PRODUCER is a 1977 passenger vessel (inspected). The Coast Guard has recorded 22 inspections since 2016, most recently in April 2026, along with 29 deficiencies and 1 casualty investigation in 2008.

Records from 2008 to 2026. Most recent: inspection, 14 April 2026.

Built
1977
Last inspected
14 April 2026
Documentation
Valid · documentation file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 14 April 2026
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH9695
Flag
UNITED STATES
Maury page id
psix-49301

Documentation record

Registered dimensions (L × B × D)62.0 ft × 21.0 ft × 6.2 ft
Registered tonnagegross 74 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAWAY BOAT CO. · LONG BEACH, CA, UNITED STATES · built 1977
Hull materialWood
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 2016 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 22

14 April 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8349684
18 November 2024 Examination of Repairs · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8038309
4 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8016415
9 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7893907
18 May 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7691292
3 March 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662867
22 November 2022 In-Service Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7598454
6 April 2022 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7421180
2 September 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7302408
21 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7179773
5 January 2021 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7119801
1 December 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7104517
8 June 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6970980
31 January 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6900486
16 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6836145
30 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6699257
29 November 2018 Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6589044
25 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6548013
26 April 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6399810
6 April 2017 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6117743
15 November 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6041375
9 May 2016 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5870812

Deficiency record · 29

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 November 2024 Resolved
Rotted area of hull was found where an old sea temperature probe was penetrating the hull. Remove old sensor and provide permanent plug.
Action required: 705 - Other - as specified
Resolved 2 December 2024
Resolution: Probe was removed, rotted plywood excavated and replaced with new section.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 November 2024 Resolved
Vessel completed dry dock and has not completed IFR / Egress modifications or drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until modifications are made and an egress drill is completed.
Action required: 705 - Other - as specified
Resolved 18 February 2025
Resolution: Satisfactory egress drill were witnessed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 April 2024 Resolved
All overnight passenger vessels are required to install and maintain monitoring device to ensure wakefulness of the crew, remain operable during night time watch and be arranged to ensure proper coverage of passenger accommodation spaces, common areas and spaces with potential fire hazards. Watch alarm not operable at time of inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 April 2024 Resolved
All logbooks must be maintain to capture required drills and EPIRB tests. Log book not available at the time of the inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Found electrical cabel to installed box freezer was spliced to extended electrical cabeling without protection. Must provide protections to electrical connection to satisfaction of the USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 25 April 2024
Resolution: Operator provided pic rectifying def.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 18 May 2023 Resolved
Replace the EPIRB's expired hydrostatic release. Vessel is restricted to operate no more than three (03) nautical miles from shore until deficiency is rectified.
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Crew purchased a new hydro release.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2023 Resolved
Label fire buckets and install lanyards on fire buckets so they may be lowered past the waterline.
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 22 November 2022 Resolved
Stbd side hand rail at base of support found to be cracked at weld. Repair cracked weld.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 10 April 2023
Resolution: Re-welded hand rail.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 22 November 2022 Resolved
Stbd side deck beams second and third from aft found to have rot. Cut back to good wood treat and sister.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 10 April 2023
Resolution: Treated and sistered deck beam.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 April 2022 Resolved
Replace all expired distress signals. 12 red or 6 red/6orange for oceans route.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 10 May 2022
Resolution: Replaced with new flares
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2022 Resolved
Complete DAPI Audit by providing 02 crewmember's random drug test results from ASTS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 10 May 2022
Resolution: Added crew members to DAPI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2022 Resolved
Correct the following electrical issues found: 1) Exposed splice under helm station, 2) Cover pop-out on E/R distribution panel, 3) Ground wire disconnected in lazzarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 9 May 2022
Resolution: Vessel POC corrected electrical hazards.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 April 2021 Resolved
Install lagging on 03 exhaust pipes on both MDE & Gen.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 27 April 2021
Resolution: Received e-mail from operator with pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2021 Resolved
Hardwire all permanent electrical equipment under the wheel house & remove power strip.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 27 April 2021
Resolution: Received e-mail from operator with pictures.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2020 Resolved
Complete hull exam and ISE prior to the carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2021
Resolution: Credit hull exam / ISE conducted.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 16 October 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from passenger and crew accommodation spaces below the main deck. Vessel did not have adequate lighting at the forward emergency exit void. Provide emergency lighting within this area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 8 November 2019
Resolution: Lighting installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2019 Resolved
At each inspection, all observed fire hazards must be corrected to a satisfactory condition. Grease extraction hood above galley cooking surface found with excessive grease. Clean grease extraction hood/ventilation form galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 8 November 2019
Resolution: Vent cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 9 March 2020
Resolution: Completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019 Resolved
Update drug testing roster list to include the entire crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2019
Resolution: Updated roster list was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019 Resolved
Remove dead-ended valves at upper operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Cables were pulled back and taped off.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 May 2019 Resolved
Prove operation of engine compartment vent closures.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Vessel's vent closures were repaired and properly closed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019 Resolved
Vessel's only generator was found to have a dripping and spraying fuel leak, make proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2019
Resolution: Diesel technician replaced the fuel pump.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 May 2019 Resolved
Provide proper instructions for operating fixed CO2 system and align instruction with posted emergency procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2019
Resolution: Updated instructions were posted and match emergency procedures.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 November 2018 Resolved
Make repairs to starboard aft lazz. Wood soft and needs to be cropped and renewed to solid wood.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2018
Resolved 24 January 2019
Resolution: Cropped and renewed to good wood.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 November 2018 Resolved
Scrape and treat angle hair under hatches.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2018
Resolved 24 January 2019
Resolution: Angle scraped and treated.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 October 2018
Resolution: Verified in VIVS
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 April 2017 Resolved
Replace worn hydraulic line in lazeratte. (prior to carrying passengers)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2017
Resolution: Vessel owner installed new hose and tested.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 May 2016 Resolved
Renew FCC Safety Radio Cert. Cert expired Apr 2015.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 10 May 2016
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 9 May 2016 Resolved
Provide smoke detector in galley/salon area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 10 May 2016

Casualty record · 1

20 September 2008Routine · role: Involved in a Marine Casualty · activity 3330485
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.