This record may be incomplete: the most recent inspection recorded for this vessel was 33 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard.
Every line above is a count of records the US Coast Guard wrote, or a date it recorded.
A blank resolution means none was recorded in this data; it does not establish that a
deficiency is outstanding. Years with a record are calendar years in which a record
exists, not years in service. What Maury does
not do.
1053 - Regulatory (Subpart C or D), Gross Ton
1053 - Regulatory (Subpart C or D), Net Ton
Maury page id
psix-49309
Vessel history report
Every record for this hull, in one document — $299
Every recorded inspection, 1972 to
2026, in one chronology · every deficiency, with system, dates
and resolution · operational controls imposed and removed · every name this
hull has been recorded under · the vessels it was inspected alongside, and when
· how its record compares with hulls of similar age and size, as a fact about the
population and never a judgement about this vessel.
This report is in development and is not for sale yet. There is
no date, and nothing is charged. Leave an email and we will tell you when it exists, once.
Used only to tell you when the report exists.
Not shared, not sold, and not added to a mailing list.
Inspection history · 32
8 December 1993Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1159476
3 June 1993Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1444721
24 May 1993Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 486518
18 May 1993Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417510
20 March 1992COI Inspection · Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 946619
18 September 1991Type not recorded
No type recorded · MSO Paducah · USCG Heartland District (CGD-H) · Activity 469056
DEWATER STERN VOID AND MAKE AVAILABLE FOR INTERNAL INSPECTION, BY CG _x001C_ INSPECTOR
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Documentation
Issued 18 May 1993Resolved
PROVIDE BENZENE REDUCTON PROGRAM IAW 46 CFR 197
Condition: Unknown
Due 11 June 1993
Resolved 18 May 2002
Resolution: MISLE Maintenance - Resolved all open deficiencies issued prior to 6/1/1997 where activity was closed and deficiency due date was past
Deck/Cargo
Issued 18 May 1993Resolved
RENEW FLAME SCREENS IN P/V VALVE FOR SLOP TANK.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Engineering
Issued 18 May 1993Resolved
REPAIR HYDROTOR, STARTER LEAK FOR CARGO PUMP ENGINE.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Deck/Cargo
Issued 18 May 1993Resolved
MAKE ALL CARGO VALVE REACH RODS VAPOR TIGHT.
Condition: Unknown
Due 18 May 1993
Resolved 18 May 1993
Deck/Cargo
Issued 12 June 1991Resolved
PRIOR TO LOADING CARGO REPACK ALL REACH RODS.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Construction/Loadline
Issued 12 June 1991Resolved
MAKE PERMANENT REPAIRS TO THE PORT BOW DOUBLE POST BIT.
Condition: Unknown
Due 12 June 1991
Resolved 12 June 1991
Deck/Cargo
Issued 25 April 1990Resolved
THE DECK SLOP TANK REQUIRES A PV VALVE BECAUSE GRADE "B" AND LOWER CARGOES ARE CARRIED. INSTALL A PROPER PV VALVE TO THE SATISFACTION OF THE ATTENDING U.S.C.G. MARINE INSPECTOR.
Condition: Unknown
Due 25 April 1990
Resolved 25 April 1990
Construction/Loadline
Issued 8 September 1986Resolved
MAINTAIN TEMPORARY REPAIRS TO TWO FRACTURES, ONE EACH IN THE BOW AND STERN VOIDS AT THE TWO FOOT DRAFT MARKS. PRIOR TO LOADING THE BARGE MAKE PERMANENT REPAIRS TO THESE FRACTURES. ALL REPAIRS TO BE MADE TO THE SATISFACTION OF THE COGNIZANT OCMI.
Condition: Unknown
Due 8 September 1986
Resolved 8 September 1986
Unknown
Issued 7 September 1986Resolved
MAKE THE BARGE AVAILABLE FOR A DAMAGE SURVEY BY A CG MARINE INSPECTOR UPON ARRIVAL IN HOUSTON, TEXAS, MARINE INSPECTION ZONE. NO CARGO ONLOADINGIS TO OCCUR UNTIL THE REQUIREMENT HAS BEEN COMPLETED.
Condition: Unknown
Due 7 September 1986
Resolved 7 September 1986