MAURY USCG vessel records
← All vessels

ALOHA SPIRIT

Built
1977
Last inspected
10 February 2026
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 10 February 2026
Operational controls None recorded without a removal date
Years with a record 11 calendar years (2016–2026)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WDK2392
Flag
UNITED STATES
Maury page id
psix-49324

Documentation record

Registered dimensions (L × B × D)61.6 ft × 18.5 ft × 7.1 ft
Registered tonnagegross 58 / net 44
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderWESTPORT, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portCHANNEL ISLANDS, CA
Endorsements, as the file codes themcw_un, fi
DocumentationValid · issued 23 January 2026 · expires 31 January 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it58 - Regulatory (Subpart C or D), Gross Ton
44 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 17 inspections, each with its date, unit and type; 19 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; 1 other recorded name; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 17

10 February 2026 Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 8324643
18 February 2025 COI Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8078284
20 May 2024 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7915551
4 March 2024 Hull Examination · Deficiency Check · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7873713
21 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7673160
13 December 2022 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7608629
5 May 2022 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7442643
2 March 2022 Hull Examination · Internal Structural Exam · Drydock Exam · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7404454
29 March 2021 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7165152
10 March 2020 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6923851
19 February 2020 Internal Structural Exam · COI Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6910282
25 June 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6718835
31 May 2018 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6437236
3 April 2018 Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6386906
16 May 2017 Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6147951
27 May 2016 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5887408
29 February 2016 Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5823907

Deficiency record · 19

10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 18 February 2025 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Navigation chart was not up-to-date. Provide updated chart for intended voyage.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 4 March 2025
Resolved 27 February 2025
Resolution: Operator provided photos of charts.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 20 May 2024 Resolved
A vessel must comply with the applicable requirements for any radio installations as set forth in 47 CFR part 80. Vessels operated beyond the 20 nautical mile limitation, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter in addition to the VHF-DSC radiotelephone installation. Vessel's VHF radio did not have the MMSI number programmed. 47 CFR 80.905(a)(2)
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 May 2024
Resolved 20 May 2024
Resolution: Corrected in the presence of the attending Marine Inspector.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 21 April 2023 Resolved
At each initial and subsequent inspection for certification and reinspection the inspector shall examine and test all items in the ship's outfit, such as ground tackle, navigation lights, compass, etc., which are required to be carried by the regulations in this sub chapter. Such examination and test shall be to the extent necessary to determine that the condition of the item is satisfactory and that it is fit for the service intended. Replace broken anchor light and starboard running light. 46 CFR 176.25-40 "OLD-T"
Condition: Damaged By Earlier Event
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 1 May 2023
Resolution: Vessel rep sent pictures showing bulb replacement for deficient nav lights.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Machinery space openings
Issued 21 April 2023 Resolved
Vessels shall be inspected for compliance with the standards required by this subchapter. For items not covered by standards in this subchapter, inspection shall be in accordance with standards acceptable to the Officer in Charge, Marine Inspection, as good marine practice. Re-seal forward aspect of engine room access compartments. 46 CFR 176.25-1 "OLD-T"
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 2 May 2023
Resolution: Vessel rep sent photo of engine compartment sealing.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 21 April 2023 Resolved
All electrical installations shall be to the satisfaction of the Officer in Charge, Marine Inspection. Remove dead end wires from beneath the steering console. 46 CFR 183.01-15 "OLD T"
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2023
Resolved 1 May 2023
Resolution: Dead end wires removed, def cleared.
Electrical › Electrical Distribution System (service) › Conductor
Issued 17 May 2017 Resolved
Identified improper installation of 110V circuit located in the Engine Room on the aft bulkhead.Installation contained a single copper strand conductor not allowed for use in a Marine application. No Plan Review completed.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: 110V Circuit was removed.
Engineering › Bilge Water Management System › Pump
Issued 17 May 2017 Resolved
Bilge pump in Lazarette was not in its base and not permanently mounted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 May 2017
Resolved 18 May 2017
Resolution: Installed bilge pump in bracket.
Lifesaving › Lifefloat › Floating Electric Waterlight
Issued 17 May 2017 Resolved
5 float lights contained expired batteries.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Batteries in All float Lights were replaced.
Fire Fighting › Fixed Fire Detection System › Annual Inspection
Issued 17 May 2017 Resolved
Pre-Engineered fire extinguishing system was not inspected by a certified servicing facility within the last year. It has been 13 months since the last servicing.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 6 July 2017
Resolution: System was inspected.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2017 Resolved
Exposed wires on aft bulkhead of Engineroom.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Wire was removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2017 Resolved
Exposed Wire on Aft Bulkhead beneath the fwd accomodation hold.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Wire was removed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2017 Resolved
Exposed wires on ceiling over stove.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Cover was installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2017 Resolved
Breaker Panel in forward compartment did not have a protective cover. Wires are exposed.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 27 June 2017
Resolved 13 June 2017
Resolution: Cover was installed.
Communications › Radio Communications › EPIRB
Issued 17 May 2017 Resolved
EPIRB battery expired in 2016.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Battery was replaced.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Marking
Issued 17 May 2017 Resolved
Fire Extinguisher Storage in port aft storage locker labeling is not legible.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 17 May 2017
Resolution: Re-Labeled Placard.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 17 May 2017 Resolved
Light Fixture in forward hold of accommodation space does not have a protective cover.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 May 2017
Resolved 13 June 2017
Resolution: New light fixture was installed.
Accommodation/Occupational Safety › Occupational Safety › Rubbish/Waste Materials
Issued 17 May 2017 Resolved
Waste Receptacles are not of a material to contain a fire.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: Plastic Receptacles were removed.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 16 May 2017 Resolved
Hydrostatic Release does not have an installation date.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: New Hydrostatic Release was installed.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 May 2017 Resolved
Light fixture in aft starboard storage locker does not have an protective cover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 June 2017
Resolved 13 June 2017
Resolution: New Light Fixture was installed.