APACHE

Built
1977
Last inspected
18 September 2018
Documentation
Expired · NVDC file of 10 August 2026
Controls
1 with no removal date recorded

This record may be incomplete: the most recent inspection recorded for this vessel was 8 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 18 September 2018
…past their stated due date5
Operational controls 1 with no removal date recorded
Years with a record 3 calendar years (2016–2018)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDD4597
Flag
UNITED STATES
Maury page id
psix-49307

Documentation record

Registered dimensions (L × B × D)95.3 ft × 26.0 ft × 7.0 ft
Registered tonnagegross 99 / net 67
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA W COVACEVICH · BILOXI, MS, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portSAN LEON, TX
Endorsements, as the file codes themcw_un
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 6 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each, 5 without one; 1 operational control with no removal date recorded; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 6

18 September 2018 Internal Structural Exam · Deficiency Check · Administrative Inspection · Drydock Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 6543506
31 July 2018 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 6495295
1 March 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6364144
6 July 2017 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 6199921
21 June 2016 Annual Inspection · Drydock Exam · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 5914079
14 March 2016 Administrative Inspection · Drydock Extension
Administrative · Marine Safety Unit Lake Charles · USCG Heartland District (CGD-H) · Activity 5833079

Deficiency record · 15

02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 September 2018 No resolution recorded
The clean oil tank vent located under the sink aft of the superstructure on the main deck is sheared just above the through deck fitting. The pipe must be replaced or removed and capped to comply with watertight integrity requirements.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 24 September 2018 No resolution recorded
The middle port quarter vent outlet is severely corroded, with multiple holes visible. The vent must be replaced to comply with watertight integrity requirements.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 September 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2018 Resolved
Prove proper operation of fuel shutdowns. Current arrangement (pull cable) is seized.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2018
Resolution: New cable installed and tested satisfactorily
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2018 Resolved
Provide proper relief valve for air receiver. Current relief valve will not reset.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 16 August 2018
Resolution: Relief valve in place and tested by pulling on relieve tab and reset appropriately
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 July 2018 Resolved
Provide proper waterlights/batteries for all 3 lifefloats and life buoy. During float test all 4 waterlights fully submerged due to battery weight.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2018
Resolution: New lights/batteries in place
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 July 2018 Resolved
Properly secure lifefloat paddles. Paddles are not currently secured.
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2018
Resolution: Paddles were secured with line
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 31 July 2018 Resolved
Properly secure the lifefloat painters to the lifefloats. The painters are currently attached by a lanyard clip to the grab lines.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 16 August 2018
Resolution: Painters properly secured
14 - Pollution Prevention › 145 - MARPOL Annex V › Garbage management plan
Issued 31 July 2018 Resolved
Provide proper waste management plan. Existing plan allows for unground food waste to go over the side outside of 12 miles from shore.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 16 August 2018
Resolution: New and proper waste management plan posted
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 31 July 2018 Resolved
Provide appropriate portable fire extinguisher service report. Last report was April 2017.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 16 August 2018
Resolution: All portable were inspected/maintenanced by appropriate 3rd party
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2018 Resolved
Provide proper battery connections (permanent). Connections currently done with wing nuts.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 16 August 2018
Resolution: Proper connections are made
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2018 Resolved
Provide drip shields for battery chargers located in the engine room/ There is currently no protection
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018
Resolved 16 August 2018
Resolution: Dip shield in place
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 31 July 2018 No resolution recorded
Make permanent repairs to holed potable waterline
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 31 July 2018 No resolution recorded
replace hydraulic hoses (pump and ram) on steering system. Current hoses are deteriorated.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018 — due date passed with no resolution recorded
02 - Structural Conditions › N/A - No Subsystem › Decks - cracking
Issued 31 July 2018 No resolution recorded
Make permanent repair to deck plating in way of the engineroom 3ft from aft bulkhead (fwd) 4ft port side of the centerline. Currently there is a softpatch
Action required: 50 - Rectify deficiencies w/in 30 days
Due 31 August 2018 — due date passed with no resolution recorded
Operations/Management › Drug and Alcohol Testing › Testing, Pre-employment
Issued 6 July 2017 Resolved
No current drug and alcohol program inspection (DAPI) currently being utilized. Have all employees enrolled in the chemical testing program IAW the CFR.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Due 6 August 2017
Resolved 12 July 2017
Resolution: received and accepted drug testing documentation for the operator/crew.