KG ASIA

Built
1998
Last inspected
26 January 2016
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 10 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Bulk Carrier class in Maury's sources begin in 2016.

Inspection record

Last inspected 26 January 2016
…with no type recorded1
Operational controls None recorded without a removal date
Years with a record 1 calendar year (2016)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

9190377
492647
Flag
SOUTH KOREA
Maury page id
psix-492647

Documentation record

Tonnage as PSIX records it40489 - Convention (Subpart B), Gross Ton
25885 - Convention (Subpart B), Net Ton
87337 - Displacement, Ton
74732 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 2 inspections, each with its date, unit and type; 3 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its Coast Guard record spans fewer than two calendar years. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 2

26 January 2016 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5803341
6 January 2016 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5787199

Deficiency record · 3

Engineering › Fuel Oil Service System › Valve
Issued 6 January 2016 Resolved
0750 - Fire prevention - Every oil fuel pipe, which, if damaged, would allow oil to escape from a storage, settling or daily service tank shall be fitted with a cock or valve directly on the tank capable of being closed from a safe position. While conducting engine room examination PSCO observed quick closing fuel vlaves blocked in the open position by a piece of wood. 74 SOLAS (01) II-2/15.2.5
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 18 January 2016
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. Wood was removed from block fuel valve and class tested the valve with satisfactory results.
Engineering › Diesel Engine (propulsion-direct drive) › Crankcase
Issued 6 January 2016 Resolved
1410 - Propulsion Main Engine - Internal combustion engines of 2,250 kW and above or having cylinders of more than 300 mm bore shall be provided with crankcase oil mist detectors or engine bearing temperature monitors or equivalent devices. Oil mist detector was alarming for low air pressure. 74 SOLAS (04) II-1/47.2
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 18 January 2016
Resolution: Received, reviewed and accepted class report from Korean Register of Shipping stating the deficiency was rectified. Oil mist detector was removed and gaskets replaced. All sat.
Electrical › Electric Generation Source (emergency) › Power Requirement
Issued 6 January 2016 Resolved
0950 - Electrical equipment in general - The condition of the ship and its equipment shall be maintained to conform with the provisions of present regulations to ensure that the ship in all respects will remain fit to proceed to sea without danger to the ship or persons on board. While conducting EDG test PSCO observed the primary charging system bypassed. 74 SOLAS (14) I/11
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 6 February 2016
Resolved 18 January 2016
Resolution: Received, reviewed and accepted class report from [name withheld] stating the deficiency was rectified. Installed battery charger was connected and used for emergency diesel generator.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.