Records from 2016 to 2025. Most recent: inspection, 29 March 2025.
Inspection history · 21
29 March 2025
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 8102061
26 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8099569
12 March 2025
Deficiency Check · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8092179
12 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7877170
9 June 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7711091
2 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7679195
16 March 2023
Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7651690
13 January 2023
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7652144
28 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7613930
31 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7422414
30 March 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7165067
8 February 2021
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7137500
1 February 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7134156
17 March 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6927932
20 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6645830
29 January 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6616378
26 April 2018
Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6399930
30 May 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6160596
5 April 2017
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6117930
10 February 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6086355
12 April 2016
DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5851362
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 March 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Marine Inspector identified temporary repairs on the ball valve handles to connect fuel shutoff reach rod. Conduct permanent repairs to the satisfaction of the attending MI.
46 CFR 182.455(b)(4)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 28 May 2025
Resolution: Inspected and tested valve.
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 26 March 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil. Marine Inspector identified excessive accumulation of oil below hydraulic tank in midship storage void. Identify source of leak and conduct repairs to the satisfaction of the attending Marine Inspector (MI).
46 CFR 176.830(b)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 28 May 2025
Resolution: Witnessed valve tank cleaned and free of oil.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2025
Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Marine Inspector identified that cables and wires throughout the engine room, were not properly supported by metal supports. Install metal supports to all cables and wires to the satisfaction of the attending Marine Inspector.
46 CFR 183.340(b)(4)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 2 May 2025
Resolution: Received satisfactory pictures showing metal supports were installed.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Prevent electrical ignition of flammable vapors. Marine Inspector identified dead-end wires below house switch cabinet. Conduct repairs to the satisfaction of the attending Marine Inspector.
46 CFR 183.200(d)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 28 May 2025
Resolution: Witnessed wire cables terminated.
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 26 March 2025
Resolved
At a minimum, each placard must notify the reader of the operating requirements contained in §§ 151.67 through 151.73 as they apply to that ship. The following requirements should also be prominently stated:(1) The discharge of all garbage is prohibited into the navigable waters of the United States and into all other waters except as specifically allowed;(2) The discharge of all forms of plastic into all waters is prohibited; (3) person who violates the above requirements is liable for civil and/or criminal penalties; and(4) Regional, state, and local restrictions on garbage discharges also may apply. Marine Inspector identified that the garbage placard on board contained insufficient information to meet the requirement. Replace garbage placard with one that meets the requirements of 33 CFR 151.59(c).
33 CFR 151.59(c)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 28 May 2025
Resolution: Gave operator proper placard.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 26 March 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel was missing required postings at the operating station. Post emergency instructions to the satisfaction of the MI.
46 CFR 185.510(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 9 April 2025
Resolved 2 May 2025
Resolution: Received satisfactory image showing that Emergency instructions were posted.
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 12 March 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel does not have emergency instructions as required. Vessel will need to create and post emergency instructions to the satisfaction of the Marine Inspector.
46CFR185.510(a)
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2024
Resolved 22 April 2024
Resolution: Conducted def check emergency instructions was posted and found satisfactory.
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 March 2024
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR” Vessel's fwd crew accommodation space emergency exit to the bow marking was the same coloration of the hatch, and marked on only one side. Vessel most add the lettering to the accommodation side and make sure both sides are contrasting to the satisfaction of the Marine Inspector.
46CFR185.606
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 26 March 2024
Resolved 26 April 2024
Resolution: Received satisfactory photo of markings.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 March 2024
Resolved
A power-driven vessel underway shall exhibit: (iv) A stern light. Vessel's stern light was inoperable, at the beginning of the inspection. Vessel representative satisfactorily fixed the stern light, cleared on the spot.
33CFR83.23(a)(iv)
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 12 March 2024
Resolved 12 March 2024
Resolution: Vessel representative satisfactorily fixed the stern light, cleared on the spot.
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 June 2023
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Vessel sustained damage to hull after allision with 02 docked nearby vessels and dock piling. Vessel requires external and internal structural exam to determine extent of damage and effect permanent repairs prior to movement.
46 CFR 176.600 (d)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2023
Resolution: Vessel has hauled out for emergency drydock and made permanent repairs to the hull. On further inspection while vessel was out of the water, it was discovered that vessel suffered damage to hull just above waterline and cracks found in the rail. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. During transit from slip to fuel dock, vessel experienced loss of ability to control ENG throttles resulting in allision with nearby vessels. Complete cause analysis, repairs, and test of ahead/astern operation to satisfaction of attending Marine Inspector prior to movement.
46 CFR 182.200
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 12 June 2023
Resolution: Attended vessel and confirmed incorrect installation of transmission wiring harness on PORT Engine. Vessel installed connections correctly (AHEAD/ASTERN. Conducted successful sea trial of both engines in AHEAD/N/ASTERN on both operating stations.
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 9 June 2023
Resolved
The master of a vessel shall have examined and tested the steering gear, signaling whistle, propulsion controls, and communication systems of the vessel prior to getting underway for a voyage, except that such examination and testing need not be conducted more than once in any 24 hour period. Vessel suffered damage from allision with a dock while returning from the fuel dock. Owner stated that propulsion controls were sabotaged. Master of vessel shall perform examinations of all times at all stations IAW this regulation.
46 cfr 185.320
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2023
Resolution: After several tries and only with the aid of the regulation in front of him, owner was able to satisfactorily demonstrate proper underway checks.
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 May 2023
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Bulkhead penetration between the lazarette and engine room is not vapor tight. Effect repairs to the satisfaction of the attending marine inspector.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 17 May 2023
Resolved 24 May 2023
Resolution: Vapor barrier installed.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 May 2023
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's Safety Radiotelephony Certificate was not onboard the vessel.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 June 2023
Resolved 24 May 2023
Resolution: Vessel received updated Safety Radiotelephony Cert.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 March 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. By USCG Policy, a drydock examination and internal structural exam is complete when the work list assigned by the Marine Inspector is completed. Vessel has not completed work list item #2 for broken windows in the pilot house and has been operating with passengers for approximately four months past the drydock expiration date.
46 CFR 176.600(c)(1)
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 16 June 2023
Resolution: Changed worklist item 02 to a deficiency and made due 30JUN2023. Drydock workl ist now complete.
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have installed detectors in required spaces by 27Dec2022. Vessel has been limited to a Limited Coastwise route until detector installation has been verified by a Marine Inspector.
46 CFR 181.405(c)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 18 July 2024
Resolution: Tested interconnected system and was found satisfactory.
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 31 March 2022
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station an audible alarm that sounds upon discharge. Pre-engineered system's audible alarm failed to actuate at a sufficient decibel to provide clear signal to operator.
Condition: Design Flaw
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 10 May 2022
Resolution: Replaced audible alarm. Received video proof.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2022
Resolved
Each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. Three Kapok PFD's were deemed unfit for continued use based on requirements listed under Subchapter Q.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 10 May 2022
Resolution: Replaced failed Kapok with Type I PFD's
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 March 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Nonmetallic flexible 3" bilge line in engine space and mid compartment are deteriorated and missing a secondary securing clamp (mid compartment).
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 30 April 2022
Resolved 29 April 2022
Resolution: Replaced nonmetallic bilge line (see documents)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2021
Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. Port main diesel engine exhaust only had one hose clamp. Add second hose clamp.
46CFR182.430(e)
Action required: 10 - Deficiency Rectified
Resolved 30 March 2021
Resolution: Operator installed hose clamps where needed.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 March 2021
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Bulwark door only has a bottom hinge holding it in place. Install top hinge as original.
46CFR177.900(a)
Action required: 10 - Deficiency Rectified
Resolved 5 April 2021
Resolution: Operator made satisfactory repair to bulwark door hinge.
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 30 March 2021
Resolved
Switches other than those mounted on the switchboard shall be of the enclosed type. Outlet found in vicinity of midship void without cover. Replace cover.
46CFR183.05-15(d)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 April 2021
Resolution: Operator sent picture of outlet with cover installed.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 30 March 2021
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Starboard pilothouse door window has cracked window.
46CFR177.1020
Action required: 50 - Rectify deficiencies w/in 30 days
Resolved 5 April 2021
Resolution: Operator replaced pilot house door window.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 February 2021
Resolved
A vessel exposed to salt water more than three months in any 12 month period must undergo a drydock examination and internal structural exam at least once every two years. Operator did not make vessel available for January 2021 drydock.
46 CFR 176.600(c)(1)
Action required: 17 - Rectify deficiencies prior to departure
Resolved 9 February 2021
Resolution: Vessel completed credit drydock.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2020
Resolved
Three lifejackets were found unserviceable and removed from the vessel.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 23 March 2020
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2019
Resolved
Vsl carrying one ring buoy, floating light must be attached to the lanyard with a corrosion resistant clip. Floating light was tied to ring buoy body, clip added on spot.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 20 March 2019
Resolved 20 March 2019
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 March 2019
Resolved
Emergency fuel shut off valves must be marked.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 20 March 2019
Resolved 20 March 2019
Communications › Radio Communications › EPIRB
Issued 26 April 2018
Resolved
Hydrostatic release unit is expired. 46 CFR 180.64
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 4 May 2018
Resolved 2 May 2018
Resolution: Owner installed new hydostatic release unit on the vessel's EPIRB.
Documentation › Markings/Placards › Lifejacket Placard
Issued 26 April 2018
Resolved
Vessel does not have a lifejacket placard does not accurately reflect each type of PFD that is carried onboard. 46 CFR 185.516
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 10 May 2018
Resolved 2 May 2018
Resolution: Owner posted life jacket placard.
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 August 2017
Resolved
Operator failed to schedule a follow up inspection to rectify outstanding deficiencies.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 August 2017
Resolved 20 March 2019
Engineering › Bilge Water Management System › Pump
Issued 30 May 2017
Resolved
Bilge pump that operates off of the starboard engine does not have guards/protection surrounding the belts - 46 CFR 182.100
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 20 March 2019
Engineering › Feedwater/Condensate Water System › Piping
Issued 30 May 2017
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel, giving consideration to provisions for a seaworthy hull. A hose for the bait tank in the engine room had a small gouge, providing for a small leak of water. - 46 CFR 177.100
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 30 June 2017
Resolved 26 April 2018
Resolution: Owner replaced bait tank hose located in the engine room.
Construction/Loadline › Hull › Hull Plating
Issued 10 February 2017
Resolved
Vessel shall complete satisfactory dry dock inspection prior to carrying passengers. 46CFR176.600(b)(1)
Action required: 701 - Prior to carriage of passengers/cargo
Due 15 March 2017
Resolved 5 April 2017
Resolution: Completed credit DD.