MAURY USCG vessel records
← All vessels

BOSTON ELITE

BOSTON ELITE is a 1977 passenger vessel (inspected). The Coast Guard has recorded 24 inspections since 2016, most recently in December 2025, along with 47 deficiencies.

Records from 2016 to 2025. Most recent: inspection, 16 December 2025.

Built
1977
Last inspected
16 December 2025
Documentation
Case Pending · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 16 December 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDJ5159
Flag
UNITED STATES
Maury page id
psix-49229

Documentation record

Registered dimensions (L × B × D)96.7 ft × 21.7 ft × 7.1 ft
Registered tonnagegross 95 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSWIFTSHIPS INC · MORGAN CITY, LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portBOSTON, MA
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 15 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it95 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 24

16 December 2025 Vessel Attendance · Internal Structural Exam · Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8268619
21 January 2025 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8062846
3 December 2024 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 8042403
15 November 2023 Internal Structural Exam · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7818790
26 April 2023 In-Service Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7671781
7 February 2023 Internal Structural Exam · Deficiency Check · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7628158
16 November 2022 Annual Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7581619
28 July 2022 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7518562
29 November 2021 COI Inspection · Internal Structural Exam
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7354200
7 May 2021 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7186174
22 January 2021 Drydock Extension
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7128745
22 December 2020 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 7115108
7 February 2020 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6904621
19 December 2019 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6874525
16 September 2019 Damage Survey
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6815037
30 January 2019 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6617213
13 December 2018 Deficiency Check · Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6593468
23 February 2018 Examination of Repairs · Deficiency Check · Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6360233
13 December 2017 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6323532
5 December 2017 Annual Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6317517
18 April 2017 Administrative Inspection
Administrative · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6127052
3 February 2017 Examination of Repairs · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6082420
14 December 2016 Deficiency Check · COI Inspection
Physical examination · Sector Boston · USCG Northeast District (CGD-NE) · Activity 6057551
4 January 2016 Annual Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector Miami · USCG Southeast District (CGD-SE) · Activity 5790195

Deficiency record · 47

11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 16 December 2025 Resolved
Each ring life buoy on a vessel must:(1) Be approved in accordance with § 160.050 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.150. Ring buoy located on starboard bow was dry rotted and the grab line was beginning to fray.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 December 2025
Resolved 17 December 2025
Resolution: Operator provided a photograph showing new lifering installed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 3 December 2024 Resolved
On vessels of at least 26 feet in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. The high water alarm in the bilge of the Bridal Suite was not secured to the structure of the vessel.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 5 December 2024
Resolution: Vessel representative submitted photo evidence of deficiency corrected.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 December 2024 Resolved
Electrical equipment on a vessel must be maintained to minimize accidental personnel contact with energized parts. An electrical junction box located in the void space below the Bridal Suite was found loose/open.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 5 December 2024
Resolution: Vessel representative submitted photo evidence of deficiency corrected.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 3 December 2024 Resolved
A penetration in a watertight bulkhead must be made watertight. An electrical penetration in the forward starboard watertight bulkhead of the engine room was not properly made watertight after recent cable installation.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 December 2024
Resolved 5 December 2024
Resolution: Vessel representative submitted photo evidence of deficiency corrected.
02 - Structural Conditions › N/A - No Subsystem › Bulkheads - cracking
Issued 3 December 2024 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight. A weld on the forward port watertight bulkhead of the galley had cracked metal a few inches long. Repair required for drydock credit. Repair required for drydock credit.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 30 January 2025
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 22 December 2020 Resolved
46CFR58.01-20 Gears, couplings, flywheels and all machinery capable of injuring personnel shall be provided with adequate covers or guards.During examination, MI noted that the flywheel on the bow thruster did not have a cover or guard over it. Ensure that crew members are safe during operation of the bow thruster.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 January 2021
Resolved 29 December 2020
Resolution: Company submitted operational procedures that the bow thruster engine will not be operational while people are in the engine room.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 22 December 2020 Resolved
46CFR185.606 All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”, unless such markings are deemed unnecessary by the cognizant OCMI. The emergency escape hatch in the galley was labeled in Spanish. Install marking in English as well.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 January 2021
Resolved 29 December 2020
Resolution: Emergency escape hatch has been appropriatly marked
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 December 2020 Resolved
46CFR176.25-5(a)(5) At each initial and subsequent inspection for certification, the marine inspector shall check the condition of the superstructure, flying bridge, masts, stacks, and similar arrangements constructed on the hull. During examination of the pilot house, MI observed water pouring from the ceiling through the vessel’s spotlight. Make repairs in kind to restore the weathertight integrity to the satisfaction of the attending MI.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 January 2021
Resolved 29 December 2020
Resolution: Ice dam was located on pilot house room. After removeal of ice dam, water stopped entering pilot house.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 19 December 2019 Resolved
Each watertight bulkhead must be of sufficient strength to be capable of remaining watertight with a head of water to the top of the bulkhead. The vessel has four penetrations in watertight bulkheads thus not creating a watertight barrier. The compromised bulkheads are between the engine room and tool room (one penetration) and the galley forward to the bridal suite (three penetrations).
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 3 January 2020
Resolution: Verified that all penetrations have been made watertight.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 December 2019 Resolved
All wiring and cables shall be suitable for marine service and for the particular instillation used. Flexible or portable cords cannot be used for permanent installed wiring. The vessel is utilizing multiple extension power cords throughout the vessel including the pilot house, managers space below deck, and the pantry aft of the pilot house. 46CFR183.10-20(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 3 January 2020
Resolution: Verified the removal of all extension chords.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 December 2019 Resolved
Electrical equipment must be installed and maintained to protect passengers and crew from electrical hazards, including electrical shock. The fuse box in the bridal suite is missing its breaker box cover presenting an electrical shock hazard.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 3 January 2020
Resolution: Verified the installation of a cover over the breaker box.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 December 2019 Resolved
Electrical equipment must be installed and maintained to protect passengers and crew from electrical hazards, including electrical shock. There is an exposed wire in the ceiling in the tool room, presenting an electrical hazard to the crew.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 3 January 2020
Resolution: Verified the instillation of a wire cap and electrical box around the wire.
04 - Emergency Systems › N/A - No Subsystem › Location of emergency installations
Issued 19 December 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from all passenger and crew accommodation spaces located below the main deck. The emergency route from the bridal suite to the main deck does not have emergency lighting installed in the female head, which is along the emergency route.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 3 January 2020
Resolution: Verified the instillation of emergency lighting and signs for the emergency route.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 19 December 2019 Resolved
Hatch covers must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. The hatch cover in the most forward space is not attached or otherwise made to prevent its loss.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 January 2020
Resolved 3 January 2020
Resolution: Verified the instillation of a retention cable for the hatch cover.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 January 2019 Resolved
Under the centerline engine, in the 2nd bay from forward on the starboard side of the keel, provide a repair proposal on repairing/replacing the 3/4" diameter pit (approx 1/4" deep) in the hull plating.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 7 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 30 January 2019 Resolved
Free up the frozen sea valve for the bilge/fire pump in the machinery space starboard side forward.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 8 February 2019
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 January 2019 Resolved
Clad weld several pits on the bottom plating in the machinery space in the bay aft of the centerline engine.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 7 February 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 January 2019 Resolved
Replace the broken gate valve in the galley for the A/C unit.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 5 March 2019
Resolved 8 February 2019
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2018 Resolved
Cables entering boxes must be protected from abrasion and secured to the box by a fitting. Individual conductors on starboard A/C unit in galley and not secured to unit.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 21 December 2018
Resolution: Exposed portions of wiring fed into unit with proper fitting
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2018 Resolved
Each connection to a conductor or terminal part must be made within an enclosure. Open electrical junction boxes found in manager's office and laz.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 13 December 2018
Resolved 21 December 2018
Resolution: Electrical covers installed in open junction boxes in manager's office and laz.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 13 December 2018 Resolved
Check condition of arrangements constructed on the hull. Repair welds identified by marine inspector in laz on port quarter and on overhead support beam amidships.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 January 2019
Resolved 11 January 2019
Resolution: Welds were repaired in the laz.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 13 December 2018 Resolved
Suitable guards and rails shall be installed in way of exposed gears or machinery. Forward rotating gear pulley on main engines exposed.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 21 December 2018
Resolution: Guard installed on forward part of engine.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 13 December 2018 Resolved
Each lifejacket must be marked with Type 1 retro reflective material. 05 Lifejackets identified with worn or missing retro reflective material.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 13 December 2018
Resolved 13 December 2018
Resolution: Life jackets removed from service. Vessel remaining lifejacket count meets passenger carry requirements.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 13 December 2018 Resolved
One ring buoy must be fitted with a life line of at least 60 feet. Provided lifeline is of inadequate length.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 21 December 2018
Resolution: Line of proper length was provided
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 December 2018 Resolved
Each connection to a conductor must be made in an enclosure. Forward embarkation light has exposed wires.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 December 2018
Resolved 21 December 2018
Resolution: Removed wire.
Construction/Loadline › Hull › Bottom Plating
Issued 23 February 2018 Resolved
Repair replace bottom plate that is wasted IWO engine room , aft compartment.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2018
Resolved 1 May 2018
Resolution: Plate replacement is completed, test sat.
Construction/Loadline › Hull › Side Shell
Issued 3 February 2017 Resolved
Crop and renew to good metal the pitted side shell plating in the following locations; a. The starboard side shell from forward of the main engine exhaust and cooling water overboard aft to the transom (approximately 37' X 24" high). b. The port side shell from just forward of the main engine exhaust and cooling water overboard aft approximately 10' (approximately 10' X 24" high).
Action required: 705 - Other - as specified
Due 31 January 2018
Resolved 5 March 2018
Resolution: Side shell plate repaired, tested sat.
Construction/Loadline › Hull › Bottom Plating
Issued 4 January 2017 Resolved
Crop and renew pitted area in way of port side work shop fwd of engine room. Pits were found to be nearly 3/8" thick.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2017
Construction/Loadline › Penetrations › Pipe Flange
Issued 4 January 2017 Resolved
Crop and renew spool piece on stbd M/E raw water exhaust.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 March 2017
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 14 December 2016 Resolved
Stencil vessel name on bow and stern.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2016
Resolution: Name stenciled on vessel.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 14 December 2016 Resolved
Paint draft marks in a contrasting color.
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 4 January 2017
Resolution: Draft markes painted.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 14 December 2016 Resolved
Stencil liferings with current vessel name.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 December 2016
Resolution: New life rings with name provided.
Electrical › Electric Generation Source (service) › Ground Indicator
Issued 14 December 2016 Resolved
Locate and eliminate 8 AMP ground on main switch board.
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 4 January 2017
Resolution: Multiple grounds were found and corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2016 Resolved
Remove or properly terminate dead end wire beneath galley deck.
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 4 January 2017
Resolution: Dead end wire placed on a junction box.
Engineering › Pressure Vessel › Relief Valve
Issued 14 December 2016 Resolved
Renew pressure relief valves on both pressure vessels.
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 4 January 2017
Resolution: New relife valves installed and tested.
Construction/Loadline › Penetrations › Valve Flange
Issued 14 December 2016 Resolved
Remove sealant on STBD M/E raw water overboard discharge valve. Sealant appears to be covering pin holes in spool piece.
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 24 March 2017
Resolution: Sealent removed for inspection. Subsequent 835 issued to crop and renew spool piece.
Engineering › Freshwater System (jacketwater cooling) › Sensor
Issued 14 December 2016 Resolved
Prove proper operation of M/E cooling water gauges. 46 CFR 182.20-5
Action required: 705 - Other - as specified
Due 6 January 2017
Resolved 31 March 2017
Resolution: Verified engine gauges are operational.
Engineering › Bilge Water Management System › Interface Detector
Issued 4 January 2016 Resolved
Prove operation of bilge high water float in pump room.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 17 February 2016
Resolution: Bilge float was rewired and tested successfully.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 January 2016 Resolved
Seal penetration in bulkhead, port side of aft WTD in E/R.
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 17 February 2016
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 January 2016 Resolved
Plug pipe for former generator air starter in bulkhead separating gen. room & E/R.
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 17 February 2016
Stability › Unintentional Flooding › General
Issued 4 January 2016 Resolved
Secure water tanks and water heater in pump room.
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 17 February 2016
Resolution: All tanks secured utilizing metallic straps.
Fire Fighting › Nozzles › Condition
Issued 4 January 2016 Resolved
Replace nozzle for forward fire hose station.
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 17 February 2016
Accommodation/Occupational Safety › Cooking Systems › CNG System Requirements
Issued 4 January 2016 Resolved
Provide locking mechanism and side rail for stove IWO egress path in galley.
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 17 February 2016
Communications › Alarms/Indicators › Lube Oil Level Alarm
Issued 4 January 2016 Resolved
Repair port engine alarm/high drive oil pressure indicator.
Action required: 705 - Other - as specified
Due 1 March 2016
Resolved 1 March 2016
Resolution: The owner/operator discovered that the issue was caused by a component vibrating loose. Verified operation and cleared deficiency.
Operations/Management › Drug and Alcohol Testing › EAP Training Requirements
Issued 4 January 2016 Resolved
Provide EAP training.
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 17 February 2016
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 4 January 2016 Resolved
Repair bulkhead penetration, firemain gen. room, forward port.
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 17 February 2016
Electrical › Electrical Distribution System (service) › Junction Box
Issued 4 January 2016 Resolved
Secure junction box in laz.
Action required: 705 - Other - as specified
Due 18 January 2016
Resolved 18 February 2016

Ownership record