Records from 2007 to 2026. Most recent: inspection, 11 May 2026.
Inspection history · 36
11 May 2026
Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8370674
3 April 2026
MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8341421
20 November 2025
Plan Review "T" Boat
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8285071
28 May 2025
Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8145977
3 April 2025
Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8104333
22 July 2024
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7963880
17 July 2024
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7960996
2 April 2024
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7888499
4 October 2023
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7803414
10 August 2023
Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7765707
2 May 2023
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7680756
14 April 2023
Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7668948
4 April 2023
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7662073
24 October 2022
Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7582895
25 March 2022
COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7411526
7 July 2021
In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7249397
10 June 2021
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7221327
25 March 2021
DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7162483
25 March 2021
Plan Review (Other than "T") · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7379560
14 January 2021
Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7124592
31 March 2020
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6940481
26 March 2020
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6935795
2 May 2019
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6683660
22 March 2019
DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6657884
5 September 2018
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6537704
26 June 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6456253
14 June 2018
Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6443826
24 October 2017
Construction Oversight · Annual Inspection · Internal Structural Exam · Inclining Experiment · Examination of Repairs · Drydock Exam · Hull Examination · Deficiency Check · Administrative Inspection · Deadweight Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6294102
10 July 2017
Re-Inspection · MTSA Verification · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6204690
15 February 2017
DAPI Audit · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6088766
23 August 2016
Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5980652
18 July 2016
Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5963073
16 July 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5967727
29 May 2016
Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5894173
28 May 2016
Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5893043
18 May 2016
Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5880385
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2026
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended.
Steering pump number 2 does not allow the rudders to move back to amidship after being turned to port. Vessel is restricted from carrying passengers until steering control on both pumps operates as required verified by the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2026
Resolution: Conducted a pier side steering test on both pumps and in all steering modes. Test SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 April 2025
Resolved
Spanner wrenches must be provided for each fire hydrant. Fire station #2 is missing a spanner wrench. Replace spanner wrench.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 10 April 2025
Resolution: Spanner wrench was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 April 2025
Resolved
Penetrations in A-Class fire control boundaries for electrical cables must prevent passage of flame and smoke for one hour. Aft tank/steering pump void, on aft bulkhead, has two penetrations on port and two penetrations on starboard side needing sealant. Seal all penetrations, four total.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 10 April 2025
Resolution: Fire stop was applied to all cable thru bulkhead penetrations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2025
Resolved
Electrical equipment must protect passengers, crew, and other persons, and vessel from electrical hazards. Chest refer in bar area appliance cord end is missing ground prong. Replace cord end.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 10 April 2025
Resolution: Plug end of refer appliance cord was replaced with proper ground prong present.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 April 2023
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel has sustained bow and railing damage after an allision with Chicago Lock wall. Vessel may transit from Michigan Ave to Ogden Slip with crew only in order to further assess damage. Vessel is restricted from operations with passengers until assessment and repairs are conducted to the satisfaction of local OCMI.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 April 2023
Resolution: Vessel has made repairs to the satisfaction of attending Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 April 2023
Resolved
The #2 void space is being used as a storage space (High Risk Service Space, type 9), however, the fire control plan shows it as an Auxiliary Machinery, void space (type 12). Either discontinue use as a storage space or change the fire control plan and ensure proper structural fire protection is provided for the space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2023
Resolved 2 May 2023
Resolution: POC provided photos of removal of all stored items from the space. A sign will also be posted indicating the space shall not be used for stores.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2021
Resolved
Vessel fire detection system was not operational during attempted In-Service Inspection. Make repairs and test fire detection system to the satisfaction of Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Vessel was able to find faulty detector in loop system and make repairs, system reset, system tested to satisfaction of Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 March 2020
Resolved
USCG Marine Inspector must complete an onsite inspection of life saving equipment, fire fighting equipment, and navigation equipment. USCG MI must witness satisfactory drills and perform a complete deck walk of all compartments. USCG MI must witness proper operation of the fire and bilge pumps. Due date is 90 days from the date of issue of this requirement. This deficiency will not be used to make risk-based decisions.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 July 2020
Resolved 4 June 2020
Resolution: Tier 2 Level Annual Inspection drills and deck walk through were completed to the satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 March 2019
Resolved
Replace 25 life jackets
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 March 2019
Resolved 22 March 2019
Resolution: Replace 25 jackets. Labled and put into service
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 March 2019
Resolved
add support cable brackets for new CAT Cable install
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 April 2019
Resolved 22 March 2019
Resolution: correct on the spot
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2019
Resolved
Secure Galley CO2 bottles for beverage system
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 22 March 2019
Resolved 22 March 2019
Resolution: secured bottles
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2019
Resolved
Lable circut breakers
Action required: 10 - Deficiency Rectified
Due 22 March 2019
Resolved 22 March 2019
Resolution: labeled breakers
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 22 March 2019
Resolved
Update AIS IAW 33 CFR 164.46(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2019
Resolved 2 May 2019
Resolution: Verified AIS is working
Documentation › Certificates/Documents › Stability Letter
Issued 11 June 2018
Resolved
Stability letter has not been issued to vessel. Stability test data and stability calculation are being reviewed by the Marine Safety Center. Once received, post stability letter at the operating station.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: New Stability letter issued
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 June 2018
Resolved
Life jackets were not available for inspection, verification of stowage/safety plan following vessel modification. Each life jacket must be on-board for inspection and properly marked, stowed, and verified with the safety plan.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: All lifejackets on the vessel, properly marked and stored IAW safety plan
Communications › Public Address System › Announcing Station
Issued 11 June 2018
Resolved
Unable to demonstrate operation of public address system. System was not installed during vessels modification. In the presence of a CG MI, verify operation of public address system.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: Tested public address thru-out vessel
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 June 2018
Resolved
Stern light is inoperable. In the presence of a CG MI, verify operation of Stern Light
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: Stern light working properly.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 April 2017
Resolved
Due to weather Fire drill and MOB drill needs to still be conducted/witnessed by USCG Marine Inpectors.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 13 April 2017
Resolution: Witnessed completion of fire drill and MOB drill. ALL SAT.
Electrical › Electric Generation Source (service) › Generator
Issued 18 July 2016
Resolved
Trouble shoot and make repairs to STBD generator. Conduct load test of Gen for 30 mins prior to carrying passengers to the satisfaction of attending CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2016
Resolved 18 July 2016
Resolution: Found lose wire connection on oil pressure sending unit. tighten connection and test ran Gen with as much load as possible for 35 mins with no issues
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 May 2016
Resolved
Repair damage canopy rail on STBD aft corner. 46 CFR 2.01-10(e)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 16 June 2016
Resolution: replaced or repaired all locking pins on canopy frame
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 May 2016
Resolved
Replace 92 Adult and 4 Children life jackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016
Resolved 18 May 2016
Resolution: purchased 92 adult and 4 childs jackets. Marked and placed them on the vessel.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 May 2016
Resolved
Repair anchor light
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 May 2016
Resolution: Installed new Light