← All vessels
PACIFIC STAR
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named PACIFIC STAR
PACIFIC STAR is a 1977 passenger vessel (inspected). The Coast Guard has recorded 91 inspections since 1984, most recently in December 2025, along with 173 deficiencies, 3 operational controls and 4 casualty investigations between 2002 and 2018.
Records from 1984 to 2025. Most recent: inspection, 17 December 2025.
- Built
- 1977
- Last inspected
- 17 December 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 173 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
- Casualties
- 4 investigations · 2002–2018
Identity
583567
WDQ6243
49236
Flag
UNITED STATES
367655170
Maury page id
psix-49236
Inspections, by type
…with no type recorded14
Years with a record
35 calendar years (1984–2025)
The 91 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)64.8 ft × 21.3 ft × 5.7 ft
Registered tonnagegross 55 / net 23
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderF. L. CHAFFEE · CHULA VISTA, CA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portREDONDO BEACH, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 3 January 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it55 - Regulatory (Subpart C or D), Gross Ton
23 - Regulatory (Subpart C or D), Net Ton
23 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDQ6243MMSI 367655170 · active · compulsorily equipped · granted 1 October 2025, expires 1 October 2035
WDH8150MMSI 367655170 · expired · compulsorily equipped · granted 29 January 2015, cancelled 5 April 2025
WDC2007MMSI 366986390 · expired · compulsorily equipped · granted 27 October 2004, cancelled 27 December 2014 · licensed under a name not among this hull’s recorded names (not shown)
WBR6258MMSI not assigned · expired · compulsorily equipped · granted 3 September 1998, cancelled 24 January 2009
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 91
17 December 2025
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8257381
9 October 2025
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8215285
1 June 2025
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8127523
9 December 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8026729
31 July 2024
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7959154
8 January 2024
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7826059
20 December 2023
Internal Structural Exam · Hull Examination · Examination of Repairs
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7826741
15 December 2023
Administrative Inspection · Special Consideration
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7847717
24 July 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7741617
29 March 2023
In-Service Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7654647
9 March 2023
Plan Review (Other than "T")
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7648338
3 January 2023
Administrative Inspection · Deficiency Check · Annual Inspection · Plan Review "T" Boat
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7595723
21 December 2022
Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7621129
12 March 2022
Type not recorded
No type recorded · Station Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7410640
21 January 2022
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7383929
13 December 2021
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7367039
22 October 2020
Deficiency Check · COI Inspection · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7076605
14 January 2020
Hull Examination · Deficiency Check · Administrative Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6889606
2 October 2019
Annual Inspection · In-Service Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6815920
10 January 2019
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6595964
5 August 2018
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6510776
6 February 2018
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6351087
26 January 2018
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6341816
5 December 2017
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6306797
11 November 2017
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6307324
26 January 2017
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6077959
5 January 2017
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6060125
23 November 2015
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5768636
28 October 2015
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 5742028
15 February 2012
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4248381
27 January 2012
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4231105
11 January 2012
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4047027
3 January 2011
Administrative Inspection
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 4184159
29 October 2010
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3881029
26 October 2010
DAPI Audit · COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3873088
20 February 2009
Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3420007
6 January 2009
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3352466
20 December 2007
Annual Inspection · Deficiency Check
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3117202
4 December 2007
Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3089820
28 November 2005
Internal Structural Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2545581
28 October 2005
COI Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2523284
14 November 2003
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1943791
25 February 2003
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1749282
22 June 2002
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1635735
4 March 2002
Annual Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1490396
26 November 2001
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1362567
2 February 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1456939
1 December 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 812038
16 November 1999
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 809992
20 September 1999
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1121642
24 September 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 799238
31 December 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1386127
23 September 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1371987
26 September 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1357748
30 January 1996
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1193075
13 December 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1189470
14 November 1995
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1385610
19 October 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 878134
7 September 1995
Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1185631
3 August 1995
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 876590
23 January 1995
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1144202
2 December 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1179733
22 November 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1175079
26 October 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1356877
8 October 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 839035
27 September 1993
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1467389
3 September 1993
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 826562
3 September 1993
Plan Review "T" Boat
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 833787
3 September 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1137770
20 August 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1440736
19 August 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 15804
15 February 1993
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 830563
13 January 1993
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1136180
21 May 1992
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1262097
22 April 1992
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 950606
15 November 1991
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 941436
1 May 1991
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 917037
19 September 1990
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 900158
23 October 1989
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 896136
24 April 1989
COI Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1341293
30 June 1988
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1209812
30 March 1988
Hull Examination
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 992067
30 March 1988
Administrative
Administrative · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1346402
2 September 1987
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1001767
25 June 1987
Re-Inspection
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1007499
16 September 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1311544
12 August 1986
Type not recorded
No type recorded · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1307313
4 June 1986
Deficiency Check
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1296410
24 April 1986
COI Inspection · Credit Drydock
Physical examination · MSO LOS ANGELES/LONG BEACH · USCG Southwest District (CGD-SW) · Activity 1308612
25 June 1985
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 983816
16 November 1984
Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1284647
Deficiency record · 173
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 9 October 2025
Resolved
All vsls shall be provided with an approved adult type life preserver for each person carried; condemned (01) lifejacket for poor condition. Replaced on the spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 9 December 2024
Resolved
When engines are freshwater cooled and have and the exhaust pipe is cooled by a separate water cooling system, a suitable warning, visual or audible at the operating station should be provided to indicate a failure of water flow in the exhaust system. Both generators have exhaust cooling provided by external pumps which are not provided with the required alarms.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 December 2024
Resolved
In systems and applications where flexible hoses are permitted to be clamped:(1) Double hose clamping is required where practicable; An exhaust hose clamp on the starboard main diesel engine in way of the lazarette was found corroded and broken.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 9 December 2024
Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The following items in the engine room were found unsecured for sea and require securing: All battery boxes, tool box, starboard side fresh water pumps, and the center watermake pump.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 December 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems. Port side main diesel engine found to be holed and repaired with JB weld. Replace holes section of pipe or submit a repair proposal for permanent repairs.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 9 December 2024
Resolved
Piping, including valves, pipe fittings and flanges, conveying vapor, gas, or liquid, the temperature of which exceeds 65.5 °C (150 °F), must be suitably insulated where necessary to prevent injuries. Starboard main diesel engine missing protective lagging near turbo charger.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 December 2024
Resolved
The ring life buoys shall be colored international orange. Ring buoys found to be badly worn and discolored. Replace ring buoys.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 8 January 2024
Resolved
Each survival craft required on a vessel by this part must remain in good and serviceable condition. 02 life rafts are in poor condition and not serviceable.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 3 January 2023
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. No valid COD could be produced for the vessel. Provide valid original or certified copy of COD, COD must remain on board while vessel is underway.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 3 January 2023
Resolved
A power-driven vessel underway shall exhibit a stern light that is white with a visibility of 2 miles, showing an unbroken light over an arc of the horizon of 135 degrees. Vessel did not have a stern light installed on board. Provide a stern light to the standards mentions above; vessel is restricted from operating from sunrise to sunset in restricted visibility and other circumstances when it is deemed necessary to exhibit navigational lights.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 January 2023
Resolved
A submersible electric bilge pump may not be used to dewater not more than one watertight compartment. Submersible bilge pump in engine room is currently used to dewater both E/R compartment and forward berthing compartment; forward berthing compartment has installed submersible bilge pump but discharges into engine room and then E/R pump would discharge that water overboard. Submit plans to reconfigure bilge system so that each submersible bilge pump dewaters compartment in which pump is installed and to the standards listed in 46CFR182.520(e)1-8.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 January 2023
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with
NFPA 10. Annual servicing of 10 B:C portable fire extinguisher for wheel house was not serviced. Provide servicing for portable fire extinguisher on-board or new extinguisher may be purchased.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 3 January 2023
Resolved
A submersible electric bilge pump must have a positive shutoff valve is installed at the hull penetration and flexible tube or hose may be used instead of fixed pipe for the discharge line of a submersible electric bilge pump provided the hose is of good quality and of substantial construction. E/R bilge pump hull penetration does not have a positive shutoff valve and forward compartment bilge pump piping is not of substantial construction. Provide positive shut off valve for E/R hull penetration discharge, and bilge piping of substantial construction for all bilge piping.
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 January 2023
Resolved
Batteries shall be located in an enclosure of suitable construction material so that it is resistant to deteriorating action by the battery electrolyte. Battery under anchor windlass was not secured in an enclosure resistant to battery electrolyte. Provide corrosive resistant enclosure for windlass battery. OLD T 46 CFR 183.02-20(d)
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 January 2023
Resolved
Battery terminals shall be of the soldered type and all connections shall be made to the battery terminals with permanent type connections. Battery terminal for wheelhouse batteries, Port E/R starting battery was secured with a wing nuts. Provide connection means of a permanent type for all battery terminal connections. OLD T 46 CFR 183.05-20(c)
09 - Working and Living Conditions › 092 - Working Conditions › Other (accident prevention)
Issued 3 January 2023
Resolved
All electric cooking equipment shall be provided with doors with heavy duty hinges and locking devices to prevent accidental opening in heavy seas and be provided with sea rails with suitable barriers to resist accidental cook pot movement. Electric range installed with no locking devices on doors nor sea rails to prevent accidental injuries to crew. Provide adequate locking devices on doors and install suitable sea rails on range top. OLD T 46 CFR 183.10-45 (b)(1)/(3)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 3 January 2023
Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Portside generator belt drive system is not protected by any guards and potentially exposes crew to unprotected rotating machinery. Provide adequate cover to protect crew members from rotating belt drive system on port generator. OLD T 46 CFR 177.35-15
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 January 2023
Resolved
All cable and wire must be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Plastic zip ties were being used to support and bundle electrical cables; zip ties may be used to bundle wires/cables but not support. Provide vertical and horizontal metal supports at intervals no more than 24” apart for electrical cables in engine room, compressor room.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 3 January 2023
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material approved in accordance with 46 CFR 164.018 or other standard specified by the Commandant. Retroreflective tape on ring buoy and Portside Life raft was worn/sun damaged. Replace retro tape on ring buoy and life float.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 3 January 2023
Resolved
All escape hatches and other emergency exits shall be marked on both sides using at least 1-inch letters:
"Emergency Exit, Keep Clear". Emergency escape hatch was not marked on top. Properly mark the top of the emergency escape hatch in the lounge/galley area. OLD T 46 CFR 185.30-15
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 3 January 2023
Resolved
All electrical equipment and circuits must be clearly marked and identified. Multiple breakers in both distribution panel in passenger berthing and in wheel house were not labeled to indicate supplied source of power. Clearly mark all electrical circuits in electrical distribution panels.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 3 January 2023
Resolved
It shall be the duty of the master of any vessel to assure that all exposed hatches are properly secured before getting underway for a voyage on other than protected waters. Gasket for hatch to collision bulkhead space gasket was found partiality detached from hatch. Repair/replace gasket so that hatch is watertight. OLD T 46 CFR 185.20-15
09 - Working and Living Conditions › 091 - Living Conditions › Other (crew and accommodation)
Issued 3 January 2023
Resolved
Vessels with overnight passenger accommodations must submit plans to the cognizant OCMI, for the installation and use of monitoring device to ensure the wakefulness of the watchmen. The monitoring device(s) must: (1) Ensure the wakefulness of the crew in the event that the watchman is unresponsive; (2) Remain operable during the nighttime watch; and (3) Be arranged to ensure proper coverage of the passenger accommodation spaces, common areas, and spaces with potential fire hazards. Submit plans to the Coast Guard (Sector LA/LB) for the proposed installation of watchmen system.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 1 January 2022
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. Vessel exceeded two year interval on 31DEC2021 by not repairing areas of hull that the NDT report identified as being more than 30% wasted. Vessel must undergo satisfactory drydock examination prior to carrying passengers.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2020
Resolved
EXHAUST PIPING SHALL BE LED TO THE POINT OF ESCAPE WITH A MINIMUM NUMBER OF BENDS OR ELBOWS. IT SHALL BE GAS TIGHT THROUGHOUT ITS LENGTH AND SHALL BE PROPERLY SUPPORTED BY NON-COMBUSTIBLE HANGERS OR BLOCKS. MARINE INSPECTOR OBSERVED WATER AND GAS LEAK IN WET EXHAUST SYSTEM.(46CFR182.15-20(a))
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 October 2020
Resolved
AN ADULT LIFE JACKET MUST BE PROVIDED FOR EACH PERSON CARRIED ON BOARD A VESSEL. CONDEMNED 01 LIFEJACKET. OWNER REPALCED WITH 01 LIFEJACKET.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 October 2020
Resolved
EACH LIFE JACKET MUST BE MARKED WITH TYPE I RETROREFLECTIVE MATERIAL APPROVED IN 46CFR164.018 OR OTHER STANDARD SPECIFIED BY THE COMMANDANT MARINE INSPECTOR FOUND 02 CHILDRENS AND 05 ADULT LIFE JACKETS WITH UNSATISFACTORY RETROREFLECTIVE MATERIAL. OWNER REPLACED WITH SATISFACTORY RETROREFLECTIVE MATERIAL. (46CFR185.604(h))
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2020
Resolved
A VESSEL IS INSPECTED FOR COMPLIANCE WITH THE STANDARDS REQUIRED BY THIS SUBCHAPTER MACHINERY EQUIPMENT...NOT COVERED BY STANDARDS IN THE SUBCHAPTER MAY BE INSPECTED IN ACCORDANCE WITH STANDARDS ACCEPTBLE TO THE COGNIZANT OCMI AS GOOD MARINE PRACTICE. MARINE INSPECTOR DISCOVERED EXCESSIVE OIL ACCUMULATION AROUND GENERATOR WINDINGS. (46CFR176.900(a))
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 22 October 2020
Resolved
A VESSEL IS INSPECTE4D FOR COMPLIANCE WITH THE STANDARDS REQUIRED BY THIS SUBCHAPTER MACHINERY EQUIPMENT...NOT COVERED BY STANDARDS IN THIS SUBCHAPTER MAY BE INSPECTED IN ACCORDANCE WITH STANDARDS ACCEPTABLE TO THE COGNIZANT OCMI AS GOOD MARINE PRACTICE. MI OBSERVED SEVERAL RAW WATER HOSES IN UNSATISFACTORY CONDITION. (46CFR176.800(a))
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 14 January 2020
Resolved
Vessel must complete a satisfactory dry dock prior to carrying passengers.
05 - Radio Communications › N/A - No Subsystem › Satellite EPIRB 406MHz/1.6GHz
Issued 2 October 2019
Resolved
Each vessel that operates on the high seas or that operates beyond three miles from the Coastline, must have on board a FCC Type accepted Cat 1 406 MHz EPIRB installed to automatically float free and activate.
EPIRB hydrostatic release is expired. Provide valid hydrostatic release. Restricted to 3 miles from land until replaced.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 October 2019
Resolved
Overload/circuit protective devices, the ratings of fuses shall be suitable for the service intended.
A 30 AMP breaker labeled "Port outlet" was found protecting a 14 gauge wire.
Overcurrent protection of 14 gauge wire not to exceed 15 AMP.
Old T 46 CFR 176.25-15(a)(2)
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 2 October 2019
Resolved
Distribution panels shall be protected so that uninsulated parts cannot be inadvertently touched.
Found berthing panel with open spaces between breakers. Required to install proper blank covers on panel.
Old T 46CFR183.10-13
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 October 2019
Resolved
An adult life jacket must be provided for each person carried on board a vessel.
Total adult serviceable adult life jackets of Type I count was 40. Provide 5 Type I adult life jackets. Restricted to 40 adult total persons on board.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 January 2019
Resolved
Port Navigational light dimly lit. Found incorrect bulb to be installed.
11 - Life Saving Appliances › N/A - No Subsystem › On board training and instructions
Issued 10 January 2019
Resolved
Incorrect placard for style of life jackets onboard. Vessel has different styles of life jackets with only instructions for one type.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 10 January 2019
Resolved
07 life jackets have degraded retro material. 01 was corrected on the spot. 06 need to be corrected
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 10 January 2019
Resolved
Starboard Life float is not in serviceable condition. Provide replacement.
11 - Life Saving Appliances › N/A - No Subsystem › Stowage and provision of liferafts
Issued 10 January 2019
Resolved
Provide replacement oars for 2 life rafts.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 10 January 2019
Resolved
Provide window replacement for cracked aft-starboard pilot house window.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 10 January 2019
Resolved
Provide new life raft light.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 10 January 2019
Resolved
Provide current Coast Pilot
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 10 January 2019
Resolved
Provide updated Ship's log (EPIRB log).
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 26 January 2018
Resolved
Provide stern light 135 degree white light.
Construction/Loadline › Hull › Keel Plate
Issued 5 December 2017
Resolved
Repair small leak in keel structure.
Electrical › Electric Generation Source (service) › Generator
Issued 5 January 2017
Resolved
Clean windings of both generators, main alternators, and engine room ventilation fans.
Electrical › Electrical Distribution System (service) › Cable
Issued 5 January 2017
Resolved
Remove dead end cables from engine and compressor room
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 28 October 2015
Resolved
Provide 05 adult lifejackets
Lifesaving › Lifefloat › Markings
Issued 28 October 2015
Resolved
Restencil Vessel name and passenger count on life floats
Lifesaving › Hand Flares › Expired
Issued 28 October 2015
Resolved
Provide 06 red hand flares. Vessel LBS until corrected
Engineering › Diesel Engine (propulsion-direct drive) › Exhaust Manifold
Issued 28 October 2015
Resolved
Repair exhaust leaks on the port and starboard main diesel engine
Electrical › Electric Supply System (service) › Battery Installation
Issued 28 October 2015
Resolved
Replace temperary connections on batteries with permenant type connectors
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 October 2015
Resolved
Remove or relabel dead end wiring throughout vessel
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 October 2015
Resolved
Replace all batteries within float lights
Communications › Alarms/Indicators › Bilge Alarm
Issued 27 January 2012
Resolved
Repair bilge alarm for forward stateroom to provide audible and visual alarm in the operating station prior to carrying passengers for hire
Fire Fighting › Portable CO2 Fire Extinguisher › Number
Issued 27 January 2012
Resolved
Provide current servicing report for all expired fire extinguishers and all fire extinguishers that have not been serviced, prior to carrying passengers.
Communications › Radio Communications › EPIRB
Issued 27 January 2012
Resolved
Provide valid EPIRB, route limited to no more than 3 miles from land until corrected.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 27 January 2012
Resolved
Provide retroreflective tape for the ringbuoys (2 required new tape).
Documentation › Certificates/Documents › Certificate of Inspection
Issued 27 January 2012
Resolved
Post all pages of COI in vessel's salon under glass or other transparent material
Navigation › Piloting/Steering › Marine Charts
Issued 27 January 2012
Resolved
Provide up to date charts for vessel's operating area
Communications › Alarms/Indicators › General Alarm
Issued 27 January 2012
Resolved
Provide general alarm system in bunkrooms as per 46 CFR 183.550. No overnight trips until system installed.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 27 January 2012
Resolved
Provide stern light. Vessel limited to daytime operations only until corrected.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 27 January 2012
Resolved
Provide valid FCC Safety Certificate
Fire Fighting › Means of Escape › Escape Route Signs
Issued 27 January 2012
Resolved
Label emergency escape hatch "EMERGENCY EXIT, KEEP CLEAR" on exit side of hatch in salon. Labeling must be at least 2 inches high.
Lifesaving › Buoyant Apparatus › Marking
Issued 27 January 2012
Resolved
Label 03 Lifefloats with maximum number of persons capacity
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 27 January 2012
Resolved
Blank off vacant breakers on Distribution Panel in Operating Station
Documentation › Certificates/Documents › FCC SSL
Issued 26 October 2010
Resolved
Provide a valid FCC Radio Safety certificate.
Lifesaving › Lifefloat › Serviceable
Issued 26 October 2010
Resolved
Repair damaged lifefloat.
Lifesaving › Inflatable Buoyant Apparatus › Not on Board
Issued 26 October 2010
Resolved
Provide an Inflatable Buoyant Apparatus. Vessel's route will be limited to coastwise on 1Jan11 if an IBA is not provided.
Navigation › Piloting/Steering › US Coast Pilot
Issued 6 January 2009
Resolved
Provide up-to date Coast Pilot [name withheld] and corrections for nautical charts IAW 46CFR184.420.
Engineering › Sea-water System (primary cooling) › Piping
Issued 6 January 2009
Resolved
Replace cooling water supply hose for stbd generator.
Electrical › Electric Generation Source (service) › Conductor
Issued 6 January 2009
Resolved
Remove or reconnect dead end wires on port main engine.
Engineering › Shafting/Propeller Arrangements › Stern Tube Lubrication/Sealing
Issued 6 January 2009
Resolved
Repack stbd shaft (slow leak).
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 20 December 2007
Resolved
Provide proof of valid certificate of documentation. (It expired in November of 2006).
Operations/Management › Drug and Alcohol Testing › Recordkeeping
Issued 20 December 2007
Resolved
Provide all required documentation and make ready for a drug and alcohol program audit.
Lifesaving › Hand Flares › Quantity
Issued 20 December 2007
Resolved
Provide 05 additional orange distress signals IAW 46 CFR 180.68.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Service
Issued 20 December 2007
Resolved
Provide proper portable fire extinguishers in galley and engine room (machinery space) IAW 46 CFR 181.500
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 20 December 2007
Resolved
Clean excess oil and soot from engines, generators, and machinery space in general.
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 20 December 2007
Resolved
Provide current CPR/first aid certifications for at least 50% pf the crew.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 20 December 2007
Resolved
Provide current NOAA registration decal to be affixed on EPIRB.
Documentation › Manuals/Policy Documentation › Training Manual (lifesaving)
Issued 20 December 2007
Resolved
Provide training log IAW 46 CFR 185.420
Lifesaving › Lifefloat › Retroreflective Material
Issued 20 December 2007
Resolved
Make necessary repairs to top starboard life float to include new retro-reflective tape and minor foam repairs IAW manufacturer's requirements.
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 20 December 2007
Resolved
Provide 06 additional adult life jackets . Total person count reduced to 38.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 December 2007
Resolved
Provide appropriate cover for junction box in lazarette.
Electrical › Lighting (service) › Lighting Fixture
Issued 20 December 2007
Resolved
Hardwire lights against aft bulkhead in accommodation space.
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type III
Issued 20 December 2007
Resolved
Provide means of locking overboard discharge valve for sewage system.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 December 2007
Resolved
Provide proper splices for wiring in cabinet for sewage vacuum pump.
Electrical › Electric Supply System (service) › Battery Charger
Issued 20 December 2007
Resolved
Hardwire battery chargers in engine room.
Engineering › Generator (propulsion-electric) › Switch
Issued 20 December 2007
Resolved
Install knob for governor on starboard generator.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 20 December 2007
Resolved
Provide proper splices for wiring in junction box in lazarette.
Documentation › Logs/Records › Transfer Equipment Test/Inspection Records
Issued 20 December 2007
Resolved
Hydrostatically test mixed gas bottle located in closet on main deck.
Operations/Management › Drills/Instruction › Not Conducted
Issued 20 December 2007
Resolved
Conduct satisfactory fire and man overboard drills in the presence of a Coast Guard Marine Inspector.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 20 December 2007
Resolved
Install 30x30 mesh for the fuel vent piping IAW 46CFR 182.20-35(d)
Personnel › Manning/Qualifications › Minimum Safe Manning
Issued 20 December 2007
Resolved
Provide training records for the senior deck hand position. Vessel is restricted from using the senior deckhand position and must operate with a licensed mate when the senior deckhand position is allowed by the COI.
Electrical › Electrical Distribution System (service) › Distribution Panel Bus
Issued 28 October 2005
Resolved
Distribution panel in wheel house is not totally of the dead front type. Provide installation on panel to ensure dead front type IAW 46CFR183.330(b)
Lifesaving › Hand Flares › Quantity
Issued 28 October 2005
Resolved
Six orange smoke distress signals not provided. Provide approved distress signals IAW 46 CFR 180.68 prior to carrying passengers.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 28 October 2005
Resolved
Not all life floats fitted with approved lights. Provide approved lights and proper installation IAW 46 CFR 18.175(d) & 46 CFR 180.175(f)(4)
Electrical › Lighting (service) › Lighting Fixture
Issued 28 October 2005
Resolved
Side navigation light lenses hazed over and prevent light from being seen. Provide proper installation IAW 46 CFR 183.420.
Documentation › Certificates/Documents › Proof of Consortium Enrollment (DAPI)
Issued 28 October 2005
Resolved
Random drug testing program not in place. Provide proof of random testing program IAW 46 CFR 16.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 28 October 2005
Resolved
No documentation of FCC Safety Radio Certificate provided. Provide FCC Safety Radio Certificate IAW 47 CFR 80.
Communications › Radio Communications › EPIRB
Issued 28 October 2005
Resolved
No proof of EPIRB registration provided and current registration out of date. Provide proof of current registration IAW 46 CFR 183.330(b)
Accommodation/Occupational Safety › Occupational Safety › Storm Rail
Issued 28 October 2005
Resolved
Sea rails not provided on cooking range. Provide sea rails IAW 46 CFR 184.220(e)
Lifesaving › Buoyant Apparatus
Issued 25 February 2003
Resolved
Provide water light for Life Float LEGACY COMPONENT DESC: Floating Water Light
Lifesaving › Hand Flares › Quantity
Issued 25 February 2003
Resolved
Provide three additional red handheld flares.
Engineering › Bilge Water Management System
Issued 25 February 2003
Resolved
Install audible bilge high level alarm in Engineroom. LEGACY COMPONENT DESC: Audible alarm
Electrical › Electrical Distribution System (service) › Junction Box
Issued 25 February 2003
Resolved
Provide cover plate for electrical recepticle located on bridge.
Construction/Loadline › Hull › Side Shell
Issued 26 November 2001
Resolved
Repair cracked weld, starboard side bunkroom, IVO #2 from top, longitudinal. Repair as original.
Engineering › Freshwater System (intermediary cooling)
Issued 26 November 2001
Resolved
Double clamp all keel cooler hoses.
Engineering › Shafting/Propeller Arrangements › Strut Bearing
Issued 26 November 2001
Resolved
Replace prot and starboard cutlass bearings on strut tubes and shaft tubes (4 total).
Construction/Loadline
Issued 31 December 1997
Resolved
REPAIR BROKEN DECK SUPPORTS IN ENGINE ROOM.
Construction/Loadline
Issued 31 December 1997
Resolved
REWELD OVERHEAD LONGITUDINAL SUPPORT BEAM IN LAZARETTE ON STARBOARD SIDE.
Construction/Loadline
Issued 31 December 1997
Resolved
REPAIR CRACKED WELDS BETWEEN OVERHEAD AND OVERHEAD SUPPORT BEAMS IN LAZARETTE.
Electrical
Issued 26 September 1996
Resolved
PROVE PROPER OPERATION OF PORT GENERATOR.
Fire Fighting
Issued 26 October 1994
Resolved
SERVICE ALL FIRE EXTINGUISHERS. TO BE COMPLETED PRIOR TO CARRYING PASSENGERS.
Fire Fighting
Issued 26 October 1994
Resolved
PROVIDE PIN FOR B-I EXTINGUISHER IN GALLEY STBD SIDE. PROVIDE WIRE TO HOLDPIN IN PLACE FOR BOTH B-I EXTINGUISHERS (GALLEY & BRIDGE).
Engineering
Issued 26 October 1994
Resolved
REPLACE FLAME SCREENS ON STBD SIDE (SEMI-CLOGGED W/PAINT).
Unknown
Issued 26 October 1994
Resolved
PROVE OPERATION OF AIR COMPRESSOR.
Lifesaving
Issued 26 October 1994
Resolved
PROVIDE 1 CHILD PFD AS PER CERTIFICATE OF INSPECTION.
Documentation
Issued 26 October 1994
Resolved
PROVIDE SENIOR DECKHAND LETTER.
Lifesaving
Issued 26 October 1994
Resolved
INSTALL SPACERS BETWEEN LIFEFLOATS STACKED IN STORAGE.
Construction/Loadline
Issued 27 September 1993
Resolved
MOUNT HAND PUMP ON BOARD AND LABLE INTAKE AND OUTPUT SIDE OF PUMP.
Navigation
Issued 27 September 1993
Resolved
PROVIDE COMPASS DEVIATION TABLE AND MOUNT ON THE BRIDGE.
Documentation
Issued 13 January 1993
Resolved
IN THE PRESENCE OF A USCG MARINE INSPECTOR, CONDUCT A STABILITY TEST AS DESCRIBED IN 46 CFR 171.030. THIS ITEM IS TO BE COMPLETED PRIOR TO_x001C_ 12 FEBRUARY 1993.
Navigation
Issued 22 April 1992
Resolved
PROVIDE REQUIRED NAUTICAL PUBLICATIONS AS REQUIRED BY 46CFR185.20-35 AND UPDATE/CORRECT CHARTS.
Engineering
Issued 22 April 1992
Resolved
REPAIR/REPLACE ENGINE EXHAUST COWLINGS ON THE WHEELHOUSE DECK.
Lifesaving
Issued 22 April 1992
Resolved
CONDUCT UNDERWAY FIRE AND MAN OVERBOARD DRILLS TO THE SATISFACTION OF AN ATTENDING COAST GUARD INSPECTOR.
Navigation
Issued 22 April 1992
Resolved
REPAIR AND PROVE PROPER OPERATION OF LOWER JRC RADAR.
Engineering
Issued 22 April 1992
Resolved
REPAIR HOLES IN PORT ENGINE EXHAUST PIPING.
Lifesaving
Issued 22 April 1992
Resolved
PROVIDE LIGHTS FOR 3 ADULT LIFE JACKETS AND AN ADDITIONAL ADULT LIFE JACKET. VESSEL IS LIMITED TO CARRYING NOT MORE THAN 39 ADULT PASSENGERS ONOCEANS ROUTE OR COASTWISE ROUTE UNTIL LIGHTS AND ADDITIONAL JACKET ARE PROVIDED.
Lifesaving
Issued 22 April 1992
Resolved
REMOVE FLAMMABLES STOWED IN STARBOARD HEAD AND STOW IN APPROPRIATE FLAMMABLE LOCKER OR REMOVE FROM VESSEL.
Engineering
Issued 22 April 1992
Resolved
REPAIR/PROPERLY SUPPORT EXHAUST PIPING AND MUFFLER FOR STARBOARD GENERATOR WHERE BROKEN.
Accommodation/Occupational Safety
Issued 22 April 1992
Resolved
PROVIDE WASTE MANAGEMENT PLAN.
Electrical
Issued 22 April 1992
Resolved
REPAIR AND PROVE PROPER OPERATION OF PORT GENERATOR.
Electrical
Issued 22 April 1992
Resolved
PROVIDE METALLIC WIRE SUPPORT BRACKETS A MINIMUM OF EVERY 24" FOR VITAL ELECTRONIC WIRING BENEATH BRIDGE CONSOLE.
Navigation
Issued 22 April 1992
Resolved
REPAIR/PROVE PROPER OPERATION OF LOWER (WHITE) FISHING LIGHT.
Navigation
Issued 22 April 1992
Resolved
PROVIDE REQUIRED DAY SHAPE FOR VESSEL AT ANCHOR.
Lifesaving
Issued 22 April 1992
Resolved
LABEL/MARK STOWAGE OF 7 ADULT LIFE JACKETS IN THE UNMARKED LOCATION.
Lifesaving
Issued 22 April 1992
Resolved
PROVIDE EVIDENCE OF PARTICIPATION IN A RANDOM DRUG TESTING PROGRAM.
Electrical
Issued 22 April 1992
Resolved
INSTALL CORROSION RESISTANT TRAY (MIN 3" DEPTH) FOR BATTERY ON WHEEL HOUSE DECK.
Construction/Loadline
Issued 22 April 1992
Resolved
REPAIR LEAKING WATER LINE (SALT WATER) AT STARBOARD SIDE FORWARD BULKHEAD OF ENGINEROOM.
Documentation
Issued 1 May 1991
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Navigation
Issued 1 May 1991
Resolved
PROVE OPERATION OF FATHOMETER AND LOWER RADAR.
Electrical
Issued 19 September 1990
Resolved
PROVE CABLE CONNECTING BRIDGE PANEL WITH BATTERY AND ENGINE COMPLIES WITH 46 CFR 183.05-45(E) OR IS THE CABLE IDENTIFIED ON CG APPROVED DRAWINGS.
Lifesaving
Issued 19 September 1990
Resolved
PROVIDE ADDITIONAL 5 ADULT AND 3 CHILD LIFE PRESERVERS. THE TOTAL NUMBER OF PERSONS ALLOWED ON BOARD IS REDUCED TO 42 UNTIL THIS REQUIREMENT IS COMPLETED.
Construction/Loadline
Issued 19 September 1990
Resolved
PROVE WEATHERTIGHT CAPABILITY OF ALL FOUR MAIN DECK ACCESS SCUTTLES.
Lifesaving
Issued 19 September 1990
Resolved
PROVIDE THREE ADDITIONAL CHILD LIFE PRESERVERS.
Accommodation/Occupational Safety
Issued 19 September 1990
Resolved
PROVE PROPER INSTALLATION AND OPERATION OF MSD SYSTEM.
Lifesaving
Issued 24 April 1989
Resolved
PROVIDE WATERPROOF CONTAINER FOR FLARES.
Lifesaving
Issued 24 April 1989
Resolved
STENCIL NAME ON RING BUOY AND ADD SEPARATE LINE FOR WATERLIGHT.
Documentation
Issued 24 April 1989
Resolved
PROVIDE VALID FCC RADIOTELEPHONY CERTIFICATE.
Electrical
Issued 24 April 1989
Resolved
PLACE ALL WIRING TO CENTER MDE IN A JUNCTION BOX; REMOVE ALL SPLICES IN 110V LIGHTING SYSTEM.
Fire Fighting
Issued 24 April 1989
Resolved
PROVIDE DISCHARGE & PICKUP HOSES FOR HAND FIRE PUMP.
Construction/Loadline
Issued 24 April 1989
Resolved
REPLACE BROKEN WINDOWS IN GALLEY & ON BRIDGE.
Electrical
Issued 24 April 1989
Resolved
REMOVE ALL EXTENSION CORDS; GROUND ALL APPLIANCES IN GALLEY AND PLACE WIRESFROM SOUP WARMER IN A JUNCTION BOX.
Lifesaving
Issued 24 April 1989
Resolved
PATCH HOLES IN LIFEFLOAT, MAKE UP NET IN ONE L/F AND STENCIL ALL OARS.
Electrical
Issued 24 April 1989
Resolved
PROVIDE LIGHT COVER ON BRIDGE LIGHT.
Electrical
Issued 30 June 1988
Resolved
PROVIDE CIRCUIT BREAKER BOXES WITH COVERS FOR MISSING BREAKERS, PROVIDE LABELS FOR ALL BREAKERS.
Lifesaving
Issued 30 June 1988
Resolved
PROVIDE ONE ADDITIONAL EMERGENCY LIGHT FOR FORWARD END OF PASSENGER'S BERTHING AREA.
Engineering
Issued 30 June 1988
Resolved
REPAIR/INSTALL AND PROVE PROPER OPERATION OF CENTER MAIN ENGINE.
Navigation
Issued 30 June 1988
Resolved
REPAIR OR REMOVE INOPERATIVE BRIDGE EQUIPMENT: TWO FATHOMETERS, RUDDER ANGLE INDICATOR AND LORAN C RECEIVER.
Electrical
Issued 30 June 1988
Resolved
PROPERLY SUPPORT ELECTRICAL WIRING THROUGHOUT VESSEL. METALLIC SUPPORTS/ BINDING REQUIRED EVERY 24 INCHES.
Engineering
Issued 30 June 1988
Resolved
MAKE PERMANENT REPAIRS TO MAIN ENGINE THROTTLES ON THE BRIDGE.
Electrical
Issued 30 June 1988
Resolved
REPAIR AND PROVE PROPER OPERATION OF 12KW GENERATOR.
Accommodation/Occupational Safety
Issued 30 June 1988
Resolved
LABEL TOPSIDE OF EMERGENCY ESCAPE HATCH.
Engineering
Issued 30 June 1988
Resolved
PROVIDE ALL NONMETALLIC RUBBER HOSES IN ENGINEROOM WITH DOUBLE CLAMPS.
Electrical
Issued 30 June 1988
Resolved
REMOVE ALL WIRE NUTS FROM ELECTRICAL SPLICES AND MAKE PROPER ELECTRICAL SPLICES.
Navigation
Issued 25 June 1987
Resolved
REPAIR HYDRAULIC LEAK IN STEERING SYSTEM IN PILOT HOUSE.
Electrical
Issued 25 June 1987
Resolved
CLOSE UP 110 VOLT BOARD IN PILOT HOUSE CONSOLE.
Construction/Loadline
Issued 25 June 1987
Resolved
INSTALL SECURING DEVICE ON BERTHING DOOR.
Accommodation/Occupational Safety
Issued 25 June 1987
Resolved
RENEW ALL BROKEN WINDOWS.
Construction/Loadline
Issued 25 June 1987
Resolved
WELD UP 1/2 INCH DIAMETER HOLE IN TRANSOM ON PORT SIDE.
Engineering
Issued 24 April 1986
Resolved
RENEW STRD STRUT BEARING.
Lifesaving
Issued 24 April 1986
Resolved
MOUNT WATER LIGHTS TO LIFE FLOATS, SO THAT THEY WILL FLOAT FREE.
Casualty record · 4
22 June 2002Routine · role: Involved in a Marine Casualty · 1 injured · activity 1635735
9 September 2012Routine · role: Involved in a Marine Casualty · activity 4438254
11 November 2017Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 dead · 1 injured · activity 6307324
5 August 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6510776
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.