Records from 2008 to 2026. Most recent: inspection, 14 April 2026.
Inspection history · 22
14 April 2026
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8349684
18 November 2024
Examination of Repairs · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8038309
4 October 2024
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8016415
9 April 2024
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7893907
18 May 2023
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7691292
3 March 2023
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662867
22 November 2022
In-Service Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7598454
6 April 2022
COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7421180
2 September 2021
In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7302408
21 April 2021
Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7179773
5 January 2021
Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7119801
1 December 2020
Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7104517
8 June 2020
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6970980
31 January 2020
Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6900486
16 October 2019
In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6836145
30 May 2019
Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6699257
29 November 2018
Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6589044
25 September 2018
Administrative Inspection
Administrative · Navigation Center · Activity 6548013
26 April 2018
Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6399810
6 April 2017
COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6117743
15 November 2016
Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6041375
9 May 2016
Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5870812
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 November 2024
Resolved
Rotted area of hull was found where an old sea temperature probe was penetrating the hull. Remove old sensor and provide permanent plug.
Action required: 705 - Other - as specified
Resolved 2 December 2024
Resolution: Probe was removed, rotted plywood excavated and replaced with new section.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 November 2024
Resolved
Vessel completed dry dock and has not completed IFR / Egress modifications or drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until modifications are made and an egress drill is completed.
Action required: 705 - Other - as specified
Resolved 18 February 2025
Resolution: Satisfactory egress drill were witnessed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 April 2024
Resolved
All overnight passenger vessels are required to install and maintain monitoring device to ensure wakefulness of the crew, remain operable during night time watch and be arranged to ensure proper coverage of passenger accommodation spaces, common areas and spaces with potential fire hazards. Watch alarm not operable at time of inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 April 2024
Resolved
All logbooks must be maintain to capture required drills and EPIRB tests. Log book not available at the time of the inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2024
Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Found electrical cabel to installed box freezer was spliced to extended electrical cabeling without protection. Must provide protections to electrical connection to satisfaction of the USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 25 April 2024
Resolution: Operator provided pic rectifying def.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 18 May 2023
Resolved
Replace the EPIRB's expired hydrostatic release. Vessel is restricted to operate no more than three (03) nautical miles from shore until deficiency is rectified.
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Crew purchased a new hydro release.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2023
Resolved
Label fire buckets and install lanyards on fire buckets so they may be lowered past the waterline.
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 22 November 2022
Resolved
Stbd side hand rail at base of support found to be cracked at weld. Repair cracked weld.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 10 April 2023
Resolution: Re-welded hand rail.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 22 November 2022
Resolved
Stbd side deck beams second and third from aft found to have rot. Cut back to good wood treat and sister.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 10 April 2023
Resolution: Treated and sistered deck beam.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 April 2022
Resolved
Replace all expired distress signals. 12 red or 6 red/6orange for oceans route.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 10 May 2022
Resolution: Replaced with new flares
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2022
Resolved
Complete DAPI Audit by providing 02 crewmember's random drug test results from ASTS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 10 May 2022
Resolution: Added crew members to DAPI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2022
Resolved
Correct the following electrical issues found:
1) Exposed splice under helm station,
2) Cover pop-out on E/R distribution panel,
3) Ground wire disconnected in lazzarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 9 May 2022
Resolution: Vessel POC corrected electrical hazards.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 April 2021
Resolved
Install lagging on 03 exhaust pipes on both MDE & Gen.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 27 April 2021
Resolution: Received e-mail from operator with pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2021
Resolved
Hardwire all permanent electrical equipment under the wheel house & remove power strip.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 27 April 2021
Resolution: Received e-mail from operator with pictures.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2020
Resolved
Complete hull exam and ISE prior to the carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2021
Resolution: Credit hull exam / ISE conducted.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 16 October 2019
Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from passenger and crew accommodation spaces below the main deck. Vessel did not have adequate lighting at the forward emergency exit void. Provide emergency lighting within this area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 8 November 2019
Resolution: Lighting installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2019
Resolved
At each inspection, all observed fire hazards must be corrected to a satisfactory condition. Grease extraction hood above galley cooking surface found with excessive grease. Clean grease extraction hood/ventilation form galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 8 November 2019
Resolution: Vent cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019
Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 9 March 2020
Resolution: Completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019
Resolved
Update drug testing roster list to include the entire crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2019
Resolution: Updated roster list was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019
Resolved
Remove dead-ended valves at upper operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Cables were pulled back and taped off.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 May 2019
Resolved
Prove operation of engine compartment vent closures.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Vessel's vent closures were repaired and properly closed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019
Resolved
Vessel's only generator was found to have a dripping and spraying fuel leak, make proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2019
Resolution: Diesel technician replaced the fuel pump.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 May 2019
Resolved
Provide proper instructions for operating fixed CO2 system and align instruction with posted emergency procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2019
Resolution: Updated instructions were posted and match emergency procedures.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 November 2018
Resolved
Make repairs to starboard aft lazz. Wood soft and needs to be cropped and renewed to solid wood.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2018
Resolved 24 January 2019
Resolution: Cropped and renewed to good wood.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 November 2018
Resolved
Scrape and treat angle hair under hatches.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2018
Resolved 24 January 2019
Resolution: Angle scraped and treated.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018
Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 October 2018
Resolution: Verified in VIVS
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 April 2017
Resolved
Replace worn hydraulic line in lazeratte. (prior to carrying passengers)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2017
Resolution: Vessel owner installed new hose and tested.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 May 2016
Resolved
Renew FCC Safety Radio Cert. Cert expired Apr 2015.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 10 May 2016
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 9 May 2016
Resolved
Provide smoke detector in galley/salon area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 10 May 2016