MAURY USCG vessel records Sign in
← All vessels

VIKING STARSHIP

VIKING STARSHIP is a 1977 passenger vessel (inspected). The Coast Guard has recorded 115 inspections since 1985, most recently in April 2026, along with 361 deficiencies, 1 operational control and 2 casualty investigations between 2019 and 2024.

Records from 1985 to 2026. Most recent: inspection, 8 April 2026.

Built
1977
Last inspected
8 April 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDH8814
Flag
UNITED STATES
367661740
Maury page id
psix-49315

Inspections, by type

…with no type recorded18
Years with a record 38 calendar years (1985–2026)
The 115 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)117.4 ft × 25.0 ft × 7.0 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN, RI, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMONTAUK, NY
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 24 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDH8814MMSI 367661740 · active · compulsorily equipped · granted 11 April 2025, expires 17 March 2035
WDB6375MMSI 366923420 · expired · compulsorily equipped · granted 4 February 2004, cancelled 5 March 2014
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 115

8 April 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8344906
20 January 2026 Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8299392
5 February 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8070425
30 September 2024 Examination of Repairs · Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8011748
30 September 2024 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8011850
5 September 2024 Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 7997335
4 April 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7889521
8 February 2024 Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7853532
22 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7852649
14 March 2023 Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7650710
22 November 2022 Deficiency Check · DAPI Audit · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7580487
25 June 2022 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7499705
25 March 2022 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411307
9 February 2022 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7390889
2 February 2022 Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7389569
12 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7257098
24 November 2020 Administrative Inspection · Deficiency Check · Examination of Repairs · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7100650
16 January 2020 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6885094
18 November 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6841896
28 October 2019 Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6843514
10 October 2019 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6831935
15 August 2019 Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6785113
12 August 2019 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6811009
20 November 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6571778
17 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6542248
7 February 2018 Hull Examination · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6353622
30 November 2017 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6311383
21 November 2017 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6294321
21 February 2017 Type not recorded
No type recorded · USCGC ALBACORE (WPB 87309) · USCG Northeast District (CGD-NE) · Activity 6282046
13 December 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6056125
26 February 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5843481
2 February 2016 Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5811960
17 November 2015 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5764103
9 June 2014 Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 4883954
17 December 2010 Examination of Repairs · Drydock Exam · Deficiency Check · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3912480
30 November 2010 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3900087
19 February 2010 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3734908
17 December 2009 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3651660
22 January 2009 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3395397
6 January 2009 Internal Structural Exam · Deficiency Check · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 3386336
3 February 2008 Type not recorded
No type recorded · USCGC CHINOOK (WPB 87308) · USCG Heartland District (CGD-H) · Activity 3142322
26 November 2007 COI Inspection · Deficiency Check · MTSA/ISPS Verification · MARPOL Annex V Examination
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 3104226
30 October 2006 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2810831
13 October 2005 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 2513094
16 December 2004 Hull Examination
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2259698
24 November 2004 Drydock Extension
Administrative · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2247298
3 November 2004 Deficiency Check · In-Service Inspection
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 2235509
21 October 2004 MTSA Verification · Annual Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 2219986
26 January 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 1997744
6 January 2004 Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1976677
24 November 2003 Annual Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1953201
11 September 2003 Deficiency Check
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1902631
20 May 2003 Examination of Repairs · Deficiency Check
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1788730
27 November 2002 MARPOL Annex V Examination · COI Inspection
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1709543
20 November 2002 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1704179
7 February 2002 Re-Inspection · MARPOL Annex V Examination
Physical examination · MSFO LONG ISLAND · USCG Northeast District (CGD-NE) · Activity 1475228
28 January 2002 Examination of Repairs
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1481743
8 June 2001 Excursion Permit
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1065762
15 March 2001 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1066819
9 February 2001 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1462212
12 January 2001 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1058693
17 November 1999 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1384312
26 August 1999 Excursion Permit
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1121582
17 August 1999 Type not recorded
No type recorded · USCGC NORTHLAND (WMEC 904) · Activity 1512918
13 August 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 65183
30 May 1999 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 45474
10 February 1999 Re-Inspection · MARPOL Annex V Examination · Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1473037
3 February 1999 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1473358
26 April 1998 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 793348
11 December 1997 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1113954
10 December 1997 MARPOL Annex V Examination · Deficiency Check · Re-Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 777407
24 November 1997 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1428861
28 July 1997 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 784053
28 July 1997 Administrative
Administrative · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 1122440
11 June 1997 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 80995
22 January 1997 Deficiency Check
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1104185
16 December 1996 Deficiency Check · Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1100240
27 November 1996 MARPOL Annex V Examination · COI Inspection
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 874093
12 September 1996 Deficiency Check
Physical examination · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 953837
20 July 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 59841
20 July 1996 Type not recorded
No type recorded · GROUP/MSO LONG ISLAND SOUND · USCG Northeast District (CGD-NE) · Activity 214422
6 March 1996 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1421084
1 December 1995 Deficiency Check · Examination of Repairs
Physical examination · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 1358980
7 July 1995 Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1186263
10 May 1995 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1344654
9 March 1995 COI Inspection
Physical examination · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1382922
16 December 1994 Type not recorded
No type recorded · MSO SAN JUAN · USCG Southeast District (CGD-SE) · Activity 1450922
30 March 1994 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1171688
11 March 1994 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1448511
25 September 1993 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 74110
10 March 1993 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1143266
31 March 1992 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 958302
6 January 1992 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1269083
15 January 1991 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 931278
11 January 1991 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1234140
10 April 1990 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1231089
21 March 1990 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 932801
3 January 1990 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 918358
20 December 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1215295
1 November 1989 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1286846
6 September 1989 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1200040
2 February 1989 COI Inspection · Deficiency Check
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1038088
19 April 1988 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1339965
12 April 1988 Deficiency Check · COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 889280
7 March 1988 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1028795
28 April 1987 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1327339
31 March 1987 Hull Examination
Physical examination · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1019340
13 March 1987 Administrative
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1322553
12 September 1986 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1000260
1 July 1986 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1294627
4 June 1986 Excursion Permit
Administrative · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1303543
12 May 1986 COI Inspection
Physical examination · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 995754
31 January 1986 Type not recorded
No type recorded · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1293402
31 January 1986 Credit Drydock
Administrative · MSO PROVIDENCE · USCG Northeast District (CGD-NE) · Activity 1293403
15 May 1985 Type not recorded
No type recorded · ACTIVITIES NEW YORK · USCG Northeast District (CGD-NE) · Activity 1290210

Deficiency record · 361

09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 8 April 2026 Resolved
Renew engine room emergency exit signage with new glow in the dark reflective lettering
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2026
Resolved 20 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2026 Resolved
Repair exhaust lagging on starboard side MDE outboard of elbow.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 April 2026
Resolved 9 April 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 20 January 2026 Resolved
Repair broken window on starboard main deck
Action required: 15 - Rectify deficiencies by next port
Resolved 23 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 February 2025 Resolved
REPLACE LAGGING ON MDE EXHAUST.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 February 2025
Resolved 5 February 2025
Resolution: CORRECTED ON THE SPOT
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 5 February 2025 Resolved
PROPERLY MOUNT AND PLACE COVERS ON ELECTRICAL OUTLETS IN FWD BERTH AND FWD ACCOMODATION AREAS.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 11 February 2025
Resolution: ITEMS CORRECTED
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 February 2025 Resolved
REPLACE BATTERY IN FLOATLIGHT.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 11 February 2025
Resolution: BATTERY WAS REPLACED
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 September 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Received report that the vessel's stbd shaft is broken and they are transiting from Montauk, NY to Goodison Shipyard in North Kingstown, RI for repairs. Prior to carrying passenger or cargo, complete repairs and conduct a sea trial to the satisfaction of the Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2024
Resolved 16 October 2024
Resolution: See Activity Number 8011748.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2024 Resolved
Provide spanner wrenches at P/S fire stations.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2024
Resolved 16 April 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 April 2024 Resolved
Provide ships bell
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2024
Resolved 16 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2024 Resolved
Renew fire extinguisher showing required recharge.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2024
Resolved 4 April 2024
Resolution: Corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2024 Resolved
A vessel must be fitted with ground tackle necessary for the vessel to be safely anchored or moored. Renew the identified wasted anchor winch support frames to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 February 2024 Resolved
Each window must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel. Replace 02 cracked windows on the stbd side main deck fwd. 46 CFR 177.1020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 February 2024 Resolved
There must be no protrusions in means of escape that could cause injury, ensnare clothing, or damage life jackets. Crop and renew wasted longitudinal located at aft escape hatch in berthing area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 4 April 2024
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 8 February 2024 Resolved
The cognizant OCMI may require that a vessel undergo any additional inspection deemed reasonable and necessary to determine that the vessel is suitable for the service in which they are employed. Clean and descale overhead area adjacent to and outboard of aft berthing hatch and make available for inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 4 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 February 2024 Resolved
Footholds, handholds, and ladders must be suitable for use in emergency conditions, of rigid construction, and permanently fixed in position. Crop and renew escape ladder upper rung in aft berthing area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 February 2024 Resolved
Each door or hatch used as a means of escape, must be capable of being opened by one person in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. The location of the door handle inside of the aft escape hatch is not obvious in dark conditions and no emergency lighting is provided at the starboard outboard escape hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 February 2024 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. The stbd outboard emergency escape hatch from the berthing area is not marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 February 2024 Resolved
The name of the vessel and hailing port must be marked on some clearly visible exterior part of the stern of the vessel. No name or hailing port is visible on the stern.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 December 2022 Resolved
Decommissioned 07 adult PFDs but vessel had extras onboard and remain above the passenger carrying capacity. Deficiency issued and cleared.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 December 2022
Resolved 8 December 2022
Resolution: Vessel had extras onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 December 2022 Resolved
Replace port generator cover
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Port generator cover bolted down
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
Replace battery box cover straps
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Battery box covers strapped down.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
Repair air compressor cover and repair loose electrical connections
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Air compressor cover is tight and electrical connection is covered
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2022 Resolved
Replace port side fire hose prior to carriage of passengers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2023
Resolved 9 December 2022
Resolution: The port side fire hose has been replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
Repair port side forward facing spotlight cover and bulb
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Port side spotlight cover and bulb replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 December 2022 Resolved
Replace broken window on port side in main cabin and aft door
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 16 December 2022
Resolution: Windows have been replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
Replace light switch cover in space aft of wheelhouse
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Light switch cover has been replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 December 2022 Resolved
Replace belt guard on starboard generator
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Belt guard on STB generator repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
Hardwire pump in lazarette as discussed with vessel rep.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 9 December 2022
Resolution: Pump in lazarette has been hardwired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 June 2022 Resolved
A vessel must be fit with ground tackle necessary for the vessel to be safely anchored or moored. During the 2022 drydock the vessel was issued the following worklist item; crop and renew to good metal wasted gunwale and anchor foundation members in way of the bow sprit. Vessel made temporary repairs. Due to the unavailability of a stainless steel welder at the ship yard, the vessel is authorized to complete permanent repairs in it's homeport within the next 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2022
Resolved 25 June 2022
Resolution: MI received proof of repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2022 Resolved
Remove dead end electrical wire in enginroom overhead.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 9 February 2022
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 February 2022 Resolved
Have all fire extinguishers serviced.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2022
Resolved 8 March 2022
Resolution: Received proof of compliance from O/O
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 January 2021 Resolved
Replace belt guards on both Gensets.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2021
Resolved 26 January 2021
Resolution: Belt guards have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 January 2021 Resolved
Relabel bilge manifold.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2021
Resolved 26 January 2021
Resolution: Bilge manifold has been relabelled.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 14 January 2021 Resolved
Replace expired hydrostatic release (Hammer) for Cat1 EPIRB.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 14 January 2021
Resolved 14 January 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 January 2021 Resolved
Label engine room vent closures.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2021
Resolved 14 January 2021
Resolution: corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 January 2021 Resolved
Replace or repair life floats on vessels roof. Several life floats had cracks into the polystyrene.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 15 February 2021
Resolution: Liferafts have been repaired properly.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 January 2021 Resolved
Replace wood paneling where the water lights are mounted. Wood is rotten and can no longer support brackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 31 March 2021
Resolution: Water lights monuted correctly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 January 2021 Resolved
Several windows in passenger cabin are cracked. Discrepancy de
Action required: 705 - Other - as specified
Due 13 February 2021
Resolved 31 March 2021
Resolution: Deferred until next drydock. Added as a special note.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2021 Resolved
Both MDE air intake hoses to the turbo were not correctly attached (hanging by a string/attached by a single hose clamp or wire.) Attach turbo air intake hose correctly.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 26 January 2021
Resolution: Turbo air intake hoses have been secured adequately.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 January 2021 Resolved
Port side lamp in E/R missing guard. Replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 14 January 2021
Resolution: Replaced during inspection
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 January 2021 Resolved
Fire pump gauge would not read beyond 25psi. Require replacement and operational test of fire pump to achieve 60psi.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 26 January 2021
Resolution: Vessel installed a new guage and verified at pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 November 2020 Resolved
The fixed bilge piping system had a constant drip in a section of pipe near the bilge manifold. The area of pipe around the leak was corroded and a small hole had developed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 December 2020
Resolved 24 November 2020
Resolution: The crew replaced the leaking section of pipe within two hours of the deficiency being issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 November 2020 Resolved
The engine room bilges had an excessive amount of oily water in them. Issued a 14 day requirement to pump and clean engine room bilges.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2020
Resolved 14 January 2021
Resolution: Bilges verified clean and dry on this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 November 2020 Resolved
Vessel's stbd side exhaust had a significant leak. Repair exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2021
Resolved 14 January 2021
Resolution: Verified exhaust leak had been repaired. Vsl welded new exhaust and installed new flanges and exhaust lagging on stbd side.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2019 Resolved
Vessel had 02 fire hoses, when tested both leaked throughout the hose and were found un-serviceable. Replaced fire hoses with two, used, fire hoses conforming to UL19 IAW CFR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: Replaced 2 failed fire hoses with inservice hoses from another vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 November 2019 Resolved
Bilge suction pipe in passenger compartment must be fitted with a suitable strainer. Strainer on bilge suction piping was found wasted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
Resolution: Installed strainer.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2019 Resolved
Provide spanner wrenches at each fire station that will fit the fire hose installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2019
Resolved 2 December 2019
Resolution: Installed spanner wrenches.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 November 2019 Resolved
The manufacturer's instructions for onboard maintenance of survival craft must be onboard vessels greater than 65 feet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 2 December 2019
Resolution: Installed manufacturer's instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 November 2019 Resolved
Each survival craft must be inspected monthly using the manufacturer's instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 2 December 2019
Resolution: Logged inspections.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 18 November 2019 Resolved
Receptacle outlets must be installed to prevent improper connection. Outlet in the overnight accommodations was found with a broken plug piece lodged into it and the cover for the recepticle broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
Resolution: Installed outlet cover.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 18 November 2019 Resolved
Verify and prove painter length is 100' after painter was found deteriorated due to exposure to the elements.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: Crew replaced painter line with new life float, float free, painter line assembly.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 November 2019 Resolved
life floats were set up to deploy in clusters where one life float was attached to a painter line and the intent was to connect 2 other life float lines, however there were no lines connecting the life floats together for this type of set up
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: O/O properly installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 October 2019 Resolved
Complete but simple instructions for the operation of the system must be located in a conspicuous place at or near the all pull boxes, stop valve controls and in the CO2 storage room. Vessel did not have accurate operating instructions at the operating station. Ensure accurate operation instructions are posted at the operating station. 46 CFR 181.20-15(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 25 October 2019
Resolution: Proper operating instructions provided.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 October 2019 Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Marine Inspector discovered unapproved electrical outlets installed in overnight accommodations. Remove permanently or provide plans of installation to this office for approval. 46 CFR 176.700(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 25 October 2019
Resolution: Provided electrical plans.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 October 2019 Resolved
All portable fire extinguishers installed on a vessel shall be of an approved type. Numerous portable fire extinguishers on board were not mounted with an approved mounting bracket. Mount portable fire extinguishers with proper brackets. 46 CFR 181.30-5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 25 October 2019
Resolution: fire extinguishers mounted
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 October 2019 Resolved
All escape hatches shall be marked on both sides "Emergency Exist, Keep Clear". Engine room escape was not labeled from the inside. Label appropriately. 46 CFR 185.30-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 25 October 2019
Resolution: poperly labeled
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 October 2019 Resolved
Machinery, and fuel tank spaces shall be separated from the accommodation spaces by watertight and/or vapor tight bulkheads of steel plate and or equivalent construction. Wasted steel bulkhead penetrations found within the engine room emergency escape. Repair bulkhead to original. 46 CFR 182.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 25 October 2019
Resolution: repaired bulkhead for vapor tightness.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 October 2019 Resolved
Dry pipe exhausts are permissible if suitably insulated. Both port and starboard engine exhaust piping missing sections of insulation. Reinstall insulation. 46 CFR 182.20-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 25 October 2019
Resolution: lagging/insulation repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 October 2019 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Starboard generator wiring found loose. Properly secure wiring on generator. 46 CFR 183.01-15(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 15 October 2019
Resolution: wiring secured
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2019 Resolved
Properly install/demonstrate operational readinesss of new shaft assembly
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2019
Resolved 26 August 2019
Resolution: O/O effected all repairs to running gear
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2019 Resolved
Reinstall as original port side intermediate cutlass bearing
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2019
Resolved 26 August 2019
Resolution: O.O installed new cutlass
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 August 2019 Resolved
Reinstall as original local start wiring for port/stbd. generators
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2019
Resolved 26 August 2019
Resolution: O/O reinstalled wiring as original
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 15 August 2019 Resolved
Properly install ladder to machinery space
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2019
Resolved 26 August 2019
Resolution: O/O properly secured new ladder into machinery space
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 August 2019 Resolved
Stitch weld eroded fairing plate aft. transom
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2019
Resolved 26 August 2019
Resolution: O/O conducted permanent reapirs to the overboard discharge
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 November 2018 Resolved
Replace 01 ring life buoy on port side. 46CFR180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2018
Resolved 28 November 2018
Resolution: Provided
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 November 2018 Resolved
Replace/fix emergency lighting in overnight accommodation spaces- 46CFR183.432
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2018
Resolved 28 November 2018
Resolution: Provided
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 November 2018 Resolved
Secure and attach life float lights properly. 46CFR180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2018
Resolved 28 November 2018
Resolution: Provided
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 November 2018 Resolved
Provide lights on PFDs that are equipped properly. 46CFR180.75
Action required: 10 - Deficiency Rectified
Due 20 November 2018
Resolved 20 November 2018
Resolution: Corrected on spot
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 September 2018 Resolved
Vsl is broadcasting greater than expected vessel length, Vsl is broadcasting no static draft information and Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 27 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Construction/Loadline › Hull › Hull Plating
Issued 7 February 2018 Resolved
Crop & Renew wasted aft deck (P & S), where UT readings are below .187
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 6 June 2018
Construction/Loadline › Hull › Hull Plating
Issued 9 January 2018 Resolved
Conduct permanent repairs to all doublers as directed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2018
Resolved 22 May 2018
Construction/Loadline › Hull › Hull Plating
Issued 9 January 2018 Resolved
Conduct permanent repairs to aft deck as directed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2018
Resolved 22 May 2018
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 9 January 2018 Resolved
Conduct permanent repairs to MSD tank as directed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2018
Resolved 22 May 2018
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 January 2018 Resolved
Repair as original aft outboard longitudinal below port MDE overboard in lazarette
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2018
Resolved 22 May 2018
Construction/Loadline › Hull › Bracket
Issued 9 January 2018 Resolved
Reinstall as original barcket that supports port MDE exhaust in aft lazarette
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 22 May 2018
Construction/Loadline › Hull › Bottom Plating
Issued 14 December 2017 Resolved
Conduct temp. reapirs to failed hull in aft passenger accomodation space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 22 December 2017
Resolution: Temp. reapirs to failed hull in aft passenger accomodation space completed
Construction/Loadline › Hull › Bottom Plating
Issued 14 December 2017 Resolved
Conduct temp. reapirs to failed hull in machinery space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 22 December 2017
Resolution: temp. reapirs to failed hull in machinery space completed
Construction/Loadline › Hull › Hull Plating
Issued 14 December 2017 Resolved
Conduct temp. reapirs to failed transom plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 9 January 2018
Resolution: Temp. reapirs to failed transom plating completed
Construction/Loadline › Hull › Hull Plating
Issued 14 December 2017 Resolved
Conduct temp. repiars incurred while departing dry dock to the shell plate iwo of the first intermediate inboard longitudinal frame from the chine at the #3 aft port transverse frame, located in the aft passenger sleeping accommodations space
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 December 2017
Resolved 9 January 2018
Resolution: Doubler installed
Construction/Loadline › Hull › Bottom Plating
Issued 8 December 2017 Resolved
Conduct UT's as directed in Focsle space
Action required: 705 - Other - as specified
Due 8 December 2017
Resolved 22 May 2018
Resolution: UT's conducted, O/O has results
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2017 Resolved
Conduct UT's as directed 6in. on center, Port side MDE, outboard, fwd. to aft blkhed. of machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 22 December 2017
Resolution: UT's conducted, O/O has copies
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2017 Resolved
Conduct UT's as directed 12in. on center, Port side MDE, outboard, fwd. to aft blkhed. of machinery space.
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 22 December 2017
Resolution: UT's conducted, O/O has copies
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2017 Resolved
Conduct UT's as directed 6in. on center, bottom plate of lazarette
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 22 December 2017
Resolution: UT's conducted, O/O has copies
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2017 Resolved
Conduct UT's as directed 6in. on center, bottom plate of lazarette
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 22 December 2017
Resolution: UT's conducted, O/O has copies
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 December 2017 Resolved
Make available for inspetion aft ballast tank
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 22 May 2018
Construction/Loadline › Hull › Stringer
Issued 7 December 2017 Resolved
Conduct permanent repairs to fractured transverse frame in bay 2, port side of fwd. accomodation space
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 22 May 2018
Construction/Loadline › Hull › Weld
Issued 7 December 2017 Resolved
Repair cracked weld, 01 deck, stbd. side
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 22 May 2018
Construction/Loadline › Hull › Weld
Issued 7 December 2017 Resolved
Conduct permanent repairs pax. rail, 01 deck, stbd. side
Due 7 December 2017
Resolved 22 May 2018
Engineering › Bilge Water Management System › Strainer
Issued 7 December 2017 Resolved
Conduct permanenet repairs to bilg pick up in aft passenger bunk room space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 22 December 2017
Resolution: Permanenet repairs conducted
Construction/Loadline › Hull › Side Shell
Issued 7 December 2017 Resolved
Conduct UT's as directed fwd. passenger space, thinned plate identified during close up
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 22 December 2017
Resolution: UT's conducted, O/O has copies
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 30 November 2017 Resolved
Install new Cutlass bearings Port/Starboard fore and aft
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 22 December 2017
Resolution: New cutlasses installed
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 30 November 2017 Resolved
Provide survey reports for Shafts, port shaft found worn by line entanglement, starboard shaft found with multiple horizontal fractures
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 22 December 2017
Resolution: Shafts serviced ashore and reinstalled
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 November 2017 Resolved
Properly light and make available for inspection all spaces
Condition: Improper/Lack of Maintenance
Due 30 November 2017
Resolved 22 May 2018
Construction/Loadline › Hull › Side Shell
Issued 30 November 2017 Resolved
Open and make available for inspection over board port exhaust for MDE at shell plate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 22 December 2017
Resolution: Made available for inspection e
Electrical › Lighting (service) › Lighting Fixture
Issued 27 November 2017 Resolved
Replace guards on all lighting fixtures in berthing areas.
Condition: Improper/Lack of Maintenance
Due 15 December 2017
Resolved 6 June 2018
Lifesaving › Lifefloat › Serviceable
Issued 21 November 2017 Resolved
Recondition or replace life floats
Condition: Improper/Lack of Maintenance
Due 15 February 2018
Resolved 6 June 2018
Resolution: All life-floats have been temp repaired with [name withheld] patch kit.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 November 2017 Resolved
relabel ring bouys
Condition: Improper/Lack of Maintenance
Due 27 November 2017
Resolved 27 November 2017
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Paddle
Issued 13 December 2016 Resolved
Label all paddles
Condition: Placed in Improper Service
Due 20 December 2016
Resolved 13 December 2016
Resolution: Corrected on the spot
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 December 2016 Resolved
Relabel ring buoys
Condition: Placed in Improper Service
Due 20 December 2016
Resolved 13 December 2016
Resolution: Corrected on the spot
Electrical › Lighting (service) › Lighting Fixture
Issued 13 December 2016 Resolved
install globes on light fixtures in berthing
Condition: Placed in Improper Service
Due 20 December 2016
Resolved 13 December 2016
Resolution: Corrected on the spot
Fire Fighting › Means of Escape › Handrails/Handholds
Issued 31 January 2011 Resolved
Prior to overnight passengers, repair or replace the wasted ladder railing to aft berthing.
Action required: 705 - Other - as specified
Due 2 March 2011
Resolved 2 March 2011
Resolution: MI attended vessel and cleared def
Construction/Loadline › Hull › Longitudinal Frame
Issued 28 January 2011 Resolved
Port aft E/R outboard of exhaust, crop and renew wasted main deck longitudinal.
Action required: 705 - Other - as specified
Due 2 March 2011
Resolved 2 March 2011
Resolution: MI attended vessel and cleared def
Construction/Loadline › Structures › Deck Plating
Issued 28 January 2011 Resolved
Properly insert wasted main deck under galley sink.
Action required: 705 - Other - as specified
Due 2 March 2011
Resolved 2 March 2011
Resolution: MI attended vessel and cleared def
Engineering › Bilge Water Management System › Pump
Issued 28 January 2011 Resolved
Repair bilge pump mounting bracket.
Action required: 705 - Other - as specified
Due 2 March 2011
Resolved 2 March 2011
Resolution: MI attended vessel and cleared def
Construction/Loadline › Structures › Superstructure
Issued 28 January 2011 Resolved
Replace window starboard side aft of door on pilot station
Action required: 705 - Other - as specified
Due 2 March 2011
Resolved 2 March 2011
Resolution: MI attended vessel and cleared def
Construction/Loadline › Structures › Superstructure
Issued 30 November 2010 Resolved
Replace cracked windows at port aft control station and #8 Stbd aft main deck at next dry dock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 4 January 2011
Communications › Radio Communications › EPIRB
Issued 30 November 2010 Resolved
Replace EPIRB Hydrostatic realese prior to carrying passengers.
Condition: Placed in Improper Service
Due 30 November 2010
Resolved 2 December 2010
Communications › Alarms/Indicators › Bilge Alarm
Issued 30 November 2010 Resolved
Repair lazarette high water alarm.
Condition: Placed in Improper Service
Due 30 November 2010
Resolved 30 November 2010
Resolution: Corrected on the spot.
Documentation › Markings/Placards › Warning Signs
Issued 30 November 2010 Resolved
Relable sign for maximum passengers allowed on upper deck.
Condition: Improper/Lack of Maintenance
Due 30 November 2010
Resolved 30 November 2010
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 17 December 2009 Resolved
Renew COD.
Action required: 705 - Other - as specified
Resolved 19 February 2010
Lifesaving › Lifefloat › Float Free
Issued 17 December 2009 Resolved
Organize lifefloat arrangement as discussed to prevent tangling.
Due 17 January 2010
Resolved 29 January 2010
Electrical › Lighting (emergency) › Lighting Fixture
Issued 17 December 2009 Resolved
Repair emergency lighting in berthing area prior to allowing passengers below deck or sailing overnight.
Due 17 January 2010
Resolved 29 January 2010
Resolution: Battery replaced.
Communications › Alarms/Indicators › Fire Alarm
Issued 17 December 2009 Resolved
Provide/install minimum two smoke U/L approved detectors in berthing prior to allowing passengers below deck or sailing overnight.
Due 17 January 2010
Resolved 29 January 2010
Resolution: Two smoke detectors installed in opposite ends of berthing.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 17 December 2009 Resolved
Permanently install freezers with breaker/cabling/junction box IAW 46 CFR Part 183, as discussed. They were found plugged into receptacle, with temporary drop cords, wired into berthing area lighting circuit.
Action required: 705 - Other - as specified
Due 17 January 2010
Resolved 29 January 2010
Resolution: Breaker/junction box installed.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 17 December 2009 Resolved
Provide maintenance and general housekeeping in engine room as discussed. Repair electrical connections, lighting, deck plating, clean up excessive dirt and oil, etc. MUCH PROGRESS must be made in this area for certificate to remain valid.
Action required: 705 - Other - as specified
Due 17 February 2010
Resolved 19 February 2010
Resolution: Good progress. Clutter removed. Engine room cleaner and safer.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 22 January 2009 Resolved
Provide 77 PFD Lights. Vessel not permitted to carry more than 43 PERSONS on a route beyond the limited CW NMT 20 miles from safe refuge.
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 2 February 2009
Resolution: Completed.
Construction/Loadline › Markings › Draft Marks/Indicating System
Issued 22 January 2009 Resolved
Paint draft marks on hull.
Condition: Unknown
Action required: 705 - Other - as specified
Due 15 April 2009
Resolved 2 February 2009
Resolution: Completed.
Documentation › Certificates/Documents › FCC SSL
Issued 22 January 2009 Resolved
Correct call sign on FCC safety radiotelephony cert.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 16 February 2009
Resolved 2 February 2009
Resolution: Completed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 22 January 2009 Resolved
Install PFD lights on 120 Adult PFDS and 12 Child PFDs. Insure these are most readily available and well marked for ocean route service.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 9 February 2009
Resolution: Reissued for all 156 PFDs
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 22 January 2009 Resolved
Clean medicine chest and replace all worn & outdated materials. (Present a clean and complete first-aid kit to the attending inspector upon return to vessel to clear requirements!)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 2 February 2009
Resolution: Completed.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 22 January 2009 Resolved
Mark vessel's NAME and PORT on all ringbuoys.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 2 February 2009
Resolution: Completed.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 22 January 2009 Resolved
Replace worn sun-rotted 60' line for ringbuoy.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 January 2009
Resolved 2 February 2009
Resolution: Completed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 22 January 2009 Resolved
Provide PFD lights for all 156 adult and all child PFDs aboard. Vessel is restricted to not more than 120 persons on routes beyond 20 miles from a harbor of safe refuge until this requirement is met.
Action required: 705 - Other - as specified
Due 10 July 2009
Resolved 10 July 2009
Resolution: Lights added.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 22 January 2009 Resolved
Provide 144 adult PFD type I for a total of 300 adult and 30 child aboard vessel. Vessel restricted to Not More Than 150 passengers 156 total persons until this requirement is satisfied
Action required: 705 - Other - as specified
Due 31 July 2009
Resolved 30 September 2009
Resolution: See ltr P182-09.
Stability › Weathertight Integrity › General
Issued 6 January 2009 Resolved
Replace the 3 cracked windows in the pilot house, the one port side fwd most window and the two front windows to the port side, as discussed with the Coast Guard Inspector.
Condition: Unknown
Action required: 705 - Other - as specified
Due 30 January 2009
Resolved 30 January 2009
Resolution: Received photographs via email showing the windows had been replaced.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 6 January 2009 Resolved
Provide valid COI onboard prior to carrying passengers.
Action required: 705 - Other - as specified
Due 20 February 2009
Resolved 22 January 2009
Electrical › Lighting (service) › Lighting Fixture
Issued 26 November 2007 Resolved
Install diffuser on deck light fwd port side of the passenger accommodations.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 23 January 2008
Resolution: Installed plexi-glass light cover on deck light port side main deck forward of passenger accomodation space.
Electrical › Electric Generation Source (service) › Generator
Issued 26 November 2007 Resolved
Remount gauge panel for diesel prime movers on Port & Stbd SS GenSets.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 23 January 2008
Resolution: Missing Gauge panels were remounted for diesel prime movers on Port and Stbd SS Generators.
Electrical › Electrical Distribution System (service) › Conductor
Issued 26 November 2007 Resolved
Secure electrical cables with permanent mounting clamps to aft bhd of aft berthing space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 23 January 2008
Resolution: Secure loose electrical cables with permanent mounting clamps to aft bulkhead in aft berthing area.
Accommodation/Occupational Safety › Heating › Metal Protection
Issued 26 November 2007 Resolved
Repair protective casing for oil fired hot air heater.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 23 January 2008
Resolution: Repaired protective casing for oil fired hot air heater by replacing missing screw to secure it.
Electrical › Electrical Distribution System (service) › Switchboard
Issued 26 November 2007 Resolved
Provide a dielectric mat for the deck in front of the main switchboard.
Action required: 705 - Other - as specified
Due 1 December 2007
Resolved 23 January 2008
Resolution: Provided new approved dielectric mat for the deck in front of the main switchboard.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 26 November 2007 Resolved
On Oceans routes the vessel is limited to not more than 121 total persons of which not more than 24 may be children or persons weighing less than 90# until the full compliment of required life jackets with lights is properly aboard the vessel.
Action required: 705 - Other - as specified
Due 22 January 2009
Resolved 22 January 2009
Resolution: Cancelled & reissued w/ 1.22.09 Annual exam.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 26 November 2007 Resolved
On Limited Coastwise routes the vessel is limited to not more than 179 total persons of which not more than 38 maybe children or persons weighing less than 90# until the full compliment of required life jackets is properly aboard the vessel.
Action required: 705 - Other - as specified
Resolved 22 January 2009
Resolution: Closed & reissued at 1.22.09 annual exam
Electrical › Electrical Distribution System (service) › Wiring
Issued 30 October 2006 Resolved
Remove dead end wires in engine room in the way of the fire pump.
Due 7 November 2006
Resolved 30 October 2006
Engineering › Generator (propulsion-electric) › Heating Element Circuitry
Issued 30 October 2006 Resolved
Provide Air Intake protective screen for SS Generator.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 November 2006
Resolved 1 November 2006
Resolution: Sent confirmation that they had provided SS Generators air intakes with protective screens.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 October 2006 Resolved
Replace worn ladder rungs leading to engine room.
Condition: Improper/Lack of Maintenance
Due 30 November 2006
Resolved 29 November 2006
Resolution: Replaced worn ladder rungs leading to the engine room with new ones.
Engineering › Generator (propulsion-electric) › Wiring
Issued 30 October 2006 Resolved
Secure gauge panels on SSGEN's back into place.
Due 7 November 2006
Resolved 7 November 2006
Resolution: Secured guage panels on SSGEN''s back into place.
Engineering › Steering Gear System › Fastener
Issued 30 October 2006 Resolved
Replace four bolts on STBD side steering cylinders foundation in laz. space that are too short.
Due 7 November 2006
Resolved 11 November 2006
Resolution: Replaced four bolts on STBD side steering cylinders foundation in laz. space that are too short.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 30 October 2006 Resolved
Repair lifejacket storage box to prevent water from getting in.
Due 30 November 2006
Resolved 29 November 2006
Resolution: Repaired lifejacket storage box to prevent water from getting in.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 October 2006 Resolved
Permanantly repair cracked frame in forward berthing compartment.
Action required: 705 - Other - as specified
Resolved 25 January 2007
Resolution: Examined repair weld of cracked frame. All sat.
Lifesaving › Lifefloat › Painter
Issued 30 October 2006 Resolved
Re-arrange lifefloat set-up to the direction of NVIC 1-83
Due 1 November 2006
Resolved 1 November 2006
Resolution: Received faxed documentation stating completion of re-arrangement of lifefloats.
Lifesaving › Lifefloat › Platform
Issued 30 October 2006 Resolved
Patch and repair worn areas on lifefloats.
Due 7 November 2006
Resolved 7 November 2006
Resolution: Properly repaired worn areas on lifeboats.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 30 October 2006 Resolved
Replace worn stantions on main deck passenger space. (from the bow # 4+5 on port side and #5 on starboard side).
Due 30 November 2006
Resolved 19 December 2006
Resolution: Examined repair welds of stantions on main deck passenger space. All sat.
Accommodation/Occupational Safety › Other Accommodation Spaces › Open Deck Space
Issued 30 October 2006 Resolved
Replace two cracked windows on port side main deck.
Due 30 November 2006
Resolved 29 November 2006
Resolution: Replaced two cracked windows on port side main deck with new ones.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 13 October 2005 Resolved
Vessel is missing 149 adult life jackets. Vessel is restricted to 151 total persons on a LCW (or shorter) route. Vessel is in compliance for 120 pax on oceans route. Restriction is in effect until owner proves vessel has added 149 life jackets. Owner wants this to remain in effect until life jackets provided.
Due 1 November 2005
Resolved 5 August 2008
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 13 October 2005 Resolved
Relabel life jacket storage boxes to reflect how many and if lighted. Child and adult should be separated and labeled separately.
Due 1 November 2005
Resolved 27 October 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 13 October 2005 Resolved
Provide cages for all lighting fixtures below deck.
Due 1 November 2005
Resolved 1 November 2005
Lifesaving › Lifefloat › Markings
Issued 13 October 2005 Resolved
Relabel life float with vessel name and max persons. (the top one on the port side)
Due 1 November 2005
Resolved 27 October 2005
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 5 November 2004 Resolved
Provide 50% of crew with Redcross CPR/First-aid training.
Condition: Improper/Lack of Maintenance
Due 3 December 2004
Resolved 23 December 2004
Operations/Management › Drills/Instruction › Fire
Issued 5 November 2004 Resolved
Update emergency instructions to fit vessel lay-out.
Condition: Improper/Lack of Maintenance
Due 3 December 2004
Resolved 5 November 2004
Lifesaving › Lifejacket/PFD (General) › Quantity
Issued 21 October 2004 Resolved
Provide 28 lifejackets, limited to 272 passengers until corrected.
Due 5 November 2004
Resolved 3 November 2004
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 21 October 2004 Resolved
Provide 57 lifejacket lights, limited to 63 passengers oceans.
Due 5 November 2004
Resolved 3 November 2004
Electrical › Lighting (service) › Lighting Fixture
Issued 21 October 2004 Resolved
Provide covers for engine room lights. Need portective globes on all lights below main deck.
Due 5 November 2004
Resolved 3 November 2004
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 21 October 2004 Resolved
Provide eye wash for first aid kit.
Due 5 November 2004
Resolved 3 November 2004
Navigation › Piloting/Steering › Tide/Tidal Current Tables
Issued 21 October 2004 Resolved
Provide tide and curretn tables.
Due 5 November 2004
Resolved 3 November 2004
Pollution Prevention/Response › Prevention Equipment › Sewage System Valve
Issued 21 October 2004 Resolved
Lock MSD overboard discharge valve in the closed position.
Due 5 November 2004
Resolved 3 November 2004
Operations/Management › Drills/Instruction
Issued 24 November 2003 Resolved
Provide proof that fire and man overboard drills are logged and conducted monthly per 46 CFR 122.520 and 122.524. LEGACY COMPONENT DESC: Fire
Condition: Unknown
Due 1 December 2003
Resolved 1 December 2003
Resolution: Drills conducted and logged.
Operations/Management › Equipment Service/Testing
Issued 24 November 2003 Resolved
Log/conduct monthly EPIRB tests. LEGACY COMPONENT DESC: EPIRB
Condition: Unknown
Due 1 December 2003
Resolved 1 December 2003
Resolution: EPIRB check conducted and logged.
Lifesaving › Lifebuoys
Issued 24 November 2003 Resolved
Amidships port and starboard life rings must have SOLAS approved retro-tape.
Condition: Unknown
Due 1 December 2003
Resolved 1 December 2003
Lifesaving › Lifebuoys
Issued 24 November 2003 Resolved
Approved repairs or replacement of both port life rings needed.
Condition: Unknown
Due 1 December 2003
Resolved 6 January 2004
Lifesaving › Buoyant Apparatus
Issued 24 November 2003 Resolved
Repair with approved repair material all 10 lifefloats. LEGACY COMPONENT DESC: Lifefloats
Condition: Unknown
Due 1 December 2003
Resolved 6 January 2004
Lifesaving › Buoyant Apparatus
Issued 24 November 2003 Resolved
Lifefloats must be separated as to not stick to one another. LEGACY COMPONENT DESC: Lifefloats
Due 1 December 2003
Resolved 1 December 2003
Lifesaving › Buoyant Apparatus
Issued 24 November 2003 Resolved
Remove all plastic zipties from lifefloats and paddles with a material easy to remove. LEGACY COMPONENT DESC: Lifefloats
Due 1 December 2003
Resolved 1 December 2003
Electrical › Lighting (service)
Issued 24 November 2003 Resolved
Repair light switch at foot of aft berthing compartment. LEGACY COMPONENT DESC: Switch
Due 1 December 2003
Resolved 1 December 2003
Engineering
Issued 24 November 2003 Resolved
Remove heat pumps in aft berthing compartment. LEGACY COMPONENT DESC: Heat pumps
Due 1 December 2003
Resolved 1 December 2003
Documentation › Certificates/Documents
Issued 24 November 2003 Resolved
Post stability letter. LEGACY COMPONENT DESC: Stability Letter
Condition: Unknown
Due 1 December 2003
Resolved 1 December 2003
Documentation › Certificates/Documents
Issued 24 November 2003 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 31 December 2003
Resolved 6 January 2004
Operations/Management › Passenger Operations
Issued 24 November 2003 Resolved
Ensure voyage plan provided for overnight trips. LEGACY COMPONENT DESC: Voyage Plan
Condition: Unknown
Due 1 December 2003
Resolved 1 December 2003
Resolution: Voyage plan submitted, standard form made for fleet.
Accommodation/Occupational Safety › Other Accommodation Spaces
Issued 24 November 2003 Resolved
Replace two port side crew cabin windows. LEGACY COMPONENT DESC: Window
Condition: Unknown
Due 31 December 2003
Resolved 6 January 2004
Construction/Loadline › Markings
Issued 24 November 2003 Resolved
Mark upper deck passenger limit. LEGACY COMPONENT DESC: Upper Deck Passenger Limit
Condition: Unknown
Due 1 December 2003
Resolved 1 December 2003
Lifesaving › Lifejacket/PFD (General)
Issued 24 November 2003 Resolved
Ensure required lifejackets have proper name stenciled. LEGACY COMPONENT DESC: Marking
Due 1 December 2003
Resolved 1 December 2003
Construction/Loadline › Hull › Hull Plating
Issued 2 June 2003 Resolved
PROVIDE RESULTS TO COGNIZANT OCMI OF THE FOLLOWING: PROVIDE AVAILABLE EXISTING INFORMATION NOTED ON VESSEL'S COI AND CURRENT HIGH TENSILE STEEL REPAIR PROCEDURES BEING USED TO CG MSC REQUESTING EVALUATION OF HULL & UPDATED HIGH TENSILE STEEL REPAIR PROCEDURES TO UPDATE STATEMENT ON VESSEL'S COI. LEGACY COMPONENT DESC: Bottom Plating
Action required: 705 - Other - as specified
Resolved 17 October 2005
Resolution: Over 2 years old, no proof in cases of clearing def. Cleared vsl in service with 2 year in service with no problems on plating replaced.
Stability › Watertight Integrity
Issued 12 May 2003 Resolved
Prior to the completion of a Credit Dry Dock Examination and the carriage of passengers, provide specifications for proper repair to vessel hull per statement on COI. LEGACY COMPONENT DESC: Insert
Condition: Placed in Improper Service
Due 30 May 2003
Resolved 2 June 2003
Resolution: Issue re-addressed and discussed with ACID PROMS of possibility of having owner resubmit info to MSC for guidance on changing COI high strength tensile steel to utilizing CORE-TEN steel and those weld procedures for future hull repair as already proven.
Stability › Watertight Integrity
Issued 12 May 2003 Resolved
Prior to the completion of a Credit Dry Dock Examination and the carriage of passengers, provide details of specifics for high tensile steel repair from noted plans. LEGACY COMPONENT DESC: Inserts
Condition: Placed in Improper Service
Due 30 May 2003
Resolved 2 June 2003
Resolution: Rcv''''d 2 letters from [name withheld] detailing specifics for COR-TEN high tensile steel used for the hull repairs. Plans noted on the COI are no longer available. Research and steel mfg statement indicates repair proper.
Stability › Watertight Integrity
Issued 12 May 2003 Resolved
Prior to the completion of a Credit Dry Dock Examination and the carriage of passengers, provide current and replacement plate specs, weld proceedures, welders experience and proceedure used. LEGACY COMPONENT DESC: Inserts
Condition: Placed in Improper Service
Due 30 May 2003
Resolved 2 June 2003
Resolution: Rcv''''''''d 2 letters from [name withheld] detailing specifics for COR-TEN high tensile steel used for the hull repairs. Current hull plating from plans noted on the COI is no longer available. Rcv''''d welder info and procedure used.
Stability › Watertight Integrity
Issued 12 May 2003 Resolved
Prior to the completion of a Credit Dry Dock Examination and the carriage of passengers, demonstrate by NDT (i.e. Dye Penetrant, UT Shearwave) for all hull plates inserted in Tampa Zone, April-May 2003, meet specifications of attending CG marine inspector. LEGACY COMPONENT DESC: Inserts
Condition: Placed in Improper Service
Due 30 May 2003
Resolved 27 May 2003
Resolution: Witnessed dye penetrant testing of all repairs in presence of CG Marine Inspector.
Electrical › Electrical Distribution System (service)
Issued 26 November 2002 Resolved
Replace broken electrical receptical (4 gang) on aft bulkhead outside of wheelhouse -- use UL -- wet location equipment.
Due 15 December 2002
Resolved 11 September 2003
Resolution: New one installed.
Communications › Radio Communications
Issued 26 November 2002 Resolved
Make emergency broadcast placard vessel specific. LEGACY COMPONENT DESC: VFH Radiotelephone
Due 15 December 2002
Resolved 11 September 2003
Resolution: Vessel name filled in, and characteristics added.
Lifesaving › Lifebuoys
Issued 26 November 2002 Resolved
Restencil name on stbdside ringbuoy. LEGACY COMPONENT DESC: Markings (ship name/port)
Due 15 December 2002
Resolved 11 September 2003
Resolution: Re-stenciled in black.
Electrical › Electrical Distribution System (service)
Issued 26 November 2002 Resolved
Remove numerous dead ended wires under bridge console. Cap and label spares. LEGACY COMPONENT DESC: Wiring
Due 15 December 2002
Resolved 4 September 2003
Resolution: Completed.
Accommodation/Occupational Safety › Occupational Safety
Issued 26 November 2002 Resolved
Replace broken pilothouse window.
Due 15 December 2002
Resolved 11 September 2003
Resolution: Completed in drydock.
Electrical › Electrical Distribution System (emergency)
Issued 26 November 2002 Resolved
Repair wiring for emergency batteries in pilothouse. LEGACY COMPONENT DESC: Wiring
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2002
Resolved 11 September 2003
Resolution: Completed.
Electrical › Electric Supply System (service)
Issued 26 November 2002 Resolved
Provide a box for the port battery in the pilothouse. LEGACY COMPONENT DESC: Battery Installation
Condition: Improper Installation
Due 15 December 2002
Resolved 11 September 2003
Resolution: Plastic box provided.
Accommodation/Occupational Safety › Occupational Safety
Issued 26 November 2002 Resolved
Replace broken windows in accomodation spaces.
Due 15 December 2002
Resolved 4 September 2003
Resolution: Windows replaced at drydock.
Accommodation/Occupational Safety › Heating
Issued 26 November 2002 Resolved
Install a 15 second purge cycle for the oil burner. (Air pumps must operate prior to ignition). LEGACY COMPONENT DESC: Burners
Due 15 December 2002
Resolved 11 September 2003
Resolution: Faxed that it has been corrected.
Electrical › Lighting (service)
Issued 26 November 2002 Resolved
Correct improper splices for 120 VAC deck lighting, upper deck lighting wiring near rails. (use splice boxes for the connections).
Condition: Improper Installation
Due 15 December 2002
Resolved 11 September 2003
Resolution: Renewed.
Fire Fighting › Fire Hoses
Issued 26 November 2002 Resolved
Provide fire hoses and nozzles.
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 December 2002
Resolved 11 September 2003
Resolution: Provided.
Accommodation/Occupational Safety › Medical/First Aid
Issued 26 November 2002 Resolved
Renew aspirin/eyewash for first aid kit. LEGACY COMPONENT DESC: Medicine Chest
Due 15 December 2002
Resolved 11 September 2003
Resolution: Renewed.
Construction/Loadline › Structures
Issued 26 November 2002 Resolved
Repair leaking deck drain in engine room. LEGACY COMPONENT DESC: Deck Plating
Due 15 December 2002
Resolved 11 September 2003
Resolution: Repaired in drydock
Construction/Loadline › Hull
Issued 20 November 2002 Resolved
No passenger are permitted onboard until item TR2 of this activity is completed sat.
Due 31 March 2003
Resolved 27 May 2003
Resolution: Cleared this reqmnt in conjunction with reqmnt TR2 issued 11/20/03 by PROMS - work to lazerette and main deck completed and permitted to carry passengers as per this noted repair.
Construction/Loadline › Hull
Issued 20 November 2002 Resolved
Sand blast entire laz to varify good metal and affect permenant repairs IWO temp repairs made during Nov of 2002 to main deck.
Due 31 March 2003
Resolved 27 May 2003
Documentation › Certificates/Documents
Issued 7 February 2002 Resolved
Post curent COI and stability letter. LEGACY COMPONENT DESC: Certificate of Inspection
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 1 March 2002
Resolution: Posted. Confirmed via ltr dated 1 Mar 02.
Personnel › Certificates/Documents/Licenses
Issued 7 February 2002 Resolved
Port current licenses & FCC radio operator permits. Provide proof of current licenses. LEGACY COMPONENT DESC: License, Master
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 1 March 2002
Resolution: Vessel owener verified items were done in letter dated 1 Mar 02.
Documentation
Issued 7 February 2002 Resolved
Post SPV decal.
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 1 March 2002
Resolution: Sticker posted. Confirmed by vessel owner 1 Mar 02.
Navigation › Piloting/Steering
Issued 7 February 2002 Resolved
Provide corrected charts, US Coast Pilot, CG Light list, tide tables & tidal current tables IAW 46 CFR 184.420. LEGACY COMPONENT DESC: Marine Charts
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 1 March 2002
Resolution: Items purchased. Verified by vessel owner in letter dated 1 Mar 02.
Lifesaving
Issued 7 February 2002 Resolved
Renew EPIRB Battery. Vessel restricted to no farther than 3 nm from shore until corrected.
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 1 March 2002
Resolution: New battery purchased. Owner verified in letter dated 1 Mar 02.
Lifesaving
Issued 7 February 2002 Resolved
Properly install EPIRB. Vessel restricted to no more than 3 nm from shore until completed.
Condition: Improper Installation
Due 21 February 2002
Resolved 1 March 2002
Resolution: Appropriate bracket purchased and EPIRB installed.
Lifesaving
Issued 7 February 2002 Resolved
Register EPIRB. Vessel restricted to no farther than 3 nm from shore until corrected.
Condition: Improper Installation
Due 21 February 2002
Resolved 7 February 2002
Resolution: EPIRB registered with NOAA. Copy of registration sticker faxed to unit.
Lifesaving › Buoyant Apparatus
Issued 7 February 2002 Resolved
Provide 2 paddles for lifefloats. Maximum passenger capacity reduced by 10 adults until corrected.
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 1 March 2002
Resolution: Two paddles purchased. Verfied by owner in letter dated 1 Mar 02.
Lifesaving › Lifejacket/PFD (Type I)
Issued 7 February 2002 Resolved
Separate and mark location of child lifejackets. LEGACY COMPONENT DESC: Storage
Condition: Improper Installation
Due 21 February 2002
Resolved 1 March 2002
Resolution: Completed and verified in letter from owner dated 1 Mar 02.
Lifesaving › Lifebuoys
Issued 7 February 2002 Resolved
Provide floatable lifeline for stbd ringbuoy IAW 46 CFR 180.70. LEGACY COMPONENT DESC: Buoyant Lifeline
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 1 March 2002
Resolution: New lifeline attached. Verified by 1 Mar 02 letter from vessel owner.
Lifesaving › Lifebuoys
Issued 7 February 2002 Resolved
Restencil vessel name on port and starboard ringbuoys. LEGACY COMPONENT DESC: Markings (ship name/port)
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 1 March 2002
Resolution: Re-stenciled. Verified via letter dated 1 Mar 02 from vessel owner.
Documentation › Markings/Placards
Issued 7 February 2002 Resolved
Mark upperdeck passenger limit IAW stability letter. LEGACY COMPONENT DESC: Capacity Marking
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 1 March 2002
Resolution: Plaque attached to ladderway. Verified by vessel owner in letter dated 1 Mar 02.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 7 February 2002 Resolved
Install bracket for bridge fire extinguisher. LEGACY COMPONENT DESC: Mounting Bracket
Condition: Unknown
Due 15 February 2002
Resolved 8 February 2002
Resolution: Bracket installed. Verified by owner in letter dated 8 Feb 02.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 7 February 2002 Resolved
Provide tamper resitient seals for 3 BII fire extinguishers.
Condition: Improper/Lack of Maintenance
Due 15 February 2002
Resolved 1 March 2002
Resolution: Seals were replaced. Verified by vessel owner in letter dated 1 Mar 02.
Fire Fighting › Portable CO2 Fire Extinguisher
Issued 7 February 2002 Resolved
Service portable fire extinguishers. LEGACY COMPONENT DESC: Service
Condition: Improper/Lack of Maintenance
Due 15 February 2002
Resolved 1 March 2002
Resolution: All extinguishers serviced. Verified by letter dated 1 Mar 02 from vessel owner.
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 February 2002 Resolved
Remove extension cords from under bridge console.
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2002
Electrical › Electrical Distribution System (service) › Wiring
Issued 7 February 2002 Resolved
Enclose wirenuts on bridge or change type of connection.
Condition: Improper Installation
Due 21 February 2002
Resolved 8 February 2002
Fire Fighting › Fire Pumps
Issued 7 February 2002 Resolved
Provide pressure gauge for fire pump. LEGACY COMPONENT DESC: Pressure
Due 21 February 2002
Resolved 1 March 2002
Resolution: Guage installed. Verified via letter dated 1 Mar 02 from vessel owner.
Lifesaving › Buoyant Apparatus
Issued 7 February 2002 Resolved
Repair cracked lifefloat, top forward one is cracked.
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 1 March 2002
Resolution: Crack was repaired with epoxy. Verified by owner by letter dated 1 Mar 02.
Electrical › Electrical Distribution System (service)
Issued 7 February 2002 Resolved
Hardwire or install receptacle for stbd freezer in accomodation space. Remove extension cord. LEGACY COMPONENT DESC: Wiring
Condition: Improper Installation
Due 21 February 2002
Resolved 1 March 2002
Resolution: Extension chord removed. Verified via letter dated 1 Mar 02 from vessel''s master.
Electrical › Lighting (emergency)
Issued 7 February 2002 Resolved
Repair/renew emergency light in forward accomodation space. Vessel may not carry passengers in this compartment until complete. LEGACY COMPONENT DESC: Battery Operated Lantern
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 8 February 2002
Resolution: Verified complete by vessel owner by letter dated 8 Feb 02.
Fire Fighting › Fire Hoses › Connections
Issued 7 February 2002 Resolved
Provide nozzle for firehose.
Condition: Improper/Lack of Maintenance
Due 21 February 2002
Resolved 8 February 2002
Unknown
Issued 9 February 2001 Resolved
REPLACE ALL MAIN DECK WEATHERTIGHT DOOR'S GASKETS.
Condition: Unknown
Due 9 February 2001
Resolved 9 February 2001
Lifesaving
Issued 17 November 1999 Resolved
PROVIDE 12 PFD WATERLIGHTS FOR CHILDRENS PFDs. NO CHILDREN PERMITED ON OCEANS ROUTE UNTIL CLEARED.
Condition: Unknown
Due 30 November 1999
Resolved 6 December 1999
Lifesaving
Issued 17 November 1999 Resolved
PROVIDE SIX ADULT PFDs. MAXIMUM PASSENGER AND CREW LIMITED TO 294 ON LIMITED COASTWISE ROUTE.
Condition: Unknown
Due 30 November 1999
Resolved 6 December 1999
Lifesaving
Issued 10 February 1999 Resolved
REPAIR CRACKED WINDOWS.
Condition: Unknown
Due 22 February 1999
Resolved 22 February 1999
Construction/Loadline
Issued 10 February 1999 Resolved
MAKE PERMANENT REPAIR IWO TEMPORARY REPAIR TO WASTED SECTION OF AFT BHD OF MACHINERY SPACE, STBD SIDE APROX 1 1/2' FROM BOTTOM.
Condition: Unknown
Due 10 February 1999
Resolved 10 February 1999
Unknown
Issued 3 February 1999 Resolved
REPLACE 2 MISSING DOGS ON LAZARETTE DECK HATCH.
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Unknown
Issued 3 February 1999 Resolved
PROVIDE PLANS DETAILING ALTERATIONS TO MSD SYSTEM AND FIRE DAMPER ASSEMBLIES.
Condition: Unknown
Due 3 February 1999
Resolved 3 February 1999
Lifesaving
Issued 26 April 1998 Resolved
POST EMERGENCY BROADCAST PLACARD NEXT TO R/T EQUIPMENT.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
CLEAN PETROLEUM PRODUCT OUT OF BILGE IN LAZ. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
REMOVE THE 15 5 GALLON CONTAINERS OF OIL/HYD FLUID STORED IN E/R BILGES. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
SECURE WATER HEATER, STBD SIDE, E/R.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Electrical
Issued 26 April 1998 Resolved
SECURE BREAKER PANEL COVER, E/R, STBD SIDE IWO AFT E/R ENTRANCE.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
SECURE COFFEE POT IN GALLEY.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
SECURE SMALL REFRIGERATOR IN GALLEY.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Electrical
Issued 26 April 1998 Resolved
REMOVE EXTENSION CORD SERVING SMALL REFRIGERATOR IN GALLEY.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Construction/Loadline
Issued 26 April 1998 Resolved
CROP AND RENEW WASTED VERTICAL STRENGTH MEMBERS, STBD SIDE LAZ BEHIND TANK.
Condition: Unknown
Due 26 April 1998
Resolved 26 April 1998
Lifesaving
Issued 26 April 1998 Resolved
RENEW/PLUG PERFORATED ELBOW ON VENT PIPE SERVING OIL FIRED FURNACE, MAIN DECK PASSENGER CABIN.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Electrical
Issued 26 April 1998 Resolved
PROPERLY WIRE SPOTLIGHT FASTENED TO STERNLIGHT MAST. REMOVE EXTENSION CORDW/FEMALE END CUT OFF AND SPLICED IN USED NOW. IT EXTENDS DOWN 2 DECKS (VIAA LADDER WELL AND A VENT SHAFT) TO E/R WHERE IT PLUGS INTO AN OUTLET SOMEWHERE IN E/R.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
PROPERLY INSTALL COVER ON OIL FIRED FURNACE. INSPECTOR FOUND GLOVES, CANDYBAR, LURES, DEBRIS INSIDE OF COVER AND FILTER AREA.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Electrical
Issued 26 April 1998 Resolved
REMOVE DEADENDED WIRING IN STORAGE SPACE, STBD SIDE, MAIN DECK PASSENGER CABIN, IWO STBD ENTRANCE.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Fire Fighting
Issued 26 April 1998 Resolved
PROVIDE 2 B-II EXTINGUISHERS. FOUND 2 DISCHARGED. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Electrical
Issued 26 April 1998 Resolved
RENEW LIGHT SWITCH SERVING LIGHTS IN FWD PASSENGER COMPT.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
REMOVE EXTENSION CORD SERVING SMALL REFRIDGERATOR IN FWD PASSENGER COMPT.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
REMOVE/PERMANENTLY SECURE REFRIDGERATOR AND SMALL FREEZER IN FWD PASSENGER COMPT.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
REMOVE PROPANE TANK, 5 GALLON OIL CONTAINERS, AND PAINT FROM FWD PASSENGER COMPT. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Electrical
Issued 26 April 1998 Resolved
LABEL ALL BREAKERS/SWITCHES IN E/R.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
INSTALL GUARD OVER PULLEY, PORT GEN SET.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Construction/Loadline
Issued 26 April 1998 Resolved
CLEAN OIL FROM BILGES IN E/R. NO PASSENGERS FOR HIRE UNTIL CLEARED.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Engineering
Issued 26 April 1998 Resolved
RENEW/REMOUNT LAGGING OVER EXHAUST SYS IN LAZ.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Construction/Loadline
Issued 26 April 1998 Resolved
PERMANENTLY REPAIR (STOP DRILL AND WELD) CRACK IN BULKHEAD, STBD SIDE FOC'SLE WHERE BULKHEAD MEETS MAIN DECK.
Condition: Unknown
Due 26 April 1998
Resolved 26 April 1998
Lifesaving
Issued 26 April 1998 Resolved
RENEW PRESSURE GAGE ON AIR TANK, STBD SIDE, E/R.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
PROPERLY ROUTE SIGHT TUBE ON TANK, PORTSIDE, IWO THE 3 PUMPS OUTBOARD OF PORT GEN SET.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Electrical
Issued 26 April 1998 Resolved
REMOVE WIRENUTS FROM WIRING ON PORT MDE AND THROUGHOUT VESSEL.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Electrical
Issued 26 April 1998 Resolved
INSTALL GLOBES AND METAL GUARDS ON ALL INCANDESENT LIGHTS THROUGHOUT VESSEL.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Electrical
Issued 26 April 1998 Resolved
REMOVE DEAD ENDED WIRING IN E/R.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
REMOVE DROP LIGHTS FROM VESSEL.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Engineering
Issued 26 April 1998 Resolved
MAKE PERMANENT MOUNTING BRACKETS FOR AIR FILTERS ON BOTH MDE'S. STRING NOWIN USE IS INSUFFICIENT.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Unknown
Issued 26 April 1998 Resolved
RENEW/PROVIDE AND INSTALL NEW HANDLES ON ALL VALVES IN E/R. NUMEROUS MISSING/BROKEN.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Lifesaving
Issued 26 April 1998 Resolved
REMOVE TEMPORARY COOLING FAN WHICH IS TIED TO OVERHEAD AND PLUGGED INTO LIGHT FIXTURE, E/R FWD.
Condition: Unknown
Due 1 May 1998
Resolved 6 July 1998
Fire Fighting
Issued 10 December 1997 Resolved
PROVIDE A PROPER BRACKET FOR THE SECOND FIRE EXTINGUISHER IN THE MACHINERY SPACE.
Condition: Unknown
Due 12 December 1997
Resolved 16 December 1997
Accommodation/Occupational Safety
Issued 10 December 1997 Resolved
REPAIR BROKEN WINDOWS IN DECKHOUSE.
Condition: Unknown
Due 31 December 1997
Resolved 5 January 1998
Accommodation/Occupational Safety
Issued 10 December 1997 Resolved
RESECURE LADDER TO MACHINERY SPACE.
Condition: Unknown
Due 12 December 1997
Resolved 5 January 1998
Lifesaving
Issued 10 December 1997 Resolved
PROVIDE SATISFACTORY PFD LIGHTS FOR AT LEAST 120 ADULT & 12 CHILD SIZE PFDSIAW OCMI,NY LTR DTD 01SEP89. TOTAL PERSONS ON OCEANS ROUTE LIMITED TO NMT60 ADULTS & 6 CHILDREN.
Condition: Unknown
Due 10 December 1997
Resolved 10 December 1997
Lifesaving
Issued 27 November 1996 Resolved
VESSELS TOTAL POB REDUCED TO A MAXIMUM OF 30 UNTIL REQ #17 IS CLEARED.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 27 November 1996 Resolved
PROVIDE AND INSTALL A 406 EPIRB PRIOR TO DEPARTING ON ANY OCEANS ROUTE.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 27 November 1996 Resolved
7 OF THE 10 L/Fs NEED REPAIR. THE OUTER COVERING OF 7 NEED REPAIR. RENEW LINE SECURING WEBBING/NETTING ON THE 6 OF THEM THAT NEED RENEWING.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 27 November 1996 Resolved
RENEW/REPAIR THE ONE FLOATING WATER LIGHT THAT IS INOP.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
RENEW MISSING ELECTRICAL CONNECTION BOX COVER OVER PORT MDE.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
REMOVE EXTENSION CORDS ON COFFEE POT AND REFRIDGERATOR IN GALLEY.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
LABEL ALL BREAKERS IN BOX IN WHEEL HOUSE BELOW 2 MAIN BREAKER BOXES.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 27 November 1996 Resolved
REPAIR OR REPLACE 88 ADULT PFD'S. CARRIAGE OF TOTAL PERSONS RESTRICTED TO 212.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 27 November 1996 Resolved
SECURE COOLER ON UPPER DECK.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Navigation
Issued 27 November 1996 Resolved
PROVIDE AND INSTALL UL1104 APPROVED RUNNING LIGHTS ON VSL.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 27 November 1996 Resolved
PROVIDE AND INSTALL LIFEJACKET PLACARD FOR ALL TYPES OF PFD'S ABOARD.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
REMOVE DEADENDED WIRING IN E/R. (P/S, FWD)
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
SECURE LOOSE LIGHT FIXTURE IN E/R. (P/S, FWD)
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
LABEL ALL CKT BREAKERS IN ALL BREAKER BOXES IN E/R.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
REMOVE DEADENDED WIRING FM OLD RADAR ON TOP OF WHEEL HOUSE.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
BLANK OFF HOLES IN 24 VOLT BREAKER BOX, P/S, FWD, E/R.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Construction/Loadline
Issued 27 November 1996 Resolved
RENEW TANK TOP ON TANK BTW GENERATORS IN E/R.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
PROPERLY SECURE HANDLE ON LIGHT SWITCH ON FWD BLKHD IN AFT BUNK ROOM.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 27 November 1996 Resolved
HARDWIRE EMERGENCY LIGHTING FIXTURE IN FWD BUNKROOM.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 27 November 1996 Resolved
SECURE FREEZER, REFRIDGERATOR, COFFEE POT, AND MICROWAVE OVEN IN GALLEY.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Lifesaving
Issued 27 November 1996 Resolved
PROVIDE AND INSTALL EMERGENCY BROADCAST PLACARD.
Condition: Unknown
Due 27 November 1996
Resolved 27 November 1996
Electrical
Issued 6 March 1996 Resolved
PROVE PROPER OPERATION OF EMERGECY LIGHTING IN FWD AND AFT BERTHING SPACES.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Accommodation/Occupational Safety
Issued 6 March 1996 Resolved
PROPERLY SECURE FREEZER IN FWD BERTHING.
Condition: Unknown
Due 6 March 1996
Resolved 8 March 1996
Fire Fighting
Issued 6 March 1996 Resolved
PROCURE AND INSTALL VALVE HANDLES WHERE MISSING FROM BILGE FIRE SYSTEM.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Electrical
Issued 6 March 1996 Resolved
CLEAN BATTERY TERMINALS ON MAIN ENGINE START BATTERIES (BANK OF 4).
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Documentation
Issued 6 March 1996 Resolved
SHOW PROOF OF COMPLIANCE WITH THE CHEMICAL TESTING REQUIREMENTS OF 46 C.F.R. PART 16.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Lifesaving
Issued 6 March 1996 Resolved
PROCURE AT A MINIMUM ELEVEN (11) CHILDRENS LIFE JACKETS TO MAINTAIN AT LEAST 30 CHILDRENS LIFE JACKETS.
Condition: Unknown
Due 7 March 1996
Resolved 8 March 1996
Electrical
Issued 6 March 1996 Resolved
REMOVE BARE BULB DROP LIGHT FROM TOP OF #2 (PORT) GENERATOR.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Electrical
Issued 6 March 1996 Resolved
INSTALL LIGHT COVERS IN STEERING ROOM.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Electrical
Issued 6 March 1996 Resolved
PROPERLY LABEL ALL BREAKERS AND BREAKER PANELS.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Electrical
Issued 6 March 1996 Resolved
INSTALL LIGHT COVER IN AFT BERTHING.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Electrical
Issued 6 March 1996 Resolved
INSTALL LIGHT SWITCH COVER IN AFT BERTING, PORT AFT OVERHEAD.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Electrical
Issued 6 March 1996 Resolved
INSTALL LIGHT SWITCH HANDLE, BOTH BERTHING ROOMS.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Electrical
Issued 6 March 1996 Resolved
PROPERLY INSTALL SUPPLY WIRE TO ELECTRIC BLOWER IN AFT BERTHING AND LABEL BLOWER SWITCH.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Electrical
Issued 6 March 1996 Resolved
REMOVE ALL UNUSED WIRES THROUGHOUT VESSEL.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Accommodation/Occupational Safety
Issued 6 March 1996 Resolved
FIND SEWAGE LEAK IN STEERING COMPARTMENT AND EFFECT REPAIRS.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Lifesaving
Issued 6 March 1996 Resolved
LABEL LIFE JACKET LOCKERS WITH NUMBER OF ADULT AND NUMBER OF CHILDREN'S LIFE JACKETS.
Condition: Unknown
Due 6 March 1996
Resolved 6 March 1996
Lifesaving
Issued 6 March 1996 Resolved
RENEW EPIRB BATTERY.
Condition: Unknown
Due 6 March 1996
Resolved 8 March 1996
Lifesaving
Issued 6 March 1996 Resolved
RENEW 3 EACH RING BUOYS.
Condition: Unknown
Due 6 March 1996
Resolved 8 March 1996
Construction/Loadline
Issued 1 December 1995 Resolved
AT NEXT U.S. PORT; FOUR BOTTOM PLATE INSERTS TO BE EXAMINED WITH VESSEL AFLOAT.
Condition: Unknown
Due 1 December 1995
Resolved 1 December 1995
Lifesaving
Issued 7 July 1995 Resolved
INSTALL PERMANENT PROTECTIVE GUARDS FOR PERSONNEL AROUND STBD SSDG CRANKSHAFT PULLEY.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Lifesaving
Issued 7 July 1995 Resolved
INSTALL PERMANENT PROTECTION FOR PERSONNEL AROUND BOTH MDE VIBRATION DAMPERS.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Accommodation/Occupational Safety
Issued 7 July 1995 Resolved
MAKE PERMANENT REPAIRS TO PROPERLY SECURE MSD PUMPS TO MOUNTINGS AND INSTALL WIRING USING APPROPRIATE GROMMET OR "BX" CLAMP.
Condition: Unknown
Due 7 July 1995
Resolved 7 July 1995
Construction/Loadline
Issued 10 May 1995 Resolved
CLEAN/REMOVE RUST SCALE AND OLD PAINT FROM ALL INTERNAL MEMBERS AND FLOOR BOARD SUPPORTS IN THE VICINITY OF THE LADDER INTO THE FORWARD BUNK COMPARTMENT AND MAKE THE SAME AVAILABLE FOR INSPECTION.
Condition: Unknown
Due 10 May 1995
Resolved 10 May 1995
Engineering
Issued 10 May 1995 Resolved
COMPLETE INSTALLATION OF SHIP SERVICE GENERATOR KEEL COOLER.
Condition: Unknown
Due 1 December 1995
Resolved 1 December 1995
Engineering
Issued 10 May 1995 Resolved
UPON COMPLETION OF INSTALLATION OF KEEL COOLER REMOVE SSG RAW WATER DUPLEX STRAINER AND BLANK OFF RAW WATERLINE AT THE SEA VALVE.
Condition: Unknown
Due 1 December 1995
Resolved 1 December 1995
Lifesaving
Issued 9 March 1995 Resolved
REPAIR PERSONNEL SAFETY COVER AROUND AIR COMPRESSOR DRIVE BELTS.
Condition: Unknown
Due 9 April 1995
Resolved 22 March 1995
Electrical
Issued 9 March 1995 Resolved
INSTALL BLANK COVER OR BLANK CIRCUIT BREAKER AT OPENING IN 115V AC CIRCUIT BREAKER PANEL IN ENGINE ROOM.
Condition: Unknown
Due 9 April 1995
Resolved 22 March 1995
Lifesaving
Issued 9 March 1995 Resolved
INSTALL SAFETY COVERS ON BOTH MAIN DIESEL ENGINE TIMING MARK OPENINGS AT FLYWHEEL BELL HOUSINGS.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Lifesaving
Issued 9 March 1995 Resolved
INSTALL PERSONNEL PROTECTION AROUND BOTH MAIN DIESEL ENGINE VIBRATION DAMPERS.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Lifesaving
Issued 9 March 1995 Resolved
PROVIDE SEPARATE AND MARKED STOWAGE FOR CHILD LIFE PRESERVERS.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Lifesaving
Issued 9 March 1995 Resolved
INSTALL PERSONNEL GUARD AROUND STARBOARD DIESEL GENERATOR CRANKSHAFT PULLEY.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Fire Fighting
Issued 9 March 1995 Resolved
RENEW EMERGENCY FUEL SHUT OFF VALVE LABEL.
Condition: Unknown
Due 9 April 1995
Resolved 22 March 1995
Lifesaving
Issued 9 March 1995 Resolved
MAKE ALL LIFEFLOAT PAINTERS, LIFE LINES AND FLOAT LIGHT LANYARDS FREE FROM ENTANGLEMENT AND ENSURE FLOAT FREE INSTALLATION.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Construction/Loadline
Issued 9 March 1995 Resolved
REMOVE EXCESSIVE ACCUMULATION OF OIL FROM ENGINE ROOM BILGES.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Lifesaving
Issued 9 March 1995 Resolved
REPAIR INOPERATIVE FLOAT LIGHT FOR LIFEFLOAT.
Condition: Unknown
Due 9 April 1995
Resolved 22 March 1995
Lifesaving
Issued 9 March 1995 Resolved
LIMIT THE VESSEL TO 105 PERSONS ON THE OCEANS ROUTE UNTIL LIFE PRESERVER WATER LIGHTS ARE PLACED ON ALL LIFE RESERVERS. WHEN OPERATING ON THE OCEANS ROUTE THE LIFE PRESERVERS WITHOUT WATER LIGHTS MUST BE STOWED SEPARATELY AND NOT USED.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Accommodation/Occupational Safety
Issued 9 March 1995 Resolved
PROPERLY SECURE MARINE SANITATION DEVICE PUMPS TO MOUNTINGS AND INSTALL WIRING USING APPROPRIATE GROMMET OR "BX" CLAMP.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Lifesaving
Issued 9 March 1995 Resolved
LIMIT THE NUMBER OF CHILDREN TO BE CARRIED ABOARD TO 16 UNTIL ADDITIONAL CHILD LIFE PRESERVERS ARE OBTAINED.
Condition: Unknown
Due 9 April 1995
Resolved 2 May 1995
Electrical
Issued 9 March 1995 Resolved
REPLACE MISSING GLOBE FOR LIGHT FIXTURE ABOVE STARBOARD DIESEL GENERATOR.
Condition: Unknown
Due 9 April 1995
Resolved 22 March 1995
Electrical
Issued 9 March 1995 Resolved
REMOVE DEAD-ENDED WIRE RUNS FROM ENGINE ROOM.
Condition: Unknown
Due 9 April 1995
Resolved 22 March 1995
Engineering
Issued 9 March 1995 Resolved
INSTALL PROTECTIVE LAGGING ON BARE EXHAUST PIPING FOR BOTH DIESEL GENERATORS.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Lifesaving
Issued 9 March 1995 Resolved
REMOVE PLASTIC OIL CONTAINERS FROM ENGINE ROOM DECKS AND BILGES.
Condition: Unknown
Due 9 March 1995
Resolved 9 March 1995
Electrical
Issued 16 December 1994 Resolved
Install light bulbs, globes and guards in fixtures in bunk room prior to carrying overnight passengers.
Condition: Unknown
Due 27 December 1994
Resolved 22 December 1994
Lifesaving
Issued 16 December 1994 Resolved
Prior to carrying passengers on oceans route provide approved lights on allrequired life jackets.
Condition: Unknown
Due 27 December 1994
Resolved 22 December 1994
Fire Fighting
Issued 16 December 1994 Resolved
Provide two additional properly serviced B-II fire extingushers prior to carrying passengers.
Condition: Unknown
Due 17 December 1994
Resolved 22 December 1994
Lifesaving
Issued 30 March 1994 Resolved
PROVIDE RINGS FOR EMERGENCY ESCAPE LADDER FROM FORWARD BERTHING AREA.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Electrical
Issued 30 March 1994 Resolved
PROVIDE BOX FOR BATTERY ON BRIDGE.
Condition: Unknown
Due 30 March 1994
Resolved 30 March 1994
Accommodation/Occupational Safety
Issued 6 January 1992 Resolved
REPLACE BROKEN WINDOWS ON DECKHOUSE.
Condition: Unknown
Due 6 January 1992
Resolved 6 January 1992
Lifesaving
Issued 6 January 1992 Resolved
REPLACED LINE IN 1 RING BUOY.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Electrical
Issued 6 January 1992 Resolved
REPAIRED STRAIN RELIEF ON FEEDER WIRE TO DOMESTIC HOT WATER HEATER.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Fire Fighting
Issued 6 January 1992 Resolved
REPLACED WORN/WASTED HOSE STATION VALVE HANDLES.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Lifesaving
Issued 6 January 1992 Resolved
REPLACED 8 FAILED BATTERY OPERATED PFD LIGHTS.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Fire Fighting
Issued 6 January 1992 Resolved
RECHARGED ONE BII CO2.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Electrical
Issued 6 January 1992 Resolved
COVERED UNUSED SPACES IN FACE OF DISTRIBUTION PANEL BY INSTALLING SPARE BREAKERS.
Condition: Unknown
Due 28 January 1992
Resolved 28 January 1992
Electrical
Issued 6 January 1992 Resolved
REPAIR WASTED KICK PIPE IN FWD TWO PORTSIDE HEADS.
Condition: Unknown
Due 6 January 1992
Resolved 6 January 1992
Accommodation/Occupational Safety
Issued 15 January 1991 Resolved
REPLACED 2 BROKEN WINDOWS DAMAGED BY FISHING GEAR AND I PILOT HOUSE WINDOW.
Condition: Unknown
Due 15 January 1991
Resolved 15 January 1991
Fire Fighting
Issued 15 January 1991 Resolved
HYDRO-TESTED AND RECHARGED BII EXT.
Condition: Unknown
Due 15 January 1991
Resolved 15 January 1991
Lifesaving
Issued 15 January 1991 Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Condition: Unknown
Due 15 January 1991
Resolved 15 January 1991
Lifesaving
Issued 15 January 1991 Resolved
RENEWED EPIRB BATTERY.
Condition: Unknown
Due 15 January 1991
Resolved 15 January 1991
Lifesaving
Issued 15 January 1991 Resolved
REPLACED DEFECTIVE PFD LIGHTS, BROKEN PADDLE AND WATERLIGHT BATTERIES.
Condition: Unknown
Due 15 January 1991
Resolved 15 January 1991
Lifesaving
Issued 3 January 1990 Resolved
PROVIDED 150 ADULT PFD'S.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Lifesaving
Issued 3 January 1990 Resolved
RENEWED PENDANTS ON LIFEFLOATS.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Lifesaving
Issued 3 January 1990 Resolved
RENEWED RING BUOY.
Condition: Unknown
Due 3 January 1990
Resolved 3 January 1990
Lifesaving
Issued 2 February 1989 Resolved
REPLACE DETERIORATED LIFE LINES ON LIFE FLOATS.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Fire Fighting
Issued 2 February 1989 Resolved
PROVIDE PRESSURE GAGE ON FIRE MAIN.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Lifesaving
Issued 2 February 1989 Resolved
PROVIDE INDIVIDUAL WATER LIGHTS FOR ALL PFD'S ABOARD.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Accommodation/Occupational Safety
Issued 12 April 1988 Resolved
REPLACE DOOR LATCH ON EMERGENCY ESCAPE FROM ENGINE ROOM.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Electrical
Issued 12 April 1988 Resolved
COVER UNUSED SECTIONS OF BRIDGE ELECTRICAL LIGHTING PANEL.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Engineering
Issued 12 April 1988 Resolved
INSTALL FLAME SHIELDS ON MAIN ENGINE FUEL FILTERS.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 12 April 1988 Resolved
REPLACE RING BUOY ON BRIDGE.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 12 April 1988 Resolved
MAKE PRMANENT REPAIRS TO LIFE PRESERVE STORAGE BOXES.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 12 April 1988 Resolved
PROVIDE INDIVIDUAL WATER LIGHTS FOR ALL PFDS ABOARD.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 12 April 1988 Resolved
REPAIR ONE WATER LIGHT FOR LIFE FLOATS.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 12 April 1988 Resolved
RENEW WORN LIFELINES ON LIFEFLOATS.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 12 April 1988 Resolved
LABEL # AND TYPE OF LIFE PRESERVERS STORED IN EACH BOX.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Electrical
Issued 12 April 1988 Resolved
REPLACE MISSING RECEPTACLE COVERS IN GALLEY.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Electrical
Issued 28 April 1987 Resolved
PROVIDE GLOBES AND GUARDS FOR ALL LIGHT FIXTURES IN ENGINEROOM.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Construction/Loadline
Issued 28 April 1987 Resolved
REPAIR WINDOWS IN SEATING/ACCOMMODATION AREA.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Electrical
Issued 28 April 1987 Resolved
PROVIDE LAGGING FOR STARBOARD GENERATOR EXHAUST.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Electrical
Issued 28 April 1987 Resolved
PROVIDE RETRO-FIT FOR FLAME GUARDS ON GENERATOR FUEL OIL FILTERS.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Electrical
Issued 28 April 1987 Resolved
REPLACE LIGHT FIXTURE FOR FISHING DECK LIGHT ON AFTER MAST BY STERNLIGHT.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Electrical
Issued 28 April 1987 Resolved
PROVE PROPER OPERATION OF PORT GENERATOR.
Condition: Unknown
Due 28 April 1987
Resolved 28 April 1987
Lifesaving
Issued 15 May 1985 Resolved
PROVIDE 6 DAY/6 NIGHT DISTRESS FLARES.
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985
Accommodation/Occupational Safety
Issued 15 May 1985 Resolved
REPAIR/RENEW ALL BROKEN WINDOWS IN THE VESSELS WHEELHOUSE.
Condition: Unknown
Due 15 May 1985
Resolved 15 May 1985

Casualty record · 2

12 August 2019Routine · role: Involved in a Marine Casualty · activity 6811009
30 September 2024Routine · role: Involved in a Marine Casualty · activity 8011850
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.