Records from 2016 to 2026. Most recent: inspection, 9 February 2026.
Inspection history · 19
9 February 2026
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8307199
6 February 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8075424
5 March 2024
Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7868953
5 February 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7859852
24 August 2023
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 7776531
16 August 2023
Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7773744
29 November 2022
Simplified Stability Test · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7601614
10 November 2022
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7591017
5 April 2022
Deficiency Check · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7428745
24 March 2022
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7413737
20 April 2021
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7182124
23 March 2020
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6925709
17 March 2020
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6924296
25 April 2019
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6670237
30 March 2018
DAPI Audit · COI Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6378772
9 March 2018
Internal Structural Exam · Drydock Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6364280
19 April 2017
DAPI Audit · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6128511
4 May 2016
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5869708
23 March 2016
Drydock Exam · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5840088
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 9 February 2026
Resolved
accordance with § 160.050 in subchapter Q of this chapter. MI found that the grab line on the vessel's ring life buoy was deteriorated.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 11 March 2026
Resolved 3 March 2026
Resolution: Operator provided satisfactory photo of repair, see Documents.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 6 February 2025
Resolved
The person in command of a documented vessel must have on board that vessel the original Certificate of Documentation currently in effect for that vessel. Vessel’s Certificate of Documentation expired in OCT2025. (46 CFR 67.313)
Action required: 701 - Prior to carriage of passengers/cargo
Due 6 February 2025
Resolved 25 February 2025
Resolution: COD is valid and onboard vessel
08 - Alarms › N/A - No Subsystem › General alarm
Issued 6 February 2025
Resolved
A visual and audible alarm must be provided at the operating station to indicate a high water level in each of the following normally unmanned spaces: A space with a through-hull fitting below the deepest load waterline. MI found visual indicator for focsle inoperable. (46 CFR 182.530 (a)(1))
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 26 February 2025
Resolution: Operator installed new light panel.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 6 February 2025
Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2 1/2 gallon) buckets, with an attached lanyard. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. Vessel did not have fire buckets onboard. (46 CFR 181.610)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 25 February 2025
Resolution: fire bucket placed onboard vessel
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2025
Resolved
Each personal flotation device and ring life buoy must be marked with the vessel’s name. Vessel name on ring buoy on board illegible. (46 CFR 169.741)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 25 February 2025
Resolution: Vessel name rewritten on life ring.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2025
Resolved
Each child size life jacket must be stowed in a location that is appropriately marked and separated from adult life jackets so the child size life jackets are not mistaken for adult life jackets. Children’s life jackets were found to be stowed together with adults’ life jackets. (46 CFR 180.78 (a)(5))
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 25 February 2025
Resolution: Children's lifejackets stowed in separate compartment. Labeled correctly
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 6 February 2025
Resolved
Each life jacket, immersion suit, and ring life buoy must be marked in clearly legible block capital letters with the vessel's name. The vessel had life jackets that were marked with more than one vessel name. (46 CFR 185.604 (b))
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 25 February 2025
Resolution: Lifejackets correctly marked.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2025
Resolved
Each rescue boat and ring life buoy must be marked with Type II retroreflective material. Lifering on the vessel was discovered to have fading and peeling retroreflective tape. (46 CFR 185.604 (i))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 25 February 2025
Resolution: New retro applied
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 6 February 2025
Resolved
Each floating waterlight...must be attached to the lanyard with a corrosion-resistant clip. The corrosion-resistant clip was missing from the lifering. (46 CFR 180.70 (d)(3))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 20 February 2025
Resolved 25 February 2025
Resolution: clip replaced on lifering
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 5 March 2024
Resolved
A hatch cover must be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Hatch cover aft of pilothouse was not attached to the hatch frame. Attending MI observed satisfactory installation of hatch cover connection device while onboard vessel.
46 CFR 179.360(b)
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 5 March 2024
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 5 February 2024
Resolved
A vessel must comply with the applicable requirements for any radio and EPIRB installations, including the requirements for a station license and installation certificates to be issued by the FCC, as set forth in 47 CFR part 80. Station license and radiotelephony certificate have previous vessel name and incorrect call sign. Provide copies of updated certificates.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 5 March 2024
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 5 February 2024
Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: charts or large enough scale to make safe navigation possible. Charts onboard not up to date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2024
Resolved 5 March 2024
Resolution: Obtained updated charts
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 5 February 2024
Resolved
A power-driven vessel underway shall exhibit: a masthead light forward; a stern light. Forward and stern lights inoperable. Vessel restricted to daytime operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 5 March 2024
Resolution: Vessel fixed nav lights.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 5 February 2024
Resolved
The master of the vessel shall ensure that each EPIRB must be tested monthly to determine that it is operative. No record of monthly EPIRB testing available.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Resolved 5 February 2024
Resolution: Operator tested EPIRB.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 5 April 2022
Resolved
Fire Extinguishers servicing out of date. 46CFR176.810(b)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 22 April 2022
Resolution: Vessel owner provided updated fire extinguisher service report.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 5 April 2022
Resolved
Crew training and drill log missing. 46CFR185.420(c)
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2022
Resolved 26 April 2022
Resolution: Vessel owner provided crew training and drill log.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 April 2021
Resolved
Some of the medicines in the first aid kit are expired.
46CFR185.212
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 5 April 2022
Resolution: First aid kit medicine up to date.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 April 2021
Resolved
Stability letter needs to be posted at the operating station of the vessel. 46CFR176.306
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 5 April 2022
Resolution: Stability letter posted.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 20 April 2021
Resolved
FCC Safety Radiotelephony Certificate was onboard and filled out, but the ink was erased and hard to read. Needs to be more readable. 47CFR80.59(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 24 May 2021
Resolved 5 April 2022
Resolution: FCC Safety Radiotelephony Cert was legible.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 April 2019
Resolved
The light attached to the lifefloat was inoperable. Renew bulb and/or battery prior to operating at night.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 22 May 2019
Resolution: Battery renewed, light is operational
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 25 April 2019
Resolved
Alcohol test strips are expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2019
Resolved 22 May 2019
Resolution: Confirmed test strips onboard.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 April 2019
Resolved
The FCC Safety Certificate was expired.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 May 2019
Resolved 22 May 2019
Resolution: Received picture of updated certificate.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 9 March 2018
Resolved
Fuel tank fill valve corroded; potentially due to dissimilar metals. Clean with wire brush for further inspection.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 20 March 2018
Resolved 20 March 2018
Resolution: Cleaned with wire brush. No wastage. All sat.
Lifesaving › Lifefloat › Serviceable
Issued 19 April 2017
Resolved
Repair lifefloat holes
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 20 May 2017
Resolved 20 May 2017
Resolution: Owner serviced lifefloat and emailed photos.