SANCTUARY

SANCTUARY is a 1977 passenger vessel (inspected). The Coast Guard has recorded 82 inspections since 1985, most recently in March 2025, along with 179 deficiencies and 2 operational controls.

Records from 1985 to 2025. Most recent: inspection, 25 March 2025.

Built
1977
Last inspected
25 March 2025
Documentation
Expired · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDN9329
Flag
UNITED STATES
368325970
Maury page id
psix-49330

Inspections, by type

…with no type recorded8
Years with a record 37 calendar years (1985–2025)
The 82 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)41.2 ft × 14.2 ft × 6.3 ft
Registered tonnagegross 27 / net 18
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
Builderbuilder not recorded · SEATTLE, WA, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portMOSS LANDING, CA
Trade endorsementsCoastwise, unrestricted, Fishery
DocumentationExpired · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it27 - Regulatory (Subpart C or D), Gross Ton
18 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDN9329MMSI 368325970 · active · compulsorily equipped · granted 22 July 2023, expires 22 July 2033
WDF6190MMSI 367471590 · expired · compulsorily equipped · granted 16 November 2010, cancelled 16 January 2021
WDD9595MMSI 367313540 · expired · compulsorily equipped · granted 15 September 2007, cancelled 18 November 2017
WYE7081MMSI not assigned · expired · compulsorily equipped · granted 1 December 1994, cancelled 16 October 2004 · licensed under a name not among this hull’s recorded names (not shown)
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 82

25 March 2025 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8098988
13 March 2025 Internal Structural Exam · Drydock Exam · Hull Examination · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8089954
29 January 2024 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7848456
19 April 2023 Drydock Exam · Deficiency Check · Hull Examination · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7671983
4 April 2023 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7663148
5 April 2022 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7424655
16 September 2021 Administrative Inspection · Deficiency Check · Hull Examination · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7313605
10 February 2021 Deficiency Check · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7138807
8 July 2020 Simplified Stability Test · Plan Review "T" Boat
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7001230
28 February 2020 Deficiency Check · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6918946
28 February 2020 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6919031
9 December 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6872310
16 May 2019 Internal Structural Exam · Drydock Exam · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6685233
16 January 2019 Administrative Inspection · COI Inspection · DAPI Audit
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6610853
26 November 2018 Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6586896
20 December 2017 Administrative Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6327295
21 November 2017 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6307159
3 May 2017 Administrative Inspection · Internal Structural Exam · Drydock Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6137416
7 November 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6038874
9 November 2015 Internal Structural Exam · DAPI Audit · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5759120
19 March 2014 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4819293
14 March 2014 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4816206
7 February 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4239524
18 November 2010 Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3892373
19 January 2010 Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3665986
1 December 2008 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3374016
17 June 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3240939
25 October 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3086090
2 April 2007 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2900163
25 October 2006 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2801921
14 December 2005 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2546858
13 April 2005 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2333401
23 February 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2278760
15 December 2004 Administrative Inspection
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2259853
7 December 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2254898
1 December 2004 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2233990
23 October 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1934712
4 March 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1741337
19 November 2002 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1708382
27 December 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1486821
12 December 2001 Re-Inspection · Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1480383
8 February 2000 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1413669
6 August 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1110555
9 April 1999 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1125696
7 April 1999 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 787205
24 February 1999 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 797466
16 February 1999 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 794042
11 February 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 805270
16 December 1997 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1375206
13 January 1997 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1454392
16 December 1996 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1452241
4 November 1996 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1168160
30 January 1996 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1193076
10 January 1996 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 879044
17 January 1995 Deficiency Check · Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1178909
13 January 1995 Deficiency Check · COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1175096
15 February 1994 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1163795
24 February 1993 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1147845
25 January 1993 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 827384
28 December 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1140744
7 December 1992 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 828500
1 April 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1267317
3 March 1992 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 962742
10 February 1992 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1315664
18 April 1991 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1227211
25 March 1991 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1305491
7 March 1991 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1213244
1 March 1991 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 928060
14 March 1990 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1229797
2 March 1990 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 916130
2 February 1990 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1213817
7 March 1989 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 894608
2 February 1989 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1210778
4 May 1988 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1345269
12 April 1988 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1031558
9 April 1987 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1334380
13 January 1987 Administrative
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1314398
5 January 1987 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1313034
8 April 1986 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 987402
6 December 1985 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 988599
23 October 1985 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1302220
16 January 1985 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1288575

Deficiency record · 179

01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 25 March 2025 Resolved
A proper certificate issued by the Federal Communications Commission shall be regarded as evidence that the radio installation, if any, is in compliance with the requirements of that agency. Observed that the FCC Communications Safety Radio Telephony Certificate was expired. Replace the expired certificate with a valid certificate. (46 CFR 184.25-1(b)) [OLD T]
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 15 April 2025
Resolution: Received photos of new FCC Communications Safety Radio Telephony Certificate.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 March 2025 Resolved
Each life float shall be fitted with a life line and shall be equipped with two paddles, a water light and a painter. Observed one of the aft life floats is missing a floating water light and one of the forward floating water light brackets is broken. Affix a floating water light to the life float and repair the broken bracket. (46 CFR 180.15-1(a)) [OLD T]
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 25 March 2025
Resolution: Received photos of satisfactory repairs for the water light and bracket.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 March 2025 Resolved
At least one ring life buoy must be fitted with a lifeline. Each ring life buoy with a floating waterlight must have a lanyard of at least 3 feet in length, but not more than 6 feet, securing the waterlight around the body of the ring life buoy. Each floating waterlight installed after March 11, 1997, on a vessel carrying only one ring buoy, must be attached to the lanyard with a corrosion-resistant clip. Observed ring life buoy waterlight was not secured around body with a clip, and the lifeline was not in serviceable condition. Secure the waterlight around the body with a clip and replace the lifeline with serviceable replacement. (46 CFR 180.70)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 25 March 2025
Resolution: Received satisfactory photos of replaced lifeline and clip for the water light.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 25 March 2025 Resolved
All vessels must have navigation lights in compliance with the applicable sections of the International and Inland Navigation Rules. Observed masthead light and stern light both show incorrect arcs. Replace lights to properly display arcs of lumination. (46 CFR 183.420)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 15 April 2025
Resolution: Received satisfactory photo of newly installed masthead light.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 25 March 2025 Resolved
Waste receptacles must be constructed of noncombustible materials with no openings in the sides or bottom. Observed waste receptacles made from plastic or similar materials. Replace bins with noncombustible material. (46 CFR 177.405(f))
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 8 April 2025
Resolved 15 April 2025
Resolution: Received photo of a non-combustible waste receptacle replacement.
02 - Structural Conditions › N/A - No Subsystem › Wheelhouse -door -window
Issued 25 March 2025 Resolved
Each window, port hole, and its means of attachment to the hull or deck house, must be capable of withstanding the maximum load from wave and wind conditions expected due to its location on the vessel and the authorized route of the vessel. Observed that the central rear window of the bridge was cracked. Repair cracked window. (46 CFR 177.1020)
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Resolved 22 July 2025
Resolution: Received satisfactory photo of repaired window.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 13 March 2025 Resolved
The COI and any SOLAS Certificates must be posted under glass or other suitable transparent material, such that all pages are visible. Current COI was not present onboard. 46 CFR 176.302
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 March 2025
Resolution: MI delivered new original COI to operator.
02 - Structural Conditions › N/A - No Subsystem › Closing devices/watertight doors
Issued 13 March 2025 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections... of all watertight closures in the hull, decks, and bulkheads. MI observed foscle void space hatchcover leaking from the deck. 46 CFR 176.802 (a)(2)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 25 March 2025
Resolution: MI attended vessel to verify repairs.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 29 January 2024 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull, protection against fire, means of escape in case of a sudden unexpected casualty, guards and rails in hazardous places, ventilation of enclosed spaces, and necessary facilities for passengers and crew. Capped thru hull penetration in mid ship void just aft of forward bulkhead/port of centerline has excess corrosion where the piping penetrates the hull that could subject the vessel to flooding if it further corrodes. Replace thru hull piping/cap to the satisfaction of attending Marine Inspector.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 1 February 2024
Resolution: Thru hull removed and covered with FRP.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 29 January 2024 Resolved
Exhaust gas must not leak from the piping or any connections. Exhaust leak detected on the starboard engine.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 14 March 2024
Resolution: Vessel rep identified loose exhaust coupler bolt coming off the turbo and tightened. Removed and reinstalled crankcase ventialation system. Verified engine no longer leaking exhuast.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 29 January 2024 Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards, including fire, caused by or originating in electrical equipment, and electrical shock. Dead end wires present in forward lower cabin, starboard side near aft bulkhead.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 1 February 2024
Resolution: Verified wires capped.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 January 2024 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: Charts of large enough scale to make safe navigation possible. Charts onboard were not up to date.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 February 2024
Resolved 14 March 2024
Resolution: Verified updated charts onboard.
09 - Working and Living Conditions › 091 - Living Conditions › Sanitary Facilities
Issued 29 January 2024 Resolved
At each inspection for certification, quarters, toilet and washing spaces…and similar spaces maybe be examined to determine that they are in serviceable and in a sanitary condition. Sink line running along the overhead of the midship void was previously terminated but is still allowing small leak (approx.. 1 drop every 3 seconds). Make permanent repairs at next credit drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 30 April 2025
Resolved 13 March 2025
Resolution: MI verified repair to sink drain; operator replaced drainage piping throughout system.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Scuppers, inlets and discharges
Issued 19 April 2023 Resolved
Water tight coming that comply with the requirements of Table 171.124 (Partially Protected – 6 inches) must be provided for each opening …that...gives access into the hull. Vessel has an pipe fitting on the starboard aft bulkhead of the cabin that allows water to ingress below the main deck and is located below 6 inches above the deck. 46 CFR 171.124(e)(1) “OLD T”. 705 - Prior to credit drydock.
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 12 May 2023
Resolution: Operator sent photos clearing deficiency.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 4 April 2023 Resolved
For fixed-gas fire extinguishing systems, the inspections and tests required by Table 176.810(b) of this section, in addition to the tests required by 46 CFR 147.60 and 147.65. The owner or managing operator must provide satisfactory evidence of the required servicing to the marine inspector. Fireboy service records must be provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 24 April 2023
Resolution: Received satisfactory fire service record.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 April 2023 Resolved
A vessel must comply with the applicable requirements for any radio...including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission. Station license is missing and must be provided.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 28 July 2023
Resolution: Received satisfactory photograph of station license.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 4 April 2023 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date: (3) Coast Guard Light List; (4) Tide Tables. Publications are out of date and must be replaced with up-to-date volumes either in hard copy or electronic format.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 24 April 2023
Resolution: Received satisfactory photographs of Light List and Tide Tables.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 4 April 2023 Resolved
Each ring life buoy on a vessel must: be approved in accordance with § 160.050 in subchapter Q of this chapter. The grab line shall be 3/8-inch diameter polyethylene, polypropylene, or other suitable buoyant type synthetic material having a minimum breaking strength of 1,350 pounds. Grab line is deteriorated and must be replaced to the specified minimum breaking strength.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 24 April 2023
Resolution: Received satisfactory photograph of ring buoy.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 4 April 2023 Resolved
Each flare carried to meet this section must be stowed in one of the following: a portable watertight container marked as required by § 185.614 of this chapter, carried at the operating station. Portable watertight container of sufficient size must be provided for flares.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2023
Resolved 24 April 2023
Resolution: Received satisfactory photograph of watertight flare container.
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 5 April 2022 Resolved
Each item of survival craft equipment must be of good quality, and efficient for the purpose it is intended to serve. Light attached to life float is extinguished/does not actuate as designed. 8 passengers are reduced from total persons until light on life float is in working condition.
Action required: 705 - Other - as specified
Resolved 11 April 2022
Resolution: Replaced inoperable light to satisfaction of MI.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 16 September 2021 Resolved
A vessel exposed to salt water more than three months in any 12 month period must undergo a dry dock and internal structural examination at least once every two years. Vessel has failed to schedule dry dock and internal structural examination within two years of last dry dock as listed on the COI.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 16 September 2021
Resolved 27 September 2021
Resolution: Satisfactorily completed credit dry dock exam.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Covers (hatchway-, portable-, tarpaulins, etc.)
Issued 10 February 2021 Resolved
A hatch exposed to the weather must be watertight. Lazarette hatch not watertight. Verify hatch is watertight in presence of Marine Inspector on March 9th, 2021.
Condition: Invalid
Action required: 705 - Other - as specified
Due 9 March 2021
Resolved 16 February 2021
Resolution: Conducted visual examination of hatch and sealing surfaces. Verified watertight integrity by sealing the hatch and spraying it with water. The hatch is now watertight - [name withheld]
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 10 February 2021 Resolved
Each life float must be fitted with two paddles that are lashed to the life float and must be marked with the name of the vessel. Not all life float paddles are connected to each float or labeled with vessel name. 01 paddle not in operational condition. Correct stowage of all paddles and replace 01 broken paddle.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2021
Resolved 2 March 2021
Resolution: Operator replaced broken paddle, labeled all paddles, and lashed to life floats
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 10 February 2021 Resolved
A vessel not required to have a power driven fire pump must have three 2.5 gallon buckets. Vessel has onboard 2 gallon buckets.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2021
Resolved 2 March 2021
Resolution: Operator purchased new 2.5 gal buckets with proper labeling and laynard lengths
11 - Life Saving Appliances › N/A - No Subsystem › Rigid liferafts
Issued 10 February 2021 Resolved
When stowed in tiers, life floats must be kept apart by spacers. No spacers between life floats.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2021
Resolved 2 March 2021
Resolution: Operator installed wooden spacers between life floats
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 10 February 2021 Resolved
Electrical equipment must be installed to protect passengers and crew from electrical hazards. Exposed dead end wires in accommodation space fire extinguisher cubby. Remove or cap wires.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 February 2021
Resolved 2 March 2021
Resolution: Operator removed dead end wires
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 10 February 2021 Resolved
The general construction of the vessel must be such as to minimize fire hazards. Wall between engine room and midships compartment provides a vapor tight boundary for Fire Boy to effectively put out engine room fire. MI witnessed penetration in bulkhead that was not made vapor tight.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 25 February 2021
Resolved 11 February 2021
Resolution: Operator used fire stop to create vapor tight penetration.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 February 2021 Resolved
Each ring life buoy must be marked with retro-reflective material. No retro-reflective tape on ring buoy.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 11 February 2021
Resolved 11 February 2021
Resolution: Operator installed retro-reflective tape on buoy in presence of MI.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 28 February 2020 Resolved
Propulsion machinery must be suitable in type and design for propulsion requirements of the hull in which it is installed and capable of operating at constant marine load under such requirements without exceeding its designed limitations. On February 28th, vessel reported a loss of power/propulsion by possible clogged fuel filter or battery/alternator discrepancy. 46 CFR 182.200
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 2 March 2020
Resolved 6 March 2020
Resolution: Operator provided tech report and statement of successful sea trials.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 9 December 2019 Resolved
The inspection and maintenance of survival craft shall be logged for review by Coast Guard upon request. The vessel did not have an up-to-date life saving inspection log. The vessel updated the life saving inspection log in the presence of the Marine Inspector. 46 CFR 185.702 (d)
Action required: 10 - Deficiency Rectified
Due 9 December 2019
Resolved 9 December 2019
Resolution: Life saving inspection log updated in the presence of the Marine Inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › USCG Certificate of Documentation (COD)
Issued 26 November 2018 Resolved
Any vessel of at least 5 net tons which engages in coastwise trade must have a Certificate of Documentation bearing a valid endorsement.
Condition: Invalid
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 January 2019
Resolution: Activity #6610853 confirmed valid vessel documentation.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 26 November 2018 Resolved
The owner, charterer, master or managing operator shall instruct each crew memeber as to the duties the crewmember is expected to perform in an emergency. Vessel could not provide proof of any training or drills conducted.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 17 January 2019
Resolution: Activity #6610853 confirmed valid vessel documentation.
Operations/Management › Drug and Alcohol Testing › EAP Display Requirements
Issued 21 November 2017 Resolved
Vessel requires EAP policy statement and hotline number IAW 46 CFR 16.401.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 20 December 2017
Resolution: Operator provided photographic evidence of the corrective action.
Lifesaving › Lifefloat › Serviceable
Issued 21 November 2017 Resolved
10-person & 15-person lifefloats require repair or replacement; also, paddles require markings. - 46 CFR 180.200
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 20 December 2017
Resolution: Operator provided photographic evidence of the corrective action.
Lifesaving › Lifebuoys › Serviceable
Issued 21 November 2017 Resolved
Lifering worn/wasted on unmarked side and requires replacement IAW 46 CFR 180.70.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 21 December 2017
Resolved 20 December 2017
Resolution: Operator provided photographic evidence of the corrective action.
Construction/Loadline › Penetrations › Gasket
Issued 3 May 2017 Resolved
Gasket material around engine room hatch covers worn.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 June 2017
Resolved 19 June 2017
Resolution: Received photos for repaired gasket.
Fire Fighting › Ventilation Systems › Ducts
Issued 9 November 2015 Resolved
Repair, replace or submit plan for approval to remove Stb side MDE air duct.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 20 November 2015
Resolution: Starboard side MDE Natural vent air duct box custom fabricated and installed.
Communications › Radio Communications › EPIRB
Issued 9 November 2015 Resolved
Update the EPIRB registration to match the new call sign.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 November 2015
Resolved 20 November 2015
Resolution: EPIRB registered with correct call sign
Operations/Management › Equipment Service/Testing › EPIRB
Issued 19 March 2014 Resolved
EPIRB reisgration expired. Hydrostatic release uint on EPIB housing expired.
Condition: Invalid
Due 5 April 2014
Resolved 21 March 2014
Resolution: Proof of registration provided. New hydrostatic release unit installed.
Lifesaving › Lifebuoys › Serviceable
Issued 19 March 2014 Resolved
Replace 01 lifering bouy with new servicable lifering bouy
Condition: Improper/Lack of Maintenance
Due 29 March 2014
Resolved 21 March 2014
Resolution: New lifering bouy placed in service on the vessel.
Documentation › Logs/Records › Logbook/Record (unofficial)
Issued 19 March 2014 Resolved
Provide log for maintenance of lifesaving equipment.
Due 5 April 2014
Resolved 29 March 2014
Resolution: Lifesaving equipment maintenance log provided.
Communications › Alarms/Indicators › High Water Alarm
Issued 19 March 2014 Resolved
Prove proper operation of high level alarm in laz.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 29 March 2014
Resolved 21 March 2014
Resolution: Visual and audible alarm operational for high level alarm in laz.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 14 March 2014 Resolved
Do not operate vessel with passengers onboard until Annual Inspection has been conducted to the satisfaction of the attending USCG Marine Inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Due 14 March 2014
Resolved 21 March 2014
Resolution: Annual inspection completed.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 7 February 2012 Resolved
Provide the current original Certificate of Documentation onboard the vessel.
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 7 March 2012
Resolution: The vessel''s original COD is onboard and properly posted.
Communications › Radio Communications › EPIRB
Issued 7 February 2012 Resolved
Provide a monthly EPIRB log to the attending Marine Inspector.
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 7 March 2012
Resolution: monthly EPIRB log commenced and maintained.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 7 February 2012 Resolved
Supply ammonia inhalants and tourniquet to the first aid kit.
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 7 March 2012
Resolution: The proper supplies were added to the kit and verified.
Engineering › Bilge Water Management System › Hose
Issued 7 February 2012 Resolved
Install double hose clamps on bilge discharge flex hose.
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 7 March 2012
Resolution: Installed a second hose clamp on the discharge hose.
Documentation › Markings/Placards › Lifejacket Placard
Issued 7 February 2012 Resolved
Post life jacket placards w/corresponding types in all stowage location.
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 7 March 2012
Engineering › Bilge Water Management System › Strainer
Issued 7 February 2012 Resolved
Install bilge suction strainer of the appropriate size.
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 14 March 2012
Resolution: The proper suction strainer was installed.
Documentation › Certificates/Documents › FCC Vessel Bridge-to-Bridge Radiotelephony Cert.
Issued 7 February 2012 Resolved
Provide current FCC saftey radio telephone certificate.
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 7 March 2012
Resolution: The current certificate is now onboard.
Documentation › Certificates/Documents › FCC SSL
Issued 7 February 2012 Resolved
Provide proof of Marine Radio Operators license.
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 7 March 2012
Fire Fighting › Fire Bucket › Quantity
Issued 7 February 2012 Resolved
Provide the required fire buckets properly marked w/lanyard.
Condition: Placed in Improper Service
Action required: 705 - Other - as specified
Due 7 March 2012
Resolved 7 March 2012
Resolution: Fire buckets onboard.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Remote Pulls
Issued 18 November 2010 Resolved
Replace wasted E/R fixed fire extinguishing manual release cable prior to taking passengers. This requirement was amended to allow operation until 12/01/2010.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 December 2010
Resolved 22 December 2010
Resolution: Wasted E/R fised fire extinguisher manual release cable was replaced.
Lifesaving › Buoyant Apparatus › Serviceable
Issued 18 November 2010 Resolved
Replace condemned 10 person buoyant apparatus with approved life float, prior to carrying more than 29 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 December 2010
Resolution: Bouyant apparatus was replaced with a 10 man life float.
Lifesaving › Lifefloat › Serviceable
Issued 18 November 2010 Resolved
fifteen person life float needs to be repaired in accordance with manufacturer's recommendations
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 31 January 2011
Resolved 22 December 2010
Resolution: The fifteen man liferaft was repaired in accordance with manufacturers recomendations.
Lifesaving › Lifejacket/PFD (General) › Condition
Issued 18 November 2010 Resolved
two life jackets were found to be wasted and need to be replaced prior to carrying more than 37 passengers.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 22 December 2010
Resolution: Two life jackets were replaced and stored onboard the vessel
Communications › Radio Communications › EPIRB
Issued 18 November 2010 Resolved
EPIRB antenna is loose upon inspection. Provide a technician report attesting to the proper operation of the vessel's EPIRB prior to conducting operations outside of 3 nm from shore.
Action required: 705 - Other - as specified
Resolved 22 December 2010
Resolution: Technician report was reviewed and antenna was replaced an EPIRB. EPIRB found to be in an operational status.
Operations/Management › Drills/Instruction › Not Conducted
Issued 18 November 2010 Resolved
Conduct underway operational test including drills and testing of bridge equipment.
Action required: 705 - Other - as specified
Due 18 December 2010
Resolved 22 December 2010
Resolution: Underway operational tests along with fire and man overboard drills were conducted and all found satisfactory.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 18 November 2010 Resolved
Privide a complete first aid kit in accordance with the table found in 46 CFR 160.041(b)
Action required: 705 - Other - as specified
Due 18 December 2010
Resolved 22 December 2010
Resolution: First Aid kit was found to be in accordance with table found in 46 CFR 160.041(b).
Stability › Watertight Integrity › General
Issued 1 December 2008 Resolved
Complete credit dry dock exam.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 May 2009
Resolution: Completed Hull Exam.
Stability › Unintentional Flooding › General
Issued 25 October 2007 Resolved
Properly cap off thru hull valve from removed sewage overboard line.
Action required: 705 - Other - as specified
Resolved 25 October 2007
Lifesaving › Lifefloat › Float Free
Issued 25 October 2007 Resolved
Make lifefloats float free in way of tangled lines.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 25 October 2007
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 25 October 2006 Resolved
Provide proper operation of One Adult Type I PFD light.
Due 1 November 2006
Resolved 25 October 2006
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 25 October 2006 Resolved
Provide proper operation of One Child Type I PFD light.
Due 1 November 2006
Resolved 25 October 2006
Resolution: Corrected on the spot.
Electrical › Lighting (service) › Lighting Fixture
Issued 25 October 2006 Resolved
Provide lens cover for overhead light in lower forward compartment.
Due 1 November 2006
Resolved 25 October 2006
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2006 Resolved
Secure bare wiring under pilot house console.
Due 1 November 2006
Resolved 25 October 2006
Resolution: Corrected on the spot.
Electrical › Electrical Distribution System (service) › Wiring
Issued 25 October 2006 Resolved
Secure bare wiring in passenger compartment void.
Due 1 November 2006
Resolved 25 October 2006
Resolution: Corrected on the spot.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 25 October 2006 Resolved
Provide proper operation of anchor light.
Due 1 November 2006
Resolved 25 October 2006
Resolution: Corrected on the spot.
Engineering › Diesel Engine (propulsion-reduction gear) › Block
Issued 25 October 2006 Resolved
Tighten loose drive belts on stbd engine.
Condition: Improper/Lack of Maintenance
Due 1 November 2006
Resolved 26 October 2006
Resolution: Corrected.
Electrical › Electrical Distribution System (service) › Wiring
Issued 14 December 2005 Resolved
Dead end exposed wiring in way of distribution panel and bridge wiring run.
Action required: 705 - Other - as specified
Due 14 December 2005
Resolved 15 December 2005
Resolution: Corrected on the spot.
Lifesaving › Lifejacket/PFD (General) › Retroreflective Material
Issued 14 December 2005 Resolved
Replace or renew retroreflective material on one adult lifejacket.
Action required: 705 - Other - as specified
Due 14 December 2005
Resolved 14 December 2005
Resolution: Corrected on the spot.
Documentation › Certificates/Documents › Certificate of Documentation (CG-1270)
Issued 23 February 2005 Resolved
Provide proper proof of current Certificate of Documentation.
Due 6 April 2005
Resolved 12 April 2005
Documentation › Certificates/Documents › FCC SSL
Issued 23 February 2005 Resolved
Provide proof of current FCC Marine Radio Operator Permit.
Due 23 March 2005
Resolved 18 April 2005
Documentation › Certificates/Documents › FCC SSL
Issued 23 February 2005 Resolved
Provide proof of current Communication Act Safety Radiotelephony certificate.
Due 23 March 2005
Resolved 18 April 2005
Construction/Loadline › Structures › Superstructure
Issued 23 February 2005 Resolved
Renew broken bridge window.
Due 23 March 2005
Resolved 18 April 2005
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 February 2005 Resolved
Renew 1 Adult PFD. Vessel is restricted to carry a maximum of 38 Adult passengers.
Due 23 March 2005
Resolved 21 April 2005
Electrical › Lighting (service) › Lighting Fixture
Issued 23 February 2005 Resolved
Remove light fixture above the starboard engine and proper dead end the conductor.
Due 23 March 2005
Resolved 18 April 2005
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 23 February 2005 Resolved
Install machinery guards on both main diesel engines.
Due 6 April 2005
Resolved 12 April 2005
Documentation › Manuals/Policy Documentation › Vessel Specific Watch Policy/Procedures
Issued 23 February 2005 Resolved
Provide proof of senior deckhand letter IAW NVIC 1-91.
Due 23 March 2005
Resolved 18 April 2005
Lifesaving › Lifebuoys › Markings (ship name/port)
Issued 23 February 2005 Resolved
Renew ship's name on ring buoy.
Due 23 March 2005
Resolved 23 February 2005
Lifesaving › Lifejacket/PFD (Type I) › Condition
Issued 23 February 2005 Resolved
Remove worn child PFD from the vessel.
Due 23 March 2005
Resolved 23 February 2005
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 23 February 2005 Resolved
Properly label child PFD storage.
Due 23 March 2005
Resolved 23 February 2005
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 23 February 2005 Resolved
Renew 1 Adult PFD light.
Due 23 March 2005
Resolved 23 February 2005
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 February 2005 Resolved
Prove proper operation of the starboard running light.
Due 23 March 2005
Resolved 23 February 2005
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 23 February 2005 Resolved
Remove expired medical supplies from the vessel.
Due 23 March 2005
Resolved 23 February 2005
Engineering › Steering Gear System › Linkage
Issued 23 February 2005 Resolved
Properly secure and align the steering linkages in accordance with manufacture specifications.
Due 23 March 2005
Resolved 18 April 2005
Stability › Watertight Integrity › General
Issued 15 December 2004 Resolved
Properly install stop valves to all through hull penatrations within 6 inches above the load waterline IAW 46CFR 178.40-1(d) and 46CFR 178.840-1(e).
Action required: 705 - Other - as specified
Due 15 February 2005
Resolved 23 February 2005
Fire Fighting › Fixed CO2 Fire Extinguishing System › Servicing
Issued 10 December 2004 Resolved
Provide proof of annual servicing of all portable and fixed fire fighting extinguishers IAW 46 CFR 176.810
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 13 December 2004
Resolution: Service completed by Tri-County Fire Protection, INC. Receipt Faxed in.
Electrical › Electric Supply System (service) › Cable
Issued 1 December 2004 Resolved
Properly dead-end all exposed wiring under console in pilothouse and under main cabin sink on starboard side IAW 46CFR183.210.
Due 1 January 2005
Resolved 10 December 2004
Construction/Loadline › Penetrations › Gasket
Issued 1 December 2004 Resolved
Make all penetrations in engine room bulkhead watertight IAW 46CFR179.212.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 January 2005
Resolved 3 December 2004
Resolution: Owner/Operator provided digital photographs and written attestation.
Engineering › Steering Gear System › Piping
Issued 1 December 2004 Resolved
Install supports to properly secure hydraulic piping for steering in lazarette.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 January 2005
Resolved 3 December 2004
Resolution: Owner/Operator provided digital pictures and written attestation that the deficiency was corrected.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 1 December 2004 Resolved
Remove and arrest areas of furring located in aft portion of engine room.
Action required: 705 - Other - as specified
Due 10 January 2005
Resolved 10 December 2004
Construction/Loadline › Penetrations › Flange Pad
Issued 1 December 2004 Resolved
Renew backing board on starboard thru hull fitting on starboard aft section of engine room.
Action required: 17 - Rectify deficiencies prior to departure
Due 1 January 2005
Resolved 3 December 2004
Resolution: Owner/Operator provided digital pictures and written attestation that the deficiency was corrected.
Lifesaving › Lifejacket/PFD (General) › Lights
Issued 23 October 2003 Resolved
Replace expired life jacket lights.
Action required: 705 - Other - as specified
Due 1 December 2003
Resolved 1 December 2003
Pollution Prevention/Response › Prevention Equipment › Sewage System Piping
Issued 23 October 2003 Resolved
Tighten hose connection on toilet raw water supply hose.
Action required: 705 - Other - as specified
Due 1 December 2003
Resolved 1 December 2003
Lifesaving › Lifebuoys › Self-igniting Lights
Issued 4 March 2003 Resolved
Provide water light for buoyant apparatus IAW 46CFR 180.175 (d) in way of cabin top.
Condition: Unknown
Action required: 705 - Other - as specified
Due 4 March 2003
Resolved 4 March 2003
Engineering › Sea-water System (primary cooling)
Issued 19 November 2002 Resolved
Renew backing board on port engine thru hull fitting. LEGACY COMPONENT DESC: Piping
Action required: 705 - Other - as specified
Due 22 November 2002
Resolved 21 November 2002
Documentation
Issued 12 December 2001 Resolved
Correct Certificate of Document to include "Coastwise" endorsement.
Condition: Unknown
Due 12 January 2002
Resolved 5 January 2002
Accommodation/Occupational Safety
Issued 12 December 2001 Resolved
Update first aid kit
Condition: Improper/Lack of Maintenance
Due 12 January 2002
Resolved 5 January 2002
Lifesaving
Issued 12 December 2001 Resolved
Install lifeline on lifering buoy as required by 46 CFR 180.70(c)
Condition: Improper Installation
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''''''''d fax from master indicated this item was corrected.
Lifesaving › Lifejacket/PFD (Type I) › Storage
Issued 12 December 2001 Resolved
Stow child PFD's seperately from adult PFD's and label correctly
Condition: Improper Installation
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''d fax from master indicating this item had been corrected.
Fire Fighting › Ventilation Systems › Duct Hatches
Issued 12 December 2001 Resolved
Install ventilation closure for vents servicing engineroom
Condition: Unknown
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''d fax from master indicating this item was corrected.
Construction/Loadline › Hull
Issued 12 December 2001 Resolved
Make collision bulkhead watertight as required by 46 CFR 179.210 & 179.212
Condition: Improper Installation
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''d fax from master indicating the bulkhead was now watertight.
Pollution Prevention/Response › Prevention Equipment
Issued 12 December 2001 Resolved
Install pollution placard in wheelhouse.
Condition: Unknown
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''d fax indicating this requirement was corrected.
Navigation › Piloting/Steering › Marine Charts
Issued 12 December 2001 Resolved
Update nautical charts with notice to mariners
Condition: Improper/Lack of Maintenance
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''d fax from master indicating this requirement had been corrected.
Navigation › Piloting/Steering
Issued 12 December 2001 Resolved
Have on board a current copy of the FCC regulations, coast pilot, and the lightlist. LEGACY COMPONENT DESC: US Coast Pilot
Condition: Unknown
Due 12 March 2002
Resolved 4 March 2003
Lifesaving › Buoyant Apparatus
Issued 12 December 2001 Resolved
Install correctly sized weaklink on lifefloats LEGACY COMPONENT DESC: weaklink
Condition: Improper Installation
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''d fax from master indicating this requirement had been corrected.
Lifesaving › Buoyant Apparatus
Issued 12 December 2001 Resolved
Install new painters on lifefloats LEGACY COMPONENT DESC: painter
Condition: Unknown
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''d fax from master indicating this requirement had been corrected.
Fire Fighting › Fixed Gas Fire Extinguishing System
Issued 12 December 2001 Resolved
Post fixed fire extinguishing system instructions as required by 46 CFR 185.612 LEGACY COMPONENT DESC: Instructions
Condition: Unknown
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''d fax from owner indicating that this requirement had been corrected.
Electrical › Electric Supply System (service) › Battery Installation
Issued 12 December 2001 Resolved
Clean battery connections on starting batteries
Condition: Unknown
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''d fax from master indicating that this requirement had been corrected.
Lifesaving
Issued 12 December 2001 Resolved
Renew hydrostatic release on 406 EPIRB LEGACY COMPONENT DESC: EPIRB Hydro Release
Condition: Unknown
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 January 2002
Resolved 5 January 2002
Resolution: Rcv''''d fax from master indicating that this requirement had been corrected.
Lifesaving
Issued 7 April 1999 Resolved
Replace or repair bilge high level alarm in lazarette and Engine Room.
Condition: Unknown
Due 9 April 1999
Resolved 14 April 1999
Lifesaving
Issued 16 December 1997 Resolved
RENEW RING BUOY PRIOR TO EMBARKING PASSENGERS.
Condition: Unknown
Due 18 December 1997
Resolved 18 December 1997
Construction/Loadline
Issued 10 January 1996 Resolved
PROPERLY LABEL EMERGENCY EXIT IN FORWARD CABIN.
Condition: Unknown
Due 10 February 1996
Resolved 30 January 1996
Electrical
Issued 10 January 1996 Resolved
REMOVE OR PROPERLY TERMINATE WIRING AFT OF HOLDING TANK IN SECOND COMPARTMENT AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 10 February 1996
Resolved 30 January 1996
Electrical
Issued 10 January 1996 Resolved
PROPERLY SUPPORT WIRING IN ENGINE ROOM AND SECOND COMPARTMENT AFT OF COLLISION BULKHEAD.
Condition: Unknown
Due 10 February 1996
Resolved 30 January 1996
Construction/Loadline
Issued 10 January 1996 Resolved
INSTALL CAPTURE DEVICES ON PORT AND STARBOARD ENGINE ROOM HATCHES.
Condition: Unknown
Due 10 February 1996
Resolved 30 January 1996
Construction/Loadline
Issued 10 January 1996 Resolved
REPLACE GASKET ON STARBOARD ENGINE ROOM HATCH.
Condition: Unknown
Due 10 February 1996
Resolved 30 January 1996
Electrical
Issued 10 January 1996 Resolved
PROPERLY TERMINATE OR REMOVE GHOST WIRING IN STARBOARD LAZARETTE.
Condition: Unknown
Due 10 February 1996
Resolved 30 January 1996
Electrical
Issued 10 January 1996 Resolved
REPLACE LIGHT FIXTURE COVER AND BULB ON STARBOARD SIDE OVERHEAD LIGHT IN SALON.
Condition: Unknown
Due 10 February 1996
Resolved 30 January 1996
Navigation
Issued 10 January 1996 Resolved
MODIFY/REPLACE MAST HEAD LIGHT TO COMPLY WITH RULE 22(b) OF COMDTINST M1667.2B (NAVIGATION RULES). VESSEL RESTRICTED TO DAYLIGHT OPERATION UNTILCORRECTED.
Condition: Unknown
Due 10 February 1996
Resolved 30 January 1996
Construction/Loadline
Issued 10 January 1996 Resolved
INSTALL CAPTURE DEVICE ON FOREPEAK ACCESS.
Condition: Unknown
Due 10 February 1996
Resolved 30 January 1996
Engineering
Issued 17 January 1995 Resolved
REPLACE CUTLASS BEARINGS FOR BOTH SHAFTS. SUBMIT PHOTOS & INVOICES, MAY BE CLEARED WHILE IN WATER.
Condition: Unknown
Due 31 January 1995
Resolved 8 February 1995
Engineering
Issued 17 January 1995 Resolved
SERVICE OR REPLACE BOTH PROPS. SUBMIT PHOTOS & SERVICING REPORT. MAY BE CLEARED WHILE IN WATER.
Condition: Unknown
Due 31 January 1995
Resolved 8 February 1995
Construction/Loadline
Issued 17 January 1995 Resolved
REPLACE COVER FOR EMERGENCY FUEL STOPS, STBD SIDE.
Condition: Unknown
Due 31 January 1995
Resolved 8 February 1995
Accommodation/Occupational Safety
Issued 17 January 1995 Resolved
REMOVE OLD JABSCO PUMP FOR MSD.
Condition: Unknown
Due 31 January 1995
Resolved 8 February 1995
Construction/Loadline
Issued 17 January 1995 Resolved
REPLACE CAPTIVE CHAIN ON HATCH FOR STEERING FLAT.
Condition: Unknown
Due 31 January 1995
Resolved 8 February 1995
Navigation
Issued 17 January 1995 Resolved
REPLACE BOTH RUDDER BEARINGS. PROVIDE INVOICE. MAY BE CLEARED WHILE VESSEL IS IN WATER.
Condition: Unknown
Due 31 January 1995
Resolved 8 February 1995
Lifesaving
Issued 17 January 1995 Resolved
MARK EMERGENCY FUEL STOPS - PROVIDE DIRECTIONAL ARROWS.
Condition: Unknown
Due 31 January 1995
Resolved 8 February 1995
Construction/Loadline
Issued 17 January 1995 Resolved
REPLACE 2" VALVE FOR MSD DISCHARGE. PROVIDE INVOICE.
Condition: Unknown
Due 31 January 1995
Resolved 8 February 1995
Accommodation/Occupational Safety
Issued 17 January 1995 Resolved
SECURE RAIL ON STBD SIDE FWD.
Condition: Unknown
Due 31 January 1995
Resolved 8 February 1995
Engineering
Issued 13 January 1995 Resolved
CONDUCT U/W TEST, PROPULSION AND STEERING (MAN OVERBOARD).
Condition: Unknown
Due 13 February 1995
Resolved 9 March 1995
Engineering
Issued 13 January 1995 Resolved
RESTENCIL FUEL SHUTOFFS AND DIRECTION ARROWS_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1995
Resolved 10 February 1995
Construction/Loadline
Issued 13 January 1995 Resolved
MAKE REPAIRS TO DECK UNDER #3 RAIL SUPPORT ON STBD SIDE_x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 13 February 1995
Resolved 10 February 1995
Lifesaving
Issued 15 February 1994 Resolved
PROVIDE (1) 15 PERSON LIFEFLOAT/BUOYANCY APPARATUS OR REPAIR EXISTING ONE IAW MANUFACTURER RECOMMENDATION & PROVIDE PROOF OF APPROVAL NUMBER.
Condition: Unknown
Due 15 March 1994
Resolved 9 March 1994
Fire Fighting
Issued 25 January 1993 Resolved
PROVIDE PROOF OF FIRE EXT SERVICING.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Accommodation/Occupational Safety
Issued 25 January 1993 Resolved
RE-SEAL DECK DRAIN IN HEAD.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Construction/Loadline
Issued 25 January 1993 Resolved
CLEAN & TREAT FURRIN IN ENGINE ROOM ON TRANSVERSE FRAMING.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Construction/Loadline
Issued 25 January 1993 Resolved
REPLACE RUSTED/LOOSE PIPE SUPPORT FOR MAD SHORE TIE OVERBOARD PIPING.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Fire Fighting
Issued 25 January 1993 Resolved
REPLACE HOSE FOR FIRE/BILGE PUMP.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Engineering
Issued 25 January 1993 Resolved
STENCIL BOTH EMERGENCY F/O SHUT-OFFS & SHOW DIRECTION OF OPERATION.
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Engineering
Issued 25 January 1993 Resolved
PROPERLY SECURE/FASTEN F/O SHUT-OFF REACH ROD TO VALVE HANDLE. (STBD SIDE)
Condition: Unknown
Due 25 January 1993
Resolved 25 January 1993
Navigation
Issued 7 December 1992 Resolved
RETIGHTEN PACKING ON BOTH RUDDER POSTS.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Construction/Loadline
Issued 7 December 1992 Resolved
MAKE PERMANENT REPAIRS TO ENGINE COMPARTMENT HATCH, CHANNEL DRAIN PVC PIPE WHERE BROKEN. (PORT HATCH--INBOARD)
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Accommodation/Occupational Safety
Issued 7 December 1992 Resolved
RETIGHTEN STBDSIDE HANDRAIL (FWD SECTION).
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Construction/Loadline
Issued 7 December 1992 Resolved
REPLACE FOREDECK THROUGH HULL AND SCREW IN INSPECTION COVER.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Construction/Loadline
Issued 7 December 1992 Resolved
PERMANENTLY MOUNT HATCH IN COLLISION BULKHEAD.
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Navigation
Issued 7 December 1992 Resolved
MAKE PERMANENT REPAIRS TO STEERING LINKAGE WHERE HYDRAULIC RAM CONNECTS TO LINKAGE. (PIN HOLE IS WORN)
Condition: Unknown
Due 7 December 1992
Resolved 7 December 1992
Navigation
Issued 10 February 1992 Resolved
HAVE COMPASS REPAIRED/REPLACED BEFORE CARRYING PASSENGERS. THE DEVIATION CARD CURRENTLY SHOWS DEVIATIONS FROM 10 DEGREES TO 30 DEGREES WEST.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Lifesaving
Issued 10 February 1992 Resolved
FIND AND SEAL LEAK TO LIFE PRESERVER STOWAGE AREA.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Lifesaving
Issued 10 February 1992 Resolved
PROVIDE ONE RING BUOY WITH LIGHT AND LINE BEFORE CARRYING PASSENGERS.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Navigation
Issued 10 February 1992 Resolved
REPAIR AND PROVE OPERATION OF THE STERN LIGHT BEFORE CARRYING PASSENGERS.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Engineering
Issued 10 February 1992 Resolved
REPAIR/REPLACE RAW WATER PUMP ON THE PORT MAIN DRIVE ENGINE.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Documentation
Issued 10 February 1992 Resolved
PROVIDE CURRENT STICKER FOR THE VESSEL'S OFFICIAL DOCUMENT.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Documentation
Issued 10 February 1992 Resolved
PROVIDE EVIDENCE OF A DRUG TESTING PROGRAM.
Condition: Unknown
Due 10 February 1992
Resolved 10 February 1992
Documentation
Issued 10 February 1992 Resolved
PROVIDE LIST FOR SENIOR DECKHAND.
Condition: Unknown
Due 4 March 1992
Resolved 4 March 1992
Lifesaving
Issued 25 March 1991 Resolved
PROVIDE ONE RING BUOY IN CONJUNCTION WITH LIFE FLOAT. TOTAL PEOPLE ABOARD IS LIMITED TO 25 UNTIL ITEM IS PROVIDED.
Condition: Unknown
Due 25 March 1991
Resolved 25 March 1991
Documentation
Issued 7 March 1991 Resolved
PROVIDE DRUG TESTING PROGRAM.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Documentation
Issued 7 March 1991 Resolved
PROVIDE MARPOL V PLACARD.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Documentation
Issued 7 March 1991 Resolved
PROVIDE WASTE DISPOSAL PLAN.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Lifesaving
Issued 7 March 1991 Resolved
REPAIR/REPLACE GRAB LINES ON LIFE BUOYS.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Navigation
Issued 7 March 1991 Resolved
PROVIDE COMPASS DEVIATION CARD.
Condition: Unknown
Due 7 March 1991
Resolved 7 March 1991
Navigation
Issued 2 February 1990 Resolved
REPAIR AND TEST RADAR.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Engineering
Issued 2 February 1990 Resolved
INSTALL BELT GUARDS FOR BOTH MAIN DIESEL ENGINES.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Engineering
Issued 2 February 1990 Resolved
RESTENCIL EMERGENCY FUEL SHUTOFFS.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Engineering
Issued 2 February 1990 Resolved
MOUNT ACCESS WRENCH FOR EMERGENCY FUEL SHUTOFFS AT SHUTOFF LOCATION.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Documentation
Issued 2 February 1990 Resolved
PROVIDE CURRENT DOCUMENT WITH CHANGE OF OWNERSHIP INFORMATION.
Condition: Unknown
Due 2 February 1990
Resolved 2 February 1990
Documentation
Issued 7 March 1989 Resolved
PROVIDE A CURRENT RADIOTELEPHONY SAFETY CERTIFICATE
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Navigation
Issued 7 March 1989 Resolved
MAKE RADAR OPERATIONAL
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Engineering
Issued 7 March 1989 Resolved
REPAIR BILGE PUMP DRIVEN BY STBD MAIN ENGINE
Condition: Unknown
Due 7 March 1989
Resolved 7 March 1989
Accommodation/Occupational Safety
Issued 2 February 1989 Resolved
REMOVE CORRODING ENGINE SPACE VENT DUCT STBD SIDE AND REPLACE USING GOOD MARINE PRATICE.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Navigation
Issued 2 February 1989 Resolved
DRILL AND COTTER PIN THROUGH BOLT IN WAY OF STBD RUDDER TIE ROD.
Condition: Unknown
Due 2 February 1989
Resolved 2 February 1989
Construction/Loadline
Issued 12 April 1988 Resolved
REMOVE OIL FROM ENGINEROOM BILGE.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Documentation
Issued 12 April 1988 Resolved
PROVIDE CURRENT FCC RADIOTELEPHONY CERTIFICATE.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Construction/Loadline
Issued 12 April 1988 Resolved
PROVIDE ACCESS TO VOID SPACE FORWARD OF COLLISION BULKHEAD IN ACCORDANCE WITH COAST GUARD REGULATIONS.
Condition: Unknown
Due 12 April 1988
Resolved 12 April 1988
Lifesaving
Issued 8 April 1986 Resolved
SIX PFDS IN NEED OF REPAIR OR REPLACEMENT.
Condition: Unknown
Due 8 April 1986
Resolved 8 April 1986
Unknown
Issued 23 October 1985 Resolved
REPLACE STBD. WINDOW BEHIND STOVE IN MAIN CABIN.
Condition: Unknown
Due 23 October 1985
Resolved 23 October 1985
Construction/Loadline
Issued 23 October 1985 Resolved
INSTALL KEEPER CHAIN ON LAZARETTE HATCH.
Condition: Unknown
Due 23 October 1985
Resolved 23 October 1985
Electrical
Issued 16 January 1985 Resolved
REPAIR OR REPLACE WOODEN BATTERY BOX WITH LEAD LINED OR FIBREGLASSED LINED BOX.
Condition: Unknown
Due 16 January 1985
Resolved 16 January 1985