STAR OF CHICAGO

STAR OF CHICAGO is a 1999 passenger vessel (inspected). The Coast Guard has recorded 68 inspections since 1999, most recently in May 2026, along with 62 deficiencies and 6 casualty investigations between 2007 and 2018.

Records from 1999 to 2026. Most recent: inspection, 11 May 2026.

Built
1999
Last inspected
11 May 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ2384
492446
Flag
UNITED STATES
367396720
Maury page id
psix-492446

Inspections, by type

…with no type recorded10
Years with a record 26 calendar years (1999–2026)
The 68 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)84.5 ft × 22.0 ft × 7.3 ft
Registered tonnagegross 94 / net 64
ITC dimensions (L × B × D)84.5 ft × 22.0 ft × 7.3 ft
ITC tonnagegross 98 / net 57
BuilderBLOUNT INDUSTRIES INC · WARREN, RI, UNITED STATES · built 1999
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHICAGO, IL
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it57 - Convention (Subpart B), Net Ton
64 - Regulatory (Subpart C or D), Net Ton
98 - Convention (Subpart B), Gross Ton
94 - Regulatory (Subpart C or D), Gross Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ2384MMSI 367396720 · active · compulsorily equipped · granted 27 March 2019, expires 5 May 2029
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 68

11 May 2026 Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8370674
3 April 2026 MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8341421
20 November 2025 Plan Review "T" Boat
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8285071
28 May 2025 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8145977
3 April 2025 Deficiency Check · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 8104333
22 July 2024 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7963880
17 July 2024 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7960996
2 April 2024 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7888499
4 October 2023 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7803414
10 August 2023 Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7765707
2 May 2023 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7680756
14 April 2023 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7668948
4 April 2023 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7662073
24 October 2022 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7582895
25 March 2022 COI Inspection · MTSA Verification
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7411526
7 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7249397
10 June 2021 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7221327
25 March 2021 DAPI Audit · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7162483
25 March 2021 Plan Review (Other than "T") · Examination of Repairs
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7379560
14 January 2021 Construction Oversight
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 7124592
31 March 2020 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6940481
26 March 2020 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6935795
2 May 2019 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6683660
22 March 2019 DAPI Audit · MTSA Verification · Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6657884
5 September 2018 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6537704
26 June 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6456253
14 June 2018 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6443826
24 October 2017 Construction Oversight · Annual Inspection · Internal Structural Exam · Inclining Experiment · Examination of Repairs · Drydock Exam · Hull Examination · Deficiency Check · Administrative Inspection · Deadweight Survey
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 6294102
10 July 2017 Re-Inspection · MTSA Verification · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6204690
15 February 2017 DAPI Audit · MTSA/ISPS Verification · COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 6088766
23 August 2016 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5980652
18 July 2016 Examination of Repairs · Administrative Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5963073
16 July 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5967727
29 May 2016 Damage Survey
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5894173
28 May 2016 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5893043
18 May 2016 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 5880385
21 October 2015 Internal Structural Exam · Drydock Exam · Examination of Repairs · Deadweight Survey · Construction Oversight
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 5748470
21 June 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4351237
14 June 2012 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4347471
23 January 2012 Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4230221
10 August 2011 In-Service Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 4116140
27 October 2010 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3878739
14 April 2009 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3452177
15 October 2008 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3345385
8 October 2008 Internal Structural Exam · Drydock Exam
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3337889
26 October 2007 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3087584
20 September 2007 COI Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 3054329
24 April 2007 Administrative Inspection
Administrative · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2914639
11 January 2007 Type not recorded
No type recorded · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2857288
25 September 2006 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2772914
7 November 2005 Deficiency Check
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2529885
13 October 2005 Annual Inspection
Physical examination · Marine Safety Unit Chicago · USCG Great Lakes District (CGD-GL) · Activity 2513410
6 October 2004 Deficiency Check · Annual Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2213802
4 August 2004 MTSA Verification
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 2155835
18 December 2003 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1970978
13 October 2003 Hull Examination
Physical examination · Marine Safety Unit Sturgeon Bay · USCG Great Lakes District (CGD-GL) · Activity 1920763
18 September 2003 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1905332
10 October 2002 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1683869
9 October 2001 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1418982
25 October 2000 Re-Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1466725
8 July 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1059075
5 June 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 716655
2 June 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1472365
6 April 2000 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1365708
21 October 1999 COI Inspection
Physical examination · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1437626
27 May 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1455720
17 May 1999 Initial Certification · Inclining Experiment · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1460352
30 March 1999 Type not recorded
No type recorded · MSO CHICAGO · USCG Great Lakes District (CGD-GL) · Activity 1440169

Deficiency record · 62

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 11 May 2026 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Steering pump number 2 does not allow the rudders to move back to amidship after being turned to port. Vessel is restricted from carrying passengers until steering control on both pumps operates as required verified by the attending Marine Inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 12 May 2026
Resolution: Conducted a pier side steering test on both pumps and in all steering modes. Test SAT.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 3 April 2025 Resolved
Spanner wrenches must be provided for each fire hydrant. Fire station #2 is missing a spanner wrench. Replace spanner wrench.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 10 April 2025
Resolution: Spanner wrench was replaced.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 3 April 2025 Resolved
Penetrations in A-Class fire control boundaries for electrical cables must prevent passage of flame and smoke for one hour. Aft tank/steering pump void, on aft bulkhead, has two penetrations on port and two penetrations on starboard side needing sealant. Seal all penetrations, four total.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 10 April 2025
Resolution: Fire stop was applied to all cable thru bulkhead penetrations.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 3 April 2025 Resolved
Electrical equipment must protect passengers, crew, and other persons, and vessel from electrical hazards. Chest refer in bar area appliance cord end is missing ground prong. Replace cord end.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 April 2025
Resolved 10 April 2025
Resolution: Plug end of refer appliance cord was replaced with proper ground prong present.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 14 April 2023 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Vessel has sustained bow and railing damage after an allision with Chicago Lock wall. Vessel may transit from Michigan Ave to Ogden Slip with crew only in order to further assess damage. Vessel is restricted from operations with passengers until assessment and repairs are conducted to the satisfaction of local OCMI.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 April 2023
Resolution: Vessel has made repairs to the satisfaction of attending Marine Inspectors.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 4 April 2023 Resolved
The #2 void space is being used as a storage space (High Risk Service Space, type 9), however, the fire control plan shows it as an Auxiliary Machinery, void space (type 12). Either discontinue use as a storage space or change the fire control plan and ensure proper structural fire protection is provided for the space.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2023
Resolved 2 May 2023
Resolution: POC provided photos of removal of all stored items from the space. A sign will also be posted indicating the space shall not be used for stores.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 10 June 2021 Resolved
Vessel fire detection system was not operational during attempted In-Service Inspection. Make repairs and test fire detection system to the satisfaction of Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 10 June 2021
Resolution: Vessel was able to find faulty detector in loop system and make repairs, system reset, system tested to satisfaction of Marine Inspector.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 31 March 2020 Resolved
USCG Marine Inspector must complete an onsite inspection of life saving equipment, fire fighting equipment, and navigation equipment. USCG MI must witness satisfactory drills and perform a complete deck walk of all compartments. USCG MI must witness proper operation of the fire and bilge pumps. Due date is 90 days from the date of issue of this requirement. This deficiency will not be used to make risk-based decisions.
Condition: Invalid
Action required: 705 - Other - as specified
Due 31 July 2020
Resolved 4 June 2020
Resolution: Tier 2 Level Annual Inspection drills and deck walk through were completed to the satisfaction of attending Marine Inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 22 March 2019 Resolved
Replace 25 life jackets
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 22 March 2019
Resolved 22 March 2019
Resolution: Replace 25 jackets. Labled and put into service
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 22 March 2019 Resolved
add support cable brackets for new CAT Cable install
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 8 April 2019
Resolved 22 March 2019
Resolution: correct on the spot
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 22 March 2019 Resolved
Secure Galley CO2 bottles for beverage system
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 22 March 2019
Resolved 22 March 2019
Resolution: secured bottles
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 22 March 2019 Resolved
Lable circut breakers
Action required: 10 - Deficiency Rectified
Due 22 March 2019
Resolved 22 March 2019
Resolution: labeled breakers
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 22 March 2019 Resolved
Update AIS IAW 33 CFR 164.46(d)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 22 March 2019
Resolved 2 May 2019
Resolution: Verified AIS is working
Documentation › Certificates/Documents › Stability Letter
Issued 11 June 2018 Resolved
Stability letter has not been issued to vessel. Stability test data and stability calculation are being reviewed by the Marine Safety Center. Once received, post stability letter at the operating station.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: New Stability letter issued
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 11 June 2018 Resolved
Life jackets were not available for inspection, verification of stowage/safety plan following vessel modification. Each life jacket must be on-board for inspection and properly marked, stowed, and verified with the safety plan.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: All lifejackets on the vessel, properly marked and stored IAW safety plan
Communications › Public Address System › Announcing Station
Issued 11 June 2018 Resolved
Unable to demonstrate operation of public address system. System was not installed during vessels modification. In the presence of a CG MI, verify operation of public address system.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: Tested public address thru-out vessel
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 11 June 2018 Resolved
Stern light is inoperable. In the presence of a CG MI, verify operation of Stern Light
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 26 June 2018
Resolution: Stern light working properly.
Operations/Management › Drills/Instruction › Not Conducted
Issued 6 April 2017 Resolved
Due to weather Fire drill and MOB drill needs to still be conducted/witnessed by USCG Marine Inpectors.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 13 April 2017
Resolution: Witnessed completion of fire drill and MOB drill. ALL SAT.
Electrical › Electric Generation Source (service) › Generator
Issued 18 July 2016 Resolved
Trouble shoot and make repairs to STBD generator. Conduct load test of Gen for 30 mins prior to carrying passengers to the satisfaction of attending CG inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 23 July 2016
Resolved 18 July 2016
Resolution: Found lose wire connection on oil pressure sending unit. tighten connection and test ran Gen with as much load as possible for 35 mins with no issues
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 29 May 2016 Resolved
Repair damage canopy rail on STBD aft corner. 46 CFR 2.01-10(e)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 29 June 2016
Resolved 16 June 2016
Resolution: replaced or repaired all locking pins on canopy frame
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 May 2016 Resolved
Replace 92 Adult and 4 Children life jackets.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 18 May 2016
Resolved 18 May 2016
Resolution: purchased 92 adult and 4 childs jackets. Marked and placed them on the vessel.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 18 May 2016 Resolved
Repair anchor light
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 May 2016
Resolved 18 May 2016
Resolution: Installed new Light
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Gear, Timing
Issued 4 April 2016 Resolved
Test new Kohler gensets under full load & repair coolant leaks to satisfaction of attending CG marine inspector. 46 CFR 182.220 DUE: Prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2016
Resolved 18 May 2016
Resolution: Generator tested under load. found no coolent leaks in system
Engineering › Steering Gear System › Rudder
Issued 4 April 2016 Resolved
Conduct sea trails to the satisfaction of attending CG marine inspector (rudders, shafts, props were all overhauled). 46 CFR 182.220 DUE: Prior to carrying passengers for hire.
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 August 2016
Resolved 18 May 2016
Resolution: Got underway with vessel to conduct drills. Tested engines. all sat.
Electrical › Electrical Distribution System (service) › Wiring
Issued 4 April 2016 Resolved
Repack electrical runs in fwd closet.
Due 4 May 2016
Resolved 18 May 2016
Resolution: All cable in proper cable runs.
Engineering › Bilge Water Management System › Interface Detector
Issued 27 October 2010 Resolved
Audible Bilge Alarm indicator in pilot house was not working.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 10 November 2010
Resolved 28 October 2010
Resolution: Audible bilge alarm was silenced and crew did not know how to operate controls. Shoreline engineers placed audible bilge alarm back into normal operation.
Communications › Alarms/Indicators › Bilge Alarm
Issued 15 October 2008 Resolved
Provide bilge high level alarm IAW 46 CFR 182.530 (c) and 46 CFR 182.115(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 November 2008
Resolved 14 April 2009
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 20 September 2007 Resolved
Replace emergency instruction list on lower deck stbd side, outboard of bar IAW 46 CFR 185.510
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 26 October 2007
Resolution: Emergency instruction list on lower level replaced with new.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 20 September 2007 Resolved
Renew hatch gasket on all deck hatches IAW 46 CFR 171.124.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 October 2007
Resolved 26 October 2007
Resolution: Deck hatch gaskets replaced and water tested for leaks. All Sat
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 25 September 2006 Resolved
Properly label main AC circuit breaker in forward storage compartment IAW 46CFR120.220(d)
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2006
Resolved 25 October 2006
Communications › Alarms/Indicators › Bilge Alarm
Issued 25 September 2006 Resolved
Install audio bilge high level indicator alarm IAW 46CFR119.530.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2006
Resolved 25 October 2006
Communications › Alarms/Indicators › Lube Oil Low Pressure Alarm
Issued 25 September 2006 Resolved
Demonstrate proper operation of low lube oil pressure and high temperature alarms on both MDEs and both generators IAW 46CFR119.220.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2006
Resolved 25 October 2006
Stability › Watertight Integrity › General
Issued 25 September 2006 Resolved
Make bulkhead penetrations between void under forward cargo hold and tank compartment watertight IAW 46CFR171.010.
Condition: Unknown
Action required: 705 - Other - as specified
Due 25 October 2006
Resolved 25 October 2006
Navigation › Collision/Grounding Avoidance › Radar
Issued 25 September 2006 Resolved
Vessel missing radar as per 46 CFR 121.404.
Condition: Unknown
Due 26 October 2006
Resolved 25 October 2006
Construction/Loadline › Structures › Superstructure
Issued 25 September 2006 Resolved
Canopy installation must be IAW MSC letter dated May 6, 1999. Sides of canopy are not permitted. In addition, canvas may not enclose the main or upper deck passenger spaces as per MSC letter May 6, 1999.
Condition: Improper Installation
Due 26 October 2006
Resolved 25 October 2006
Resolution: Cleared as canopy has been removed for season. Added special note to monitor situation during operating season.
Fire Fighting › Structural Fire Protection - General › Structural Bulkhead Construction
Issued 25 September 2006 Resolved
Must provide means to secure ventilation to pantry space IAW 46 CFR 116.415 (a)(2)(ii). The means to accomplish this must be IAW with same regulation.
Condition: Placed in Improper Service
Due 29 September 2006
Resolved 25 October 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 13 October 2005 Resolved
Put contents of First Aid kit 46 CFR 121.710
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 2 November 2005
Resolution: purchased new CG approved first aid kit.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 13 October 2005 Resolved
Repair or replace Insulation on overhead above STBD Engine. 46 CFR 116.415
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 2 November 2005
Resolution: Shoreline contracted a company to repair/replace Insulation in engine room. Inspected and found to be SAT.
Accommodation/Occupational Safety › Ventilation › General
Issued 13 October 2005 Resolved
Repair or replace exhaust fan in female head 46 CFR 116.600
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 2 November 2005
Resolution: Installed new fan motor.
Fire Fighting › Combustible Materials › Paints/Varnishes/Other Finishes
Issued 13 October 2005 Resolved
Remove combustibles from vessel or provide an approved flammable storage locker 46 CFR 116.405
Action required: 705 - Other - as specified
Due 14 November 2005
Resolved 2 November 2005
Resolution: All combustibles have been removed to shore side work station.
Lifesaving › Lifebuoys › Serviceable
Issued 6 October 2004 Resolved
Life ring was cracked and badly worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 5 November 2004
Resolution: Replaced all Liferings
Fire Fighting › Miscellaneous Items › Waste Receptacles
Issued 6 October 2004 Resolved
waste recepticals made out of plastic needed to have metel liners.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 5 November 2004
Resolution: Removed all combustable recepticales off the ship.
Communications › Radio Communications › EPIRB
Issued 6 October 2004 Resolved
EPIRB needs to be registered to NOAA
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 8 November 2004
Resolved 5 November 2004
Resolution: Removed EPIRB
Pollution Prevention/Response › Prevention Equipment
Issued 10 October 2002 Resolved
Make repairs to port sewage tank cover. Clean and sanitize bilge. LEGACY COMPONENT DESC: Marine Sanitation Device, Type III
Condition: Improper/Lack of Maintenance
Due 10 November 2002
Resolved 22 October 2002
Resolution: Cleared upon receipt of affadavit from o/o
Electrical › Lighting (emergency)
Issued 10 October 2002 Resolved
Replace 110 v light bulbs with 12 v light bulbs in lazarette & sewage room as required LEGACY COMPONENT DESC: Lighting Fixture
Condition: Placed in Improper Service
Due 10 November 2002
Resolved 22 October 2002
Resolution: Cleared upon receipt of affadavit from o/o
Navigation › Piloting/Steering
Issued 10 October 2002 Resolved
Prove purchase of current pubs & charts LEGACY COMPONENT DESC: US Coast Pilot
Due 10 November 2002
Resolved 22 October 2002
Resolution: Cleared upon receipt of affadavit from o/o
Electrical
Issued 25 October 2000 Resolved
REPLACE BULB ON EMERGENCY ENGINE SHUT DOWN INDICATOR IN PILOT HOUSE.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Electrical
Issued 25 October 2000 Resolved
PROVE PROPER OPERATION OF FWD AND PORT EMERGENCY LIGHTS.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Documentation
Issued 25 October 2000 Resolved
POST STABILITY LETTER IN ACCORDANCE WITH 46 CFR 115.306.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Engineering
Issued 25 October 2000 Resolved
REPLACE HOSE CLAMP ON COOLANT HOSE AT CAP ON STARBOARD ENGINE.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Documentation
Issued 25 October 2000 Resolved
PROVIDE PROOF OF PURCHASE OF 46 CFR 90-139.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Construction/Loadline
Issued 25 October 2000 Resolved
PROVE PROPER OPERATION OF BILGE HIGH LEVEL ALARMS.
Condition: Unknown
Due 25 October 2000
Resolved 25 October 2000
Lifesaving
Issued 2 June 2000 Resolved
Provide qualified personnel that are capable of assuming duties as an unlicensed engineer in accordance with vessels COI.
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Lifesaving
Issued 2 June 2000 Resolved
Provide qualified personnel that are capable of assuming routine deckhand duties._x001C_
Condition: Unknown
Due 5 June 2000
Resolved 5 June 2000
Lifesaving
Issued 6 April 2000 Resolved
Prior to the carriage of passengers, ensure all life rings are equipped with retro-reflective tape and name of vessel, to the satisfaction of the attending marine inspector.
Condition: Unknown
Due 15 April 2000
Resolved 11 April 2000
Fire Fighting
Issued 6 April 2000 Resolved
Prior to the carriage of passengers, ensure vessel's fixed fire fighting system has been properly serviced and tested in accordance with 46 CFR 115.810, and provide proof of the same to the satisfaction of the attendingmarine inspector.
Condition: Unknown
Due 15 April 2000
Resolved 11 April 2000
Fire Fighting
Issued 21 October 1999 Resolved
PROVIDE PLAN OR PROPSAL FOR THE INSTALLATION OF AUTOMATIC FIRE DAMPERS FOR THE ENGINE ROOM VENTILATION DUCTS IN ACCORDANCE WITH 46 CFR 116.610(f)(7), TO THE SATSIFACTION OF THE ATTENDING MARINE INSPECTOR & THE COGNIZANT OCMI.
Condition: Unknown
Due 1 November 1999
Resolved 4 November 1999
Unknown
Issued 17 May 1999 Resolved
PROVIDE ALL REQUIRED LOGS, PUBS AND RECORDS PRIOR TO ALLOWING PASSENGERS.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Unknown
Issued 17 May 1999 Resolved
PROVIDE AND POST VESSEL'S STABILITY LETTER ONBOARD PRIOR TO ALLOWING PASSENGERS.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Unknown
Issued 17 May 1999 Resolved
PROVIDE PERMANENT LABELS FOR ALL BILGE SYSTEM VALVES.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Unknown
Issued 17 May 1999 Resolved
INSTALL AND TEST PA SYSTEM PRIOR TO ALLOWING PASSENGERS.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999
Unknown
Issued 17 May 1999 Resolved
CONDUCT U/W FIRE AND MAN OVERBOARD DRILLS IN PRESENCE OF CG MARINE INSPECTOR PRIOR TO ALLOWING PASSENGERS.
Condition: Unknown
Due 17 November 1999
Resolved 17 November 1999

Casualty record · 6

11 January 2007Routine · role: Involved in a Marine Casualty · activity 2857288
1 July 2010Routine · role: Involved in a Marine Casualty · activity 3790092
1 May 2011Routine · role: Involved in a Marine Casualty · activity 4052232
28 May 2016Routine · role: Involved in a Marine Casualty · 2 injured · at ADAMS ST. BRIDGE · activity 5893043
16 July 2016Routine · role: Involved in a Marine Casualty · activity 5967727
5 September 2018Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 6537704
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.