022 without test being witnessed by USCG Marine Inspectors. Complete CO2 system testing in presence of USCG Marine Inspectors during next COI inspection.
Action required: 705 - Other - as specified
Due 25 April 2023
Resolved 3 May 2023
Resolution: USCG Inspectors witnessed test of CO2 system, all satisfactory.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 7 November 2022
Resolved
Each lighting fixture must be fixed. Lighting fixture in port side steering space fell from its mounts. Repair lighting fixture.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2022
Resolved 2 December 2022
Resolution: Fixture repaired
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 7 November 2022
Resolved
A vessel of 12 meters of more in length shall be provided a whistle. While making several blasts of whistle during a fire drill, breaker for ship's whistle tripped, but was able to be reset. Inspect whistle circuit to prevent failure of ship's whistle.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2022
Resolved 2 December 2022
Resolution: Breaker only trips if horn is used excessively and the horn has a secondary pull that alllows operator to operate horn even if breaker is tripped.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 7 November 2022
Resolved
Each life jacket aboard vessel must be approved under approval series 160.155, 160.176, or 160.177. Additionally, each life jacket container must be marked with the proper quantity of life jackets within. 1 adult size life jacket were found unserviceable. Unserviceable life jackets were in excess of required carriage amount. Replace unserviceable life jackets or change label on container to match actual number within (if unserviceable life jackets will not be replaced).
Action required: 16 - Rectify deficiencies w/in 14 days
Due 21 November 2022
Resolved 2 December 2022
Resolution: Life jackets replaced
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 August 2022
Resolved
At least once every twelve months, all hand portable fire extinguishers must be inspected. The vessel's firefighting equipment shall be ready for use at all times. Portable fire extinguishers were past due inspection and extinguisher #1 in the engine room needed to be recharged. Inspect extinguishers in accordance with NFPA standards and repair undercharged extinguisher.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 August 2022
Resolution: Fire extinguishers received annual inspection and faulty FE in engine room was replaced.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 5 August 2022
Resolved
A vessel required to have Type I or II subdivision must be watertight below the bulkhead deck. Wire runs through bulkhead between steering room and shaft alley were not watertight. Make wire runs water tight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 17 August 2022
Resolution: Wire runs repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2022
Resolved
Non-conducting deck coverings, such as non-conducting mats or gratings, suitable for the specific switchboard voltage must be installed for personnel protection at the front and rear of the switchboard and must extend the entire length of, and be of sufficient width to suit, the operating space. Non-conducting mats are missing in from of the switchboard. Install required mats.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 31 August 2022
Resolution: Mats installed
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 5 August 2022
Resolved
Ground indicators must be at the ship's service generator distribution switchboard. Ground indicator was not operating properly. Repair ground indicator on switchboard.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 17 August 2022
Resolution: Ground detector operasting properly
08 - Alarms › N/A - No Subsystem › Steering gear alarm
Issued 5 August 2022
Resolved
An audible and visible alarm must activate in the machinery space upon occurrence of low oil level in steering system and other alarms. Alarm activated and was visible, but inaudible when machinery was running in the engine room. Ensure steering alarms are audible in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 17 August 2022
Resolution: New horn installed, alarm is now audible
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 5 August 2022
Resolved
An audible and visible alarm must activate in the machinery space upon occurrence of low oil level in steering system and other alarms. Alarm activated and was visible, but inaudible when machinery was running in the engine room. Ensure steering alarms are audible in the engine room.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 17 August 2022
Resolution: Shaft tachs repaired, operate in both wheelhouse and engine room
09 - Working and Living Conditions › 092 - Working Conditions › Other (working space ILO)
Issued 5 August 2022
Resolved
Spaces having a secondary means of escape which is not obviously apparent shall have a suitable sign in red letters "EMERGENCY EXIT" directing attention to such escape. Emergency escape route in steering room not clearly marked. Mark route as indicated.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 17 August 2022
Resolution: Escape route marked
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 5 August 2022
Resolved
Each life jacket container must be marked with the quantity of the equipment stowed within the container. Life jacket containers were marked with the incorrect amount. Mark containers with the correct amount of life jackets within.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 August 2022
Resolved 17 August 2022
Resolution: Life jackets replaced to match marked number
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 25 April 2022
Resolved
Drills must be held before sailing when a vessel enters service for the first time, after modification of a major character, or when a new crew is engaged. Complete all required drills under supervision of parent OCMI prior to sailing.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 May 2022
Resolved 8 June 2022
Resolution: Drills were satisfactory.
11 - Life Saving Appliances › N/A - No Subsystem › Launching arrangements for rescue boats
Issued 25 July 2018
Resolved
Each renewal of certification and periodic inspection shall include a demonstration of the proper condition of the rescue boat launching appliance. The wire rope of the rescue boat launching davit was crushed. Wire rope must be replaced and weight test must be conducted.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 18 September 2018
Resolution: Cable replaced with new line. Satisfactory weight test conducted with 1320 LB weight.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Other (load lines)
Issued 25 July 2018
Resolved
If an electric cable passes through a main transverse watertight bulkhead, the opening through which it passes must be watertight. Wire runs through watertight bulkheads in engine room were not watertight.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 8 August 2018
Resolution: Wire runs repaired to make watertight.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 July 2018
Resolved
Electric installations on vessels must ensure protection of crew from electrical hazards. Dead-end wires were found near bridge console and needs to be removed.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 August 2018
Resolved 8 August 2018
Resolution: Dead end wires removed.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 11 December 2017
Resolved
Port MDE jacket water high temperature alarm would not sound at the set limit.
Condition: Invalid
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 11 January 2018
Resolution: Port MDE jacket water high temperature alarm SAT - audible and visual.
Engineering › Reduction Gearing/Clutches › Gear
Issued 11 December 2017
Resolved
Port Reduction Gear high oil temperature alarm not providing visual or audible alert.
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 11 January 2018
Resolution: Port Reduction Gear high oil temperature alarm tested - SAT.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 11 December 2017
Resolved
All portable fire extinguishers were past due for annual service.
Action required: 705 - Other - as specified
Due 13 December 2017
Resolved 13 December 2017
Resolution: All portable fire extinguishers were serviced and tagged by a licensed company.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 11 December 2017
Resolved
Both MDE's had sections of missing or improperly installed high temp exhaust piping shielding/lagging.
Action required: 705 - Other - as specified
Due 11 January 2018
Resolved 11 January 2018
Resolution: Missing exhaust lagging was installed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 September 2017
Resolved
Label Fwd ring buoy with vessel name IAW 46 CFR 199.70 (a)(2).
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 6 October 2017
Resolution: Ringbuoy re-stenciled
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 21 September 2017
Resolved
Re-attach aft lifebuoy buoyant lifeline IAW 46 CFR 199.70 (a)(3)(E)(ii).
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 6 October 2017
Resolution: Re-attached lifeline to ringbuoy body.
Documentation › Markings/Placards › Warning Signs
Issued 21 September 2017
Resolved
Re-post IBA launching instructions with new readable copy IAW 46 CFR 199.90.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 6 October 2017
Resolution: New launching instructions posted.
Engineering › Diesel Engine (propulsion-reduction gear) › Camshaft
Issued 21 September 2017
Resolved
Repair oil leak on port MDE inboard camshaft cover, cover plate is missing a bolt and is leaking oil, IAW 46 CFR 58.05-1.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 6 October 2017
Resolution: Oil leak repaired.
Electrical › Electric Supply System (service) › Cable
Issued 21 September 2017
Resolved
Permanantly mount or remove identified electrical junction boxes in E/R IAW 46 CFR 111.60.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 6 October 2017
Resolution: Identifed junction boxes were either removed or re-attached.
Electrical › Electrical Distribution System (service) › Metallic Enclosure/Frame
Issued 21 September 2017
Resolved
Fix latch for door on main distribution to the back panel side IAW 46 CFR 111.30-1.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 6 October 2017
Resolution: Latch repaired and proved operation.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 21 September 2017
Resolved
Repair or replace "E" light bulb in stbd E/R bulkhead light IAW 46 CFR 111.75-15 (c)(2).
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 6 October 2017
Resolution: New buld installed and tested.
Electrical › Lighting (service) › Lighting Fixture
Issued 21 September 2017
Resolved
Repair or replace IBA embarcation light. Light is broken and pointing downward.
Action required: 705 - Other - as specified
Due 6 October 2017
Resolved 6 October 2017
Resolution: Light repaired and tested satissfactory.