Records from 1985 to 2026. Most recent: inspection, 8 April 2026.
Inspection history · 93
8 April 2026
Administrative Inspection · Vessel Attendance · Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8312954
27 January 2026
Vessel Attendance · Drydock Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8279813
15 October 2025
Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8253563
11 March 2025
Deficiency Check · Internal Structural Exam · Annual Inspection · Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8092132
16 November 2024
Administrative Inspection · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8032081
25 March 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7884869
6 December 2023
Drydock Exam · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7834670
16 November 2023
Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7830729
7 September 2023
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7789398
9 May 2023
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7685447
21 April 2023
Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 7673857
7 March 2023
Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7647250
19 December 2022
Deficiency Check · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7611035
14 October 2022
In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7577290
17 March 2022
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7413747
11 February 2022
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7394789
25 January 2022
Type not recorded
No type recorded · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7391076
13 January 2022
Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7346281
18 October 2021
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7334730
5 May 2021
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7190257
13 April 2021
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7174291
9 April 2020
Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6937397
15 January 2020
Deficiency Check · Drydock Exam · Hull Examination · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6889869
7 October 2019
Deficiency Check · In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6829790
8 April 2019
Internal Structural Exam · Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6658286
29 March 2018
COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6381232
27 November 2017
Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6313929
20 July 2017
Deficiency Check · Administrative Inspection · Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6220198
10 April 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6121514
3 April 2017
Hull Examination · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6098402
19 May 2016
Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5880413
4 November 2015
Administrative Inspection
Administrative · Sector North Carolina · USCG East District (CGD-E) · Activity 5760956
22 September 2015
Construction Oversight · Plan Review "T" Boat · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5826505
27 August 2014
Damage Survey
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4973564
11 August 2014
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4951772
15 May 2014
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4859671
7 May 2014
Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4854524
1 September 2010
Administrative Inspection
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3742989
22 April 2009
Internal Structural Exam · Hull Examination · Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3457769
25 March 2009
Drydock Extension
Administrative · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3440199
22 August 2008
Examination of Repairs · Damage Survey
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3311923
8 August 2008
Type not recorded
No type recorded · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3312135
17 July 2008
In-Service Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3270967
12 May 2008
Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 3204341
29 March 2008
Type not recorded
No type recorded · Sector Charleston · USCG Southeast District (CGD-SE) · Activity 3173822
17 April 2007
Hull Examination · COI Inspection
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2893333
3 April 2006
Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2615195
22 March 2006
MARPOL Annex V Examination · Annual Inspection
Physical examination · Sector New York · USCG Northeast District (CGD-NE) · Activity 2607290
9 February 2005
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2289159
31 March 2004
Internal Structural Exam · Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2033482
24 March 2004
MARPOL Annex V Examination · Deficiency Check · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 2030202
10 June 2002
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1628594
8 April 2002
MARPOL Annex V Examination · Annual Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1602451
1 March 2002
Hull Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1490516
15 August 2001
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1069173
6 February 2001
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1361975
17 February 2000
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1397350
12 January 2000
Deficiency Check · Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1467181
20 January 1999
Re-Inspection · MARPOL Annex V Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1372487
26 February 1998
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 781160
28 January 1998
Hull Examination
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 782417
21 January 1998
Re-Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1456550
22 January 1997
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1102606
6 October 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 128681
30 April 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1081277
3 April 1996
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1079717
20 February 1996
Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1192266
31 January 1996
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1182746
29 January 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 222305
29 January 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 649461
22 January 1996
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186893
16 January 1996
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1425678
24 April 1995
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 869232
21 February 1995
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1135227
22 July 1994
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 64262
25 April 1994
MARPOL Annex V Examination · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1169884
3 May 1993
Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 833271
14 December 1992
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1142822
24 April 1992
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1263789
11 June 1991
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 935511
15 April 1991
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1247051
16 July 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 908222
9 April 1990
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 900305
29 January 1990
Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1232847
30 November 1989
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1216558
13 April 1989
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1196752
27 July 1988
Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1041808
18 April 1988
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1033024
22 April 1987
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1008171
24 March 1987
Hull Examination
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1017230
21 April 1986
COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1308949
26 March 1986
Credit Drydock
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1304501
3 July 1985
Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 980589
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 8 April 2026
Resolved
On a vessel of at least 26 ft. in length, a visual and audible alarm must be provided at the operation station to indicate a high water level in a machinery space bilge. Audible bilge alarm would not activate at the operating station.
46 CFR 182.530(a)(2)
Condition: Damaged By Earlier Event
Action required: 10 - Deficiency Rectified
Due 8 April 2026
Resolved 8 April 2026
Resolution: Replaced
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 8 April 2026
Resolved
Each survival craft must be secured to the vessel by a painter with a float-free link permanently attached to the vessel except that a float free link is not required if the vessel operates only on waters not as deep as the length of the painter. Float free link was found not permanently attached to the vessel. Vessel maintains an Oceans Route.
46 CFR 180.130(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 April 2026
Resolved 8 April 2026
Resolution: Reattached
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 8 April 2026
Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Floating waterlight was found inoperable.
46 CFR 180.175(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 8 April 2026
Resolved 8 April 2026
Resolution: Replaced
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2026
Resolved
he discharge ends of fuel tank vent pipes must be fitted with removable flame screens or flame arresters. Flame screen was missing from STBD fuel vent.
46 CFR 182.20-35(d)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 April 2026
Resolved 8 April 2026
Resolution: Replaced
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 15 October 2025
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Vessel's GARMIN Chart system is not up to date with latest changes.
46 CFR 184.420(a)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 November 2025
Resolved 28 October 2025
Resolution: Received satisfactory photos of updated charts
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 15 April 2025
Resolved
All vessels shall be provided with a satisfactory arrangement for draining any watertight compartment. Bilge was not getting suction in 3 out of the 4 compartments tested. Rectify to satisfaction of attending marine inspector prior to carrying passengers.
46 CFR 182.25-1(a)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2025
Resolution: Bilge pump suction is operational; test sat.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 15 April 2025
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60
pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. The gauge on the fire pump showed 40 pounds per square inch. Rectify to the satisfaction of the attending marine inspector.
46 CFR 181.10-1(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 April 2025
Resolved 17 April 2025
Resolution: Fire pump discharge gauge replaced; test sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 16 May 2024
Resolved
All electrical equipment and circuits must be clearly
marked and identified. Galley panel breaker #7 was not
labled.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2024
Resolution: Label was added
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 15 May 2024
Resolved
All vessels must have navigation lights that are in compliance with the applicable sections of the international and Inland Navigation Rules, except that a vessel of more than 65 ft. in length must also have navigation lights that meet UL 1104. Vessels masthead light was broke prior to arrival. Rectify deficiencies to the satisfaction of the attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2024
Resolution: Replaced bulb. All sat.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2024
Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 PSI at the pump outlet. The pump outlet shall be fitted with a pressure gauge. The #1 fire pump pressure gauge was inoperable. Rectify deficiencies to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2024
Resolution: Replaced pressure gauge with new, tested, all sat.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 15 May 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to minimize accidental personnel contact with energized parts. Fire pump wires were not properly seated in stuffing tube.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2024
Resolution: Properly seated wires in stuffing tube
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 15 May 2024
Resolved
Requirements for the design, construction, installation, and operation of electrical equipment and systems including power sources, lighting, motors, miscellaneous equipment, and safety systems complying with ABYC where applicable. Main engine battery post cannot exceed 04 terminals per post. The vessel has exceeded the number allowed by ABYC standards. Rectify to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 June 2024
Resolved 3 October 2024
Resolution: Received photo of corrected battery terminals.
04 - Emergency Systems › N/A - No Subsystem › Functionality of Safety Systems
Issued 15 May 2024
Resolved
A station bill must be posted by the master on a vessel of more than 65 ft in length having a Certificate of Inspection requiring more than four crew members at any on time, including the master. Posted station bill did not comply with the requirements of the COI.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 3 October 2024
Resolution: Received photo of station bill corrected.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 15 May 2024
Resolved
A vessel of more than 65 ft in length must have at least one fire Axe located in or adjacent to the primary operating station.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2024
Resolution: Fire axe was mounted near the operating station
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 15 May 2024
Resolved
In addition to meeting 180.130 each life float must be stowed as required under this section, be of proper strength for the size of the life float as indicated on its identification tag. The STBD 25 man life float did not have a identification tag. Rectify to the satisfaction of the attending marine inspector.
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 22 May 2024
Resolution: Identification tag was added to life float
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 September 2023
Resolved
On vessels described by 46 CFR 175.110(d) of this chapter, a passenger safety bill must be posted by the master in each cabin or stateroom, and in passenger accommodation spaces. Vessel did not have a passenger safety bill. Create and post the passenger safety bill to the satisfaction of the attending Coast Guard Marine Inspector.
46 CFR 185.515
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 January 2024
Resolution: Passenger safety bill has been created and posted
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 6 April 2023
Resolved
Each life float must be individually attached to the painter by a line meeting § 180.175(f)(3) (ii), (iii), and (iv) and long enough that each life float can float without contacting any other life float or buoyant apparatus in the group. Life floats were connected in a series. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
Resolution: Vessel attached each LF to the painter individually.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 6 April 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Repair to the satisfaction of the attending Marine Inspector.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
Resolution: Replaced light cover
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 6 April 2023
Resolved
Masthead light means a white light placed over the fore and aft centerline of the vessel showing an unbroken light over an arc of the horizon of 225 degrees. Masthead light was not displaying the full 225 degrees as required. Repair to the satisfaction of the attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
Resolution: Repaired light
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2023
Resolved
On a vessel on which the number of passengers permitted on upper decks is limited by stability criteria, as indicated by the vessel's stability letter, the maximum number of passengers allowed on an upper deck must be indicated by a durable marking of at least 1 inch numbers and letters at the entranceway to that deck. Vessel did not have max passengers to the upper deck marked. Repair to the satisfaction of the attending Marine Inspector.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
Resolution: Has max passengers displayed for upperdeck.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 7 March 2023
Resolved
Each EAP education program must include at least the following elements: display and distribution of informational material; display and distribution of a community service hot-line telephone number for crewmember assistance, and display and distribution of the employer's policy regarding drug and alcohol use in the workplace. Vessel did not have displayed the required information. Repair to the satisfaction of the attending Marine Inspector
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 27 April 2023
Resolution: Posted numbers
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 23 December 2022
Resolved
An interconnected detection and alarm system must alarm on low power. Vessels system does not alarm on low power. Repair to the satisfaction of the attending Marine Inspector. 46 CFR 181.450(a)(4)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 23 December 2022
Resolved 25 January 2023
Resolution: Tested satisfactorily with attending MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 October 2022
Resolved
Each life preserver carried on a vessel engaged in ocean, coastwise or Great Lakes service after June 30, 1980, must have a personal floatation device light that is approved under subpart 161.012 of this chapter. Vessel was found to have 12 PFD's with lights that did not work.
46 CFR 180.25-20 (a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 October 2022
Resolution: Vessel rep. replaced the lights with lights in storage while MI was on board.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 October 2022
Resolved
Equipment of life floats/ Water Light, the water light must be of an approved automatic electric type. 01 of 04 life float lights were not working when tested. Vessel is required to replace batteries or light and re-install to working order.
46 CFR 180.15-5(d)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Resolved 18 October 2022
Resolution: Batteries were replaced while MI was on board.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 October 2022
Resolved
Life Floats Marking/ A substantial nameplate must be permanently attached to each buoyant apparatus. The nameplate must contain the name of the manufacturer, lot designation or serial number, approval number, dimensions, and number of person capacity. 46 CFR 160.027-2(a) sends life floats to buoyant apparatus regs. Vessels 25 man life float is missing nameplate and serial number markings. Vessel will replace this life float by renewal of COI on 10 April 2023.
46 CFR 160.010-8
Condition: Invalid
Action required: 705 - Other - as specified
Due 10 April 2023
Resolved 17 May 2024
Resolution: Vessel still has not provided a nameplate but the deficiency is now created in activity # 7884869
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 26 April 2022
Resolved
Water for cooling the exhuast pipe, other than a vertical exhuast pipe, must be injected into the exhuast system as near to the engine manifold as practicable. The water must pass through the entire length of the exhuast pipe. Port side MDE exhuast pipe is leaking water in engine space near the flexible and permanent pipe junction. Repair to the satisfaction of the USCG Marine Inspector.
46CFR182.425 (b)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2022
Resolved 9 May 2022
Resolution: Recieved video of MDE in operation showing leak had been properly repaired.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2021
Resolved
...Additional control equipment and measuring instruments shall be provided as necessary to insure satisfactory operation of the generator or generators. Vessels main distribution panel interlock device will allow breakers for both the ships service generators and shore power to all be in the closed position simultaneously.
46 CFR 183.10(g)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 April 2021
Resolved 20 April 2021
Resolution: Repaired to the satisfaction of the attending MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 20 April 2021
Resolved
Suitable covers, guards, or rails shall be installed in way of the exposed and hazardous places such as gears, machinery, etc. Both main propulsion engines have no guards of covers around flywheels. Guards or covers shall be installed in accordance with 46 CFR 58.01-20
46 CFR 177.35-15
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 20 May 2021
Resolved 5 May 2021
Resolution: Installed flat stock to prevent exposed machinery hazard.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 20 April 2021
Resolved
All vessels shall be provided with an approved adult life perserver for each person carried. 04 life perservers were missing 200cm tape in accordance with 46 CFR 160. Restricted to 91 PAX.
46 CFR 180.25-5
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 May 2021
Resolved 5 May 2021
Resolution: Vessel purchased 04 new life preservers.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 20 April 2021
Resolved
All vessels shall be provided with not less than two avenues of escape from all general areas accessible to passengers or where the crew may be quartered or normally employed. The starboard engine room escape scuttle siezed rendering the escape hatch inoperable.
46 CFR 177.15(a)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 April 2021
Resolved 20 April 2021
Resolution: Scuttle opened and working as designed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 20 April 2021
Resolved
When the flexible section of a fuel oil tank fill pipe is a nonconductor of electricity, the metallic sections of the filling pipe seperated thereby, shall be joined by a conductor for protection against static spark when filling. The grounding wire on the port flexible fuel oil tank fill pipe was found disconnected.
46 CFR 182.20-30(d)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 April 2021
Resolved 20 April 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 October 2019
Resolved
All emergency exits used as a means of escape must be marked on both sides in clearly legible letters at least 2 inches high "EMERGENCY EXIT. KEEP CLEAR." Vessel must label emergency exit on main cabin door.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 October 2019
Resolved 17 October 2019
Resolution: Vessel provided photos of applied emergency exit markings.
Engineering › Shafting/Propeller Arrangements › Shaft Cone
Issued 20 July 2017
Resolved
Received report from owner of loss of starboard propeller. Vessel is to haul out and determine extent of damage and repair vessel to the satisfaction of attending marine inspector and prior to the carriage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 2 August 2017
Resolution: Vessel has shafts and propellers properly installed.
Engineering › Shafting/Propeller Arrangements › Shaft Cone
Issued 20 July 2017
Resolved
Vessel shall be hauled out of the water by 01 DEC 2017 for shafting repairs detailed in Inspections Letter 013-17, dated August 2017. Repairs shall be made to the satisfaction of attending marine inspector.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 1 December 2017
Resolved 18 January 2018
Resolution: Vessel was hauled out by 01DEC17 and shafts were replaced according to approved plans.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 18 April 2017
Resolved
90 Adult Lifejackets stored onboard. COI certificated for 101 adult lifejackts. The vessel must be equipped with an adult size lifejacket for each person authorized. Reduce persons count to 88 persons onboard.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 20 April 2017
Resolution: Vessel rep provided 11 additional lifejackets with correct stowage.
Construction/Loadline › Hull › Stiffener
Issued 8 May 2014
Resolved
Gauge and weld fractured weld in fore peak, stbd overhead.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 14 May 2014
Resolution: Weld repaired in fore peak.
Construction/Loadline › Hull › Longitudinal Frame
Issued 8 May 2014
Resolved
Weld longitudinal frames 5th up from keel on stbd side.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 June 2014
Resolved 14 May 2014
Resolution: Longitudinal frame welded.
Operations/Management › Drug and Alcohol Testing › Testing, Equipment
Issued 19 May 2009
Resolved
Replace the expired alcohol testing devices.
Due 2 June 2009
Resolved 26 May 2009
Communications › Radio Communications › Radiotelephone Transceiver (2-4 MHz)
Issued 19 May 2009
Resolved
Repair or replace the inoperative single side band radio; the vessel is restricted to within 20 miles from land until corrected.
Due 18 June 2009
Resolved 22 May 2009
Communications › Alarms/Indicators › Bilge Alarm
Issued 19 May 2009
Resolved
Repair the inoperative bilge alarm panel in the wheelhouse.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 19 May 2009
Resolved
Provide proof of FCC Radio Operator Permit for the vessel Master.
Due 18 June 2009
Resolved 26 May 2010
Communications › Audible Communications › Bell
Issued 19 May 2009
Resolved
Provide the vessel with an 11.8 inch bell as per the Navigation Rules.
Due 18 June 2009
Resolved 22 May 2009
Communications › Radio Communications › EPIRB
Issued 19 May 2009
Resolved
Replace the expired battery for the EPIRB; vessel is restricted to within three miles from land until corrected.
Action required: 705 - Other - as specified
Resolved 22 May 2009
Communications › Radio Communications › EPIRB
Issued 19 May 2009
Resolved
Replace the expired hydrostatic release for the EPIRB; the vessel is restricted to within three miles of land until corrected.
Action required: 705 - Other - as specified
Resolved 22 May 2009
Communications › Radio Communications › EPIRB
Issued 19 May 2009
Resolved
Replace the deteriorated antenna for the EPRIB; the vessel is restricted to with three miles of land until corrected.
Action required: 705 - Other - as specified
Resolved 22 May 2009
Lifesaving › Lifefloat › Painter
Issued 19 May 2009
Resolved
Properly attach the sea painter to the life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 19 May 2009
Resolved
Properly attach the water light to the life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Lifesaving › Lifefloat › Lifeline
Issued 19 May 2009
Resolved
Renew the life lines and the man basket retaining line on one of the life floats.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Lifesaving › Lifefloat › Paddle
Issued 19 May 2009
Resolved
Stencil the life float paddles with the vessel name as needed.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 19 May 2009
Resolved
Renew the life lines on the ring buoys or replace the ring buoys.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Lifesaving › Lifebuoys › Serviceable
Issued 19 May 2009
Resolved
Repair to like new condition or replace the ring buoys as needed; one has a hole and another has a loose inner seal.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 19 May 2009
Resolved
Provide the vessel with a USCG approved first aid kit IAW 46 CFR 160.041.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2009
Documentation › Markings/Placards › Garbage Placard
Issued 19 May 2009
Resolved
Provide the vessel with the required garbage placard.
Due 18 June 2009
Resolved 22 May 2009
Engineering › Fuel Oil Storage/Transfer System › Manifold
Issued 19 May 2009
Resolved
Properly mark the fuel tank fills.
Due 18 June 2009
Resolved 22 May 2009
Documentation › Certificates/Documents › FCC SSL
Issued 22 August 2008
Resolved
Provide proof of Safety Radio Certificate.
Due 22 September 2008
Resolved 22 January 2009
Documentation › Certificates/Documents › Certificate of Inspection
Issued 17 July 2008
Resolved
Vessel failed to operate with the terms of it's COI in that they exceeded the max passenger capacity on the upper deck.
Action required: 17 - Rectify deficiencies prior to departure
Due 17 July 2008
Resolved 17 July 2008
Lifesaving › Buoyant Apparatus › Lifeline
Issued 12 May 2008
Resolved
lifeline for ring need a corrosion proof clip the detach line from ring.
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 19 May 2008
Resolution: placed quick clip on lifeline
Lifesaving › Lifefloat › Serviceable
Issued 12 May 2008
Resolved
remove or service 11 man lifefloat
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 19 May 2008
Resolution: removed 11 man life raft, not required (additional)
Documentation › Certificates/Documents › Certificate of Inspection
Issued 12 May 2008
Resolved
COI not posted
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 19 May 2008
Resolution: posted COI
Documentation › Manuals/Policy Documentation › Emergency Instructions
Issued 12 May 2008
Resolved
Post emergency instructions in passenger area
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 June 2008
Resolved 19 May 2008
Resolution: Emergency Instructions posted in passenger area
Engineering › Fuel Oil Service System › Filter
Issued 12 May 2008
Resolved
Place drip shields on racor filters
Condition: Improper Installation
Due 12 June 2008
Resolved 19 May 2008
Resolution: placed drip shields on racors
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 12 May 2008
Resolved
Place rotating machinery guards on front of both main diesel engines
Condition: Unknown
Due 12 June 2008
Resolved 19 May 2008
Resolution: guards placed on front of both MDEs
Stability › Weathertight Integrity › General
Issued 12 May 2008
Resolved
replace broken windown, port side on passenger deck
Condition: Damaged By Earlier Event
Due 12 June 2008
Resolved 19 May 2008
Resolution: window replaced
Documentation › Certificates/Documents › Stability Letter
Issued 12 May 2008
Resolved
Post stability letter on bridge
Condition: Unknown
Due 12 June 2008
Resolved 19 May 2008
Resolution: stability letter posted
Documentation › Certificates/Documents › FCC SSL
Issued 12 May 2008
Resolved
vessel needs FCC safety radio certificate
Condition: Unknown
Due 12 June 2008
Resolved 22 January 2009
Resolution: vessel has certificate
Communications › Radio Communications › VHF Radiotelephone
Issued 12 May 2008
Resolved
operators need FCC Marine Radio Operator Permits
Condition: Unknown
Due 12 June 2008
Resolved 19 May 2008
Resolution: operators have permits
Lifesaving › Lifefloat › Not on Board
Issued 17 April 2007
Resolved
Life floats were on board but not properly installed and ready for inspection. Operator required to properly install and configure Life floats to the satisfaction of Attending CG Marine Inspector prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2007
Resolution: Lifefloats properly installed and made ready for inspection.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 17 April 2007
Resolved
Vessel had 91 adult and 1 child sized lifejackets (kapok) that failed serviceability inspection. Operator required to replace all unserviceable lifejackets prior to carry passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 April 2007
Resolution: All unserviceable lifejackets replaced. Replacement jackets properly outfitted and stenciled and made ready for inspection.
Documentation › Logs/Records › Logbook (official)
Issued 17 April 2007
Resolved
Vessel did not posses official logbook.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 20 April 2007
Resolution: Offical logbook onboard and made ready for inspection.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 17 April 2007
Resolved
Port navigational running light inoperable. Replace light bulb.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 20 April 2007
Resolution: Port navigational running light bulb replaced and observed to be watching properly
Documentation › Markings/Placards › Capacity Marking
Issued 17 April 2007
Resolved
Upper Deck required to have passenger capacity posted in visible location.
Action required: 705 - Other - as specified
Due 30 April 2007
Resolved 30 April 2007
Resolution: Upper Deck capacity posted
Construction/Loadline › Hull › Weld
Issued 14 March 2007
Resolved
Repair unfinished welds in Beam in vicinity directly aft of Main Engine
Action required: 705 - Other - as specified
Due 29 March 2007
Resolved 21 March 2007
Resolution: Welds repaired and finished
Construction/Loadline › Hull › Weld
Issued 14 March 2007
Resolved
Repair unfinished welds in beam port side of Engine Room
Action required: 705 - Other - as specified
Due 29 March 2007
Resolved 21 March 2007
Resolution: Welds repaired and finished
Construction/Loadline › Hull › Weld
Issued 14 March 2007
Resolved
Broken weld in amidships lower frame in aft lazerette
Action required: 705 - Other - as specified
Due 29 March 2007
Resolved 21 March 2007
Resolution: Broken welds repaired
Lifesaving › Lifebuoys › Serviceable
Issued 22 March 2006
Resolved
Replace 01 lifering with new located on 2nd deck aft port side.
Due 22 April 2006
Resolved 24 April 2006
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 22 March 2006
Resolved
Install lagging for both generators up to water injection point.
Due 22 April 2006
Resolved 24 April 2006
Engineering › Sea-water System (primary cooling) › Piping
Issued 9 February 2005
Resolved
Raw water cooling piping for S/S generator made from PVC piping. Remove & replace with metallic piping.
Condition: Improper/Lack of Maintenance
Due 16 February 2005
Resolved 15 February 2005
Resolution: Installed metallic piping for raw water cooling system for P/S generator.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 9 February 2005
Resolved
Repair 3 inch gash on BA caused by wooden spacer with approved [name withheld] epoxy.
Condition: Improper/Lack of Maintenance
Due 16 February 2005
Resolved 15 February 2005
Resolution: Repaired 3" gash with approved epoxy.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 9 February 2005
Resolved
Replace 3 wasted lifejackets with new/approved in kind to reflect pax count on COI.
Condition: Improper/Lack of Maintenance
Due 16 February 2005
Resolved 15 February 2005
Resolution: Replaced 03 missing adult lifejackets.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 24 March 2004
Resolved
Display COI Amendments with COI.
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 25 March 2004
Resolution: DD/ISE is documented by MSFO Long Island, Activity# 1490516.
Documentation › Certificates/Documents
Issued 24 March 2004
Resolved
Post Current SPV decal
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 16 April 2004
Resolution: Decal posted.
Lifesaving › Buoyant Apparatus
Issued 24 March 2004
Resolved
Mark capacity on LF & BA.
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 16 April 2004
Resolution: Capacity marked on LF & BA.
Lifesaving › Buoyant Apparatus
Issued 24 March 2004
Resolved
Stowage of LF & BA needs to be float free (baggy ties).
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 16 April 2004
Resolution: Baggy ties are acceptable.
Lifesaving › Lifejacket/PFD (General)
Issued 24 March 2004
Resolved
Display donning placards for both types of life jackets
Due 9 April 2004
Resolved 16 April 2004
Resolution: Placards diplayed.
Electrical › Lighting (service)
Issued 24 March 2004
Resolved
Replace deck lights on upper deck as needed.
Action required: 705 - Other - as specified
Due 9 April 2004
Resolved 16 April 2004
Resolution: All deck lights operating.
Electrical › Electric Generation Source (service)
Issued 8 April 2002
Resolved
Clean both service generators to satisfaction of attending marine inspector. Repair cover on stbd generator. LEGACY COMPONENT DESC: Generator
Condition: Improper/Lack of Maintenance
Due 25 April 2002
Resolved 10 June 2002
Resolution: Cover repaired and both gen sets cleaned.
Electrical › Electrical Distribution System (service)
Issued 8 April 2002
Resolved
Prove proper operation of switchboard indicating lights. LEGACY COMPONENT DESC: Switchboard
Condition: Improper/Lack of Maintenance
Due 25 April 2002
Resolved 10 June 2002
Resolution: Switchboard power available lights operational.
Electrical › Lighting (service)
Issued 8 April 2002
Resolved
Repair/replace engine room electrical receptacle with approved type. LEGACY COMPONENT DESC: Outlet Box
Condition: Placed in Improper Service
Due 25 April 2002
Resolved 10 June 2002
Resolution: Approved receptacle installed.
Electrical
Issued 6 February 2001
Resolved
Replace broken / cracked wires throughout engine room
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Navigation
Issued 6 February 2001
Resolved
Paint both side shields flat black
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Construction/Loadline
Issued 6 February 2001
Resolved
Prove proper operation of bilge system prior to commercial operation
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Engineering
Issued 6 February 2001
Resolved
Replace leaking fuel line and clamp for generator
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Electrical
Issued 6 February 2001
Resolved
Replace broken wire for ground on generator, also other wires with cracked insulation
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Lifesaving
Issued 6 February 2001
Resolved
Replace two life buoys and ensure both have required retro tape and as appropriate properly attach lines
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Engineering
Issued 6 February 2001
Resolved
Clean and inspect fuel vents screens, replace if necessary
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Construction/Loadline
Issued 6 February 2001
Resolved
Correctly install bilge system cutout valve IAW 46CFR182.25(d)
Condition: Unknown
Due 18 February 2001
Resolved 18 February 2001
Lifesaving
Issued 6 February 2001
Resolved
Show proper installation of new 22 person Life Float. Until this requirement is cleared by an attending Marine Inspector, vsl is restricted to 72 total persons (passengers and crew) when operating in cold water morethan 3 miles from shore on a limited coast wise route.
Condition: Unknown
Due 6 February 2001
Resolved 6 February 2001
Navigation
Issued 17 February 2000
Resolved
MAKE PERMANENT AND PROPER REPAIRS TO RUDDER CONNECTING ARM, STBD SIDE.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Construction/Loadline
Issued 17 February 2000
Resolved
PROVE PROPER OPERATION OF BILGE HIGH LEVEL ALARMS.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Accommodation/Occupational Safety
Issued 17 February 2000
Resolved
REPLACE CRACKED WINDOW, PORT FWD PILOT HOUSE.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Lifesaving
Issued 17 February 2000
Resolved
MAKE PROPER REPAIRS TO BA FLOAT FREE SYSTEM SO THAT BA'S DO NOT BLOW OFF THE VESSEL.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Construction/Loadline
Issued 17 February 2000
Resolved
V/W ROUND STOCK, STBD SIDE FOREPEAK, #4 FROM KEEL, AS MARKED._x001C_
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Electrical
Issued 17 February 2000
Resolved
REPLACE POWER PANEL DOORS ON MAIN DECK AND IN ENGINE ROOM._x001C_
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Engineering
Issued 17 February 2000
Resolved
REPLACE RAW WATER HOSE ON PORT MAIN DIESEL ENGINE AT THE EXPANSION TANK.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Accommodation/Occupational Safety
Issued 17 February 2000
Resolved
MAKE PROPER REPAIRS TO ENGINE ROOM EMERGENCY ESCAPE SCUTTLE.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Electrical
Issued 17 February 2000
Resolved
REMOVE EXTENTION CORD AND PROVIDE PROPER HARDWIRE INSTALLATION AND CIRCUIT PROTECTION FOR GALLEY EQUIPMENT.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Fire Fighting
Issued 17 February 2000
Resolved
REPALCE FIRE MAIN DECK RISER SECTION OF PIPE, APPROX 6", ON THE PORT MAIN DECK.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Lifesaving
Issued 17 February 2000
Resolved
REPLACE PORT AFT LIFE RING.
Condition: Unknown
Due 28 February 2000
Resolved 28 February 2000
Navigation
Issued 12 January 2000
Resolved
REWELD CRACKED WELD ON STEERING GEAR SUPPORT, PORT SIDE, LAZ.
Condition: Unknown
Due 19 January 2000
Resolved 14 January 2000
Construction/Loadline
Issued 12 January 2000
Resolved
REWELD CRACKED WELD ON BIT SUPPORT, #1 CMPT.
Condition: Unknown
Due 19 January 2000
Resolved 14 January 2000
Documentation
Issued 20 January 1999
Resolved
Provide 47 CFR Part 80.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Fire Fighting
Issued 20 January 1999
Resolved
Provide sufficient hose length for hand fire pump for use in fire fighting.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Electrical
Issued 20 January 1999
Resolved
Install electrical stuffing tube for bilge pump motor.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Lifesaving
Issued 20 January 1999
Resolved
Replace one ring buoy that is beyond repair; include vessel name & type II retroreflective tape.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Electrical
Issued 20 January 1999
Resolved
Replace two broken light covers; one in tank space & one in engine room inboard of stbd main engine.
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Fire Fighting
Issued 20 January 1999
Resolved
Show proof of proper fire pump pressure (60 psi) in presence of Marine Inspector. (NO SAIL)
Condition: Unknown
Due 1 February 1999
Resolved 1 February 1999
Lifesaving
Issued 21 January 1998
Resolved
Vessel must provide type 1 retro tape for lifejackets.
Condition: Unknown
Due 15 February 1998
Resolved 18 March 1998
Lifesaving
Issued 21 January 1998
Resolved
Vessel must procure a first aid kit IAW table 160.054-4(b).
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Engineering
Issued 21 January 1998
Resolved
Vessel must procure a machinery guard for diesel generator.
Condition: Unknown
Due 15 February 1998
Resolved 18 March 1998
Fire Fighting
Issued 21 January 1998
Resolved
Vessel must prove all portable fire extinguishers have recieved their annual servicing.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Electrical
Issued 21 January 1998
Resolved
Battery terminals need to be cleaned.
Condition: Unknown
Due 18 March 1998
Resolved 18 March 1998
Engineering
Issued 21 January 1998
Resolved
Vessel must double clamp overboard discharge.
Condition: Unknown
Due 21 January 1998
Resolved 21 January 1998
Electrical
Issued 21 January 1998
Resolved
Vessel must procure a machinery guard for diesel engine.
Condition: Unknown
Due 15 February 1998
Resolved 18 March 1998
Accommodation/Occupational Safety
Issued 22 January 1997
Resolved
PROVIDE EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 22 January 1997
Resolved 28 January 1997
Electrical
Issued 22 January 1997
Resolved
PROVIDE BLANK COVER FOR ELECTRICAL PANEL BOX LOCATED ON THE FORWARD BULKHEAD IN ER.
Condition: Unknown
Due 22 January 1997
Resolved 28 January 1997
Engineering
Issued 22 January 1997
Resolved
PROVIDE A MEANS FOR PREVENTING OIL LEAKAGE, FROM MAIN DIESEL ENGINES AND TWO GENERATORS, FROM ENTERING BILGE.
Condition: Unknown
Due 22 January 1997
Resolved 28 January 1997
Navigation
Issued 22 January 1997
Resolved
PROVIDE UP-TO-DATE U.S. COAST PILOT & C.G. LIGHT LIST.
Condition: Unknown
Due 22 January 1997
Resolved 28 January 1997
Lifesaving
Issued 22 January 1997
Resolved
PROPERLY LABLE CONTAINER FOR DISTRESS SIGNALS.
Condition: Unknown
Due 22 January 1997
Resolved 28 January 1997
Lifesaving
Issued 22 January 1997
Resolved
PROVIDE PROPER BRACKETS FOR TWO LIFERINGS LOCATED AFT ON THE UPPER DECK BEFORE NEXT OPERATION.
Condition: Unknown
Due 22 January 1997
Resolved 28 January 1997
Engineering
Issued 31 January 1996
Resolved
PROVIDE CLEARANCE READINGS FOR STBD TAILSHAFT FWD CUTLESS BEARING (FISHING LINE DAMAGED)
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996
Resolved
PROVE PROPER OPERATION OF REACH ROD TO VALVE IN FOREPEAK
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Construction/Loadline
Issued 31 January 1996
Resolved
Prove watertightness of repair to bilge manifold
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Electrical
Issued 31 January 1996
Resolved
provide proper deck light installation including securing all boxes, properly mounting all cable, sealing holes in boxes, cover cable running across walkway on fwd end of upper deck
Condition: Unknown
Due 31 January 1996
Resolved 31 January 1996
Documentation
Issued 3 May 1993
Resolved
PROVIDE EVIDENCE OF DRUG TESTING PROGRAM.
Condition: Unknown
Due 10 May 1993
Resolved 29 June 1993
Lifesaving
Issued 3 May 1993
Resolved
PROVIDE ADEQUATE RESCUE PLATFORM OR RESCUE BOAT.
Condition: Unknown
Due 3 June 1993
Resolved 29 June 1993
Fire Fighting
Issued 3 May 1993
Resolved
REPLACE CLAMP ON DISCHARGE SIDE ON PORT SIDE FIRE PUMP.
Condition: Unknown
Due 10 May 1993
Resolved 29 June 1993
Engineering
Issued 11 June 1991
Resolved
RENEW FLAME SCREENS FOR BOTH FUEL TANK VENTS.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Construction/Loadline
Issued 11 June 1991
Resolved
PROVIDE REACH ROD FOR BILGE VALVE IN FOREPEAK.
Condition: Unknown
Due 11 June 1991
Resolved 11 June 1991
Engineering
Issued 9 April 1990
Resolved
PROPERLY MARK EMERGENCY FUEL SHUT OFF VALVE.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Electrical
Issued 9 April 1990
Resolved
PROPERLY MARK ELECTRICAL DISTRIBUTION PANELS ON BRIDGE AND IN ENGINE ROOM.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Fire Fighting
Issued 9 April 1990
Resolved
PROVE PROPER OPERATION OF PORT FIRE STATION.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Lifesaving
Issued 9 April 1990
Resolved
PROPERLY INSTALL LIFE FLOATS AND BUOYANT APPARATUS.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Engineering
Issued 9 April 1990
Resolved
PROVIDE METAL FLAME GUARDS FOR RACOR FILTERS.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Lifesaving
Issued 9 April 1990
Resolved
PROPERLY MARK LIFE PRESERVER STORAGE.
Condition: Unknown
Due 9 April 1990
Resolved 9 April 1990
Electrical
Issued 30 November 1989
Resolved
LINE BATTERY BOXES (3 EA) IN ENGINE ROOM WITH LEAD OR FIBERGLASS.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Construction/Loadline
Issued 30 November 1989
Resolved
PROVE WATERTIGHT INTEGRITY OF 5'X12' INSERTS ABOVE KEEL AFT OF COLLISION BULKHEAD. VESSEL CAN NOT CARRY PASSENGERS UNTIL THIS REQUIREMENT IS CLEARED
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Construction/Loadline
Issued 30 November 1989
Resolved
REPAIR CRACKED WELD TOP OF DECK SUPPORT STANCHION STBD SIDE IN #2 COMPARTMENT.
Condition: Unknown
Due 30 November 1989
Resolved 30 November 1989
Navigation
Issued 24 March 1987
Resolved
RELOCATE SIDELIGHTS AFT OF MAST HEADLIGHT AND AS FAR OUTBOARD AS POSSIBLE AS REQUIRED BY 33 CFR 81 ANNEX I.3.(B).
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987
Construction/Loadline
Issued 24 March 1987
Resolved
CROP AND RENEW DAMAGED SHELL PLATING LOCATED AT THE AFT BULKHEAD OF THE FUEL TANK COMPARTMENT BETWEEN THE 1ST AND 2ND SHELL STIFFENER ON STBD SIDE.
Condition: Unknown
Due 24 March 1987
Resolved 24 March 1987