Records from 1985 to 2023. Most recent: inspection, 24 May 2023.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 1 November 2022
No resolution recorded
The railing near the EPIRB was broken at the weld. Reweld to original condition prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 1 November 2022
No resolution recorded
The guards for heating coils in two (02) staterooms were detached. Re-installl guards over the heating coils.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 1 November 2022
No resolution recorded
Vessel was not operational due to offseason. Vessel operator has not logged crew drills, EPIRB tests or lifesaving maintenance. Log all required items to be logged.
Action required: 701 - Prior to carriage of passengers/cargo
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 1 November 2022
No resolution recorded
Vessel's stern light and starboard running light did not operate as required. Repair navigation lights to original condition prior to operating at night or reduced visibility.
Action required: 705 - Other - as specified
01 - Certificates & Documentation › 013 - Documents › Signs, indications
Issued 1 November 2022
No resolution recorded
The maximum passengers on top deck sign was incorrectly marked with the number of passengers as per the stability letter. Correctly mark the maximum number of passengers allowed on the top deck as per the stability letter prior to carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2021
Resolved
The life ring bouy's floating light battery was expired. Renew floating light battery to original condition.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2021
Resolved 13 August 2021
Resolution: Battery renewed.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 3 August 2021
Resolved
Provide proof of EPIRB registration.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2021
Resolved 13 August 2021
Resolution: EPIRB registered.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 August 2021
Resolved
Certificate of Documentation was not onboard for inspection. Provide original Certificate of Documentation onboard vessel.
Action required: 17 - Rectify deficiencies prior to departure
Due 4 August 2021
Resolved 13 August 2021
Resolution: COD onboard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 3 August 2021
Resolved
The life ring bouy floating line was made of a material that did not float. Provide lifeline on bouy that is buoyant, at least 60 ft in length, non-kinking, at least 5/16" diameter, and dark in color if synthetic or of a type that is certified to be resistant to deterioration from u/v light.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 August 2021
Resolved 13 August 2021
Resolution: Line installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 3 August 2021
Resolved
Provide record of lifesaving and firefighting maintenance.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 August 2021
Resolved 13 August 2021
Resolution: Records onboard.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 August 2021
Resolved
Crew only area on the port side catwalk was missing the chain to keep passengers from entering restricted area. Renew/replace chain divider.
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 August 2021
Resolved 13 August 2021
Resolution: Chains installed.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 25 May 2021
Resolved
Flexible Hose on tern tube seal requires two corrosion resistant hose clamps. Clamps on both the port and starboard stern tube seal, packing glands are heavily corroded to the point of potential failure.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 June 2021
Resolved 3 August 2021
Resolution: Clamps were renewed.
10 - Safety of Navigation › N/A - No Subsystem › Record of drills and steering gear tests
Issued 9 September 2020
Resolved
Vessel crew must successfully complete crew proficiency drills (fire, man overboard, abandon ship) in the presence of a attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2021
Resolved 3 August 2021
Resolution: Drills satisfactorily completed.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 9 September 2020
Resolved
First aid kit contains expired medications and missing items. Renew first aid kit to original condition.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 3 August 2021
Resolution: new first aid kit installed onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 9 September 2020
Resolved
Emergency lights did not operate with power outage. Ensure emergency lights operate as required.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 April 2021
Resolved 3 August 2021
Resolution: Emergency lighting was operable and tested sat.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 9 September 2020
Resolved
The three red (nighttime) distress signals were expired. Provide 3 red distress signals.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 April 2021
Resolved 3 August 2021
Resolution: New distress signals installed onboard.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 9 September 2020
Resolved
EPIRB battery was expired. Renew battery prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 1 April 2021
Resolved 3 August 2021
Resolution: Epirb battery was renewed.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 September 2020
Resolved
Markings on both life rings were illegible. Renew markings on ring buoys.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 3 August 2021
Resolution: Life ring markings remarked.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 9 September 2020
Resolved
Stern light was extinguished. Renew stern light.
Action required: 60 - Rectify deficiencies prior to movement
Due 1 April 2021
Resolved 3 August 2021
Resolution: All nav lights operational.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 9 September 2020
Resolved
Port fuel shutoff rod was attached to gate vlave with a plastic wire tie. Replace plastic wire tie with metallic one.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 October 2020
Resolved 3 August 2021
Resolution: Metal wire was installed on valve.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 5 September 2019
Resolved
Vessel did not have a vlaid COD onboard. Renew COD and provide proof to attending Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2020
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 September 2019
Resolved
Provide new or updated charts.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2020
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 September 2019
Resolved
Vessel's radio station license and radio telephony certificate were expired. Renew and provide proof to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2020
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 5 September 2019
Resolved
Epirb registration was expired. Renew and provide proof to attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2020
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 5 September 2019
Resolved
Provide proof of Marine Radio Operator permit for vessel master.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 9 September 2020
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 5 September 2019
Resolved
Three orange smoke distress signals were expired. Provide three new orange smoke distress signals.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 September 2020
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 September 2018
Resolved
1) Prove proper operation of starboard running light.
Action required: 705 - Other - as specified
Resolved 25 September 2018
Resolution: Vessel has repaired starboard running light
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2018
Resolved
Provide means to conduct alcohol testing of each crew members onboard.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2018
Resolution: Vessel has bought new alcohol testing strips.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 5 September 2018
Resolved
Prove annual servicing of engine room aft portable fire extinguisher.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2018
Resolution: Vessel has had engine room aft portable fire extinguisher serviced.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 5 September 2018
Resolved
Provide up to date Coast Guard Light list.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 September 2018
Resolution: Vessel has a up to date Coast Guard Light List onbaord
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 September 2018
Resolved
Provide and display/distribute the Employer’s policy on drug and alcohol use in the work place.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2018
Resolution: Vessel has provide and display/distribute the Employer’s policy on drug and alcohol use in the work place
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 5 September 2018
Resolved
Provide 3 fire buckets as per 46 CFR 181.610
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2018
Resolution: Vessel has provide 3 fire buckets.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 5 September 2018
Resolved
Reinstall smoke detector in the starboard fwd. berth.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 September 2018
Resolution: Vessel has installed new smoke detector
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 5 September 2018
Resolved
Install guard on starboard fwd. upper bunk light.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 September 2018
Resolution: Vessel has reinstalled light guard.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 29 August 2017
Resolved
emergency lighting was not working
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 September 2017
Resolution: Vessel fixed all all emergency lighting
Electrical › Lighting (service) › Lighting Fixture
Issued 29 August 2017
Resolved
Multiply lighting fixtures were missing covers
Action required: 705 - Other - as specified
Due 29 September 2017
Resolved 20 September 2017
Resolution: Vessel installed new covers on all lighting fixtures
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 29 August 2017
Resolved
Stern light was not working. Vessel to repair before night time operations
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2017
Resolution: Vessel fixed stern light
Lifesaving › Launching Appliances › Release Mechanism
Issued 29 August 2017
Resolved
Hydraulic release was expired.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 September 2017
Resolution: Vessel has Install new EPRIB hydraulic release
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 16 October 2014
Resolved
Add railing spacing as per regs on STBD side step down to upper deck & around area portside where chest freezer is located, rail staggered 90 degree.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 April 2015
Resolved 23 June 2015
Resolution: Confirmed, sat.
Stability › Incline Test › General
Issued 23 July 2012
Resolved
Stability Letter is from 1999 and does not identify the total persons allowed onboard. Vessel's current COI is restricted to 25 persons only due to owner/operator's IBA. Otherwise, vessel used to carry up to 53 persons onboard with overnight accomodations for 21 persons.
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 27 August 2012
Resolution: Reduced passengers based on previous certification for 53 persons onboard. Vessel''s stability letter now authroizes satisfactory stability for 44 total persons on exposed waters.
Lifesaving › Hand Flares › Not on Board
Issued 23 July 2012
Resolved
Equip vesselw ith proper distress signals prior to carrying passengers unless on a short run 30 minutes away from the dock.
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 8 August 2012
Resolution: Verified the proper amount of distress signals and expiration dates.
Electrical › Lighting (emergency) › Battery Operated Lantern
Issued 23 July 2012
Resolved
Make repairs to emergency lighting. Provide all below main-deck passengers with access to flashlights until repairs have been made.
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 8 August 2012
Resolution: Witnessed operation of emergency lighting.
Communications › Alarms/Indicators › Fire Alarm
Issued 23 July 2012
Resolved
Replace all missing smoke detectors.
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 8 August 2012
Resolution: Verified installation and testing of smoke detectors.
Documentation › Manuals/Policy Documentation › Bridge Resource Management Policy/Procedures
Issued 23 July 2012
Resolved
Provide vesselw ith updated purblication of Navigation Rules.
Action required: 705 - Other - as specified
Due 3 August 2012
Resolved 8 August 2012
Resolution: Verified onboard Navigational Rules publication.
Lifesaving › Inflatable Liferafts › Not on Board
Issued 4 May 2009
Resolved
Proof of service of Liferaft available; Liferaft not onboard.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2009
Lifesaving › Hand Flares › Expired
Issued 4 May 2009
Resolved
In need of 3 Red Hand Flares
Action required: 17 - Rectify deficiencies prior to departure
Resolved 8 May 2009
Operations/Management › Drills/Instruction › Not Conducted
Issued 30 September 2008
Resolved
Demonstrate fire, man overboard and abandon ship drills to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2009
Documentation › Logs/Records › Drug Test Records
Issued 30 September 2008
Resolved
Provide proof of enrollment for master and crew in drug testing program.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 May 2009
Electrical › Electric Supply System (service) › Cable
Issued 30 September 2008
Resolved
Repair outer insulation on shore tie.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 4 May 2009
Communications › Radio Communications › EPIRB
Issued 30 September 2008
Resolved
Provide current EPIRB battery & hydrostatic release. Vessel restricted to operation within 3NM of shore until EPIRB deficiencies corrected.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 4 May 2009
Navigation › Piloting/Steering › Marine Charts
Issued 30 September 2008
Resolved
Provide up-to-date charts and Coast Pilot for area of operation.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 4 May 2009
Personnel › Training › First Aid/CPR
Issued 30 September 2008
Resolved
Provide proof of current first aid certification for 50% of crew.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 4 May 2009
Electrical › Lighting (emergency) › Lighting Branch Circuit
Issued 30 September 2008
Resolved
Prove proper operation of emergency lighting in lower accommodation space.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 4 May 2009
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 30 September 2008
Resolved
Prove proper operation of stern light. Vessel restricted to daytime operations until in compliance.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 4 May 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 30 September 2008
Resolved
Ensure first aid kit contents are complete and up-to-date (inspector noted missing eye patch kit, ammonia inhalants, iodine applicators)
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 4 May 2009
Lifesaving › Lifebuoys › Serviceable
Issued 30 September 2008
Resolved
Remove unserviceable lifering (forward, starboard side). Replacement not required as ring is in excess of requirements.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 4 May 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 30 September 2008
Resolved
Post all three pages of Certificate of Inspection.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 4 May 2009
Engineering › Bilge Water Management System › Pump
Issued 30 September 2008
Resolved
Label bilge pump indicating lights on control panel to show which light corresponds to the pump in which space.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 11 May 2009
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 30 September 2008
Resolved
Replace lagging on port-side exhaust of starboard engine.
Action required: 705 - Other - as specified
Due 5 January 2009
Resolved 4 May 2009
Electrical › Electrical Distribution System (service) › Wiring
Issued 3 October 2007
Resolved
Remove dead-end wire inside galley vent hood. (Or replace missing light.)
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 17 October 2007
Engineering › Diesel Engine (propulsion-reduction gear) › Gear/Clutch Starter (electric)
Issued 3 October 2007
Resolved
Demonstrate proper operation of starboard engine.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2007
Resolved 17 October 2007
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 3 October 2007
Resolved
Prove enrollment of all crew in drug testing program.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 17 October 2007
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 3 October 2007
Resolved
Provide DOT approved alcohol test kits for all crewmembers.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 17 October 2007
Operations/Management › Drills/Instruction › Not Conducted
Issued 3 October 2007
Resolved
Conduct drills (man overboard, fire, abandon ship) with crew.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 17 October 2007
Navigation › Piloting/Steering › Coast Guard Light List
Issued 3 October 2007
Resolved
Provide valid and current Light List, Coast Pilot & Tidal Currents (or print-outs of applicable sections).
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 17 October 2007
Communications › Radio Communications › EPIRB
Issued 3 October 2007
Resolved
Provide up-to-date EPIRB NOAA registration.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2007
Resolved 17 October 2007
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 3 October 2007
Resolved
Replace expired hydrostaic release on liferaft.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2007
Resolved 17 October 2007
Resolution: Vsl rep miss-marked existing hydro. Provided receipt from company showing new purchase.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 3 October 2007
Resolved
Renew markings on ring lifebuoys.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 17 October 2007
Fire Fighting › Fixed Halon Fire Extinguishing System › Operating Controls
Issued 3 October 2007
Resolved
Demonstrate operational test of fire-boy engine shut down & override. (Could not perform test during annual exam due to inability to start starboard engine.)
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2007
Resolved 17 October 2007
Documentation › Certificates/Documents › Certificate of Inspection
Issued 3 October 2007
Resolved
Post valid COI on board vessel (and get endorsement for annual from Marine Inspector).
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 October 2007
Resolved 17 October 2007
Engineering › Bilge Water Management System › Pump
Issued 3 October 2007
Resolved
Repair/replace rule pump in forward compartment (must be UL approved).
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 17 October 2007
Operations/Management › Bilge/Bilge System Management › Control of Oil Mixtures
Issued 3 October 2007
Resolved
Remove oil from engine room bilge (just inside engine room door).
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 17 October 2007
Documentation › Markings/Placards › Warning Signs
Issued 3 October 2007
Resolved
Mark emergency escape in passageway outside cabin containing secondary escape hatch.
Action required: 705 - Other - as specified
Due 17 October 2007
Resolved 17 October 2007
Communications › Radio Communications › EPIRB
Issued 31 May 2006
Resolved
Vessel to provide a valid hydrostatic release for EPIRB. EPIRB is then to be mounted in a float free position to the satisfaction of the attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 29 June 2006
Resolution: EPIRB Hydrostatic release installed and EPIRB mounted in a float free position, sat.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 31 May 2006
Resolved
Vessel to provide proof of enrollment in a random drug testing program for all employees on vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 29 June 2006
Resolution: Vsl operator provided proof of enrollment from consortium and list of employees, sat.
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 31 May 2006
Resolved
Vessel to provide properly spaces rail courses or equivalent on bow of vessel prior to allowing any passengers access to this part of the vessel.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 29 June 2006
Resolution: Operator installed wire fencing to meet railcourse requirements on bow of vessel, sat.
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 31 May 2006
Resolved
Vessel to provide a properly serviced portable fire extinguisher or receipt for purchase of a new extinguisher for operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 29 June 2006
Resolution: Operator purchased and installed new extinguisher and was able to provide receipt, sat.
Navigation › Piloting/Steering › US Coast Pilot
Issued 31 May 2006
Resolved
Vessel to provide current Coast Pilot for Operating area.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 29 June 2006
Resolution: Operator purchased a new Coast Pilot for operating area, sat.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 31 May 2006
Resolved
Vessel to provide updated Light List for operating area.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 29 June 2006
Resolution: Operator printed out the current light list and maintains on board, sat.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 31 May 2006
Resolved
Vessel to replace broken glass on door starboard side near the operating station.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 29 June 2006
Resolution: Broken window was removed and replaced, sat.
Electrical › Lighting (service) › Switch
Issued 31 May 2006
Resolved
Vessel to install covers on all lights throughout vessel, numerous covers were found missing in passenger staterooms and in the main deck accommodation spaces.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 29 June 2006
Resolution: Operator replaced/installed light covers as needed, sat.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 31 May 2006
Resolved
Vessel to provide a current training logbook with entries detailing requirements in 46 CFR 185.420, 185.520 and 185.524 for current crew.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 29 June 2006
Resolution: Operator purchased a new log book and now maintains it on board, sat.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 31 May 2006
Resolved
Replace battery in waterlight, battery to have expiration date or operator to provide receipt of purchase prior to night time operations. Additionally, verify that lifebuoy lifeline is properly stored and not in disarray as observed during 31 May.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 29 June 2006
Resolution: Waterlight battery was replaced, sat. Lifebuoy lifeline organized and stored appropriately, sat.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 31 May 2006
Resolved
Vessel is to complete full underway operational test, to include crew drills, testing of all machinery, and testing of ground tackle.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 29 June 2006
Resolution: Completed underway man overboard, fire and abandon ship drills, sat. Discussed with crew liferaft launching procedures, sat. Witnessed sat underway operation of steering and both MDE''s.
Accommodation/Occupational Safety › Sleeping Accommodations › Berth
Issued 31 May 2006
Resolved
Vessel to provide approved smoke detectors in all overnight accommodation spaces, numerous staterooms below deck and all overnight accommodation spaces on main deck were missing required detectors.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 29 June 2006
Resolution: Smoke detectors installed as required, sat.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 31 May 2006
Resolved
Vessel to mark upper deck for maximum number of passengers.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 29 June 2006
Resolution: Upper deck marked for 15 passengers, sat. Measured lenght of rail and determined suitable space for 25 passengers. O/O opted to keep at 15.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 31 May 2006
Resolved
Vessel to prove proper operation of all emergency lighting in below deck accommodations spaces as required by 46 CFR 184.432.
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 June 2006
Resolved 29 June 2006
Resolution: Operator demonstrated proper operation of emergency lighting in below deck accommodations, sat.
Lifesaving › Lifejacket/PFD (General) › Marking
Issued 31 May 2006
Resolved
Vessel to permanently label life jacket storage for number of life jackets onboard.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 29 June 2006
Resolution: Life jacket storage labeled properly, sat.
Personnel › Certificates/Documents/Licenses › License, Operator
Issued 31 May 2006
Resolved
Vessel operator to provide proof of a valid FCC marine radio operator permit.
Action required: 705 - Other - as specified
Due 30 June 2006
Resolved 29 June 2006
Resolution: Operator obtained valid FCC marine radio operator permit and posted, sat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 19 May 2006
Resolved
Repair S/W leak on stbd exhaust in lazzarette.
Due 31 May 2006
Resolved 31 May 2006
Resolution: Clamp was tightened to repair the leak.
Construction/Loadline › Hull › Bracket
Issued 19 May 2006
Resolved
Repair loose swim step on transom.
Due 31 May 2006
Resolved 31 May 2006
Resolution: Loose bolt had been tightened.
Engineering › Shafting/Propeller Arrangements › Stern Gland
Issued 19 May 2006
Resolved
Properly align stbd shaft stuffing box (binding @1200 position)
Due 31 May 2006
Resolved 31 May 2006
Resolution: Shafting was properly aligned.
Engineering › Bilge Water Management System › Hose
Issued 19 May 2006
Resolved
Install missing hose clamp for bilge suction fwd E/R.
Due 31 May 2006
Resolved 31 May 2006
Resolution: Hose clamp was installed.
Engineering › Bilge Water Management System › Strainer
Issued 19 May 2006
Resolved
Clean all bilge suction strainers.
Due 31 May 2006
Resolved 31 May 2006
Resolution: Strainers were clean and not fouled with anything.
Construction/Loadline › Penetrations › Bottom Plug
Issued 28 May 2004
Resolved
Transducer block had damage. Needs to be sanded down smooth.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 June 2004
Resolved 29 May 2004
Resolution: Block was sanded down smooth as required. Sat.
Construction/Loadline › Hull › Hull Plating
Issued 28 May 2004
Resolved
Two bolt holes in aft port side of hull where bolts had been removed and not replaced. Seal holes with approved sealant or fiberglass.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 May 2004
Resolved 29 May 2004
Resolution: Holes were filled and fiberglassed. Sat.
Construction/Loadline › Hull › Side Shell
Issued 28 May 2004
Resolved
Signs of delamination on port side corner of transom in lazarette. Grind and lay down another layer of fiberglass.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 May 2004
Resolved 29 May 2004
Resolution: Area of delamination was ground down and a new layer of fiberglass was applied. Sat.
Construction/Loadline › Hull › Collision Strap
Issued 28 May 2004
Resolved
Bolt holes for starboard side aft rub rail are rusting thourgh. Replace bolts and properly seal.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 29 May 2004
Resolution: Bolts were replaced and sealed. Sat.
Construction/Loadline › Hull › Hull Plating
Issued 28 May 2004
Resolved
Trapped water in chip in fiberglass on port side of hull below the waterline. Grind down smooth, dry, and re-gel coat area.
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 May 2004
Resolved 29 May 2004
Resolution: Area was ground down and a new coat of gel-coat was applied. Sat.
Communications › Radio Communications
Issued 20 May 2003
Resolved
Complete EPIRB registration process and affix valid decal to EPIRB. LEGACY COMPONENT DESC: EPIRB
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 24 June 2003
Resolution: Found Satisfactory
Lifesaving › Lifejacket/PFD (Type I)
Issued 20 May 2003
Resolved
Provide 1 additional child life jacket bearing approval series 160.002, 160.005, or 160.055, for a total of 4 child life jackets. LEGACY COMPONENT DESC: Quantity
Action required: 705 - Other - as specified
Due 16 June 2003
Resolved 24 June 2003
Construction/Loadline › Hull
Issued 11 June 2002
Resolved
Effect repair to damaged port hull section approximately 10 to 18" above chine, 3' aft of ovbd fitting from sink. LEGACY COMPONENT DESC: Hull Plating
Condition: Damaged By Earlier Event
Due 11 July 2002
Resolved 22 July 2002
Construction/Loadline › Penetrations
Issued 11 June 2002
Resolved
Ensure that all hose in seawater lines below the load waterline are fitted with double hose clamps (where practicable).
Condition: Improper Installation
Due 11 July 2002
Resolved 22 July 2002
Documentation › Manuals/Policy Documentation
Issued 11 June 2002
Resolved
Amend heavy weather (emergency) instructions to include installation of the aft door coaming plate. LEGACY COMPONENT DESC: Emergency Instructions
Due 11 July 2002
Resolved 22 July 2002
Construction/Loadline › Penetrations
Issued 11 June 2002
Resolved
Provide dead covers for 6 port lights located below the main (weather) deck. (See definition in 46 CFR 175.400.)
Due 11 July 2002
Resolved 22 July 2002
Fire Fighting › Combustible Materials
Issued 11 June 2002
Resolved
Remove all combustable waste receptacles. LEGACY COMPONENT DESC: Furniture/Furnishings
Due 11 July 2002
Resolved 22 July 2002
Construction/Loadline
Issued 6 August 2001
Resolved
Relocate vents located in the cockpit inner periphery to a location outsidethe periphery IAW 46CFR171.145(a)(2). COI was surrendered until vents are relocated vice reduced route to protected/ partially protected waters. Vessel remains an "existing vessel" when the COI is returned.
Condition: Unknown
Due 17 May 2002
Resolved 11 June 2002
Resolution: Cockpit vents were not modified. Vessel operator opted, instead, to reduce the vessel route to Lakes, Bays, and Sounds, with the understanding that a Coastwise route could be reacquired once ventilation was satisfactorily modified.
Construction/Loadline
Issued 17 May 2000
Resolved
PROVIDE PERMANENT REPAIRS TO 3 INCH CRACK/FRACTURE OF GELCOAT ON STARBOARD AFT SIDESHELL 6 INCHES FORWARD OF STERN AND 4 INCHES ABOVE THE CHINE.
Condition: Unknown
Due 17 June 2000
Resolved 8 June 2000
Navigation
Issued 17 May 2000
Resolved
Provide up to date Tidal Current Tables for area of operations.
Condition: Unknown
Due 17 June 2000
Resolved 16 June 2000
Accommodation/Occupational Safety
Issued 17 May 2000
Resolved
INSTALL RAILS, BARS, SLATS BULWARKS, ETC... IN COMPLIANCE WITH 46CFR177.900.
Condition: Unknown
Due 17 June 2000
Resolved 16 June 2000
Lifesaving
Issued 17 May 2000
Resolved
PROVIDE VERIFICATION OF COMPLIANCE WITH ANNUAL DRUG TESTING PROGRAM AS INDICATED ON USCG ANNUAL DRUG TESTING AUDIT FORM.
Condition: Unknown
Due 17 June 2000
Resolved 16 June 2000
Fire Fighting
Issued 17 May 2000
Resolved
LABEL RELEASE KNOB LOCATION FOR ENGINE ROOM FIXED FIRE EXTINGUISHING SYSTEM.
Condition: Unknown
Due 17 June 2000
Resolved 16 June 2000
Fire Fighting
Issued 26 April 1999
Resolved
COMPLETE INSTALLATION AND FINAL APPROVAL OF FIXED FIREFIGHTING SYSTEM FOR ENGINE ROOM.
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Fire Fighting
Issued 26 April 1999
Resolved
PROVE PROPER SERVICING OF ALL FIRE EXTINGUISHERS.
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Documentation
Issued 26 April 1999
Resolved
OBTAIN AND POST STABILITY LETTER.
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Lifesaving
Issued 26 April 1999
Resolved
ENSURE ALL LIFEJACKET LOCATIONS, INCLUDING FORWARD HEAD LOCKER, ARE CONSPICUOUSLY MARKED.
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Engineering
Issued 26 April 1999
Resolved
MARK DIRECTIONAL ARROWS ON EMERGENCY FUEL SHUTOFF VALVE.
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Fire Fighting
Issued 26 April 1999
Resolved
MAKE BULKHEAD BETWEEN ENGINEROOM AND BELOW-DECK CORRIDOR AS VAPOR TIGHT AS PRACTICAL TO MINIMIZE LOSS OF FIXED FIRE EXTINGUISHING AGENT.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Construction/Loadline
Issued 26 April 1999
Resolved
REPLACE DAMAGED BILGE PUMP HOSE IN LAZARETTE.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Lifesaving
Issued 26 April 1999
Resolved
PROVIDE 8 ADD'L ADULT LIFEJACKETS AND 2 ADD'L CHILD LIFEJHACKETS.
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Fire Fighting
Issued 26 April 1999
Resolved
RELOCATE FIRE DETECTORS PER MANUFACTUREER'S RECOMMENDATION.
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Electrical
Issued 26 April 1999
Resolved
PROVE PROPER OPERATION OF EMERGENCY LIGHTING.
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Accommodation/Occupational Safety
Issued 26 April 1999
Resolved
GALLEY STOVE SEA RAILS NEED TO BE INSTALLED PER 46 CFR 184.220.
Condition: Unknown
Due 21 May 1999
Resolved 18 May 1999
Lifesaving
Issued 26 April 1999
Resolved
POST LIFEJACKET DONNING PLACARD.
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Lifesaving
Issued 26 April 1999
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Engineering
Issued 26 April 1999
Resolved
RE-TIGHTEN LOOSE FITTINGS IN GENSET FUEL TANK VENT TUBING, AND SECURE/SUPPORT VENTLINE WHERE IT ABUTTS OVERHEAD.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Fire Fighting
Issued 26 April 1999
Resolved
PROVIDE SMOKE DETECTORS MEETING "UL STANDARD 271 FOR RECREATIONAL VEHICLES"IN ALL OVERNIGHT ACCOMMODATION SPACES.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Navigation
Issued 26 April 1999
Resolved
MAKE CHART CORRECTIONS AND PROVIDE LIGHT LIST PER 46CFR 184.420.
Condition: Unknown
Due 21 May 1999
Resolved 25 May 1999
Accommodation/Occupational Safety
Issued 26 April 1999
Resolved
REPAIR SOFT PATCH IN FRESH WATER PIPE IN OVERHEAD JUST STARBOARD OF GENERATOR.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Engineering
Issued 26 April 1999
Resolved
PROVIDE SUPPORT FOR MAIN ENGINE EXHAUST PIPE SECTIONS, P&S, BETWEEN MUFFLERS AND STERN.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Construction/Loadline
Issued 26 April 1999
Resolved
REATTACH RETENTION CHAINS ON ALL WEATHERDECK WATERTIGHT HATCHES.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Engineering
Issued 26 April 1999
Resolved
REFIT FLEXIBLE JOINT ON PORT MAIN ENGINE EXHAUST PIPE, FORWARD OF MUFFLER, SO THAT DOUBLE HOSE CLAMPS ARE POSITIONED OVER PIPE/HOSE JOINT VICE JUST OVER HOSE.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Engineering
Issued 26 April 1999
Resolved
PROVIDE ADD'L SUPPORT FOR FUEL FILL HOSE TO GENERATOR TANK, ENSUREING THAT ENTIRE LENGTH OF HOSE SLOPES TOWARD TANK TO ALLOW COMPLETE DRAINAGE.
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Accommodation/Occupational Safety
Issued 26 April 1999
Resolved
ENSURE ALL WASTE RECEPTACLES ARE MADE OF NON-COMBUSTIBLE MATERIAL PER 46CFR177.405(F).
Condition: Unknown
Due 18 May 1999
Resolved 18 May 1999
Lifesaving
Issued 21 April 1998
Resolved
Properly log drills for lifesaving and monthly epirb test.
Condition: Unknown
Due 21 April 1998
Resolved 30 June 1998
Engineering
Issued 21 April 1998
Resolved
Properly repair or renew leaking wet exhaust on port MDE aft of engine roombulkhead in generator room.
Condition: Unknown
Due 21 May 1998
Resolved 30 June 1998
Fire Fighting
Issued 21 April 1998
Resolved
Provide three 2 1/2 gallon fire buckets which are marked for fire use only.
Condition: Unknown
Due 21 May 1998
Resolved 30 June 1998
Navigation
Issued 23 April 1997
Resolved
OBTAIN & MOUNT CAT-1 FCC APPROVED 406 MHZ EPIRB IN A FLOAT FREE ARRAINGEMENT. VESSEL RESTRICTED TO OPERATIONS INSIDE THREE MILES (MAY NOT OPERATE ON THE HIGH SEAS) UNTIL EPIRB ONBOARD.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Documentation
Issued 23 April 1997
Resolved
PROVIDE UPDATED EDITION (10/96) OF 46 CFR PARTS 166 TO 199.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Lifesaving
Issued 23 April 1997
Resolved
ADJUST GRIPES/HOLD DOWN STRAPS ON BOTH LIFERAFTS.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Documentation
Issued 23 April 1997
Resolved
CHANGE/UPDATE ADDRESS ON CERTIFICATE OF DOCUMENTATION.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Documentation
Issued 23 April 1997
Resolved
POST CERTIFICATE OF INSPECTION & RETAIN ORIGINAL ONBOARD.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Lifesaving
Issued 26 April 1996
Resolved
RE-STENCILE/MARK BOTH LIFE RING BUOYS WITH VESSEL'S NAME AND REPLACE RETRO TAPE AS NEEDED.
Condition: Unknown
Due 15 May 1996
Resolved 29 October 1996
Documentation
Issued 26 April 1996
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 May 1996
Resolved 29 October 1996
Engineering
Issued 26 April 1996
Resolved
CONNECT SEPARATED JOINT ON VENT LINE ON HEATER FUEL OIL TANK, TO VENT TANK TO OUTSIDE WEATHERDECK.
Condition: Unknown
Due 15 May 1996
Resolved 29 October 1996
Lifesaving
Issued 26 April 1996
Resolved
RING BUOY LIGHT NOT WORKING, REPAIR/REPLACE BATTERY AS APPROPRIATE.
Condition: Unknown
Due 15 May 1996
Resolved 29 October 1996
Lifesaving
Issued 18 April 1996
Resolved
MARK THE NAME OF VESSEL AND NUMBER OF PERSONS ON BUOYANT APPARATUS AS PER 46 CFR 185.30-5.
Condition: Unknown
Due 19 April 1996
Resolved 1 May 1996
Lifesaving
Issued 18 April 1996
Resolved
TEMP CHANGE IN LIFESAVING EQUIP. UNTIL THE INFLATABLE RAFTS ARE RETURNED FROM SERVICING & INSTALLED ABOARD, THE PASSENGERS AND CREW IS REDUCED TO A TOTAL OF 44 PERSONS AND THE ROUTE IS RESTRICTED TO LAKES, BAYS AND SOUNDS. THE HOURS OF OPERATION WILL DETERMINE NUMBER OF CREW REQUIRED.
Condition: Unknown
Due 30 April 1996
Resolved 1 May 1996
Engineering
Issued 24 November 1993
Resolved
CORRECT ENGINE ROOM SUPPLY & EXHAUST VENTING, ARRAINGE FOR EXHAUST TO VENT THE LOWER THIRD OF ENG RM BILGES._x001C_
Condition: Unknown
Due 15 June 1994
Resolved 16 September 1994
Lifesaving
Issued 24 November 1993
Resolved
PROVIDE 9 ADDITIONAL ADULT PFD'S REJECTED DURING COI EXAM. VSL RESTRICTED TO 44 TOTAL PERSONS UNTIL SUFFIENT NUMBER OF JACKETS ARE ONBOARD.
Condition: Unknown
Due 15 June 1994
Resolved 16 September 1994
Construction/Loadline
Issued 24 November 1993
Resolved
MARK HULL WITH LOADING MARKS.
Condition: Unknown
Due 15 June 1994
Resolved 16 September 1994
Electrical
Issued 24 November 1993
Resolved
REMOVE OR MAKE-UP & PROPERLY DEAD END GUAGE WIRING IN ENG RM._x001C_
Condition: Unknown
Due 15 June 1994
Resolved 16 September 1994
Engineering
Issued 24 November 1993
Resolved
PROVIDE/INSTALL GUARD OVER STBD ENGINE BELTS.
Condition: Unknown
Due 16 September 1994
Resolved 16 September 1994
Electrical
Issued 24 November 1993
Resolved
PROPERLY BLOCK ALL BATTERIES IN PLACE IN BOTH ENG RM & MSD SPACE. PROVIDE COVER FOR BATTERY BOX IN MSD SPACE.
Condition: Unknown
Due 15 June 1994
Resolved 16 September 1994
Engineering
Issued 24 November 1993
Resolved
PROVIDE/INSTALL FLAME CUP AROUND F/O EMERGENCY SHUT OFF REACH ROD FOR FURNANCE.
Condition: Unknown
Due 15 June 1994
Resolved 16 September 1994
Engineering
Issued 24 November 1993
Resolved
REPAIR/REPLACE LUBE OIL AND REVERSE GEAR SENDING UNITS - MAKE GUAGES WORK AT STEERING STATION.
Condition: Unknown
Due 15 June 1994
Resolved 16 September 1994
Engineering
Issued 24 November 1993
Resolved
REPLACE ENG THROTTLE & GEAR SHIFT CONNECTORS WITH STANDARD CONTROL CABLE FITTINGS OR DOUBLE NUT/DRILL & PIN CONNECTIONS ON BOTH ENGINES.
Condition: Unknown
Due 15 June 1994
Resolved 16 September 1994
Engineering
Issued 24 November 1993
Resolved
LAG EXHAUST MANIFOLD PIPES, BOTH ENGINES BETWEEN EXHAUST MANIFOLD AND WATERINJECTION CONNECTION TO EXHAUST PIPE.
Condition: Unknown
Due 15 June 1994
Resolved 16 September 1994
Fire Fighting
Issued 24 November 1993
Resolved
PROVIDE/MOUNT ADDITIONAL B-II FIRE EXT IN UPPER PASS LOUNGE AREA_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 July 1994
Resolved 16 September 1994
Navigation
Issued 24 November 1993
Resolved
PROVIDE DEVATION CARD FOR SHIPS COMPASS._x001C_
Condition: Unknown
Due 15 June 1994
Resolved 16 September 1994
Construction/Loadline
Issued 31 August 1990
Resolved
REPLACE BROKEN GLASS IN AFTER DOOR TO DECK HOUSE.
Condition: Unknown
Due 31 August 1990
Resolved 31 August 1990
Construction/Loadline
Issued 22 July 1989
Resolved
DRYDOCK THE VESSEL AND MAKE PERMANENT REPAIRS TO THE KEEL, WHERE THE FIBER-GLASS WAS TORN LOOSE DUE TO GROUNDING.
Condition: Unknown
Due 22 July 1989
Resolved 22 July 1989
Accommodation/Occupational Safety
Issued 6 May 1988
Resolved
BRING INTO COMPLIANCE THE MSD'S WITH CG APPROVED UNITS.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Construction/Loadline
Issued 6 May 1988
Resolved
ATTACH AND AFFIX DRAIN HOSE FOR LAZARETT COVER FOR WATER RUNOFF
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Accommodation/Occupational Safety
Issued 6 May 1988
Resolved
REPLACE IN KIND, THE PEDESTAL FOR THE FORWARD MIDDLE LIFERAIL STANTION ON UPPER DECK.
Condition: Unknown
Due 6 May 1988
Resolved 6 May 1988
Unknown
Issued 8 April 1986
Resolved
Unknown Component - Unknown Cause/Condition
Condition: Unknown
Due 8 April 1986
Resolved 8 April 1986