← All vessels
HIGH CHALLENGE
HIGH CHALLENGE is a 1999 tank ship. The Coast Guard has recorded 14 inspections since 1999, most recently in January 2009, along with 16 deficiencies and 4 operational controls.
Records from 1999 to 2009. Most recent: inspection, 12 January 2009.
- Built
- 1999
- Last inspected
- 12 January 2009
- Documentation
- Not in the documentation file of 10 September 2026
- Deficiencies
- 16 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
9174608 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
ELWL8
493203
Flag
LIBERIA
—
Maury page id
psix-493203
Inspections, by type
…with no type recorded7
Years with a record
7 calendar years (1999–2009)
The 14 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
This record may be incomplete: the most recent inspection recorded for this vessel was 17 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Tank Ship class in Maury's sources begin in 1980.
Documentation record
Tonnage as PSIX records it28238 - Convention (Subpart B), Gross Ton
12462 - Convention (Subpart B), Net Ton
39999 - Dead Weight, Ton
56091 - Displacement, Ton
12462 - Convention (Subpart B), Net Ton
39999 - Dead Weight, Ton
56091 - Displacement, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Radio station licence
No FCC ship-station licence is recorded against this Official Number in the file of
6 September 2026. That is a fact about the licence file, not about the radio.
Inspection history · 14
12 January 2009
Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3392916
27 December 2008
Ballast Water Examination · ISPS I Exam · COC-CHEM Renew
Physical examination · Marine Safety Unit Brownsville · USCG Heartland District (CGD-H) · Activity 3385344
16 May 2008
Administrative Inspection · Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3208022
15 May 2008
Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3207414
5 December 2007
COC-CHEM Annual · ISPS II Exam
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 3109383
10 October 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2797488
9 October 2006
Type not recorded
No type recorded · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2796708
6 October 2006
ISPS II Exam · Ballast Water Examination · COC-CHEM Renew
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 2795192
26 April 2002
Certificate of Compliance
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1609769
2 June 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 278316
2 June 2000
Tank Vessel Examination
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1050796
25 February 2000
Type not recorded
No type recorded · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 275122
17 May 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 428625
17 May 1999
Tank Vessel Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 798469
Deficiency record · 16
Engineering › Steering Gear System › Power Unit
Issued 5 December 2007
Resolved
#2 STEERING SYSTEM DOES NOT OPERATE IN HAND MODE. SOLAS 74 II-1 REG 29
RECTIFY DEFICIENCY PRIOR TO MOVEMENT TO THE SATISFACTION OF CLASS AND FLAG STATE
Engineering › Steering Gear System › Valve
Issued 5 December 2007
Resolved
PRESSURE GUAGE TO THE 31 STEERING SYSTEM IS BROKEN
SOLAS 74 CH II-1 REG 29
RECTIFTY TO THE SATISFACTION OF CLASS AND FLAG STATE PRIOR TO DEPARTURE
Electrical › Electric Supply System (service) › Cable
Issued 5 December 2007
Resolved
Electric wire conduits broken at #1 steering system, port power pack and IGS generator. SOLAS 74 Chapter II-1/45 Code 17A&B Rectify deficiency to the satisfaction of class & flag prior to departure.
Pollution Prevention/Response › Prevention Equipment › Oily Water Separator (15 ppm)
Issued 5 December 2007
Resolved
The OWS has a pipe connection labled "RE-CIRC" that is installed after the 3-way valve but before the overboard valve. The recirculation pipe system, if installed, should be before the 3-way valve. MARPOL 73/78 Annex I/12 Code 70AB
Rectify deficiency to the satisfaction of class and flag prior to next U.S. port after sailing foreign.
Fire Fighting › Means of Escape › Blocked
Issued 5 December 2007
Resolved
THE DOOR FROM THE WEATHER DECK TO THE EMERGENCY FIRE PUMP WAS FOUND WITH A DEAD BOLT FROM THE INSIDE PREVENTING ACCESS IN THE EVENT OF AN ENGINE ROOM FIRE. SOLAS 74 II-2 REG 10.2.2.3.2.2
RECTIFY DEFICIENCY TO THE SATISFACTION OF CLASS AND FLAG STATE PRIOR TO DEPARTURE
Personnel › Training › Stability/Ballast Control
Issued 5 December 2007
Resolved
The tank levels are not being recorded on the "Sounding Board" or being kept in a log so that the engineer on watch does not know the levels of all tanks. STCW 95 A-VIII 4-2 100.3 CODE 15b Rectify deficiencies by next port to the satisfaction of Administration
Fire Fighting › Structural - A Class Divisions › Doors
Issued 5 December 2007
Resolved
BOTH DOORS BETWEEN THE ENGINE ROOM AND STEERING ROOM WERE FOUND OPEN WITH HOLD BACKS INSTALLED. IN THE EVENT OF AN ENGINE ROOM FIRE THE CO2 SYSTEM WOULD BECOME COMPROMISED SOLAS 74 CH I REG 11
TO BE RECTIFIED TO THE SATISFACTION OF CLASS AND FLAG STATE PRIOR TO DEPARTURE
Lifesaving › Inflatable Liferafts › Float Free
Issued 5 December 2007
Resolved
All four inflatable life raft where not float free where attached to the cradle frame and the actuator line was not attached. SOLAS 74 and III/13.4.2 CODE 10c
Documentation › Logs/Records › Oil Record Book
Issued 5 December 2007
Resolved
THE C-11 AND C-12 ENTRIES IN THE OIL RECORD BOOK ARE MIXED TOGETHER AND THE WEEKLY BOOK ARE MIXED TOGETHER AND THE WEEKLY CONDITION OF TANK LEVELS IS NOT ENTERED CONSISTANTLY MARPOL 73/78 APPENDIX III OF ANNEX I
RECTIFY DEFICIENCIES TO SATISFACTION OF ADMINISTRATION PRIOR TO NEXT PORT
Fire Fighting › Miscellaneous Items › Paint/Flammable Liquid Lockers
Issued 5 December 2007
Resolved
The spare gasoline for the rescue boat was found stored in the steering room where no protection is afforded now moved into the flammable liquid storage area(paint Locker) SOLAS 74 and I/II CODE 10c Deficiency recified to the satisfaction of the coast guard.
Deck/Cargo › Vapor Control Systems › Piping/Hoses
Issued 5 December 2007
Resolved
Port forward vapor control manifold is missing O.S. diameter stud. 46 CFR 39.20-1(6)(e) Code 70AB Rectify deficiency to the satisfaction of class & administration prior to next U.S. port after sailing foreign.
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 6 October 2006
Resolved
[withheld — contains personal information; the deficiency system, dates, and resolution status are shown above]
Deck/Cargo › Inert Gas System › Deck Water Seal
Issued 6 October 2006
Resolved
Deck seal low-level float switch leaking air and cannot be confirmed to be operating properly. Provide flagstate survey of proper deck seal operation. 74SOLAS (Amended) II-2 Reg 62.10.1
Deck/Cargo › Inert Gas System › Inert Gas Generator (IGG)
Issued 6 October 2006
Resolved
Cargo tanks observed with high than allowable levels of oxygen in first 3 tanks tested. Further tank testing suspending to allow time to notify lead inspector of atmospheirc conditions within tested cargo tanks. Provide flag state survey of the IGS and tank monitoring system reliability. 74SOLAS II-2 reg 62.19.5
Operations/Management › Vessel Safety Management › Safety/Environmental Protection Policy
Issued 6 October 2006
Resolved
3 tanks found to be above the allowable 8% oxygen content and created a hazardous condition which illustrated substandard implementation of the ships Safety Management System (SMS) since procedures were not in place to ensure safe ship operation. 74SOLAS(Amended) IX and ISM Code 1.2.2.1 & 1.4.2
Navigation
Issued 17 May 1999
Resolved
Vessel was missing the label for the ARPA. Correct prior to next U.S. port.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.