MAURY USCG vessel records
← All vessels

SEA WOLF

SEA WOLF is a 1977 passenger vessel (inspected). The Coast Guard has recorded 18 inspections since 2016, most recently in March 2025, along with 15 deficiencies and 1 casualty investigation in 2021.

Records from 2016 to 2025. Most recent: inspection, 17 March 2025.

Built
1977
Last inspected
17 March 2025
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 17 March 2025
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDG7305
Flag
UNITED STATES
Maury page id
psix-49250

Documentation record

Registered dimensions (L × B × D)48.7 ft × 15.2 ft × 6.3 ft
Registered tonnagegross 40 / net 31
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES INC · SEATTLE, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portEMERYVILLE, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Registry
DocumentationValid · issued 16 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it40 - Regulatory (Subpart C or D), Gross Ton
31 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 18

17 March 2025 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8094027
4 March 2025 Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8085924
2 April 2024 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7885742
25 May 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7696244
15 February 2023 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7636239
20 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7611565
23 May 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7457245
23 July 2021 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7269592
29 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7185541
4 February 2021 Hull Examination · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7177109
24 March 2020 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6929924
10 April 2019 COI Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6653506
17 January 2019 Drydock Exam · Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6612042
11 April 2018 Annual Inspection
Physical examination · USCG Southwest District (dpw) · USCG Southwest District (CGD-SW) · Activity 6392485
20 February 2018 Administrative Inspection · Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6367826
6 April 2017 Administrative Inspection · Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6118506
31 January 2017 Administrative Inspection · Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6076542
28 April 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5939233

Deficiency record · 15

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 2 April 2024 Resolved
A submersible electric bilge pump may be used ... provided that: The pump is listed by an independent laboratory as meeting the requirements in UL 1113. Provide proof of UL rating for the engine room submersible electric bilge pump. 46 CFR 182.520(e)(1)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2024
Resolved 2 July 2024
Resolution: Operator corrected deficiency to the satisfaction of MI.
01 - Certificates & Documentation › 012 - Crew Certificates › Other (STCW)
Issued 2 April 2024 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2024
Resolved 2 July 2024
Resolution: Operator corrected deficiency to the satisfaction of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 2 April 2024 Resolved
The operator must secure each Type III device in a manner which prevents discharge of treated or untreated sewage. Acceptable methods of securing the device include; Closing the seacock and removing the handle; Padlocking the seacock in the closed position. Sewage tank valve wasn't secured. 33 CFR 159.7(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2024
Resolved 1 July 2024
Resolution: Operator corrected deficiency to the satisfaction of MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 2 April 2024 Resolved
A hatch cover must: Have securing devices; and be attached to the hatch frame or coaming by hinges, captive chains, or other devices of substantial strength to prevent its loss. Current securing device on lazarette hatch is not of substantial strength. 46 CFR 179.360 (b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2024
Resolved 1 July 2024
Resolution: Operator corrected deficiency to the satisfaction of MI.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 2 April 2024 Resolved
Provision shall be made by means of plugs, covers, etc., to prevent the admission of air into the space protected. Missing ventilation closure devices to engine room ventilation trunks. 46 CFR 181-35(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2024
Resolved 1 July 2024
Resolution: Operator corrected deficiency to the satisfaction of MI.
12 - Dangerous Goods › N/A - No Subsystem › Dangerous goods / harmful substances in pack. form
Issued 2 April 2024 Resolved
No flammable or combustible liquids may be stowed in any accommodation, control, or service space (other than a paint locker). Coolant and motor oil found in forward berthing space. 46 CFR 147.45(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 16 April 2024
Resolved 2 April 2024
Resolution: Operator removed coolant and motor oil found in forward berthing space.
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 2 April 2024 Resolved
Each disposable hydrostatic release unit must be marked with an expiration date of two years after the date on which the unit is installed. Hydrostatic release unit for IBA is beyond expiration date. 46 CFR 185.740 (b)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: Operator replaced expired Hydrostatic release.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 2 April 2024 Resolved
At each initial and subsequent inspection for certification, the owner or managing operator must be prepared to conduct tests and have the vessel ready for inspection of its fire protection equipment, including the following; Inspection of each portable fire extinguisher etc. Fire extinguisher in main seating area was not properly charged. 46 CFR 176.810 (a)(1)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: Operator replaced fire extinguisher.
09 - Working and Living Conditions › 092 - Working Conditions › Ventilation (Working spaces)
Issued 2 April 2024 Resolved
Machinery and fuel tank spaces shall be separated from accommodation spaces by watertight and/or vapor tight bulkheads. There is a leak in the vapor tight integrity of starboard aft sewage void bulkhead. 46CFR182.35-1(a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: operator sealed holes to maintain vapor tight integrity
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 2 April 2024 Resolved
Each rescue boat and ring life buoy must be marked with Type II retro reflective material. The retro reflective material on vessels ring life buoy is faded. 46 CFR 185.604(i)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: operator replaced faded retro reflective tape on ring life buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 2 April 2024 Resolved
Each life preserver carried on a vessel engaged in ocean coast wise..., must have a personal flotation device light. 04 inoperable lights on life jackets. 46 CFR 180.25-20 (a)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 2 April 2024
Resolved 2 April 2024
Resolution: Operator replaced 04 lifejackets.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 25 May 2023 Resolved
Vessels operated solely within 20 nautical miles of land must be equipped with a VHF-DSC radiotelephone installation meeting the requirements of § 80.1101(c)(2). Vessel has VHF-DSC radio that does not have proper MMSI programmed in and is not connected to GPS. Addtionally, the same for MF radio of which would be required for a future upgrade to Oceans route. Make repairs and have inspected by FCC licensed technician and provide Radio Safety Telephony Certificate. 46 CFR 184.502 47 CFR 80.905(a)(2)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 10 July 2023
Resolution: Vessel has had MMSI programmed into VHF and MF as required.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 29 April 2021 Resolved
On a vessel of at least 26ft in length, a visual and audible alarm must be provided at the operating station to indicate a high water level. Engine compartment high water alarm not displaying visually at the operating station. 46 CFR 182.530(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 6 May 2021
Resolution: Verified via video that all high level bilge alarms operational with audible and visual indicators for four compartments.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 29 April 2021 Resolved
A vessel must comply with the applicable requirements for any radio installations including installation certificates as set forth in 47 CFR part 80. Vessel did not have required FCC Safety Radiotelephony Certificate on board. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 13 May 2021
Resolved 30 April 2021
Resolution: Received photo documentation of signed FCC Safety Radiotelephony Certificate.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 24 March 2020 Resolved
A visual indicator must be provided at the operating station to indicate when any automatic bilge pump is operating. The number two compartment bilge pump visual indicator did not illuminate during pump operation.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 April 2020
Resolved 2 April 2020
Resolution: Installed new panel and observed operational test via FaceTime. All sat.

Casualty record · 1

23 July 2021Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 7269592
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.