MAURY USCG vessel records Sign in
← All vessels

SEA QUEEN II

SEA QUEEN II is a 1977 passenger vessel (inspected). The Coast Guard has recorded 90 inspections since 1985, most recently in June 2026, along with 92 deficiencies and 6 casualty investigations between 2006 and 2015.

Records from 1985 to 2026. Most recent: inspection, 9 June 2026.

Built
1977
Last inspected
9 June 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ8518
Flag
UNITED STATES
367450640
Maury page id
psix-49247

Inspections, by type

…with no type recorded19
Years with a record 41 calendar years (1985–2026)
The 90 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.4 ft × 20.0 ft × 7.5 ft
Registered tonnagegross 67 / net 45
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY-CRAFT, INC. · LOREAUVILLE LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portHYANNIS, MA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 1 April 2026 · expires 30 April 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it67 - Regulatory (Subpart C or D), Gross Ton
45 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ8518MMSI 367450640 · active · compulsorily equipped · granted 13 May 2020, expires 31 May 2030
WCG8134MMSI not assigned · expired · voluntarily equipped · granted 24 May 1994, cancelled 25 July 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 90

9 June 2026 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8395698
23 April 2026 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8354678
5 May 2025 COI Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 8111417
10 May 2024 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7905974
7 March 2024 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7870263
20 June 2023 Examination of Repairs · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7716441
13 May 2022 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7445224
14 April 2022 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7417116
7 May 2021 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 7193486
29 May 2020 COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6963501
13 May 2020 Drydock Exam · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6944377
11 December 2019 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6872040
29 April 2019 Administrative Inspection · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6670936
21 June 2018 Annual Inspection · Administrative Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6444989
30 March 2018 Examination of Repairs · Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6377215
5 July 2017 Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 6191561
4 May 2016 DAPI Audit · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 5869432
28 March 2016 Drydock Exam · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5839512
7 September 2015 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 5722600
18 June 2014 Administrative Inspection · Annual Inspection · Deficiency Check · DAPI Audit
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4892396
7 June 2014 Administrative Inspection
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4883782
7 June 2014 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4883860
15 June 2012 Annual Inspection · Plan Review "T" Boat
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4348090
5 June 2012 Type not recorded
No type recorded · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4351170
27 September 2011 Plan Review "T" Boat
Administrative · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4155509
19 July 2011 Deficiency Check
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4087333
14 July 2011 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 4081418
29 March 2010 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3702813
27 April 2009 Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3458332
25 April 2008 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 3179583
18 March 2008 Internal Structural Exam · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3158208
10 May 2007 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2914305
21 June 2006 Annual Inspection
Physical examination · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2671193
9 June 2006 Type not recorded
No type recorded · Marine Safety Unit Cape Cod · USCG Northeast District (CGD-NE) · Activity 2695147
17 April 2006 Internal Structural Exam · Hull Examination
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 2613451
27 April 2005 COI Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2343121
12 April 2004 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 2042124
6 April 2004 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 2036295
23 May 2003 Damage Survey
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1799806
19 May 2003 Type not recorded
No type recorded · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1850009
29 April 2003 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1782550
22 April 2002 Re-Inspection
Physical examination · MSFO CAPE COD · USCG Northeast District (CGD-NE) · Activity 1607783
27 February 2002 Hull Examination
Physical examination · MSFO NEW BEDFORD · USCG Northeast District (CGD-NE) · Activity 1489853
1 May 2001 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1063985
19 March 2001 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1068204
27 April 2000 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1469958
30 December 1999 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1442932
16 April 1999 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1120771
8 September 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 54264
24 August 1998 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 164772
13 April 1998 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 789371
25 March 1998 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1122274
9 August 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 18558
29 April 1997 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 783189
3 April 1997 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1102541
9 September 1996 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1261871
7 May 1996 Deficiency Check · Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1089593
1 May 1996 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1089599
7 June 1995 Administrative
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1184096
1 May 1995 Re-Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1189598
7 December 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 660041
7 December 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 660042
6 December 1994 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1140082
8 September 1994 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 142398
6 September 1994 Deficiency Check
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1358517
9 June 1994 COI Inspection
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1178838
23 May 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1170549
29 September 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 649107
9 September 1993 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 99129
10 June 1993 Drydock Extension · Re-Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1146850
8 August 1992 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 113637
11 June 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 955825
11 June 1992 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 962075
20 May 1992 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 954249
3 May 1991 Re-Inspection · Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 925358
11 June 1990 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 907676
2 May 1990 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 927437
19 May 1989 COI Inspection
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 888610
2 May 1989 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1349782
19 July 1988 Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 897079
8 July 1988 Re-Inspection · Deficiency Check
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1208518
2 June 1988 Hull Examination
Physical examination · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 1212043
17 June 1987 Re-Inspection
Physical examination · MIO PHILADELPHIA · USCG East District (CGD-E) · Activity 1337101
6 March 1987 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1025673
10 December 1986 Hull Examination
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1331953
2 September 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1322392
18 June 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 995898
20 May 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 986708
24 July 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 983417
24 June 1985 Type not recorded
No type recorded · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1300051

Deficiency record · 92

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2023 Resolved
Vessel has coolant water leaks on both port and starboard MDE's wet exhaust systems. Make permanent repairs to to all leaks.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 July 2023
Resolution: Received photos of repair
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 20 June 2023 Resolved
During an inspection of the steering void, it was noted that the void is coated in black soot. There is also a strong exhaust odor in the void and viable smoke while the MDEs are running. Identify and repair the MDE exhaust leak in the steering void.
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 25 July 2023
Resolution: Received photo of repair
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 29 April 2019 Resolved
Port side Engine exhaust is leaking. repair or replace exhaust pipe.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2019
Resolved 11 December 2019
Resolution: Exahust was removed, cleaned and welded into place.
11 - Life Saving Appliances › N/A - No Subsystem › Inflatable liferafts
Issued 29 April 2019 Resolved
Install life raft in proper location.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2019
Resolved 11 December 2019
Resolution: Life raft was put back in proper location.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 30 March 2018 Resolved
Void #2 clean and repair protect from corrosion in space as marked.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2018
Resolved 9 April 2018
Resolution: Cleaned and protected surface in bilge to prevent further corrosion / damage.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 30 March 2018 Resolved
Clean remove corrosion and failed coating from bilge in laz.
Condition: Improper Installation
Action required: 17 - Rectify deficiencies prior to departure
Due 30 March 2018
Resolved 9 April 2018
Resolution: Failed coating removed and replaced to prevent further damage.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 18 June 2014 Resolved
Generator exhaust hose from engine to muffler is cracked, replace hose with J2006 water exhaust hose.
Due 2 July 2014
Resolved 22 July 2014
Engineering › Steering Gear System › Hydraulic Hose
Issued 18 June 2014 Resolved
Pump room and engine room hydraulic steering hose (jacket is wasted), replace hose.
Due 18 July 2014
Resolved 22 July 2014
Electrical › Electric Supply System (service) › Battery Installation
Issued 18 June 2014 Resolved
Properly run battery wires located in the engine hanging in the bilge under manifold and strap down the battery to prevent tipping.
Due 18 July 2014
Resolved 22 July 2014
Electrical › Lighting (service) › Lighting Fixture
Issued 18 June 2014 Resolved
Outboard port main engine light fixture is in-operative, prove proper operation or remove light.
Due 18 July 2014
Resolved 22 July 2014
Engineering › Electric Propulsion System › Contactor Circuitry
Issued 18 June 2014 Resolved
Starter solenoid is covered in salt and the terminals are corroded. Clean solenoid and relocate it to protect from corrosion and salt water dripping from above.
Due 18 July 2014
Resolved 22 July 2014
Engineering › Bilge Water Management System › Manifold
Issued 18 June 2014 Resolved
Provide diagram and operating instructions for bilge manifold system, located at the manifold.
Due 18 July 2014
Resolved 22 July 2014
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 18 June 2014 Resolved
Replace both hoses located in the tankroom to the sanitary pump with J2006 hose.
Due 18 July 2014
Resolved 22 July 2014
Pollution Prevention/Response › Prevention Equipment › Oily Mixture Discharge Fixed Piping System
Issued 18 June 2014 Resolved
Both main engine breather hoses are piped overboard, address to prevent potential oil pollution discharge.
Due 18 July 2014
Resolved 22 July 2014
Engineering › Engine Controls (Electric/Electronic) › Linkage
Issued 7 June 2014 Resolved
Make proper repairs to Morse shift cable prior to carrage of passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 7 June 2014
Electrical › Electric Generation Source (service) › Generator
Issued 14 July 2011 Resolved
Master stated ssdg cuts out when running washdown pumps & hydro anchor winch. Can restart immediately. Ensure reliability of ssdg, provide statement of intent to repair or replace.
Action required: 705 - Other - as specified
Due 14 August 2011
Resolved 18 July 2011
Resolution: New generator installed
Engineering › Steering Gear System › Hydraulic Hose
Issued 14 July 2011 Resolved
Hydraulic hoses from steering station to steering compartment hydro ram deteriorated, outer jacket peeled back over 100% of hoses. Replace all deteriorated hydraulic steering hoses.
Action required: 705 - Other - as specified
Due 15 August 2011
Resolved 15 August 2011
Resolution: New hoses installed
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 14 July 2011 Resolved
Salt water supply line, 2" ridgid rubber hose, to flush toilets deteriorated. Hose located aft steering compartment. Replace hose.
Action required: 705 - Other - as specified
Due 15 August 2011
Resolved 18 July 2011
Resolution: S/W hose replaced
Electrical › Lighting (service) › Lighting Fixture
Issued 6 April 2004 Resolved
Engine room port side near the port engine address exposed wiring
Due 7 May 2004
Resolved 12 April 2004
Electrical › Lighting (service) › Conductor
Issued 6 April 2004 Resolved
Port engine remove the dead ended wire.
Due 7 May 2004
Resolved 12 April 2004
Engineering › Bilge Water Management System › Hose
Issued 6 April 2004 Resolved
Double clamp the hoses on the jabsco pump in the front of the stbd engine. (also check the belt alignment, it appears that it is rubbing)
Condition: Improper Installation
Due 7 May 2004
Resolved 12 April 2004
Electrical › Lighting (service) › Lighting Feeder
Issued 6 April 2004 Resolved
Address the wire connections that are exposed and not properly connected.
Due 7 May 2004
Resolved 12 April 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 6 April 2004 Resolved
Address the wiring in the main cabin area that is exposed
Due 7 May 2004
Resolved 12 April 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 22 April 2002 Resolved
PLACE LIFE JACKETS REMOVED FROM VESSEL DUE TO REDUCTION OF PASSENGER COUNT BACK ON VESSEL FOR WARM WATER MONTHS OPERATIONS.
Condition: Unknown
Action required: 705 - Other - as specified
Due 29 April 2002
Resolved 22 April 2002
Resolution: TOTAL LIFE JACKETS 101.
Lifesaving › Inflatable Liferafts › Hydrostatic Release Unit
Issued 22 April 2002 Resolved
REPLACE HYDROSTATIC FOR IBA.
Condition: Unknown
Action required: 705 - Other - as specified
Due 26 April 2002
Resolved 22 April 2002
Resolution: HYDRO REPLACED.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 April 2002 Resolved
INSTALL RETROREFLECTIVE TAPE AS REQUIRED ON BOTH RINGS.
Action required: 705 - Other - as specified
Due 26 April 2002
Resolved 22 April 2002
Resolution: RETRO TAPE INSTALLED.
Electrical › Electric Supply System (service) › Cable
Issued 22 April 2002 Resolved
REPLACE WIRE NUTS WITH COMPRESSION FITTINGS AND INSTALL JUNCTION BOX COVER IN AFT PASSENGER COMPARTMENT VOID.
Action required: 705 - Other - as specified
Due 26 April 2002
Resolved 22 April 2002
Resolution: ALL REPLACED SAT.
Construction/Loadline › Structures
Issued 27 February 2002 Resolved
De-water forepeak for inspection LEGACY COMPONENT DESC: Forepeak
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 22 April 2002
Construction/Loadline › Structures
Issued 27 February 2002 Resolved
Clean coamings and attach retaining cables for all hatches LEGACY COMPONENT DESC: Watertight hatch
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 22 April 2002
Construction/Loadline › Hull
Issued 27 February 2002 Resolved
Repair tripped welds, #2 void, starboard side, 1st frame, 5th stiffener LEGACY COMPONENT DESC: Stiffener
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 22 April 2002
Engineering › Bilge Water Management System
Issued 27 February 2002 Resolved
Provide bilge strainers that are 3x the pipe diameter in all compartments LEGACY COMPONENT DESC: Strainer
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 4 April 2002
Resolved 22 April 2002
Electrical › Lighting (service)
Issued 27 February 2002 Resolved
Provide globe for light fixture in lazarette LEGACY COMPONENT DESC: Lighting Fixture
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 22 April 2002
Accommodation/Occupational Safety
Issued 27 February 2002 Resolved
Repair broken window in accommodation space, portside LEGACY COMPONENT DESC: Window
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 22 April 2002
Engineering › Freshwater System (jacketwater cooling)
Issued 27 February 2002 Resolved
Make permanent repair to starboard engine cooling line LEGACY COMPONENT DESC: Piping
Condition: Unknown
Action required: 705 - Other - as specified
Due 27 March 2002
Resolved 22 April 2002
Resolution: Vessel converted to raw water cooling and keel cooler lines removed.
Construction/Loadline › Hull
Issued 27 February 2002 Resolved
Submit plans for repairs to bottom plating in areas of metal delamination in #3 void, engine room, and lazarette LEGACY COMPONENT DESC: Bottom Plating
Condition: Unknown
Action required: 705 - Other - as specified
Due 28 March 2002
Resolved 22 April 2002
Resolution: See drydock case.
Construction/Loadline
Issued 3 April 1997 Resolved
RENEW DETERIORATED SECTIONS OF STEEL BILGE PIPING IN FOREPEAK AND AFTER STEERING COMPARTMENT.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Documentation
Issued 3 April 1997 Resolved
CONDUCT A DRUG AUDIT OF VESSEL'S CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Lifesaving
Issued 3 April 1997 Resolved
REPAIR WATERLIGHT FOR ONE OF THE 15 PERSON LIFE FLOATS.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Lifesaving
Issued 3 April 1997 Resolved
PROVIDE 6 ADDITIONAL ADULT LIFE PRESERVERS.
Condition: Unknown
Due 3 April 1997
Resolved 3 April 1997
Electrical
Issued 7 May 1996 Resolved
LABEL 110V ELECTRICAL PANEL BREAKERS.
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Engineering
Issued 7 May 1996 Resolved
REPAIR LUBE OIL LEAK, GENERATOR.
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Construction/Loadline
Issued 7 May 1996 Resolved
PROVIDE STRAINER FOR BILGE SUCTION IN PASSENGER COMPARTMENT VOID.
Condition: Unknown
Due 26 August 1996
Resolved 26 August 1996
Documentation
Issued 7 May 1996 Resolved
CONDUCT AUDIT OF CHEMICAL TESTING PROGRAM.
Condition: Unknown
Due 7 May 1996
Resolved 7 May 1996
Lifesaving
Issued 1 May 1995 Resolved
PROVIDE 9 ADULT AND 2 CHILD LIFE PRESERVERS, VESSEL IS LIMITED TO 76 TOTAL PERSONS UNTIL THE ABOVE IS COMPLETED.
Condition: Unknown
Due 1 June 1995
Resolved 24 July 1995
Engineering
Issued 1 May 1995 Resolved
INSTALL A GUARD ON THE PORT MAIN ENGINE.
Condition: Unknown
Due 1 June 1995
Resolved 24 July 1995
Electrical
Issued 6 December 1994 Resolved
MAKE PERMANENT REPAIR TO VESSEL'S ELECTRICAL NAVIGATIONAL/INTERIOR LIGHTINGDC PANEL AND DEMONSTRATE PROPER OPERATION PRIOR TO CARRYING PASSENGERS FOR HIRE.
Condition: Unknown
Due 15 December 1994
Resolved 19 December 1994
Electrical
Issued 6 December 1994 Resolved
CONDUCT PROPER OPERATION OF 110 AC SHIP SERVICE GENERATOR PRIOR TO OPERATING.
Condition: Unknown
Due 15 December 1994
Resolved 19 December 1994
Navigation
Issued 6 December 1994 Resolved
MAKE PROPER REPAIRS TO VESSEL'S NAVIGATIOAL MAGNETIC COMPASS PRIOR TO OPERATING.
Condition: Unknown
Due 15 December 1994
Resolved 19 December 1994
Engineering
Issued 6 September 1994 Resolved
PROVE PROPER OPERATION OF THE PROPULSION ENGINES AND REQUIRED SYSTEMS. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TOCARRYING PASSENGERS.
Condition: Unknown
Due 15 September 1994
Resolved 16 September 1994
Engineering
Issued 6 September 1994 Resolved
SUBMIT PLANS FOR APPROVAL ILLUSTRATING ALL WORK ASSOCIATED WITH RE-ENGININGTHE VESSEL. TO BE COMPLETED TO THE SATISFACTION OF THE ATTENDING MARINE INSPECTOR PRIOR TO CARRYING PASSENGERS.
Condition: Unknown
Due 15 September 1994
Resolved 16 September 1994
Construction/Loadline
Issued 6 September 1994 Resolved
CAP BALL VALVE UNDER THE HOLDING TANK IN THE LAZARETTE SPACE
Condition: Unknown
Due 20 September 1994
Resolved 27 September 1994
Engineering
Issued 6 September 1994 Resolved
REPAIR LEAK IN THE PORT SURGE TANK IN THE ENGINE ROOM
Condition: Unknown
Due 20 September 1994
Resolved 27 September 1994
Electrical
Issued 6 September 1994 Resolved
INSTALL MISSING BREAKER IN THE BREAKER BOX FORWARD BULKHEAD LAZARETTE SPACE.
Condition: Unknown
Due 20 September 1994
Resolved 27 September 1994
Fire Fighting
Issued 6 September 1994 Resolved
REPAIR LEAK IN FIRE MAIN PIPING IN THE ENGINE ROOM STBD SIDE FORWARD.
Condition: Unknown
Due 20 September 1994
Resolved 27 September 1994
Documentation
Issued 9 June 1994 Resolved
OBTAIN FCC RADIO SAFETY CERTIFICATE AND POST.
Condition: Unknown
Due 9 July 1994
Resolved 6 September 1994
Lifesaving
Issued 9 June 1994 Resolved
CONDUCT FIRE AND BOAT DRILLS
Condition: Unknown
Due 9 July 1994
Resolved 6 September 1994
Documentation
Issued 9 June 1994 Resolved
PROVIDE DOCUMENTATION THAT VESSEL'S CREW IS ENROLLED IN A DRUG TESTING PROGRAM.
Condition: Unknown
Due 9 June 1994
Resolved 9 June 1994
Lifesaving
Issued 10 June 1993 Resolved
PROVIDE 4 ADULT AND 1 CHILD PFD ONBOARD. THE NUMBER OF PASSENGERS IS REDUCED TO 80 UNTIL THIS ITEM IS CORRECTED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Navigation
Issued 10 June 1993 Resolved
PROVIDE A CURRENT EDITION OF INLAND NAVIGATION RULES ON BOARD._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Lifesaving
Issued 10 June 1993 Resolved
RENEW THE LIFEFLOAT SEA PAINTER AND THE LINE WHICH ATTACHS THE THREE LIFEFLOATS TOGETHER._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Accommodation/Occupational Safety
Issued 10 June 1993 Resolved
DEMONSTRATE THE OPERATION OF THE NEW TOILETS ONCE INSTALLED._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Documentation
Issued 11 June 1992 Resolved
PROVIDE DOCUMENTATION THAT ALL FCC CERTIFICATES AND LICENSES HAVE BEEN ISSUED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Lifesaving
Issued 11 June 1992 Resolved
PROVIDE 3 ADDITIONAL SMOKE FLARES_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Lifesaving
Issued 11 June 1992 Resolved
PROVIDE 6 ADDITIONAL ADULT SIZED PFD'S OF AN APPROVED TYPE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 19 August 1992
Resolved 19 August 1992
Documentation
Issued 11 June 1992 Resolved
PROVIDE DOCUMENTATION THAT ALL FCC CERTIFICATES AND LICENSES HAVE BEEN RENEWED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Lifesaving
Issued 11 June 1992 Resolved
PROVIDE SIX ADDITIONAL ADULT SIZED PFD'S OF AN APPROVED TYPE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Lifesaving
Issued 11 June 1992 Resolved
PROVIDE 3 ADDITIONAL SMOKE FLARES_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 29 October 1992
Resolved 29 October 1992
Lifesaving
Issued 3 May 1991 Resolved
REPLACE RING LIFEBOUY PRIOR TO CARRIAGE OF PASSENGERS FOR HIRE, BUT NOT LATER THAN 5JUL91.
Condition: Unknown
Due 8 July 1991
Resolved 8 July 1991
Lifesaving
Issued 3 May 1991 Resolved
REPAIR/REPLACE 10 ADULT PFD'S PRIOR TO CARRIAGE OF MORE THAN 75 PERSONS BUTNOT LATER THAN 5JUL91.
Condition: Unknown
Due 8 July 1991
Resolved 8 July 1991
Documentation
Issued 3 May 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 8 July 1991
Resolved 8 July 1991
Engineering
Issued 11 June 1990 Resolved
PROVIDE HEAT DEFLECTOR SHIELDS FOR (3) RACOR FUEL FILTERS WHERE MISSING.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Lifesaving
Issued 11 June 1990 Resolved
PROVIDE (1) ADULT AND (1) CHILD SIZE PFD WHERE MISSING.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Navigation
Issued 11 June 1990 Resolved
PROVIDE THE VESSEL WITH 2 MILE SIDES,3 MILE MAST LIGHT, AND A 2 MILE STERN LIGHT AS REQUIRED BY INLAND RULES OF THE ROAD,THE VESSEL IS RESTRICTED TO DAY LIGHT OPERATIONS UNTIL THIS REQUIREMENT IS SATISFIED.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Lifesaving
Issued 11 June 1990 Resolved
PROVIDE A BRACKET FOR (1) FLOATING WATER LIGHT FOR THE LIFE FLOAT WHERE MISSING.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Lifesaving
Issued 11 June 1990 Resolved
MARK OR STENCIL ALL STOWAGE COMPARTMENTS FOR THE ADULT PFD'S WHERE MISSING.
Condition: Unknown
Due 11 June 1990
Resolved 11 June 1990
Documentation
Issued 19 May 1989 Resolved
POST STABILITY LETTER ON BOARD.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Navigation
Issued 19 May 1989 Resolved
PLACE A CHART OF THE AREA BETWEEN MONTAUK POINT, NY AND FIRE ISLAND, NY ON BOARD PRIOR TO OPERATING IN THAT AREA.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Lifesaving
Issued 19 May 1989 Resolved
PROVIDE ON BOARD AND HAVE INSPECTED SEVEN ADDITIONAL ADULT PFD'S PRIOR TO CARRYING MORE THAN 73 PASSENGERS.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Electrical
Issued 19 May 1989 Resolved
MAKE REPAIRS TO AND PROVE OPERATION OF THE INDEPENDENT GENERATOR VOLT METERAND FREQUENCY METER.
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Lifesaving
Issued 19 May 1989 Resolved
PROVIDE ON BOARD THE FOLLOWING EQUIPMENT PRIOR TO OPERATIONS ON OCEANS ROUTE: (A) UHF RADIO (B) EPIRB (C) LIGHTS ON ALL PFD'S
Condition: Unknown
Due 19 May 1989
Resolved 19 May 1989
Engineering
Issued 2 May 1989 Resolved
RENEW BILGE PIPE IN #3 COMPARTMENT WHICH SERVICES #2 COMPARTMENT WHERE HOLED.
Condition: Unknown
Due 2 May 1989
Resolved 2 May 1989
Navigation
Issued 17 June 1987 Resolved
DEMONSTRATE BY RADIO CHECK THE OPERATION OF THE SSB RADIO. VESSEL IS RESTRICTED TO A 20 MILE COASTWISE ROUTE UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Construction/Loadline
Issued 17 June 1987 Resolved
FREE UP THE DOGGING MECHANISM FOR ALL WEATHER DECK HATCH COVERS AND THE ENGINE ROOM HATCH OPENING.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Electrical
Issued 17 June 1987 Resolved
PROVIDE A COVER FOR THE SINGLE 12V GENERATOR STARTING BATTERY. ALSO LINE THIS BATTERY BOX WITH FRP OR LEAD AND SECURE BOX TO PREVENT IT FROM SHIFTING.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Documentation
Issued 17 June 1987 Resolved
PROVIDE AND POST UNDER GLASS IN THE PILOTHOUSE THE VESSEL'S STABILITY LETTER.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Fire Fighting
Issued 17 June 1987 Resolved
DEMONSTRATE OPERATION OF THE ENGINE DRIVEN FIRE/BILGE PUMP.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Navigation
Issued 17 June 1987 Resolved
MAKE THE ANCHOR LIGHT OPERABLE PRIOR TO GETTING UNDERWAY.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Lifesaving
Issued 17 June 1987 Resolved
PROVIDE COAST GUARD APPROVED PFD LIGHTS FOR ALL PFD'S. VESSEL IS RESTRICTED TO 20 MILE COASTWISE ROUTE UNTIL THIS REQUIREMENT IS MET.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Lifesaving
Issued 17 June 1987 Resolved
PROVIDE 13 ADULT AND 1 CHILD'S TYPE I COAST GUARD APPROVED PFD'S. VESSEL IS RESTRICTED TO 72 TOTAL PERSONS UNTIL COMPLETED.
Condition: Unknown
Due 17 June 1987
Resolved 17 June 1987
Accommodation/Occupational Safety
Issued 10 December 1986 Resolved
COLLISION COMPARTMENT DRAIN VALVE INOPERABLE FROM MAIN DECK, FREE SAME.
Condition: Unknown
Due 10 December 1986
Resolved 10 December 1986
Accommodation/Occupational Safety
Issued 10 December 1986 Resolved
REMOVE RUBBER HOSE FROM 2 THROUGH-HULL FITTINGS IN MSD COMPARTMENT PORTSIDEAND REPLACE WITH STOP VALVES, PRESENTLY MISSING.
Condition: Unknown
Due 10 December 1986
Resolved 10 December 1986
Construction/Loadline
Issued 24 June 1985 Resolved
CONDUCT NON-DESTRUCTIVE TEST ON SUSPECTED CRACK LOCATED APROX. ONE-EIGTH INCH TO ONE-QUARTER INCH UNDER WELD BETWEEN 8'7"FORWARD AND 2'6" AFT ON DRIFT KEEL, PORT SIDE. U.S.C.G. MARINE INSPECTOR TO INSPECT AREA IN QUESTION PRIOR TO PREPARATION FOR TEST.
Condition: Unknown
Due 24 June 1985
Resolved 24 June 1985

Casualty record · 6

9 June 2006Routine · role: Involved in a Marine Casualty · 1 injured · activity 2695147
5 June 2012Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 4351170
28 August 2013Routine · role: Involved in a Marine Casualty · activity 4699621
2 September 2013Routine · role: Involved in a Marine Casualty · activity 4704224
7 June 2014Routine · role: Involved in a Marine Casualty · activity 4883860
7 September 2015Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 5722600
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record