MAURY USCG vessel records Sign in
← All vessels

ALOHA SPIRIT

ALOHA SPIRIT is a 1977 passenger vessel (inspected). The Coast Guard has recorded 63 inspections since 1985, most recently in February 2026, along with 76 deficiencies and 1 casualty investigation in 2002.

Records from 1985 to 2026. Most recent: inspection, 10 February 2026.

Built
1977
Last inspected
10 February 2026
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDK2392
Flag
UNITED STATES
368464920
Maury page id
psix-49324

Inspections, by type

…with no type recorded7
Years with a record 39 calendar years (1985–2026)
The 63 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)61.6 ft × 18.5 ft × 7.1 ft
Registered tonnagegross 58 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · WESTPORT, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portCHANNEL ISLANDS, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationValid · issued 23 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
44 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDQ8743MMSI 368464920 · active · compulsorily equipped · granted 1 April 2026, expires 1 April 2036
WDK2392MMSI 367310460 · cancelled · compulsorily equipped · granted 2 May 2018, cancelled 17 February 2026
WTG8178MMSI 367310460 · expired · compulsorily equipped · granted 28 August 2007, cancelled 18 November 2017
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 63

10 February 2026 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8324643
18 February 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8078284
20 May 2024 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7915551
4 March 2024 Hull Examination · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7873713
21 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7673160
13 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608629
5 May 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7442643
2 March 2022 Hull Examination · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7404454
29 March 2021 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7165152
10 March 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6923851
19 February 2020 Internal Structural Exam · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6910282
25 June 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6718835
31 May 2018 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6437236
3 April 2018 Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6386906
16 May 2017 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6147951
27 May 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5887408
29 February 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5823907
20 March 2014 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4819600
15 June 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4345314
23 May 2012 Damage Survey
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4321148
27 December 2011 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4214478
11 February 2011 Deficiency Check · Drydock Exam · Plan Review "T" Boat · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3952670
23 February 2010 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3684726
12 May 2009 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3480856
23 April 2009 Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3462114
6 May 2008 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3199915
3 April 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3170022
24 May 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2993897
2 April 2007 Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2993037
30 May 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2664285
13 June 2005 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2348627
3 May 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2348279
25 April 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2342133
18 November 2004 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2237164
2 June 2004 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2086295
23 December 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1720719
25 November 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1710711
13 October 2002 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1692553
8 March 2002 Annual Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1492214
30 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 772601
1 March 2001 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1370029
1 February 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1060389
30 March 2000 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1365672
19 May 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1391025
12 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1125657
26 January 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805411
20 March 1998 COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1392893
8 April 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1454434
27 March 1996 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1079735
24 March 1995 COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1138623
23 March 1994 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1165871
13 May 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1137507
27 April 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 838090
26 March 1992 COI Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1260133
7 May 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 908098
4 April 1990 Re-Inspection · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 909937
27 March 1989 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 890798
27 May 1988 Hull Examination · Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1195394
6 April 1988 Drydock Extension
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1343265
18 May 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1024173
27 March 1986 Credit Drydock · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1305918
14 May 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1291395
11 April 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1288877

Deficiency record · 76

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 February 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Navigation chart was not up-to-date. Provide updated chart for intended voyage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 27 February 2025
Resolution: Operator provided photos of charts.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 May 2024 Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR part 80. Vessels operated beyond the 20 nautical mile limitation, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter in addition to the VHF-DSC radiotelephone installation. Vessel's VHF radio did not have the MMSI number programmed. 47 CFR 80.905(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 May 2024
Resolved 20 May 2024
Resolution: Corrected in the presence of the attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 April 2023 Resolved
At each initial and subsequent inspection for certification and reinspection the inspector shall examine and test all items in the ship's outfit, such as ground tackle, navigation lights, compass, etc., which are required to be carried by the regulations in this sub chapter. Such examination and test shall be to the extent necessary to determine that the condition of the item is satisfactory and that it is fit for the service intended. Replace broken anchor light and starboard running light. 46 CFR 176.25-40 "OLD-T"
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 1 May 2023
Resolution: Vessel rep sent pictures showing bulb replacement for deficient nav lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 April 2023 Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Re-seal forward aspect of engine room access compartments. 46 CFR 176.25-1 "OLD-T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 2 May 2023
Resolution: Vessel rep sent photo of engine compartment sealing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Remove dead end wires from beneath the steering console. 46 CFR 183.01-15 "OLD T"
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 1 May 2023
Resolution: Dead end wires removed, def cleared.
Electrical › Electrical Distribution System (service) › Conductor
Issued 17 May 2017 Resolved
Identified improper installation of 110V circuit located in the Engine Room on the aft bulkhead.Installation contained a single copper strand conductor not allowed for use in a Marine application. No Plan Review completed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: 110V Circuit was removed.
Engineering › Bilge Water Management System › Pump
Issued 17 May 2017 Resolved
Bilge pump in Lazarette was not in its base and not permanently mounted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 May 2017
Resolution: Installed bilge pump in bracket.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 May 2017 Resolved
5 float lights contained expired batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Batteries in All float Lights were replaced.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 17 May 2017 Resolved
Pre-Engineered fire extinguishing system was not inspected by a certified servicing facility within the last year. It has been 13 months since the last servicing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 6 July 2017
Resolution: System was inspected.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2017 Resolved
Exposed wires on aft bulkhead of Engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Wire was removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2017 Resolved
Exposed Wire on Aft Bulkhead beneath the fwd accomodation hold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Wire was removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2017 Resolved
Exposed wires on ceiling over stove.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Cover was installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2017 Resolved
Breaker Panel in forward compartment did not have a protective cover. Wires are exposed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2017
Resolved 13 June 2017
Resolution: Cover was installed.
Communications › Radio Communications › EPIRB
Issued 17 May 2017 Resolved
EPIRB battery expired in 2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Battery was replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 17 May 2017 Resolved
Fire Extinguisher Storage in port aft storage locker labeling is not legible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 17 May 2017
Resolution: Re-Labeled Placard.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2017 Resolved
Light Fixture in forward hold of accommodation space does not have a protective cover.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 13 June 2017
Resolution: New light fixture was installed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 May 2017 Resolved
Waste Receptacles are not of a material to contain a fire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Plastic Receptacles were removed.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 May 2017 Resolved
Hydrostatic Release does not have an installation date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: New Hydrostatic Release was installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2017 Resolved
Light fixture in aft starboard storage locker does not have an protective cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: New Light Fixture was installed.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 15 June 2012 Resolved
Prove proper operation of all water lights on life jackets in accordance with 46 CFR 180.75
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 16 August 2012
Resolution: Received receipt for purchase of required PFD waterlights.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 15 June 2012 Resolved
Properly mark all life jackets with serviceable retro reflective tape in accordance with 46 CFR 185.604
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 16 August 2012
Resolution: Received pictures with retroreflective tape added to PFDs.
Fire Fighting › Structural - A Class Divisions › Machinery Spaces
Issued 15 June 2012 Resolved
Make for and aft bulkheads in engine room vapor proof and watertight in accordance with 46 CFR 181.20-35
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 16 August 2012
Resolution: Received picture showing properly sealed engine room bulkhead.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 15 June 2012 Resolved
Provide an up to date first aid kit in accordance with 46 CFR 184.710.
Condition: Invalid
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 16 August 2012
Resolution: Received receipt of purchase for a Coast Guard approved first aid kit.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 June 2012 Resolved
Properly dead end all electric wires within the engine room in accordance with 46 CFR 183.01-15
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 16 August 2012
Resolution: Received picture showing installed junction box with dead ended wires inside.
Electrical › Electrical Distribution System (service) › Wiring
Issued 15 June 2012 Resolved
Install metallic supports at not more than 24 inches apart on all new installation of wire in lazarette in accordance with 46 CFR 183.340 (a) (4)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 July 2012
Resolved 16 August 2012
Resolution: Received picture showing wire installed with metallic wire supports and rubber anti-chaffing applied.
Construction/Loadline › Hull › Side Shell
Issued 23 May 2012 Resolved
Make proper repairs to port side hull crack located above the waterline. Provide attending CG Marine Inspector with repair proposal prior to beginning repair. Cite: 46CFR176.700. Prior to carrying passengers.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 May 2012
Resolution: Found that the port side hull was only cracked through a few layers of glass. Gave owner 60 days to affect repairs. Recieved photo of completed repairs on 25MAY12.
Construction/Loadline › Hull › Side Shell
Issued 23 May 2012 Resolved
Make proper repairs to port side hull crack located above waterline. Provided attending CG Marine Inspector with repair proposal prior to beginning repairs. Cite: 46CFR176.700. Due 26JUL12.
Condition: Damaged By Earlier Event
Due 26 July 2012
Resolved 18 June 2012
Resolution: Witnessed satisfacotry repair. Sounded inside and outside, repair is satisfactory.
Fire Fighting › Ventilation Systems › Fans
Issued 11 February 2011 Resolved
Provide a means to automatically shut down the power ventialation to engine space and prove proper operation IAW 46 CFR 181.420(a)(3).
Condition: Improper Installation
Due 30 May 2011
Resolved 16 May 2011
Resolution: Witnessed proper operation of power ventilation shut down after installation of appropriate relay switch.
Navigation › Piloting/Steering › Inland Navigation Rules
Issued 1 March 2010 Resolved
Provide current copy of inland navigation rules onboard.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 April 2010
Resolution: Provided a current copy of the navigational rules.
Navigation › Piloting/Steering › Coast Guard Light List
Issued 1 March 2010 Resolved
Provide current copy of the CG light list onboard.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 April 2010
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 March 2010 Resolved
Provide current copy of the U.S. coast pilot onboard.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 April 2010
Navigation › Piloting/Steering › US Coast Pilot
Issued 1 March 2010 Resolved
Provide current copy of the U.S. coast pilot onboard.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 April 2010
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 1 March 2010 Resolved
Renew/Replace starboard running light cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 1 March 2010
Resolution: Operator was able to clean the lens to show proper color.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 1 March 2010 Resolved
Prove proper operation of lights on 10 adult lifejackets.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 1 March 2010
Resolution: Replaced batteries on lifejacket lights.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 1 March 2010 Resolved
Re-name 01 adult lifejacket to the proper name of the vessel.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 1 March 2010
Resolution: Stenciled the proper name of the vessel on lifejacket.
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 1 March 2010 Resolved
Properly attach life ring buoy waterlight to the body.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 1 March 2010
Lifesaving › Lifefloat › Serviceable
Issued 1 March 2010 Resolved
Properly repair holes and cracks on 10 person lifefloat on fwd pilot house.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 April 2010
Resolution: Replaced 10 man lifefloat.
Lifesaving › Lifefloat › Serviceable
Issued 1 March 2010 Resolved
Properly repair hole and cracks on 15 person lifefloat on starboard pilothouse.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 April 2010
Resolution: Replaced 15 person lifefloat on starboard pilothouse.
Lifesaving › Lifefloat › Float-free Link
Issued 1 March 2010 Resolved
Replace both float free weak links for lifefloat arrangement.
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 April 2010
Resolution: Provided the correct documentation proving thst the lifefloat weak links were CG approved.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 1 March 2010 Resolved
Install exhaust insulation on both MDE inboard exhaust pipes between the manifold and the water cooled inlet.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 April 2010
Resolution: Properly installed exhaust insulation on both inboard pipes for both main engines.
Engineering › Fuel Oil Service System › Ventilation
Issued 1 March 2010 Resolved
Install 30x30 mesh flame screens on both fuel tank vents.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 April 2010
Resolution: Properly installed flame screen on both tank vents.
Lifesaving › Lifefloat › Retroreflective Material
Issued 23 February 2010 Resolved
Renew/replace all retro-reflective material on all lifefloats.
Condition: Unknown
Action required: 705 - Other - as specified
Due 1 April 2010
Resolved 29 April 2010
Resolution: Replaced all rettroreflective material on all life floats.
Lifesaving › Lifefloat › Serviceable
Issued 7 April 2008 Resolved
Repair all life floats with approved reapir kit.
Due 7 May 2008
Resolved 9 May 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 7 April 2008 Resolved
Provide current up to date charts and nautical publications.
Due 7 May 2008
Resolved 9 May 2008
Communications › Radio Communications › EPIRB
Issued 7 April 2008 Resolved
Provide expiration date for battery on EPIRB.
Due 7 May 2008
Resolved 9 May 2008
Navigation › Piloting/Steering › Coast Guard Light List
Issued 31 May 2006 Resolved
Provide current Navigation publications; U.S Coastal pilot, Coast Guard light list, and Nav. Rules.
Action required: 705 - Other - as specified
Resolved 31 May 2006
Lifesaving › Lifefloat › Float Free
Issued 31 May 2006 Resolved
Make 15 person life float, float free in way of painter line. Painter line wrapped under storage container.
Action required: 705 - Other - as specified
Resolved 31 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 31 May 2006 Resolved
Replace defective lights to 6 adult and 1 child type 1 PFD.
Action required: 705 - Other - as specified
Resolved 31 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 31 May 2006 Resolved
Properly label 3 adult and 1 child type 1 PFD's with vessel name.
Action required: 705 - Other - as specified
Resolved 31 May 2006
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 31 May 2006 Resolved
Remove and destroy 3 adult type 1 PFD's due to damaged beyond repair.
Action required: 705 - Other - as specified
Resolved 31 May 2006
Resolution: Vessel had more than required on board.
Engineering › Bilge Water Management System › Pump
Issued 13 June 2005 Resolved
Prove proper operation of new electric bilge system.
Action required: 705 - Other - as specified
Due 13 June 2005
Resolved 13 June 2005
Fire Fighting › Fixed Halon Fire Extinguishing System › Tanks
Issued 13 June 2005 Resolved
Conduct annual inspection of fixed fire System FE241
Action required: 705 - Other - as specified
Due 13 June 2005
Resolved 13 June 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 13 June 2005 Resolved
Prove proper operation of stern light.
Action required: 705 - Other - as specified
Due 13 June 2005
Resolved 13 June 2005
Lifesaving › Lifefloat › Retroreflective Material
Issued 13 June 2005 Resolved
Replace retroreflective on life floats.
Action required: 705 - Other - as specified
Due 13 June 2005
Resolved 13 June 2005
Construction/Loadline › Hull › Transverse Frame
Issued 13 June 2005 Resolved
Repair two deck frames, forward starboard side iaw. agreed upon repair proposal.
Action required: 705 - Other - as specified
Due 1 July 2005
Resolved 24 June 2005
Construction/Loadline › Hull › Hull Plating
Issued 26 April 2005 Resolved
Renew area circle in yellow near the port bow IAW NVIC 8-87.
Action required: 705 - Other - as specified
Due 26 May 2005
Resolved 3 May 2005
Construction/Loadline › Hull › Hull Plating
Issued 25 April 2005 Resolved
Provide a repair proposal for the area circle in yellow near the port bow.
Due 25 May 2005
Resolved 25 April 2005
Engineering › Bilge Water Management System › Valve
Issued 25 April 2005 Resolved
Renew the engine room electric bilge overboard valve.
Due 26 May 2005
Resolved 3 May 2005
Engineering › Fuel Oil Service System › Piping
Issued 25 April 2005 Resolved
Renew the return fuel line for the starboard main diesel engine that meets SAE-J1942 standard.
Due 25 May 2005
Resolved 13 June 2005
Stability › Watertight Integrity › General
Issued 25 April 2005 Resolved
Crop and renew the wood rot area in the aft void under the passenger space.
Action required: 705 - Other - as specified
Due 25 May 2005
Resolved 3 May 2005
Stability › Watertight Integrity › General
Issued 25 April 2005 Resolved
Provide a repair proposal for the wood rot area in the aft void under the passenger space.
Due 26 May 2005
Resolved 26 April 2005
Construction/Loadline › Structures › Superstructure
Issued 25 April 2005 Resolved
Remove the furring in the engine room.
Due 26 May 2005
Resolved 25 April 2005
Construction/Loadline › Structures › Deck Plating
Issued 25 April 2005 Resolved
Remove the mold near the aft bulkhead in the forward passenger void.
Due 25 May 2005
Resolved 25 April 2005
Stability › Watertight Integrity › General
Issued 25 April 2005 Resolved
Cap off the ball valve IVO the collision bulkhead.
Due 25 May 2005
Resolved 25 April 2005
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 April 2005 Resolved
Remove the house hold wiring.
Due 25 May 2005
Resolved 25 April 2005
Lifesaving
Issued 24 March 1995 Resolved
PROVIDE CURRENT EPIRB BATTERY. VESSEL IS LIMITED TO A COASTWISE ROUTE NOT MORE THAN 20 MILES FROM A MAINLAND SHORES UNILT THE EPIRB BATTERY IS REPLACED.
Condition: Unknown
Due 12 April 1995
Resolved 12 April 1995
Accommodation/Occupational Safety
Issued 23 March 1994 Resolved
SEAL TOP OF MSD TANK. VESSEL NOT TO OPPERATE UNTIL REQUIREMENT IS CLEARED._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 28 March 1994
Resolved 28 March 1994
Accommodation/Occupational Safety
Issued 27 April 1993 Resolved
SECURE LADDER LEADING DOWN TO ENGINE ROOM.
Condition: Unknown
Due 6 May 1993
Resolved 6 May 1993
Engineering
Issued 4 April 1990 Resolved
PROVIDE GUARDS FOR BELTS ON FORWARD ENDS OF BOTH ENGINES.
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Lifesaving
Issued 4 April 1990 Resolved
PROVIDE RETROREFLECTIVE TAPE ON SINGLE LIFE RING AND FOUR BUOYANT APPARATUS
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Engineering
Issued 4 April 1990 Resolved
PROVIDE STRAPPING TAPE TO SECURE KEEL COOLING LINES ON STARBOARD ENGINE.
Condition: Unknown
Due 4 April 1990
Resolved 4 April 1990
Construction/Loadline
Issued 27 March 1989 Resolved
BLANK-OFF 1 AND 1/2 INCH FITTING IN COLLISION BULKHEAD AT BILGE LEVEL.
Condition: Unknown
Due 27 March 1989
Resolved 27 March 1989
Engineering
Issued 27 March 1989 Resolved
PERMANENTLY MOUNT FLAME SCREEN ON STBD FUEL VENT.
Condition: Unknown
Due 27 March 1989
Resolved 27 March 1989
Lifesaving
Issued 18 May 1987 Resolved
1 PROVIDE ONE COAST GUARD APPROVED ADULT LIFE PRESERVER.
Condition: Unknown
Due 18 May 1987
Resolved 18 May 1987
Construction/Loadline
Issued 11 April 1985 Resolved
STENCIL "EMERGENCY EXIT" FOR FORWARD BERTH HATCH.
Condition: Unknown
Due 11 April 1985
Resolved 11 April 1985
Construction/Loadline
Issued 11 April 1985 Resolved
PROVIDE HOSE FOR HAND BILGE PUMP.
Condition: Unknown
Due 11 April 1985
Resolved 11 April 1985

Casualty record · 1

13 October 2002Significant Marine Casualty · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 1692553
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

NEW SEA ANGLER (2002). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record