LAHAINA PRINCESS

Built
1977
Last inspected
10 December 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 December 2025
Operational controls None recorded without a removal date
Years with a record 9 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD6499
Flag
UNITED STATES
Maury page id
psix-49302

Documentation record

Registered dimensions (L × B × D)63.5 ft × 18.4 ft × 7.5 ft
Registered tonnagegross 73 / net 49
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHOMPSON TRAWLERS INC · TITUSVILLE FL, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLAHAINA, HI
Endorsements, as the file codes themcw_un
DocumentationValid · issued 3 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it73 - Regulatory (Subpart C or D), Gross Ton
49 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 18 inspections, each with its date, unit and type; 48 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 18

10 December 2025 Deficiency Check · Vessel Attendance · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8267611
24 October 2024 COI Inspection · DAPI Audit · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 8015814
29 January 2024 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7857290
9 November 2022 Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7592283
27 October 2022 Drydock Exam
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7558379
20 January 2022 Deficiency Check · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7383393
16 November 2021 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7352499
14 January 2021 Annual Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7124557
2 November 2020 Drydock Exam · Examination of Repairs
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 7088601
23 October 2019 COI Inspection · DAPI Audit · Deficiency Check · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6844191
31 October 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6572265
17 October 2018 Administrative Inspection · Drydock Exam · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6562769
9 April 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6388346
30 March 2018 Administrative Inspection
Administrative · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6382236
24 January 2018 Administrative Inspection · Annual Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6343902
20 January 2017 Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6073789
31 October 2016 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 6032651
26 January 2016 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Honolulu · USCG Oceania District (CGD-O) · Activity 5804059

Deficiency record · 48

13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 December 2025 Resolved
This part contains requirements for the design, construction, installation, and operation of propulsion and auxiliary machinery, piping and pressure systems, steering apparatus, and associated safety systems. Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. Vessel’s generator had a fuel leak on the fuel line four feet from the generator and at the connection of the mechanical fuel pump mounted on the engine block. Repair leaks and satisfactory test run the generator in the presence of the attending marine inspector. 46 CFR 182.100
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2025
Resolution: Attended vessel and witness operation of the generator. No observed fuel leaks.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 December 2025 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable to determine that the vessel and its equipment are suitable for the service in which they are to be employed. Pre-engineered fixed gas fire system not tested due to generator fuel leak. Satisfactory test pre-engineered fixed gas fire extinguishing system in the presence of the attending marine inspector. 46 CFR 176.840
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2025
Resolution: Attended vessel and witnessed satisfactory testing of the pre-engineered fixed gas fire extinguishing system.
04 - Emergency Systems › N/A - No Subsystem › Man Overboard Drill (MOB)
Issued 10 December 2025 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that an abandon ship or man overboard drill be held under simulated emergency conditions specified by the inspector. Man overboard drill not conducted due to not testing the pre-engineered fixed gas fire extinguishing system. Upon successful testing of the pre-engineered fixed gas fire extinguishing system, conduct man overboard drill in the presence of the attending marine inspector. 46 CFR 176.808(g)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2025
Resolution: Attended vessel and witnessed a satisfactory man overboard drill.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 December 2025 Resolved
At each initial and subsequent inspection for certification, the marine inspector may require that a fire drill be held under simulated emergency conditions to be specified by the inspector. Fire drill not conducted due to not testing the pre-engineered fixed gas fire extinguishing system. Upon successful testing of the pre-engineered fixed gas fire extinguishing system, conduct fire drill in the presence of the attending marine inspector. 46 CFR 176.810(d)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 December 2025
Resolution: Attended vessel and witnessed a satisfactory fire drill.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 10 December 2025 Resolved
S and L. Each major generator and motor shall be fitted with a nameplate of corrosion-resistant material marked with the following information as applicable: (1) Name of manufacturer. (2) Manufacturer's type and frame designation. (3) Output in KW of watts or horsepower rating. (4) Kind of rating (continuous, intermittent, etc.). (5) Revolutions per minute at rated load.(6) Amperes at rated load. (7) Voltage. (8) Frequency if applicable. (9) Number of phases, if applicable. (10) Type of winding (for direct-current motors). Vessel generator nameplate is missing. Provide generator nameplate with the information described above to the satisfaction of the attending marine inspector. 46 CFR 183.10-5(a) (Old-T)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 11 December 2025
Resolution: Attended vessel and the MI was provide a photograph of the generator data plate due to the location being on the backside of the generator unit.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 December 2025 Resolved
Fuses must be of the cartridge type only and be listed by Underwriters Laboratories or another independent laboratory recognized by the Commandant. New installation of blade type fuses mounted on lower aft inboard pantry partial wall. Replace with the correct amperage UL cartridge type fuses to the satisfaction of the attending marine fuses. 46 CFR 183.380(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 11 December 2025
Resolution: Attended vessel and sighted a new cartridge type fuse holder with the correct amperage UL approved cartridge fuses installed.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 10 December 2025 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. The vessel’s Radiotelephony Certificate was expired. Renew and have onboard to the satisfaction of the attending marine inspector. 46 CFR 184.502
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 18 December 2025
Resolution: Received email from vessel owner with the new Safety Radiotelephony Certificate.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 December 2025 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 11 December 2025
Resolution: Attended vessel and sighted hard copies of the missing navigation publications.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 December 2025 Resolved
The discharge ends of vent pipes shall be fitted with removable flame screens or flame arresters. The flame screens shall consist of a single screen of corrosion resistant wire of at least 30x30 mesh. The port side flame screen mesh was damaged and needs to be renewed to the satisfaction of the attending marine inspector. 46 CFR 182.15-35 (d) Old T
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 11 December 2025
Resolution: Attended vessel and insepcted the new fuel screen installed correctly on the fuel tank vent.
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 10 December 2025 Resolved
A vessel is inspected for compliance with the standards required by this subchapter. Machinery, equipment, materials, and arrangements not covered by standards in this subchapter may be inspected in accordance with standards acceptable to the cognizant OCMI as good marine practice. The port side main engine fuel return lines and the starboard fuel line coming off the manifold and filter were wasted and need to be renewed in kind to the satisfaction of the attending marine inspector. 46 CFR 176.800 (a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 19 December 2025
Resolution: Received email from vessel owner, Dave with photographs of the new fuel hose purchase receipt. On December 21, 2025, received photographs of the new fuel hose installation.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 December 2025 Resolved
The number and identification of the items stowed inside, and their sizes, must be marked in clearly legible letters and numbers on each container for life jackets and immersion suits. Vessel carries extended size range lifejackets. Extended range life jackets are not clearly marked. Mark as described below. 1) LIFEJACKETS (or IMO Symbol for Lifejacket), for persons over (blank) inches (or lb.)" or 2)Additional suggested marking at the stowage location is a line inches (same number of inches as above paragraph) above the deck with the text: "Children shorter than this line must use Child-size Life Preservers", to the satisfaction of the attending marine inspector. 46 CFR 185.604(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 December 2025
Resolved 14 January 2026
Resolution: Received email from vessel rep. with photographs of the new extended life jackets placards posted.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 17 April 2024 Resolved
No major repairs or alterations affecting the safety of the vessel with regard to the hull, machinery, or equipment, shall be made without the knowledge and approval of the OCMI, Marine Inspection. Stbd main engine had a crack in the salt water cooling piping elbow. Replace the elbow in kind and prove proper operation in the presence of attending marine inspector. 46 CFR 176.20-1
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
Resolution: Replaced cracked pipe in kind and tested engine with no leaks.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 29 January 2024 Resolved
The following spaces must be equipped with a fixed gas fire extinguishing system, in compliance with § 181.410, or other fixed fire extinguishing system specifically approved by the Commandant. A space containing propulsion machinery. The engine starts while fire-boy is disconnect, solenoid timing is out. Repair and demonstrate proper function to the satisfaction of attending Coast Guard Marine Inspector. 46 CFR 181.400(a)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
Resolution: Vessel demonstrated proper operation of fireboy system.
09 - Working and Living Conditions › 091 - Living Conditions › Furnishings
Issued 29 January 2024 Resolved
No major repairs or alteration affecting the safety of the vessel with regard to the hull, machinery or equipment shall be made without the knowledge and approval of the Officer in charge, Marine Inspections. Seats and tables on upper deck must be secured utilizing through bolts. 46 CFR 116.820(b)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
Resolution: Seating and tables were secured to deck with thru bolts.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 29 January 2024 Resolved
For a buoyant apparatus—Approved under approval series 160.010. The color of the buoyant apparatus must be primarily vivid reddish orange. Each buoyant apparatus must have Type II retroreflective material meeting subpart 164.018 of this chapter on each side and end. 46 CFR 180.200(a)(1) 46 CFR 160.010-4(n), (p)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
Resolution: Life floats were restored back to original color and retro material was renewed.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 29 January 2024 Resolved
At each initial and subsequent inspection for certification the marine inspector shall examine and test the following items to the extent necessary to determine that they are in proper operating condition, safe electrical condition, and fit for the service for which they are intended. Lighting installed in engine room inoperable. Provide adequate lighting in engine room. 46 CFR 176.25-15 (a)
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 17 April 2024
Resolution: Engine room lighting was restored.
07 - Fire Safety › N/A - No Subsystem › Fire pumps and its pipes
Issued 20 January 2022 Resolved
The minimum capacity of the power fire pump shall be 50 gallons per minute at a pressure of not less than 60 pounds per square inch at the pump outlet. The pump outlet shall be fitted with a pressure gage. During operational test of fire pump, pump would not make pressure shaft just spun. Make 60 psi in presence of attending Marine Inspector. 46 CFR 181.10-1 (e)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2022
Resolved 21 January 2022
Resolution: Witnessed proper operation of the fire pump via charged fire hose producing adequate pressure and stream from the aft deck.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 20 January 2022 Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. 46 CFR 182.500(a)
Action required: 17 - Rectify deficiencies prior to departure
Due 20 January 2022
Resolved 21 January 2022
Resolution: Tested the installed bilge system by pumping water from the forepeak and aux space OVBD.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machines/parts
Issued 20 January 2022 Resolved
An exposed hazard, such as gears or rotating machinery, must be properly protected by a cover, guard, or rail. Alternator on Port & STBD engines missing belt guard. 46 CFR 177.960
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 21 January 2022
Resolution: Verified installation of protective guards on both main engines.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 20 January 2022 Resolved
Life floats and buoyant apparatus must not be stowed in tiers more than 1,220 millimeters (4 feet) high. When stowed in tiers, the separate units must be kept apart by spacers. Insert spacers in between Life floats. 46 CFR 180.137(f)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 3 February 2022
Resolved 21 January 2022
Resolution: Verified installation of spacers between life floats.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2021 Resolved
Upper deck passenger limit not posted at entranceway to upper deck. Provide marking at both sets of stairs showing 47 passengers authorized on upper deck at entranceway to the upper deck.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 22 January 2021
Resolution: Markings posted
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2021 Resolved
Port side main engine turbo outlet has expansion joint attached by band clamps. The connection is slipping. Provide sure connection of expansion joint with two clamps.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 22 January 2021
Resolution: Connection provided.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 January 2021 Resolved
Fire main gauge numbers worn. Provide legible gauge to ensure adequate fire main pressure.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 22 January 2021
Resolution: Gauge replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 14 January 2021 Resolved
Drug and alcohol hot-line numbers not posted in common space. Provide drug and alcohol telephones in common space.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2021
Resolved 15 January 2021
Resolution: Number posted.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 23 October 2019 Resolved
Fixed extinguishing system did not secure generator when tested. Prove correct operation in accordance with 46 CFR 176.810.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2019
Resolved 12 November 2019
Resolution: Generator secured upon activation of installed system.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 23 October 2019 Resolved
Port engine outer turbo oil drain was leaking. Repair leak and clean/renew lagging in accordance with 46 CFR 176.804.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 7 November 2019
Resolved 12 November 2019
Resolution: Lagging was free of oil and leak repaired.
Fire Fighting › Miscellaneous Items › Insulation (Penetration of Oil/Oil Vapors)
Issued 20 January 2017 Resolved
Replace Exhaust lagging on both MDE's
Due 20 February 2017
Resolved 20 January 2017
Resolution: Exhaust lagging was replaced.
Construction/Loadline › Structures › Deck Plating
Issued 20 January 2017 Resolved
Engine room deck plates need replaced.
Due 20 February 2017
Resolved 24 January 2017
Resolution: Deck plates were replaced.
Navigation › Piloting/Steering › Magnetic Compass
Issued 20 January 2017 Resolved
Ensure compass light is operational prior to night operations.
Due 20 February 2017
Resolved 24 January 2017
Resolution: Compass light is operational.
Engineering › Steering Gear System › Hand Pump
Issued 20 January 2017 Resolved
Repair helm hand pump seal.
Due 20 February 2017
Resolved 12 February 2017
Resolution: Helm pump was rebuilt with new seal kit.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2016 Resolved
Blister in fiberglass on hull on starboard side, forward of bow thruster; provide repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2016
Resolution: Blister in fiberglass on hull on starboard side, forward of bow thruster; repaired.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2016 Resolved
Blister in fiberglass on hull on starboard side, approximately 8 feet aft of bow thruster; provide repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2016
Resolution: Blister in fiberglass on hull on starboard side, approximately 8 feet aft of bow thruster; repaired.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2016 Resolved
Blister in fiberglass on hull on starboard side, approximately 20 feet aft of bow thruster; provide repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2016
Resolution: Blister in fiberglass on hull on starboard side, approximately 20 feet aft of bow thruster; repaired.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2016 Resolved
Blister in fiberglass on hull on port side, forward of bow thruster; provide repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2016
Resolution: Blister in fiberglass on hull on port side, forward of bow thruster; repaired.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2016 Resolved
Blister in fiberglass on hull on port side, approximately one foot aft of bow thruster; provide repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2016
Resolution: Blister in fiberglass on hull on port side, approximately one foot aft of bow thruster; repaired.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2016 Resolved
Blister in fiberglass on hull on port side, approximately 20 feet aft of bow thruster; provide repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2016
Resolution: Blister in fiberglass on hull on port side, approximately 20 feet aft of bow thruster; repaired.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2016 Resolved
Blister in fiberglass on hull on port side, near shaft strut; provide repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 2 November 2016
Resolution: Blister in fiberglass on hull on port side, near shaft strut; repaired.
Construction/Loadline › Structures › Deck Plating
Issued 31 October 2016 Resolved
Area surrounding hawsepipe for anchor line in fore peak saturated with water, inner core of fiberglass layup contains wood rot, provide repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Due 30 November 2016
Resolved 24 November 2016
Resolution: Area surrounding hawsepipe for anchor line in fore peak saturated with water; inner core of fiberglass layup wood rot repaired.
Construction/Loadline › Structures › Deck Plating
Issued 31 October 2016 Resolved
wood rot noted on panel in tank void, forward of engine compartment, provide repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Due 1 November 2016
Resolved 24 November 2016
Resolution: wood rot noted on panel in tank void, forward of engine compartment, repaired.
Construction/Loadline › Hull › Longitudinal Frame
Issued 31 October 2016 Resolved
Noted various longitudinal and transversal beams and panels throughout voids exhibiting angel hair, clean to good wood and repair.
Condition: Improper/Lack of Maintenance
Due 1 November 2016
Resolved 24 November 2016
Resolution: Various longitudinal and transversal beams and panels throughout voids exhibiting angel hair, cleaned to good wood and repaired.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2016 Resolved
Noted areas around all vents in engine compartment exhibiting dry rot; repair
Condition: Improper/Lack of Maintenance
Due 1 November 2016
Resolved 24 November 2016
Resolution: Noted areas around all vents in engine compartment exhibiting dry rot; repaired.
Construction/Loadline › Hull › Longitudinal Frame
Issued 31 October 2016 Resolved
Noted longitudinal beam on port side of engine compartment cracked; provide repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Due 1 November 2016
Resolved 24 November 2016
Resolution: Noted longitudinal beam on port side of engine compartment cracked; repaired.
Construction/Loadline › Hull › Transverse Frame
Issued 31 October 2016 Resolved
Noted extensive wood rot on transversal beam on port side of engine compartment.
Condition: Improper/Lack of Maintenance
Due 1 November 2016
Resolved 24 November 2016
Resolution: Repiared wood rot on transversal beam on port side of engine compartment.
Construction/Loadline › Hull › Transverse Frame
Issued 31 October 2016 Resolved
Noted extensive wood rot on transversal beams in engine compartment forward of engines on both port and starboard sides; provide repair proposal and repair accordingly.
Due 1 November 2016
Resolved 24 November 2016
Resolution: Wood rot on transversal beams in engine compartment forward of engines on both port and starboard sides; repaired.
Construction/Loadline › Structures › Deck Plating
Issued 31 October 2016 Resolved
Noted dry rot near hatch openings in aft compartments around previously installed hatches and associated cracking in the above FRP deck; submit repair proposal and repair accordingly.
Condition: Improper/Lack of Maintenance
Due 1 November 2016
Resolved 24 November 2016
Resolution: Dry rot near hatch openings in aft compartments around previously installed hatches and associated cracking in the above FRP deck; repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 October 2016 Resolved
Noted crack on bottom of starboard side ladder railing, repair accordingly.
Condition: Improper/Lack of Maintenance
Due 1 November 2016
Resolved 24 November 2016
Resolution: Crack on bottom of starboard side ladder railing, repaired.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 31 October 2016 Resolved
Noted crack on topside of port side ladder rail, repair accordingly.
Condition: Improper/Lack of Maintenance
Due 1 November 2016
Resolved 24 November 2016
Resolution: Crack on topside of port side ladder rail, repaired.
Construction/Loadline › Hull › Hull Plating
Issued 31 October 2016 Resolved
Noted extensive dry rot in wood doubler located aft on overhead of fore peak void. Submit repair proposal and reapair accordingly.
Condition: Improper/Lack of Maintenance
Due 1 November 2016
Resolved 24 November 2016
Resolution: Dry rot in wood doubler located aft on overhead of fore peak void repaired.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.