PRODUCER is a 1977 passenger vessel (inspected). The Coast Guard has recorded 86 inspections since 1985, most recently in April 2026, along with 82 deficiencies and 1 casualty investigation in 2008.

Records from 1985 to 2026. Most recent: inspection, 14 April 2026.

Built
1977
Last inspected
14 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH9695
Flag
UNITED STATES
367033990 (licence lapsed)
Maury page id
psix-49301

Inspections, by type

…with no type recorded15
Years with a record 37 calendar years (1985–2026)
The 86 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)62.0 ft × 21.0 ft × 6.2 ft
Registered tonnagegross 74 / net 50
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderSEAWAY BOAT CO. · LONG BEACH, CA, UNITED STATES · built 1977
Hull materialWood
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN DIEGO, CA
Trade endorsementsCoastwise, unrestricted, Registry
DocumentationValid · issued 20 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it74 - Regulatory (Subpart C or D), Gross Ton
50 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH9695MMSI 367033990 · expired · compulsorily equipped · granted 6 May 2015, cancelled 7 June 2025
WDC4989MMSI 367033990 · terminated · compulsorily equipped · granted 15 April 2005, cancelled 29 April 2015
WAA9302MMSI not assigned · expired · compulsorily equipped · granted 8 August 1994, cancelled 9 October 2004
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 86

14 April 2026 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8349684
18 November 2024 Examination of Repairs · Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8038309
4 October 2024 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 8016415
9 April 2024 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7893907
18 May 2023 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7691292
3 March 2023 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7662867
22 November 2022 In-Service Inspection · Internal Structural Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7598454
6 April 2022 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7421180
2 September 2021 In-Service Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7302408
21 April 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7179773
5 January 2021 Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7119801
1 December 2020 Administrative Inspection
Administrative · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 7104517
8 June 2020 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6970980
31 January 2020 Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6900486
16 October 2019 In-Service Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6836145
30 May 2019 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6699257
29 November 2018 Drydock Exam · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6589044
25 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6548013
26 April 2018 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6399810
6 April 2017 COI Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6117743
15 November 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 6041375
9 May 2016 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 5870812
12 May 2014 Annual Inspection · DAPI Audit
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4856419
1 December 2011 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 4199739
26 October 2010 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3877913
7 November 2008 Hull Examination · Examination of Repairs · Internal Structural Exam
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3349075
20 September 2008 Type not recorded
No type recorded · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3330485
22 April 2008 Deficiency Check · Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 3184151
18 April 2007 COI Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2907466
21 April 2006 Annual Inspection
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2621550
13 April 2005 Annual Inspection · Deficiency Check
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2328580
17 December 2004 Hull Examination
Physical examination · Sector San Diego · USCG Southwest District (CGD-SW) · Activity 2257148
6 April 2004 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 2033515
16 December 2003 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1965229
11 April 2003 Annual Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1767186
18 December 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1720249
1 February 2002 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1483277
28 December 2001 Examination of Repairs · COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1474419
5 April 2001 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1060941
27 March 2001 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1376530
25 January 2001 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1471933
23 March 2000 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1389034
10 December 1999 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1461225
19 October 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 801884
24 September 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 651493
30 March 1999 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 213909
30 March 1999 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1369126
18 February 1999 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 797960
16 November 1998 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1375574
31 March 1998 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1469849
8 December 1997 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1364494
30 July 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 213838
14 April 1997 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1378017
7 April 1997 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1096903
7 March 1997 Plan Review "T" Boat
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1102358
3 December 1996 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1441142
10 October 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 154936
6 August 1996 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 185714
1 April 1996 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1387999
12 December 1995 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1422609
4 April 1995 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1431498
4 January 1995 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1416073
18 November 1994 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1443520
21 March 1994 Re-Inspection · Drydock Extension
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1359750
5 April 1993 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1147851
3 December 1992 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1134917
8 June 1992 Drydock Extension
Administrative · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1465715
8 April 1992 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1261809
28 March 1991 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1220905
21 December 1990 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 918603
22 May 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1214298
14 May 1990 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 929911
10 April 1990 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 914066
5 October 1989 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1023234
12 April 1989 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 895011
16 March 1989 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1204488
28 September 1988 Deficiency Check
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1352001
22 June 1988 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 893270
12 April 1988 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1195629
14 April 1987 COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1022226
22 December 1986 Hull Examination
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1335250
11 September 1986 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1273773
18 April 1986 Re-Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1307288
23 April 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1289210
27 March 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 979526
7 January 1985 Type not recorded
No type recorded · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1285274

Deficiency record · 82

02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 18 November 2024 Resolved
Rotted area of hull was found where an old sea temperature probe was penetrating the hull. Remove old sensor and provide permanent plug.
Action required: 705 - Other - as specified
Resolved 2 December 2024
Resolution: Probe was removed, rotted plywood excavated and replaced with new section.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 18 November 2024 Resolved
Vessel completed dry dock and has not completed IFR / Egress modifications or drills. Vessel is prohibited from carrying overnight passengers or allowing passengers in the bunk rooms until modifications are made and an egress drill is completed.
Action required: 705 - Other - as specified
Resolved 18 February 2025
Resolution: Satisfactory egress drill were witnessed.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 9 April 2024 Resolved
All overnight passenger vessels are required to install and maintain monitoring device to ensure wakefulness of the crew, remain operable during night time watch and be arranged to ensure proper coverage of passenger accommodation spaces, common areas and spaces with potential fire hazards. Watch alarm not operable at time of inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 9 April 2024 Resolved
All logbooks must be maintain to capture required drills and EPIRB tests. Log book not available at the time of the inspection. Corrected on the spot.
Action required: 10 - Deficiency Rectified
Resolved 9 April 2024
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 April 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to: Protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Found electrical cabel to installed box freezer was spliced to extended electrical cabeling without protection. Must provide protections to electrical connection to satisfaction of the USCG Marine Inspector.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 May 2024
Resolved 25 April 2024
Resolution: Operator provided pic rectifying def.
11 - Life Saving Appliances › N/A - No Subsystem › Radio life-saving appliances
Issued 18 May 2023 Resolved
Replace the EPIRB's expired hydrostatic release. Vessel is restricted to operate no more than three (03) nautical miles from shore until deficiency is rectified.
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Crew purchased a new hydro release.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 May 2023 Resolved
Label fire buckets and install lanyards on fire buckets so they may be lowered past the waterline.
Action required: 10 - Deficiency Rectified
Resolved 18 May 2023
Resolution: Corrected on the spot.
09 - Working and Living Conditions › 092 - Working Conditions › Structural features (ship)
Issued 22 November 2022 Resolved
Stbd side hand rail at base of support found to be cracked at weld. Repair cracked weld.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 10 April 2023
Resolution: Re-welded hand rail.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 22 November 2022 Resolved
Stbd side deck beams second and third from aft found to have rot. Cut back to good wood treat and sister.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 February 2023
Resolved 10 April 2023
Resolution: Treated and sistered deck beam.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 6 April 2022 Resolved
Replace all expired distress signals. 12 red or 6 red/6orange for oceans route.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 10 May 2022
Resolution: Replaced with new flares
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 6 April 2022 Resolved
Complete DAPI Audit by providing 02 crewmember's random drug test results from ASTS.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 10 May 2022
Resolution: Added crew members to DAPI.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 6 April 2022 Resolved
Correct the following electrical issues found: 1) Exposed splice under helm station, 2) Cover pop-out on E/R distribution panel, 3) Ground wire disconnected in lazzarette.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 6 May 2022
Resolved 9 May 2022
Resolution: Vessel POC corrected electrical hazards.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 21 April 2021 Resolved
Install lagging on 03 exhaust pipes on both MDE & Gen.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 27 April 2021
Resolution: Received e-mail from operator with pictures.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2021 Resolved
Hardwire all permanent electrical equipment under the wheel house & remove power strip.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2021
Resolved 27 April 2021
Resolution: Received e-mail from operator with pictures.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 December 2020 Resolved
Complete hull exam and ISE prior to the carriage of passengers.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 5 January 2021
Resolution: Credit hull exam / ISE conducted.
09 - Working and Living Conditions › 091 - Living Conditions › Lighting (Accommodation)
Issued 16 October 2019 Resolved
Each vessel must have adequate emergency lighting fitted along the line of escape to the main deck from passenger and crew accommodation spaces below the main deck. Vessel did not have adequate lighting at the forward emergency exit void. Provide emergency lighting within this area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 8 November 2019
Resolution: Lighting installed.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 16 October 2019 Resolved
At each inspection, all observed fire hazards must be corrected to a satisfactory condition. Grease extraction hood above galley cooking surface found with excessive grease. Clean grease extraction hood/ventilation form galley.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 8 November 2019
Resolution: Vent cleaned.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 16 October 2019 Resolved
Vessel has been identified as having various A/C electrical modifications since initial certification. Sector San Diego does not have vessels electrical plans on file. Provide a one-line electrical drawing for all A/C switchboards and distribution panels. Include all circuit loads, conductor sizes, over current protection, and max panel ratings in amps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 15 November 2019
Resolved 9 March 2020
Resolution: Completed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 30 May 2019 Resolved
Update drug testing roster list to include the entire crew.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2019
Resolution: Updated roster list was provided.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019 Resolved
Remove dead-ended valves at upper operating station.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Cables were pulled back and taped off.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 30 May 2019 Resolved
Prove operation of engine compartment vent closures.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 30 May 2019
Resolution: Vessel's vent closures were repaired and properly closed.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 30 May 2019 Resolved
Vessel's only generator was found to have a dripping and spraying fuel leak, make proper repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 4 June 2019
Resolution: Diesel technician replaced the fuel pump.
07 - Fire Safety › N/A - No Subsystem › Fire control plan
Issued 30 May 2019 Resolved
Provide proper instructions for operating fixed CO2 system and align instruction with posted emergency procedures.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 4 June 2019
Resolution: Updated instructions were posted and match emergency procedures.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 29 November 2018 Resolved
Make repairs to starboard aft lazz. Wood soft and needs to be cropped and renewed to solid wood.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2018
Resolved 24 January 2019
Resolution: Cropped and renewed to good wood.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 29 November 2018 Resolved
Scrape and treat angle hair under hatches.
Action required: 17 - Rectify deficiencies prior to departure
Due 29 December 2018
Resolved 24 January 2019
Resolution: Angle scraped and treated.
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 25 September 2018 Resolved
ZERO LENGTH OR BEAM: no dimension information (AIS Antenna Position ABCD values equals 0), ZERO DRAFT: no static draft information
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 17 October 2018
Resolution: Verified in VIVS
Engineering › Steering Gear System › Hydraulic Hose
Issued 6 April 2017 Resolved
Replace worn hydraulic line in lazeratte. (prior to carrying passengers)
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 6 April 2017
Resolution: Vessel owner installed new hose and tested.
Documentation › Certificates/Documents › FCC Safety Radiotelephony Certificate
Issued 9 May 2016 Resolved
Renew FCC Safety Radio Cert. Cert expired Apr 2015.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 10 May 2016
Fire Fighting › Fixed Fire Detection System › Smoke Detectors
Issued 9 May 2016 Resolved
Provide smoke detector in galley/salon area.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 9 June 2016
Resolved 10 May 2016
Lifesaving › Inflatable Buoyant Apparatus › Approval
Issued 12 May 2014 Resolved
Provide current IBA inspection and properly install prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 June 2014
Resolved 22 May 2014
Engineering › Fuel Oil Service System › Hose
Issued 12 May 2014 Resolved
Replace wasted fuel return hose on both MDEs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 16 May 2014
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 12 May 2014 Resolved
Replace expired battery for lifering buoy light.
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 16 May 2014
Electrical › Electrical Distribution System (service) › Wiring
Issued 12 May 2014 Resolved
Remove extension cord and hardwire video camera that monitors engine room.
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 16 May 2014
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 12 May 2014 Resolved
Replace retroflective tape on back of 01 adult lifejacket
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 June 2014
Resolved 12 May 2014
Resolution: Retroflective tape replace onboard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Quantity of CO2
Issued 22 April 2008 Resolved
Determine amount of CO2 in E/R fixed fire system. Approved plans, COI, and servicing report states 100lbs. Btl installed states 75lbs.
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 April 2008
Resolved 23 April 2008
Resolution: Btl replaced with 100lb CO2.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 April 2008 Resolved
Update 1st aid equipment to meet all required items per 184.710. Missing eye wash, ammonia inhalents, asprin, etc.
Due 7 May 2008
Resolved 23 April 2008
Navigation › Piloting/Steering › Marine Charts
Issued 22 April 2008 Resolved
Update marine charts.
Due 7 May 2008
Resolved 23 April 2008
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 22 April 2008 Resolved
Repair SSB (MF) radio. Vessel restricted to NMT 20 miles from shore until corrected.
Due 7 May 2008
Resolved 23 April 2008
Communications › Radio Communications › Radiotelephone Transceiver (2-27.5 MHz)
Issued 22 April 2008 Resolved
Install DSC capable SSB radio. Vsl restricted to NMT 100 miles from shore until corrected. If not corrected by due date then COI route will be ammended to reflect restriction above.
Action required: 705 - Other - as specified
Due 22 October 2008
Resolved 7 November 2008
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Controls
Issued 22 April 2008 Resolved
Move CO2 fire system (E/R) pressure switch outside of the space per USCG approved operation, installation, and maintence manual.
Due 22 October 2008
Resolved 7 November 2008
Fire Fighting › Fire Bucket › Availability
Issued 22 April 2008 Resolved
Provide (3) buckets w/lanyards, labeled "fire bucket" of at least 2.5 gallon capacity each.
Due 7 May 2008
Resolved 23 April 2008
Lifesaving › Inflatable Buoyant Apparatus › Servicing
Issued 18 April 2007 Resolved
Service and properly install 3 inflatable buoyant apparatus (IBA), no passengers until corrected.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 20 April 2007
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 18 April 2007 Resolved
Provide current FCC Safety Radio Certificate.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 20 April 2007
Documentation › Logs/Records › Drug Test Records
Issued 18 April 2007 Resolved
Provide proof of enrollment in drug testing program for entire crew. No passengers until corrected.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 20 April 2007
Personnel › Certificates/Documents/Licenses › License, Radio Officer
Issued 18 April 2007 Resolved
Provide valid FCC Marine Radio Operator Permit.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 14 May 2007
Engineering › Fuel Oil Storage/Transfer System › Filter/Strainer
Issued 18 April 2007 Resolved
Remove fuel from racors in E/R.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 20 April 2007
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 18 April 2007 Resolved
Provide tidal current tables.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 20 April 2007
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 18 April 2007 Resolved
Provide one (1) adult Type-1 PFD, vessel restricted to no more than 47 total persons until corrected.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 20 April 2007
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 April 2007 Resolved
Install blank for open circuit breaker on E/R electrical distribution panel.
Action required: 705 - Other - as specified
Due 18 May 2007
Resolved 20 April 2007
Documentation › Certificates/Documents › FCC SSL
Issued 13 April 2005 Resolved
Update expired FCC station license
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 15 April 2005
Resolution: Applied for temporary operator permit while awaiting renewal.
Documentation › Certificates/Documents › FCC SSL
Issued 13 April 2005 Resolved
Update FCC redio safety certificate
Action required: 705 - Other - as specified
Due 13 May 2005
Resolved 15 April 2005
Resolution: Received a copy of a Safety Radio certificate.
Lifesaving › Lifejacket/PFD (Type I)
Issued 11 April 2002 Resolved
Renew retro tape on identified PFDs. LEGACY COMPONENT DESC: Retroreflective Material
Condition: Improper/Lack of Maintenance
Due 11 May 2002
Resolved 11 April 2002
Accommodation/Occupational Safety › Medical/First Aid
Issued 11 April 2002 Resolved
Renew expired items in first aid kit and renew container. LEGACY COMPONENT DESC: Medicine Chest
Condition: Improper/Lack of Maintenance
Due 11 May 2002
Resolved 11 April 2002
Communications › Radio Communications
Issued 11 April 2002 Resolved
Update expired EPIRB hydrostatic release. LEGACY COMPONENT DESC: EPIRB
Condition: Improper/Lack of Maintenance
Due 11 May 2002
Resolved 11 April 2002
Accommodation/Occupational Safety
Issued 27 March 2001 Resolved
Emergency escape hatch is to be marked "Emergency Exit Do Not Block."
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Construction/Loadline
Issued 27 March 2001 Resolved
Secure deck hatches (forepeak and Lazerette).
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Engineering
Issued 27 March 2001 Resolved
Repair manual Hydraulic system leak in Engine Room.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Documentation
Issued 27 March 2001 Resolved
Provide CPR Certification for Licensed Crew.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Engineering
Issued 27 March 2001 Resolved
Replace generator exhaust elbow.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Engineering
Issued 27 March 2001 Resolved
Repair exhaust leak upper end of main generator.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 27 March 2001 Resolved
Provide splint for First Aid Kit.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 27 March 2001 Resolved
Provide speaker in berthing for General Alarm System.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Lifesaving
Issued 27 March 2001 Resolved
Generator did not shut down during emergency shutdown. Repair as necessary.
Condition: Unknown
Due 27 March 2001
Resolved 5 April 2001
Documentation
Issued 27 March 2001 Resolved
Provide FCC Operator's Licenses as required.
Condition: Unknown
Due 5 April 2001
Resolved 6 April 2001
Engineering
Issued 27 March 2001 Resolved
Replace exhaust insulation on both main engines.
Condition: Unknown
Due 5 April 2001
Resolved 6 April 2001
Lifesaving
Issued 27 March 2001 Resolved
Properly mark PFD stowage IAW 46CFR 185.604.
Condition: Unknown
Due 5 April 2001
Resolved 5 April 2001
Construction/Loadline
Issued 25 January 2001 Resolved
Provide proper bulkhead penetrations for PVC piping systems.
Condition: Unknown
Due 1 February 2002
Resolved 11 April 2003
Lifesaving
Issued 25 January 2001 Resolved
Provide a damage control kit consisting of a mallet, various sized cone plugs, and oakum in a labled container. Kit is to be stored in an accessible area above the bulkhead deck.
Condition: Unknown
Due 14 August 2001
Resolved 14 August 2001
Electrical
Issued 23 March 2000 Resolved
Remove wire nuts from bait pump motor._x001C_
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 23 March 2000 Resolved
Post operating instructions for fixed fire system in engine room._x001C_
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Navigation
Issued 23 March 2000 Resolved
Free up frozen streeing ram pins and repair ram brackets._x001C_
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Documentation
Issued 23 March 2000 Resolved
Post MARPOL trash plan._x001C_
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Fire Fighting
Issued 23 March 2000 Resolved
Install proper vent closures for engine room vents._x001C_
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Engineering
Issued 23 March 2000 Resolved
renew flame screen on fuel vent line._x001C_
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Lifesaving
Issued 23 March 2000 Resolved
Renew eye wash in frist aid kit._x001C_
Condition: Unknown
Due 23 April 2000
Resolved 10 April 2000
Documentation
Issued 30 March 1999 Resolved
Log all drills in ship's log book.
Condition: Unknown
Due 6 April 1999
Resolved 29 April 1999
Construction/Loadline
Issued 30 March 1999 Resolved
Label bilge maniforld.
Condition: Unknown
Due 6 April 1999
Resolved 29 April 1999
Documentation
Issued 8 April 1992 Resolved
PROVIDE ALL REQUIRED RADIO EQUIPMENT OUTLINED IN 47 CFR 80.905(a)(3), OR OBTAIN AN EXEMPTION FROM THE FCC. VESSEL ROUTE LIMITED TO NOT MORE THAN 100 MILES OFF THE MAINLAND SHORE.
Condition: Unknown
Due 8 April 1992
Resolved 8 April 1992
Accommodation/Occupational Safety
Issued 14 May 1990 Resolved
PROPERLY ATTACH LOCKING CHAIN DEVICES TO BOTH OVERBOARD DISCHARGE VALVES FOR THE VESSEL'S TYPE III MARINE SANITATION DEVICES.
Condition: Unknown
Due 14 May 1990
Resolved 14 May 1990
Navigation
Issued 16 March 1989 Resolved
PROVIDE A CURRENT DEVIATION CARD FOR THE MAGNETIC COMPASS.
Condition: Unknown
Due 16 March 1989
Resolved 16 March 1989
Unknown
Issued 22 June 1988 Resolved
INSTALL A COAST GUARD APPROVED MARINE SANITATION DEVICE HOLDING TANK TO PORT TOILET.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988
Electrical
Issued 22 June 1988 Resolved
REPAIR ELECTRICAL WIRING SPLICES BEHIND CONTROL CONSOLE IN THE WHEELHOUSE AND DECK BELOW THE WHEELHOUSE WITH METAL CRIMP CONNECTORS OR SOLDER.
Condition: Unknown
Due 22 June 1988
Resolved 22 June 1988

Casualty record · 1

20 September 2008Routine · role: Involved in a Marine Casualty · activity 3330485
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.