← All vessels
TIGERFISH
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Southwest District (CGD-SW) · Other hulls named TIGERFISH
TIGERFISH is a 1977 passenger vessel (inspected). The Coast Guard has recorded 91 inspections since 1985, most recently in March 2025, along with 134 deficiencies and 7 operational controls.
Records from 1985 to 2025. Most recent: inspection, 29 March 2025.
- Built
- 1977
- Last inspected
- 29 March 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 134 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
585944
WDC5102
49327
Flag
UNITED STATES
367035840
Maury page id
psix-49327
Inspections, by type
…with no type recorded8
Years with a record
37 calendar years (1985–2025)
The 91 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)48.1 ft × 15.7 ft × 6.7 ft
Registered tonnagegross 38 / net 26
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderDELTA MARINE INDUSTRIES · SEATTLE, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portSAN FRANCISCO, CA
Trade endorsementsCoastwise, unrestricted, Fishery, Recreational
DocumentationValid · issued 2 March 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it38 - Regulatory (Subpart C or D), Gross Ton
26 - Regulatory (Subpart C or D), Net Ton
26 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDC5102MMSI 367035840 · active · compulsorily equipped · granted 20 May 2025, expires 22 April 2035
WBD5954MMSI not assigned · expired · compulsorily equipped · granted 12 November 1996, cancelled 7 April 2007 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 91
29 March 2025
Type not recorded
No type recorded · Station San Francisco · USCG Southwest District (CGD-SW) · Activity 8102061
26 March 2025
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8099569
12 March 2025
Deficiency Check · Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8092179
12 March 2024
Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7877170
9 June 2023
Deficiency Check · In-Service Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7711091
2 May 2023
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7679195
16 March 2023
Internal Structural Exam · Drydock Exam · Deficiency Check · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7651690
13 January 2023
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7652144
28 December 2022
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7613930
31 March 2022
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7422414
30 March 2021
Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7165067
8 February 2021
Drydock Exam · Internal Structural Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7137500
1 February 2021
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7134156
17 March 2020
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6927932
20 March 2019
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6645830
29 January 2019
Internal Structural Exam · Administrative Inspection · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6616378
26 April 2018
Annual Inspection · Administrative Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6399930
30 May 2017
Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6160596
5 April 2017
Administrative Inspection · Drydock Exam · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6117930
10 February 2017
Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6086355
12 April 2016
DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5851362
24 March 2014
Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4821911
23 March 2010
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3701129
16 April 2009
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3454916
26 March 2009
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3421081
2 February 2009
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3400156
8 January 2009
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3390534
3 March 2008
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3154102
18 December 2007
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3112952
22 February 2007
Simplified Stability Test
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2872723
15 February 2007
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2872803
22 January 2007
COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2858582
3 February 2006
Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2579030
24 January 2006
Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2572282
17 January 2006
Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2567908
17 January 2006
Plan Review "T" Boat
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2569691
24 May 2005
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2367299
4 May 2005
In-Service Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2349540
28 April 2005
Spot Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2344813
11 April 2005
Annual Inspection
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 2330782
20 January 2004
Annual Inspection · Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Humboldt Bay · USCG Southwest District (CGD-SW) · Activity 1991625
14 March 2003
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1757524
18 February 2003
Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1737167
5 February 2002
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1480893
22 January 2002
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1480256
3 April 2001
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1060025
8 February 2001
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1366162
16 February 2000
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1365597
6 January 2000
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1391176
30 December 1999
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 812645
7 April 1999
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787803
8 February 1999
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 806433
26 January 1999
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 790029
9 February 1998
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 774111
15 December 1997
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 780250
11 February 1997
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1104958
12 March 1996
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1081439
16 February 1996
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 881306
28 November 1995
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1191782
7 November 1995
Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 884358
14 November 1994
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1153645
20 September 1994
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1176177
18 August 1994
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1181910
5 August 1994
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 71206
6 December 1993
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1159900
24 February 1993
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1147844
28 December 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 831424
4 December 1992
COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 828501
6 November 1992
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1262948
21 July 1992
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 944370
13 February 1992
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 949021
17 January 1992
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 951191
17 June 1991
Administrative
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1044052
15 May 1991
Hull Examination · COI Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 910501
14 August 1990
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1219241
19 June 1990
Re-Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1236290
26 July 1989
Deficiency Check
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1350355
14 July 1989
Hull Examination · Re-Inspection
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 887461
17 June 1988
Plan Review "T" Boat
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1203914
6 June 1988
Excursion Permit
Administrative · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1202303
2 May 1988
COI Inspection · Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1040298
17 November 1987
Hull Examination
Physical examination · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1333719
28 July 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1326526
2 July 1987
Type not recorded
No type recorded · MSO PORTLAND, OREGON · USCG Northwest District (CGD-NW) · Activity 1008747
3 February 1987
Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1006764
3 December 1986
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1020635
28 November 1986
Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1328261
21 January 1986
Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1303262
9 January 1986
Credit Drydock
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1303261
26 November 1985
COI Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 996047
4 January 1985
Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 976998
Deficiency record · 134
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 26 March 2025
Resolved
Shutoff valves, installed so as to close against the fuel flow, must be fitted in the fuel supply lines, one at the tank connection and one at the engine end of the fuel line to stop fuel flow when servicing accessories. The shutoff valve at the tank must be manually operable from outside the compartment in which the valve is located, preferably from an accessible position on the weather deck. If the handle to the shutoff valve at the tank is located inside the machinery space, it must be located so that the operator does not have to reach more than 300 millimeters (12 inches) into the machinery space and the valve handle must be shielded from flames by the same material the hull is constructed of, or some noncombustible material. Marine Inspector identified temporary repairs on the ball valve handles to connect fuel shutoff reach rod. Conduct permanent repairs to the satisfaction of the attending MI.
46 CFR 182.455(b)(4)
09 - Working and Living Conditions › 092 - Working Conditions › Cleanliness of engine room
Issued 26 March 2025
Resolved
At each inspection for certification and at every other vessel inspection the bilges and other spaces may be examined to see that there is no excessive accumulation of oil. Marine Inspector identified excessive accumulation of oil below hydraulic tank in midship storage void. Identify source of leak and conduct repairs to the satisfaction of the attending Marine Inspector (MI).
46 CFR 176.830(b)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2025
Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Marine Inspector identified that cables and wires throughout the engine room, were not properly supported by metal supports. Install metal supports to all cables and wires to the satisfaction of the attending Marine Inspector.
46 CFR 183.340(b)(4)
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 26 March 2025
Resolved
Electrical equipment on a vessel must be installed and maintained to: Prevent electrical ignition of flammable vapors. Marine Inspector identified dead-end wires below house switch cabinet. Conduct repairs to the satisfaction of the attending Marine Inspector.
46 CFR 183.200(d)
14 - Pollution Prevention › 145 - MARPOL Annex V › Placards
Issued 26 March 2025
Resolved
At a minimum, each placard must notify the reader of the operating requirements contained in §§ 151.67 through 151.73 as they apply to that ship. The following requirements should also be prominently stated:(1) The discharge of all garbage is prohibited into the navigable waters of the United States and into all other waters except as specifically allowed;(2) The discharge of all forms of plastic into all waters is prohibited; (3) person who violates the above requirements is liable for civil and/or criminal penalties; and(4) Regional, state, and local restrictions on garbage discharges also may apply. Marine Inspector identified that the garbage placard on board contained insufficient information to meet the requirement. Replace garbage placard with one that meets the requirements of 33 CFR 151.59(c).
33 CFR 151.59(c)
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 26 March 2025
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel was missing required postings at the operating station. Post emergency instructions to the satisfaction of the MI.
46 CFR 185.510(a)
04 - Emergency Systems › N/A - No Subsystem › Muster list
Issued 12 March 2024
Resolved
The master and crew of a vessel will be familiar with the content of and have mounted at the operating station, emergency instructions containing the actions to be taken in the event of fire, heavy weather, or man overboard conditions. Vessel does not have emergency instructions as required. Vessel will need to create and post emergency instructions to the satisfaction of the Marine Inspector.
46CFR185.510(a)
07 - Fire Safety › N/A - No Subsystem › Means of escape
Issued 12 March 2024
Resolved
All escape hatches and other emergency exits used as means of escape must be marked on both sides in clearly legible letters at least 50 millimeters (2 inches) high: “EMERGENCY EXIT, KEEP CLEAR” Vessel's fwd crew accommodation space emergency exit to the bow marking was the same coloration of the hatch, and marked on only one side. Vessel most add the lettering to the accommodation side and make sure both sides are contrasting to the satisfaction of the Marine Inspector.
46CFR185.606
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 12 March 2024
Resolved
A power-driven vessel underway shall exhibit: (iv) A stern light. Vessel's stern light was inoperable, at the beginning of the inspection. Vessel representative satisfactorily fixed the stern light, cleared on the spot.
33CFR83.23(a)(iv)
02 - Structural Conditions › N/A - No Subsystem › Hull damage impairing seaworthiness
Issued 9 June 2023
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of a vessel is discovered or suspected, the cognizant OCMI may conduct an internal structural examination in any affected space including fuel tanks, and may require the vessel to be drydocked or taken out of service to assess the extent of the damage, and to effect permanent repairs. Vessel sustained damage to hull after allision with 02 docked nearby vessels and dock piling. Vessel requires external and internal structural exam to determine extent of damage and effect permanent repairs prior to movement.
46 CFR 176.600 (d)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 9 June 2023
Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. During transit from slip to fuel dock, vessel experienced loss of ability to control ENG throttles resulting in allision with nearby vessels. Complete cause analysis, repairs, and test of ahead/astern operation to satisfaction of attending Marine Inspector prior to movement.
46 CFR 182.200
10 - Safety of Navigation › N/A - No Subsystem › Bridge operation
Issued 9 June 2023
Resolved
The master of a vessel shall have examined and tested the steering gear, signaling whistle, propulsion controls, and communication systems of the vessel prior to getting underway for a voyage, except that such examination and testing need not be conducted more than once in any 24 hour period. Vessel suffered damage from allision with a dock while returning from the fuel dock. Owner stated that propulsion controls were sabotaged. Master of vessel shall perform examinations of all times at all stations IAW this regulation.
46 cfr 185.320
07 - Fire Safety › N/A - No Subsystem › Fire prevention structural integrity
Issued 2 May 2023
Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present, such as machinery spaces and paint lockers. Bulkhead penetration between the lazarette and engine room is not vapor tight. Effect repairs to the satisfaction of the attending marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 2 May 2023
Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel's Safety Radiotelephony Certificate was not onboard the vessel.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 March 2023
Resolved
A vessel that is exposed to salt water more than three months in any 12 month period since the last examination must undergo a drydock examination and an internal structural at least once every two years. By USCG Policy, a drydock examination and internal structural exam is complete when the work list assigned by the Marine Inspector is completed. Vessel has not completed work list item #2 for broken windows in the pilot house and has been operating with passengers for approximately four months past the drydock expiration date.
46 CFR 176.600(c)(1)
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 28 December 2022
Resolved
Vessels described by 46 CFR 175.110(c) must have an interconnected fire detection system in compliance with § 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel does not have installed detectors in required spaces by 27Dec2022. Vessel has been limited to a Limited Coastwise route until detector installation has been verified by a Marine Inspector.
46 CFR 181.405(c)
08 - Alarms › N/A - No Subsystem › Fire alarm
Issued 31 March 2022
Resolved
A vessel on which a pre-engineered fixed gas fire extinguishing system is installed must have the following equipment at the operating station an audible alarm that sounds upon discharge. Pre-engineered system's audible alarm failed to actuate at a sufficient decibel to provide clear signal to operator.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 31 March 2022
Resolved
Each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. Three Kapok PFD's were deemed unfit for continued use based on requirements listed under Subchapter Q.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 31 March 2022
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment, other than small buoyancy compartments, under all practicable conditions. Nonmetallic flexible 3" bilge line in engine space and mid compartment are deteriorated and missing a secondary securing clamp (mid compartment).
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 30 March 2021
Resolved
Nonmetallic hose may be used for wet exhaust systems provided it is especially adapted to resist the action of oil, acid, and heat, has a wall thickness sufficient to prevent collapsing or panting, and is double clamped where practicable. Port main diesel engine exhaust only had one hose clamp. Add second hose clamp.
46CFR182.430(e)
03 - Water/Weathertight Conditions › N/A - No Subsystem › Railing, gangway, walkway and means for safe passage
Issued 30 March 2021
Resolved
Except as otherwise provided in this section, rails or equivalent protection must be installed near the periphery of all decks of a vessel accessible to passengers or crew. Equivalent protection may include lifelines, wire rope, chains, and bulwarks, which provide strength and support equivalent to fixed rails. Bulwark door only has a bottom hinge holding it in place. Install top hinge as original.
46CFR177.900(a)
09 - Working and Living Conditions › 091 - Living Conditions › Pipes, wires (insulation)
Issued 30 March 2021
Resolved
Switches other than those mounted on the switchboard shall be of the enclosed type. Outlet found in vicinity of midship void without cover. Replace cover.
46CFR183.05-15(d)
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 30 March 2021
Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Starboard pilothouse door window has cracked window.
46CFR177.1020
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 1 February 2021
Resolved
A vessel exposed to salt water more than three months in any 12 month period must undergo a drydock examination and internal structural exam at least once every two years. Operator did not make vessel available for January 2021 drydock.
46 CFR 176.600(c)(1)
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 17 March 2020
Resolved
Three lifejackets were found unserviceable and removed from the vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 20 March 2019
Resolved
Vsl carrying one ring buoy, floating light must be attached to the lanyard with a corrosion resistant clip. Floating light was tied to ring buoy body, clip added on spot.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 20 March 2019
Resolved
Emergency fuel shut off valves must be marked.
Communications › Radio Communications › EPIRB
Issued 26 April 2018
Resolved
Hydrostatic release unit is expired. 46 CFR 180.64
Documentation › Markings/Placards › Lifejacket Placard
Issued 26 April 2018
Resolved
Vessel does not have a lifejacket placard does not accurately reflect each type of PFD that is carried onboard. 46 CFR 185.516
Operations/Management › Vessel Safety Management › Maintenance of Ship/Equipment
Issued 30 August 2017
Resolved
Operator failed to schedule a follow up inspection to rectify outstanding deficiencies.
Engineering › Bilge Water Management System › Pump
Issued 30 May 2017
Resolved
Bilge pump that operates off of the starboard engine does not have guards/protection surrounding the belts - 46 CFR 182.100
Engineering › Feedwater/Condensate Water System › Piping
Issued 30 May 2017
Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel, giving consideration to provisions for a seaworthy hull. A hose for the bait tank in the engine room had a small gouge, providing for a small leak of water. - 46 CFR 177.100
Construction/Loadline › Hull › Hull Plating
Issued 10 February 2017
Resolved
Vessel shall complete satisfactory dry dock inspection prior to carrying passengers. 46CFR176.600(b)(1)
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 24 March 2014
Resolved
Replace two child size life jackets
Fire Fighting › Means of Escape › Escape Route Signs
Issued 24 March 2014
Resolved
Properly label fowrward hatch for means of escape
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 24 March 2014
Resolved
Properly place machinery guards over moving parts on Main Engine
Engineering › Fuel Oil Service System › Valve
Issued 24 March 2014
Resolved
Prove proper operation of starboard emergency fuel shutoff.
Stability › Incline Test › General
Issued 3 April 2009
Resolved
This vessel may only carry 19 passengers and 2 crewmembers on an Oceans route until a new Simplified Stability Test is performed.
Stability › Incline Test › General
Issued 3 April 2009
Resolved
This vessel may only carry 39 passengers and 2 crewmembers on an Limited Coastwise and lesser route until a new Simplified Stability Test is performed.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 2 April 2009
Resolved
Submit details to this office for the re-power of both main engines as discussed on 8 JAN 2009.
Electrical › Electric Supply System (service) › Cable
Issued 3 March 2008
Resolved
Properly dead end electrical wire in accommodation void.
Engineering › Fuel Oil Storage/Transfer System › Tank
Issued 3 March 2008
Resolved
Properly ground port f/o tank.
Operations/Management › Equipment Service/Testing › EPIRB
Issued 22 January 2007
Resolved
Renew EPIRB hydrostatic release. Vessel is limited to not more than three nautical miles from shore.
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 25 January 2006
Resolved
Re-new 1 adult type I life jacket, due to broken snap .
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 25 January 2006
Resolved
Re-new 2 pieces of retro reflective tape on 1 adult type I pfd.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 January 2006
Resolved
Provide lens cover for light in void space below passenger accommodation space, forward.
Stability › Watertight Integrity › Weathertight Enclosure
Issued 25 January 2006
Resolved
Provide securing devise for lazarette hatch.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 January 2006
Resolved
Re-new port running light lens, lens badly frosted.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 January 2006
Resolved
Re-new anchor light lens, lens badly frosted.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 24 January 2006
Resolved
Re-new 2 missing lifejacket lights. Vessel is restricted to not more than 21 passengers.
Stability › Watertight Integrity › General
Issued 17 January 2006
Resolved
Modify the bait tank overboard piping so that it complies with 46 CFR 182.720(d)(1).
Engineering › Bilge Water Management System › Valve
Issued 17 January 2006
Resolved
Install a positive metallic shutoff valve near the thru hull for the electrical bilge pump overboard piping in the lazarette.
Electrical › Electric Generation Source (service) › Generator
Issued 17 January 2006
Resolved
Prove proper operation of the generator. Vessel is restricted from running generator while passengers for hire are on board.
Construction/Loadline › Structures › End Bulkhead
Issued 4 May 2005
Resolved
Abate furring above starboard MDE exhaust line in way of aft engine room watertight bulkhead.
Stability › Watertight Integrity › General
Issued 4 May 2005
Resolved
Make forward midbody compartment bulkhead watertight in way of all wiring penetrations.
Electrical › Lighting (service) › Lighting Fixture
Issued 4 May 2005
Resolved
Properly mount starboard engine room light.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 May 2005
Resolved
Correct PFD stowage signage to reflect number and type of PFD's stowed in applicable lockers.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 4 May 2005
Resolved
Properly attach required 60 foot lifeline to ring lifebuoy.
Lifesaving › Visual Distress Signals (General) › Condition
Issued 4 May 2005
Resolved
Renew ring lifebuoy floating waterlight.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 May 2005
Resolved
Eliminate excessive leakage from port rudder post packing and conduct an underway test of the same to the satisfaction of the attending MI.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 4 May 2005
Resolved
Replace forward clamp on hose between shaft packing and the shaft tube.
Engineering › Electric Propulsion System › Circuit Breaker (overload/over current protection)
Issued 4 May 2005
Resolved
Prove ability to stop port and starboard MDE from the operateing station.
Stability › Watertight Integrity › General
Issued 28 April 2005
Resolved
Remove hydraulic hoses penetrating forward engine room bulkhead, drain hydraulic storage reservoir and make forward engine room bulkhead water/vapor tight in way of hose penetrations.
Stability › Unintentional Flooding › General
Issued 28 April 2005
Resolved
Make forward engine room bulkhead water/vapor tight in way of wiring and sanitary piping penetrations.
Electrical › Lighting (service) › Lighting Fixture
Issued 28 April 2005
Resolved
Remove large lights from atop pilot house.
Operations/Management › Vessel Safety Management › Emergency Preparedness
Issued 10 April 2005
Resolved
Prior to operating vessel as a passenger carrying vessel under new ownership conduct entry into zone inspection with local CG marine inspection office.
Operations/Management › Drills/Instruction › Fire
Issued 10 April 2005
Resolved
Conduct drills to the satisfaction of attending marine Inspector.
Operations/Management › Lifesaving › Op Readiness/Maintenance/Inspection
Issued 10 April 2005
Resolved
Provide proof of Inflatable Buoyant Apparatus (IBA) service at CG approved facility.
Operations/Management › Drug and Alcohol Testing › Employee Coverage
Issued 10 April 2005
Resolved
Provide proof of vessel crew covered by CG approved Drug testing program.
Communications › Radio Communications › VHF Radiotelephone
Issued 10 April 2005
Resolved
Provide copy of radio station license
Fire Fighting › Portable CO2 Fire Extinguisher › Service
Issued 10 April 2005
Resolved
Conduct service of all fire fighting equipment.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 10 April 2005
Resolved
Provide copy of new vessel document to reflect vessel ownership transfer.
Lifesaving › Lifejacket/PFD (Type I) › Marking
Issued 10 April 2005
Resolved
Place vessel name on all life jackets.
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 10 April 2005
Resolved
Place vessel name on ring buoy.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 10 April 2005
Resolved
Replace missing 4 child and 14 adult life jackets.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 10 April 2005
Resolved
Replace lens for all around white light.
Operations/Management › Navigation Safety › Carriage of Charts and Publications
Issued 10 April 2005
Resolved
Provide copies of charts, coast pilot, light list and tide tables for operating area.
Stability › Incline Test › General
Issued 10 April 2005
Resolved
Provide plans for or remove large lights on superstructure and new hydraulic tank in space forward of engine room.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 20 January 2004
Resolved
Provide manufacture's recommended cutlass bearing wear down and provide current bearing readings. LEGACY COMPONENT DESC: Bearing
Construction/Loadline › Hull › Hull Plating
Issued 20 January 2004
Resolved
In way of aft stbd corner of vessel remove delaminated FRP and renew as original in type and quality. LEGACY COMPONENT DESC: Side Shell
Construction/Loadline › Structures › Transverse Bulkhead
Issued 20 January 2004
Resolved
In way of collision bulkhead remove rotten wood at top port and top port side of the aft access and renew.
Construction/Loadline › Hull › Hull Plating
Issued 20 January 2004
Resolved
In way of steering gear compartment remove all wasted fasteners and renew rub rail fasteners. LEGACY COMPONENT DESC: Side Shell
Construction/Loadline › Structures › Machinery Space Opening
Issued 20 January 2004
Resolved
In way of engineroom overhead outboard of both engines renew FRP where wood core is exposed.
Electrical › Electrical Distribution System (service) › Wiring
Issued 20 January 2004
Resolved
Remove all dead end wires in way of battery storage compartment.
Engineering › Fuel Oil Storage/Transfer System › Valve
Issued 20 January 2004
Resolved
In way of aft port engine room, make repairs to the emergency fuel shut off valve for the port tank. Repairs to be completed before taking passengers for hire.
Fire Fighting › Fixed Gas Fire Extinguishing System › Tanks
Issued 20 January 2004
Resolved
Provide copy of fire fighting equipment service report. Install service label on fix system.
Documentation › Logs/Records
Issued 19 February 2003
Resolved
Maintain drill log for MOB & Fire drills IAW 46 CFR 185.420. LEGACY COMPONENT DESC: Logbook/Record (unofficial)
Electrical › Electrical Distribution System (service)
Issued 19 February 2003
Resolved
Repair dead end wire in lazarette. LEGACY COMPONENT DESC: Wiring
Construction/Loadline › Structures
Issued 19 February 2003
Resolved
Provide watertight engine room hatches IAW 46 CFR 179.115 & 46 CFR179.360. LEGACY COMPONENT DESC: Machinery Space Opening
Communications › Radio Communications
Issued 19 February 2003
Resolved
Prove operation of SSB/MF radio by proper radio check IAW 46 CFR 184.502 & 47 CFR 80.905. LEGACY COMPONENT DESC: VFH Radiotelephone
Lifesaving › Lifejacket/PFD (General)
Issued 19 February 2003
Resolved
Provide as new water lights for 2 adult PFDs. LEGACY COMPONENT DESC: Lights
Lifesaving › Lifejacket/PFD (General)
Issued 19 February 2003
Resolved
Replace as new 1 waterlight for 1 adult PFD. LEGACY COMPONENT DESC: Lights
Lifesaving › Lifejacket/PFD (General)
Issued 19 February 2003
Resolved
Provide as new non-expired batteries for 3 child PFDs and 38 adult PFDs IAW 46 CFR 199.190. LEGACY COMPONENT DESC: Lights
Lifesaving › Lifebuoys
Issued 19 February 2003
Resolved
Replace as new non-expired battery for lifebuoy/ring bouy waterlight. LEGACY COMPONENT DESC: Water light
Electrical › Electrical Distribution System (service) › Wiring
Issued 5 February 2002
Resolved
Wire runs in the main hold and lazerette were found sagging do to broken or missing cable clamps.
Engineering › Bilge Water Management System
Issued 22 January 2002
Resolved
Repair and prove proper operation of fixed bilge pump. IAW 46 CFR 182.520. LEGACY COMPONENT DESC: Pump
Lifesaving › Lifebuoys
Issued 22 January 2002
Resolved
Provide additional retroreflective tape for ring buoy, IAW 46 CFR 185.604 (i)
Navigation › Piloting/Steering › Magnetic Compass
Issued 22 January 2002
Resolved
Inoperative compass light.
Fire Fighting
Issued 8 February 2001
Resolved
PRIOR TO CARRIAGE OF PASSANGERS, PROVIDE PROOF OF SERVICING ON ENGINE ROOM FIXED FIRE EXTINGUISHING SYSTEM. THIS ITEM TO BE CORRECTED NOT LATER THAN _x001C_8-MAR-01.
Lifesaving
Issued 8 February 2001
Resolved
WATER LIGHT LANYARD ON LIFE FLOAT DETERIORATED.
Fire Fighting
Issued 8 February 2001
Resolved
ENGINE ROOM FIXED FIRE SYSTEM DISCHARGED.
Documentation
Issued 30 December 1999
Resolved
AFTER 31DEC99, VESSEL MUST UNDERGO A SATISFACTORY DRYDOCK INSPECTION PRIOR TO CARRIAGE OF PASSENGERS.
Engineering
Issued 16 February 1996
Resolved
PROVIDE DOCUMENTATION THAT NEW FLEXIBLE FUEL HOSES MEET STANDARDS OF 46 CFR182.20-40(a)(2)(ii).
Navigation
Issued 16 February 1996
Resolved
PROVE PROPER OPERATION OF SINGLE SIDE BAND RADIO. THE VESSEL IS RESTRICTED TO THE LIMITED COASTWISE ROUTE ON THE CERTIFICATED OF INSPECTION UNTIL THISREQUIREMENT IS MET.
Electrical
Issued 18 August 1994
Resolved
REMOVE DEAD END WIRES OR PROPERLY INSULATE ENDS IN ENGINE ROOM AND MSD SPACES. REMOVAL PREFERRED._x001C_
Electrical
Issued 18 August 1994
Resolved
SUPPLY COVER FOR WIRE JUNCTION ABOVE "RULE" SWITCH IN ENG ROOM, (MID COMPARTMENT).
Documentation
Issued 4 December 1992
Resolved
PROVIDE PROOF OF APPROVED DRUG TESTING PROGRAM.
Fire Fighting
Issued 4 December 1992
Resolved
PROVIDE PROOF OF SERVICING OF PORTABLE FIRE EXTINGUISHERS.
Engineering
Issued 4 December 1992
Resolved
PROVE PROPER OPERATION OF STBD ENGINE. (STARTER IS OOC)
Lifesaving
Issued 4 December 1992
Resolved
CONDUCT UNDERWAY TESTS AND MAN OVERBOARD DRILLS.
Construction/Loadline
Issued 4 December 1992
Resolved
PROVE PROPER OPERATION OF ENGINE DRIVEN BILGE PUMP. (STBD ENG)
Navigation
Issued 4 December 1992
Resolved
PROVIDE DEVIATION CARD FOR MAGNETIC COMPASS
Lifesaving
Issued 6 November 1992
Resolved
PROPERLY MOUNT EPIRB ON OUTSIDE OF HOUSE.
Construction/Loadline
Issued 6 November 1992
Resolved
CLEAN & TREAT FURRING ON BOTTOM TRANSVERSE FRAME IN WAY OF ENGINE ROOM.
Accommodation/Occupational Safety
Issued 6 November 1992
Resolved
PROVIDE LOCK FOR FORWARD MSD OVERBOARD DISCHARGE. (STBD SIDE)
Accommodation/Occupational Safety
Issued 6 November 1992
Resolved
REMOVE HANDLE ON THROUGH HULL SEA VALVE FOR AFT MSD, SECURED CLOSED AND LABEL NO OVERBOARD DISCHARGE. (PORT SIDE)
Unknown
Issued 17 January 1992
Resolved
PROVIDE PROOF OF CURRENT RANDOM DRUG TESTING PROGRAOM FROM APPROVED FACILITY.
Unknown
Issued 17 January 1992
Resolved
PROVIDE LETTER DESIGNATION SENIOR DECK HAND(S).
Unknown
Issued 17 January 1992
Resolved
PROVIDE CURRENT COMPASS DEVATION CARD.
Electrical
Issued 17 January 1992
Resolved
SECURED AND REPAIR AUTO PILOT WIRING IN LAZARETTE
Navigation
Issued 17 January 1992
Resolved
SECURE COPPER TUBING ON FORWARD BULK HEAD IN LAZARETTE.
Electrical
Issued 17 January 1992
Resolved
PROVIDE COVER FOR LIGHT FIXTURE IN ENGINE ROOM PORT ENGINE AJACENT TO SIDE SHELL.
Accommodation/Occupational Safety
Issued 17 January 1992
Resolved
STENCIL EMERGENCY ESCAPE HATCH "EMERGANCY ESCAPE HATCH DO NOT BLOCK".
Unknown
Issued 19 June 1990
Resolved
PRIOR TO CARRYING PASSENGERS FOR HIRE COMPLETE SATISFACTORY TEST OF THE MAIN ENGINES AND BILGE PUMPS AND SUBMIT THE PROVIDED LETTER TO THE OFFICER IN CHARGE MARINE INSPECTION PORTLAND, OREGON.
Navigation
Issued 14 July 1989
Resolved
CONDUCT A SATISFACTORY TEST OF THE RADAR AND FATHOMETER WITH A MARINE INSPECTOR PRESENT.
Lifesaving
Issued 14 July 1989
Resolved
REPAIR CRACKS AND HOLES ON THE 15-PERSON LIFEFLOAT. THE VESSEL IS RESTRICTED TO A COASTWISE ROUTE AND MAY ONLY CARRY 26 PERSONS UNTIL THIS IS SATISFACTORILY COMPLETED.
Engineering
Issued 14 July 1989
Resolved
CONDUCT A SATISFACTORY TEST OF THE MAIN ENGINES, GENERATOR, AND ICE BILGE PUMP WITH A MARINE INSPECTOR PRESENT.
Electrical
Issued 2 May 1988
Resolved
SUBMIT ELECTRICAL DRAWING FOR APPROVAL OF INSTALLATION OF 4 KW GENERATOR INCLUDING TYPE WIRE AND SIZE, BREAKERS, LENGTH OF RUNS - AMPS OF EQUIPMENT ON CIRCUIT ETC.
Engineering
Issued 2 July 1987
Resolved
INSTALL CHECK VALVE ON AUTOMATIC BILGE PUMP LINE.
Accommodation/Occupational Safety
Issued 2 July 1987
Resolved
PROPERLY PLUMB HEAD TO THE MSD CONNECTION.
Fire Fighting
Issued 2 July 1987
Resolved
PROVIDE ADDITIONAL B-I FIRE EXTINGUISHER FOR AFT CONTROL STATION.
Fire Fighting
Issued 2 July 1987
Resolved
PROVIDE ADDITIONAL B-II FIRE EXTINGUISHER FOR GALLEY.
Unknown
Issued 28 November 1986
Resolved
REPLACE 2 CRACKED WINDOWS IN PILOTHOUSE AND 1 ION MAIN CABIN.
Accommodation/Occupational Safety
Issued 9 January 1986
Resolved
CONNECT TOILET TO MSD HOLDING TANK.
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.