MAURY USCG vessel records
← All vessels

VIKING STARSHIP

Built
1977
Last inspected
8 April 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 8 April 2026
…with no type recorded4
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDH8814
Flag
UNITED STATES
Maury page id
psix-49315

Documentation record

Registered dimensions (L × B × D)117.4 ft × 25.0 ft × 7.0 ft
Registered tonnagegross 98 / net 66
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBLOUNT MARINE CORP · WARREN, RI, UNITED STATES · built 1977
Hull materialSteel
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portMONTAUK, NY
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 24 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it98 - Regulatory (Subpart C or D), Gross Ton
66 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 32 inspections, each with its date, unit and type; 100 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 32

8 April 2026 Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8344906
20 January 2026 Internal Structural Exam · Vessel Attendance · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8299392
5 February 2025 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8070425
30 September 2024 Examination of Repairs · Damage Survey · Administrative Inspection · Deficiency Check
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 8011748
30 September 2024 Type not recorded
No type recorded · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 8011850
5 September 2024 Type not recorded
No type recorded · USCGC RAZORBILL (WPB 87332) · USCG Heartland District (CGD-H) · Activity 7997335
4 April 2024 Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7889521
8 February 2024 Drydock Exam · Administrative Inspection · Examination of Repairs · Internal Structural Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7853532
22 January 2024 Administrative Inspection
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7852649
14 March 2023 Administrative Inspection · Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7650710
22 November 2022 Deficiency Check · DAPI Audit · Re-Inspection · Administrative Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7580487
25 June 2022 Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7499705
25 March 2022 Internal Structural Exam · Drydock Exam · Examination of Repairs
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 7411307
9 February 2022 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7390889
2 February 2022 Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7389569
12 July 2021 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7257098
24 November 2020 Administrative Inspection · Deficiency Check · Examination of Repairs · Annual Inspection · DAPI Audit
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 7100650
16 January 2020 Internal Structural Exam · Examination of Repairs · Drydock Exam
Physical examination · Sector Southeastern New England · USCG Northeast District (CGD-NE) · Activity 6885094
18 November 2019 Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6841896
28 October 2019 Plan Review "T" Boat
Administrative · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6843514
10 October 2019 Deficiency Check · Administrative Inspection · In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6831935
15 August 2019 Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6785113
12 August 2019 Type not recorded
No type recorded · Sector Long Island Sound · USCG Northeast District (CGD-NE) · Activity 6811009
20 November 2018 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6571778
17 September 2018 Administrative Inspection
Administrative · Navigation Center · Activity 6542248
7 February 2018 Hull Examination · Internal Structural Exam · Deficiency Check · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6353622
30 November 2017 In-Service Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6311383
21 November 2017 COI Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6294321
21 February 2017 Type not recorded
No type recorded · USCGC ALBACORE (WPB 87309) · USCG Northeast District (CGD-NE) · Activity 6282046
13 December 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 6056125
26 February 2016 Annual Inspection
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5843481
2 February 2016 Examination of Repairs
Physical examination · Marine Safety Unit Coram · USCG Northeast District (CGD-NE) · Activity 5811960

Deficiency record · 100

09 - Working and Living Conditions › 092 - Working Conditions › Danger areas
Issued 8 April 2026 Resolved
Renew engine room emergency exit signage with new glow in the dark reflective lettering
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 7 May 2026
Resolved 20 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 April 2026 Resolved
Repair exhaust lagging on starboard side MDE outboard of elbow.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 9 April 2026
Resolved 9 April 2026
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 20 January 2026 Resolved
Repair broken window on starboard main deck
Action required: 15 - Rectify deficiencies by next port
Resolved 23 April 2026
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 5 February 2025 Resolved
REPLACE LAGGING ON MDE EXHAUST.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 5 February 2025
Resolved 5 February 2025
Resolution: CORRECTED ON THE SPOT
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 5 February 2025 Resolved
PROPERLY MOUNT AND PLACE COVERS ON ELECTRICAL OUTLETS IN FWD BERTH AND FWD ACCOMODATION AREAS.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 11 February 2025
Resolution: ITEMS CORRECTED
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 5 February 2025 Resolved
REPLACE BATTERY IN FLOATLIGHT.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 19 February 2025
Resolved 11 February 2025
Resolution: BATTERY WAS REPLACED
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 30 September 2024 Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. Received report that the vessel's stbd shaft is broken and they are transiting from Montauk, NY to Goodison Shipyard in North Kingstown, RI for repairs. Prior to carrying passenger or cargo, complete repairs and conduct a sea trial to the satisfaction of the Coast Guard Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 September 2024
Resolved 16 October 2024
Resolution: See Activity Number 8011748.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2024 Resolved
Provide spanner wrenches at P/S fire stations.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2024
Resolved 16 April 2024
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 4 April 2024 Resolved
Provide ships bell
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 4 May 2024
Resolved 16 April 2024
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 4 April 2024 Resolved
Renew fire extinguisher showing required recharge.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 4 April 2024
Resolved 4 April 2024
Resolution: Corrected on the spot.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 8 February 2024 Resolved
A vessel must be fitted with ground tackle necessary for the vessel to be safely anchored or moored. Renew the identified wasted anchor winch support frames to the satisfaction of the attending marine inspector.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 February 2024 Resolved
Each window must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel. Replace 02 cracked windows on the stbd side main deck fwd. 46 CFR 177.1020
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 February 2024 Resolved
There must be no protrusions in means of escape that could cause injury, ensnare clothing, or damage life jackets. Crop and renew wasted longitudinal located at aft escape hatch in berthing area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 4 April 2024
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-corrosion
Issued 8 February 2024 Resolved
The cognizant OCMI may require that a vessel undergo any additional inspection deemed reasonable and necessary to determine that the vessel is suitable for the service in which they are employed. Clean and descale overhead area adjacent to and outboard of aft berthing hatch and make available for inspection.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 4 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 February 2024 Resolved
Footholds, handholds, and ladders must be suitable for use in emergency conditions, of rigid construction, and permanently fixed in position. Crop and renew escape ladder upper rung in aft berthing area.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 February 2024 Resolved
Each door or hatch used as a means of escape, must be capable of being opened by one person in both light and dark conditions. The method of opening a means of escape must be obvious, rapid, and of adequate strength. The location of the door handle inside of the aft escape hatch is not obvious in dark conditions and no emergency lighting is provided at the starboard outboard escape hatch.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 8 February 2024 Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR”. The stbd outboard emergency escape hatch from the berthing area is not marked.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 February 2024 Resolved
The name of the vessel and hailing port must be marked on some clearly visible exterior part of the stern of the vessel. No name or hailing port is visible on the stern.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2024
Resolved 16 April 2024
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 8 December 2022 Resolved
Decommissioned 07 adult PFDs but vessel had extras onboard and remain above the passenger carrying capacity. Deficiency issued and cleared.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 December 2022
Resolved 8 December 2022
Resolution: Vessel had extras onboard.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 December 2022 Resolved
Replace port generator cover
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Port generator cover bolted down
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
Replace battery box cover straps
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Battery box covers strapped down.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
Repair air compressor cover and repair loose electrical connections
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Air compressor cover is tight and electrical connection is covered
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 8 December 2022 Resolved
Replace port side fire hose prior to carriage of passengers
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 8 January 2023
Resolved 9 December 2022
Resolution: The port side fire hose has been replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
Repair port side forward facing spotlight cover and bulb
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Port side spotlight cover and bulb replaced
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 8 December 2022 Resolved
Replace broken window on port side in main cabin and aft door
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 16 December 2022
Resolution: Windows have been replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
Replace light switch cover in space aft of wheelhouse
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Light switch cover has been replaced.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 8 December 2022 Resolved
Replace belt guard on starboard generator
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 January 2023
Resolved 9 December 2022
Resolution: Belt guard on STB generator repaired.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 8 December 2022 Resolved
Hardwire pump in lazarette as discussed with vessel rep.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 December 2022
Resolved 9 December 2022
Resolution: Pump in lazarette has been hardwired.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 9 June 2022 Resolved
A vessel must be fit with ground tackle necessary for the vessel to be safely anchored or moored. During the 2022 drydock the vessel was issued the following worklist item; crop and renew to good metal wasted gunwale and anchor foundation members in way of the bow sprit. Vessel made temporary repairs. Due to the unavailability of a stainless steel welder at the ship yard, the vessel is authorized to complete permanent repairs in it's homeport within the next 30 days.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 9 July 2022
Resolved 25 June 2022
Resolution: MI received proof of repairs.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 9 February 2022 Resolved
Remove dead end electrical wire in enginroom overhead.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 9 February 2022
Resolved 9 February 2022
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 9 February 2022 Resolved
Have all fire extinguishers serviced.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 February 2022
Resolved 8 March 2022
Resolution: Received proof of compliance from O/O
09 - Working and Living Conditions › 092 - Working Conditions › Machinery
Issued 14 January 2021 Resolved
Replace belt guards on both Gensets.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2021
Resolved 26 January 2021
Resolution: Belt guards have been replaced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 January 2021 Resolved
Relabel bilge manifold.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2021
Resolved 26 January 2021
Resolution: Bilge manifold has been relabelled.
05 - Radio Communications › N/A - No Subsystem › VHF EPIRB
Issued 14 January 2021 Resolved
Replace expired hydrostatic release (Hammer) for Cat1 EPIRB.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 14 January 2021
Resolved 14 January 2021
Resolution: Corrected on the spot.
07 - Fire Safety › N/A - No Subsystem › Ventilation
Issued 14 January 2021 Resolved
Label engine room vent closures.
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 February 2021
Resolved 14 January 2021
Resolution: corrected on the spot
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 14 January 2021 Resolved
Replace or repair life floats on vessels roof. Several life floats had cracks into the polystyrene.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 15 February 2021
Resolution: Liferafts have been repaired properly.
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 14 January 2021 Resolved
Replace wood paneling where the water lights are mounted. Wood is rotten and can no longer support brackets.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 31 March 2021
Resolution: Water lights monuted correctly.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Windows, sidescuttles and deadlights
Issued 14 January 2021 Resolved
Several windows in passenger cabin are cracked. Discrepancy de
Action required: 705 - Other - as specified
Due 13 February 2021
Resolved 31 March 2021
Resolution: Deferred until next drydock. Added as a special note.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 14 January 2021 Resolved
Both MDE air intake hoses to the turbo were not correctly attached (hanging by a string/attached by a single hose clamp or wire.) Attach turbo air intake hose correctly.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 26 January 2021
Resolution: Turbo air intake hoses have been secured adequately.
09 - Working and Living Conditions › 092 - Working Conditions › Lighting (Working spaces)
Issued 14 January 2021 Resolved
Port side lamp in E/R missing guard. Replace.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 14 January 2021
Resolution: Replaced during inspection
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 14 January 2021 Resolved
Fire pump gauge would not read beyond 25psi. Require replacement and operational test of fire pump to achieve 60psi.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 February 2021
Resolved 26 January 2021
Resolution: Vessel installed a new guage and verified at pressure.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 24 November 2020 Resolved
The fixed bilge piping system had a constant drip in a section of pipe near the bilge manifold. The area of pipe around the leak was corroded and a small hole had developed.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 24 December 2020
Resolved 24 November 2020
Resolution: The crew replaced the leaking section of pipe within two hours of the deficiency being issued.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 November 2020 Resolved
The engine room bilges had an excessive amount of oily water in them. Issued a 14 day requirement to pump and clean engine room bilges.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 December 2020
Resolved 14 January 2021
Resolution: Bilges verified clean and dry on this date.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 November 2020 Resolved
Vessel's stbd side exhaust had a significant leak. Repair exhaust leak.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 January 2021
Resolved 14 January 2021
Resolution: Verified exhaust leak had been repaired. Vsl welded new exhaust and installed new flanges and exhaust lagging on stbd side.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2019 Resolved
Vessel had 02 fire hoses, when tested both leaked throughout the hose and were found un-serviceable. Replaced fire hoses with two, used, fire hoses conforming to UL19 IAW CFR.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: Replaced 2 failed fire hoses with inservice hoses from another vessel.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 18 November 2019 Resolved
Bilge suction pipe in passenger compartment must be fitted with a suitable strainer. Strainer on bilge suction piping was found wasted.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
Resolution: Installed strainer.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 November 2019 Resolved
Provide spanner wrenches at each fire station that will fit the fire hose installed.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 December 2019
Resolved 2 December 2019
Resolution: Installed spanner wrenches.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 November 2019 Resolved
The manufacturer's instructions for onboard maintenance of survival craft must be onboard vessels greater than 65 feet.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 2 December 2019
Resolution: Installed manufacturer's instructions.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 18 November 2019 Resolved
Each survival craft must be inspected monthly using the manufacturer's instructions.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 December 2019
Resolved 2 December 2019
Resolution: Logged inspections.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 18 November 2019 Resolved
Receptacle outlets must be installed to prevent improper connection. Outlet in the overnight accommodations was found with a broken plug piece lodged into it and the cover for the recepticle broken.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 December 2019
Resolved 2 December 2019
Resolution: Installed outlet cover.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 18 November 2019 Resolved
Verify and prove painter length is 100' after painter was found deteriorated due to exposure to the elements.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: Crew replaced painter line with new life float, float free, painter line assembly.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 18 November 2019 Resolved
life floats were set up to deploy in clusters where one life float was attached to a painter line and the intent was to connect 2 other life float lines, however there were no lines connecting the life floats together for this type of set up
Action required: 17 - Rectify deficiencies prior to departure
Due 18 November 2019
Resolved 18 November 2019
Resolution: O/O properly installed
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 10 October 2019 Resolved
Complete but simple instructions for the operation of the system must be located in a conspicuous place at or near the all pull boxes, stop valve controls and in the CO2 storage room. Vessel did not have accurate operating instructions at the operating station. Ensure accurate operation instructions are posted at the operating station. 46 CFR 181.20-15(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 25 October 2019
Resolution: Proper operating instructions provided.
09 - Working and Living Conditions › 091 - Living Conditions › Electrical devices
Issued 10 October 2019 Resolved
The owner or managing operator shall submit drawings, sketches, or written specifications describing the details of any proposed alterations to the cognizant [name withheld] alterations must be approved by the OCMI before work is started. Marine Inspector discovered unapproved electrical outlets installed in overnight accommodations. Remove permanently or provide plans of installation to this office for approval. 46 CFR 176.700(b)
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 25 October 2019
Resolution: Provided electrical plans.
07 - Fire Safety › N/A - No Subsystem › Ready availability of fire fighting equipment
Issued 10 October 2019 Resolved
All portable fire extinguishers installed on a vessel shall be of an approved type. Numerous portable fire extinguishers on board were not mounted with an approved mounting bracket. Mount portable fire extinguishers with proper brackets. 46 CFR 181.30-5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 25 October 2019
Resolution: fire extinguishers mounted
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 10 October 2019 Resolved
All escape hatches shall be marked on both sides "Emergency Exist, Keep Clear". Engine room escape was not labeled from the inside. Label appropriately. 46 CFR 185.30-15
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 25 October 2019
Resolution: poperly labeled
02 - Structural Conditions › N/A - No Subsystem › Bulkhead -corrosion
Issued 10 October 2019 Resolved
Machinery, and fuel tank spaces shall be separated from the accommodation spaces by watertight and/or vapor tight bulkheads of steel plate and or equivalent construction. Wasted steel bulkhead penetrations found within the engine room emergency escape. Repair bulkhead to original. 46 CFR 182.35-1(a)
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 25 October 2019
Resolution: repaired bulkhead for vapor tightness.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 10 October 2019 Resolved
Dry pipe exhausts are permissible if suitably insulated. Both port and starboard engine exhaust piping missing sections of insulation. Reinstall insulation. 46 CFR 182.20-20
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 18 November 2019
Resolved 25 October 2019
Resolution: lagging/insulation repaired
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 10 October 2019 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Starboard generator wiring found loose. Properly secure wiring on generator. 46 CFR 183.01-15(a)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 30 October 2019
Resolved 15 October 2019
Resolution: wiring secured
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2019 Resolved
Properly install/demonstrate operational readinesss of new shaft assembly
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2019
Resolved 26 August 2019
Resolution: O/O effected all repairs to running gear
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 15 August 2019 Resolved
Reinstall as original port side intermediate cutlass bearing
Condition: Placed in Improper Service
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2019
Resolved 26 August 2019
Resolution: O.O installed new cutlass
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 15 August 2019 Resolved
Reinstall as original local start wiring for port/stbd. generators
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2019
Resolved 26 August 2019
Resolution: O/O reinstalled wiring as original
02 - Structural Conditions › N/A - No Subsystem › Permanent means of access
Issued 15 August 2019 Resolved
Properly install ladder to machinery space
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2019
Resolved 26 August 2019
Resolution: O/O properly secured new ladder into machinery space
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 15 August 2019 Resolved
Stitch weld eroded fairing plate aft. transom
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 August 2019
Resolved 26 August 2019
Resolution: O/O conducted permanent reapirs to the overboard discharge
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 November 2018 Resolved
Replace 01 ring life buoy on port side. 46CFR180.70
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2018
Resolved 28 November 2018
Resolution: Provided
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 20 November 2018 Resolved
Replace/fix emergency lighting in overnight accommodation spaces- 46CFR183.432
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2018
Resolved 28 November 2018
Resolution: Provided
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 November 2018 Resolved
Secure and attach life float lights properly. 46CFR180.175
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 December 2018
Resolved 28 November 2018
Resolution: Provided
11 - Life Saving Appliances › N/A - No Subsystem › Other (life saving)
Issued 20 November 2018 Resolved
Provide lights on PFDs that are equipped properly. 46CFR180.75
Action required: 10 - Deficiency Rectified
Due 20 November 2018
Resolved 20 November 2018
Resolution: Corrected on spot
10 - Safety of Navigation › N/A - No Subsystem › Automatic Identification System (AIS)
Issued 17 September 2018 Resolved
Vsl is broadcasting greater than expected vessel length, Vsl is broadcasting no static draft information and Vsl is not broadcasting an AIS Ship Type
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 November 2018
Resolved 27 June 2019
Resolution: Verified CG NAVCEN VIVS, no AIS deficiencies pending per website.
Construction/Loadline › Hull › Hull Plating
Issued 7 February 2018 Resolved
Crop & Renew wasted aft deck (P & S), where UT readings are below .187
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 February 2018
Resolved 6 June 2018
Construction/Loadline › Hull › Hull Plating
Issued 9 January 2018 Resolved
Conduct permanent repairs to all doublers as directed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2018
Resolved 22 May 2018
Construction/Loadline › Hull › Hull Plating
Issued 9 January 2018 Resolved
Conduct permanent repairs to aft deck as directed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2018
Resolved 22 May 2018
Pollution Prevention/Response › Prevention Equipment › Marine Sanitation Device, Type II
Issued 9 January 2018 Resolved
Conduct permanent repairs to MSD tank as directed
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2018
Resolved 22 May 2018
Construction/Loadline › Hull › Longitudinal Frame
Issued 9 January 2018 Resolved
Repair as original aft outboard longitudinal below port MDE overboard in lazarette
Action required: 701 - Prior to carriage of passengers/cargo
Due 9 January 2018
Resolved 22 May 2018
Construction/Loadline › Hull › Bracket
Issued 9 January 2018 Resolved
Reinstall as original barcket that supports port MDE exhaust in aft lazarette
Action required: 705 - Other - as specified
Due 9 January 2018
Resolved 22 May 2018
Construction/Loadline › Hull › Bottom Plating
Issued 14 December 2017 Resolved
Conduct temp. reapirs to failed hull in aft passenger accomodation space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 22 December 2017
Resolution: Temp. reapirs to failed hull in aft passenger accomodation space completed
Construction/Loadline › Hull › Bottom Plating
Issued 14 December 2017 Resolved
Conduct temp. reapirs to failed hull in machinery space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 22 December 2017
Resolution: temp. reapirs to failed hull in machinery space completed
Construction/Loadline › Hull › Hull Plating
Issued 14 December 2017 Resolved
Conduct temp. reapirs to failed transom plating
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 14 December 2017
Resolved 9 January 2018
Resolution: Temp. reapirs to failed transom plating completed
Construction/Loadline › Hull › Hull Plating
Issued 14 December 2017 Resolved
Conduct temp. repiars incurred while departing dry dock to the shell plate iwo of the first intermediate inboard longitudinal frame from the chine at the #3 aft port transverse frame, located in the aft passenger sleeping accommodations space
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 26 December 2017
Resolved 9 January 2018
Resolution: Doubler installed
Construction/Loadline › Hull › Bottom Plating
Issued 8 December 2017 Resolved
Conduct UT's as directed in Focsle space
Action required: 705 - Other - as specified
Due 8 December 2017
Resolved 22 May 2018
Resolution: UT's conducted, O/O has results
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2017 Resolved
Conduct UT's as directed 6in. on center, Port side MDE, outboard, fwd. to aft blkhed. of machinery space.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 22 December 2017
Resolution: UT's conducted, O/O has copies
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2017 Resolved
Conduct UT's as directed 12in. on center, Port side MDE, outboard, fwd. to aft blkhed. of machinery space.
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 22 December 2017
Resolution: UT's conducted, O/O has copies
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2017 Resolved
Conduct UT's as directed 6in. on center, bottom plate of lazarette
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 22 December 2017
Resolution: UT's conducted, O/O has copies
Construction/Loadline › Hull › Bottom Plating
Issued 7 December 2017 Resolved
Conduct UT's as directed 6in. on center, bottom plate of lazarette
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 22 December 2017
Resolution: UT's conducted, O/O has copies
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 7 December 2017 Resolved
Make available for inspetion aft ballast tank
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 22 May 2018
Construction/Loadline › Hull › Stringer
Issued 7 December 2017 Resolved
Conduct permanent repairs to fractured transverse frame in bay 2, port side of fwd. accomodation space
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 22 May 2018
Construction/Loadline › Hull › Weld
Issued 7 December 2017 Resolved
Repair cracked weld, 01 deck, stbd. side
Condition: Improper/Lack of Maintenance
Due 7 December 2017
Resolved 22 May 2018
Construction/Loadline › Hull › Weld
Issued 7 December 2017 Resolved
Conduct permanent repairs pax. rail, 01 deck, stbd. side
Due 7 December 2017
Resolved 22 May 2018
Engineering › Bilge Water Management System › Strainer
Issued 7 December 2017 Resolved
Conduct permanenet repairs to bilg pick up in aft passenger bunk room space
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 22 December 2017
Resolution: Permanenet repairs conducted
Construction/Loadline › Hull › Side Shell
Issued 7 December 2017 Resolved
Conduct UT's as directed fwd. passenger space, thinned plate identified during close up
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 7 December 2017
Resolved 22 December 2017
Resolution: UT's conducted, O/O has copies
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 30 November 2017 Resolved
Install new Cutlass bearings Port/Starboard fore and aft
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 22 December 2017
Resolution: New cutlasses installed
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 30 November 2017 Resolved
Provide survey reports for Shafts, port shaft found worn by line entanglement, starboard shaft found with multiple horizontal fractures
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 22 December 2017
Resolution: Shafts serviced ashore and reinstalled
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 30 November 2017 Resolved
Properly light and make available for inspection all spaces
Condition: Improper/Lack of Maintenance
Due 30 November 2017
Resolved 22 May 2018
Construction/Loadline › Hull › Side Shell
Issued 30 November 2017 Resolved
Open and make available for inspection over board port exhaust for MDE at shell plate
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 November 2017
Resolved 22 December 2017
Resolution: Made available for inspection e
Electrical › Lighting (service) › Lighting Fixture
Issued 27 November 2017 Resolved
Replace guards on all lighting fixtures in berthing areas.
Condition: Improper/Lack of Maintenance
Due 15 December 2017
Resolved 6 June 2018
Lifesaving › Lifefloat › Serviceable
Issued 21 November 2017 Resolved
Recondition or replace life floats
Condition: Improper/Lack of Maintenance
Due 15 February 2018
Resolved 6 June 2018
Resolution: All life-floats have been temp repaired with [name withheld] patch kit.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 21 November 2017 Resolved
relabel ring bouys
Condition: Improper/Lack of Maintenance
Due 27 November 2017
Resolved 27 November 2017
Resolution: Corrected on the spot.
Lifesaving › Lifefloat › Paddle
Issued 13 December 2016 Resolved
Label all paddles
Condition: Placed in Improper Service
Due 20 December 2016
Resolved 13 December 2016
Resolution: Corrected on the spot
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 13 December 2016 Resolved
Relabel ring buoys
Condition: Placed in Improper Service
Due 20 December 2016
Resolved 13 December 2016
Resolution: Corrected on the spot
Electrical › Lighting (service) › Lighting Fixture
Issued 13 December 2016 Resolved
install globes on light fixtures in berthing
Condition: Placed in Improper Service
Due 20 December 2016
Resolved 13 December 2016
Resolution: Corrected on the spot

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.