Records from 1981 to 1988. Most recent: inspection, 17 February 1988.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 9
17 February 1988
Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1328309
7 April 1987
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021125
25 February 1987
Hull Examination
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1021288
22 January 1987
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1015327
30 January 1986
Re-Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 993502
30 January 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1288726
14 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 971834
9 September 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 966897
6 August 1981
Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 971358
Unknown
Issued 22 January 1987
Resolved
REPAIR LIGHTING IN THE STEERING GEAR COMPARTMENT. REMOVE ALL TEMPORARY WIRING.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Fire Fighting
Issued 22 January 1987
Resolved
MAKE PERMANENT REPAIRS TO FIRE MAIN BY REPLACING THAT SECTION OF PIPING IN ENGINE ROOM CLOSE TO PUMP CURRENTLY WITH TEMPORARY PATCH. PROVE REPAIRS BYHYDRO-TESTING TO 1-1/2 MAWP. PROVE OPERATION OF FIRE PUMP RELIEF VALVE.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Construction/Loadline
Issued 22 January 1987
Resolved
RENEW SECTION OF PIPING IN BALLAST/DRILL WATER LINE IN VICINITY OF BALLAST PUMP IN ENGINE ROOM. PROVE REPAIRS BY HYDRO-TESTING TO 1-1/2 MAWP.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Engineering
Issued 22 January 1987
Resolved
INSTALL, WITHOUT DELAY, RELIEF VALVE ON STARBOARD AIR PRESSURE TANK.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Fire Fighting
Issued 22 January 1987
Resolved
POST NEW COPY OF FIRE CONTROL PLAN. (PRESENT COPY IS FADED AND SMUDGED TO POINT OF BEING UNREADABLE.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Lifesaving
Issued 22 January 1987
Resolved
PROVIDE 5 ADDITIONAL CARTRIDGES FOR LINE THROWING GUN SUCH THAT THERE WILL BE A TOTAL OF 25.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Unknown
Issued 22 January 1987
Resolved
MOVE EMERGENCY POSITION INDICATING BEACON (EPIRB) TO A POSITION WHERE IT WILL BE CAPABLE OF FLOATING FREE, E.G. NOT OBSTRUCTED BY OVERHEAD AWNINGS.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Lifesaving
Issued 22 January 1987
Resolved
REPLACE RING BUOY ON ACCOMODATION DECK, PORT SIDE, AFT.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Navigation
Issued 22 January 1987
Resolved
MAKE POWER FAILURE ALARM FOR STEERING OPERATIONAL.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Electrical
Issued 22 January 1987
Resolved
PROVIDE, AS NECESSARY, PROPER AND ADEQUATE SUPPORTS AND CONNECTIONS FOR ELECTRICAL CABLES IN ENGINE ROOM.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Construction/Loadline
Issued 22 January 1987
Resolved
RENEW FLAME SCREENS AND MAKE CLOSURE DEVICES OPERABLE ON ALL TANK VENTS ON WEATHER DECKS. LABEL EACH VENT AS TO THE TANK IT SERVES.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Engineering
Issued 22 January 1987
Resolved
REPAIR EXHAUST LEAKS ON NO. 2 MAIN ENGINE AND NO. 2 GENERATOR ENGINE.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Fire Fighting
Issued 22 January 1987
Resolved
HYDRO-TEST AIR BOTTLES FOR SELF-CONTAINED BREATHING APPARATUS.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Lifesaving
Issued 22 January 1987
Resolved
MARKING REQUIRED BY 46 CFR 97.37-7 FOR GENERAL ALARM BELLS TO BE PLACED IN CLOSE PROXIMITY TO BELL IN THE ENGINE ROOM.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Fire Fighting
Issued 22 January 1987
Resolved
SERVICE FIXED FIRE-FIGHTING SYSTEM, LABEL CONTROL VALVES IN GALLEY. POST OPERATING INSTRUCTIONS. LABEL SIREN IN ENGINE ROOM. PROVE OPERATION OF ELECTRICAL SHUTDOWNS.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Engineering
Issued 22 January 1987
Resolved
OPEN ALL PRESSURE VESSELS FOR USCG INSPECTION. PROVE OPERATION OF ALL RELIEF VALVES.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Construction/Loadline
Issued 22 January 1987
Resolved
APPROPRIATELY MARK EMERGENCY ENGINE ROOM ESCAPE HATCHES.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Lifesaving
Issued 22 January 1987
Resolved
REPACE ALL LIGHTS FOR LIFEJACKETS WITH CURRENTLY DATED ONES.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Lifesaving
Issued 22 January 1987
Resolved
SERVICE LIFERAFTS AND HYDROSTATIC RELEASES.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Lifesaving
Issued 22 January 1987
Resolved
MAKE STARBOARD LIFERAFT STATION EMBARKATION LIGHT OPERATIONAL.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Electrical
Issued 22 January 1987
Resolved
MAKE AIR CONDITIONING REMOTE SHUTDOWN OPERATIONAL. PROVE OPERATION OF ALL OTHER EMERGENCY SHUTDOWNS FOR VENTILATION AND FUEL PUMPS. PROVIDE IDENTIFYING LABELS FOR ALL EMERGENCY SHUTDOWNS.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Accommodation/Occupational Safety
Issued 22 January 1987
Resolved
MAKE PERMANENT REPAIRS TO, OR REPLACE, SANITARY WATER PRESSURE TANK.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Engineering
Issued 22 January 1987
Resolved
REPLACE WITH APPROVED TYPE, OR REMOVE, JURY RIGGED PLASTIC SIGHT GLASSES ONDIESEL DAY TANKS.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Unknown
Issued 22 January 1987
Resolved
MAKE OPERATIONAL ALL REMOTE REACH RODS AND PROVE OPERATION OF SAME.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987
Unknown
Issued 22 January 1987
Resolved
CONDUCT EMERGENCY DRILLS IN PRESENCE OF USCG MARINE INSPECTOR.
Condition: Unknown
Due 22 January 1987
Resolved 22 January 1987