← All vessels
JONATHAN WOODWARD
Passenger (Inspected) · Passenger Ship class · Built 1970s · USCG Heartland District (CGD-H) · Other hulls named JONATHAN WOODWARD
JONATHAN WOODWARD is a 1977 passenger vessel (inspected). The Coast Guard has recorded 58 inspections since 1983, most recently in December 2025, along with 36 deficiencies and 1 operational control.
Records from 1983 to 2025. Most recent: inspection, 24 December 2025.
- Built
- 1977
- Last inspected
- 24 December 2025
- Documentation
- Valid · documentation file of 10 September 2026
- Deficiencies
- 36 recorded · 0 without a recorded resolution
- Controls
- None recorded without a removal date
Identity
586207
WDJ6520
49340
Flag
UNITED STATES
367798590
Maury page id
psix-49340
Inspections, by type
…with no type recorded5
Years with a record
35 calendar years (1983–2025)
The 58 inspections in the strip above, split by the kind of activity the US
Coast Guard recorded. Years with a record are calendar years in which a record exists, not
years in service. What Maury does not do.
Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.
Documentation record
Registered dimensions (L × B × D)61.0 ft × 16.6 ft × 7.7 ft
Registered tonnagegross 50 / net 34
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderBREAUX'S BAY CRAFT INC · LOREAUVILLE LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing porthouston, TX
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 16 February 2026 · expires 31 March 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it50 - Regulatory (Subpart C or D), Gross Ton
34 - Regulatory (Subpart C or D), Net Ton
34 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Radio station licence
WDJ6520MMSI 367798590 · active · compulsorily equipped · granted 7 July 2017, expires 7 July 2027
WTG2243MMSI not assigned · expired · compulsorily equipped · granted 16 September 1997, cancelled 15 December 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its
US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown.
A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.
Inspection history · 58
24 December 2025
Annual Inspection · Internal Structural Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8287077
9 December 2025
Drydock Exam · Internal Structural Exam · Examination of Repairs · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8279772
27 January 2025
Administrative Inspection · Internal Structural Exam · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8070243
7 January 2025
Administrative Inspection · Simplified Stability Test · In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8059340
19 November 2024
In-Service Inspection
Physical examination · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 8040016
10 June 2024
Administrative Inspection · Drydock Exam · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7931864
9 August 2023
Deficiency Check · Internal Structural Exam · Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7764387
31 May 2023
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7701843
13 January 2023
Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7621198
15 December 2022
In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7609761
26 July 2022
COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7516713
21 June 2022
Examination of Repairs · Drydock Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7482964
6 October 2021
Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7323379
15 April 2021
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7176059
24 July 2020
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7015053
1 July 2020
Hull Examination · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6998872
12 September 2019
Annual Inspection · DAPI Audit · Administrative Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6810437
8 October 2018
Annual Inspection · Internal Structural Exam · DAPI Audit
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6557097
13 June 2018
Deficiency Check · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6442236
13 July 2017
Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6207484
4 August 2016
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5970605
12 November 2015
Deficiency Check · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5762311
10 October 2014
Internal Structural Exam · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5002843
14 May 2014
Internal Structural Exam · Drydock Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4846823
25 July 2012
Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4269028
16 September 2011
Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 4146694
8 August 2011
Annual Inspection · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4109148
16 September 2010
Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3850931
30 July 2009
Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3550380
21 July 2008
Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3269898
19 June 2008
Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3240830
19 July 2007
Simplified Stability Test
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 3001006
16 July 2007
COI Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2997183
3 August 2006
Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2734856
25 July 2006
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2724039
21 June 2006
Hull Examination · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2680558
13 July 2005
Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2428025
28 June 2004
Annual Inspection · Hull Examination · Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 2125864
29 July 2003
Annual Inspection
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1866297
20 June 2002
COI Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1633912
9 September 1995
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 877323
10 December 1993
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 134632
31 March 1993
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1146721
4 April 1992
Re-Inspection · Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1256695
12 December 1991
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1260223
24 April 1991
Deficiency Check
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 909650
22 March 1991
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1211898
14 June 1990
Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1211372
15 March 1990
Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 923084
8 March 1989
Re-Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1202500
23 March 1988
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1293804
15 September 1987
Re-Inspection · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1005382
20 August 1986
Credit Drydock
Administrative · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1011792
26 March 1986
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 996875
27 March 1985
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1287982
4 April 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1281375
9 March 1984
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 975651
9 March 1983
Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 967884
Deficiency record · 36
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 27 January 2025
Resolved
Vessels operated beyond the 20 nautical mile limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from the nearest land, must be equipped with a MF-DSC frequency transmitter. Vessel is not equipped with a MF-DSC frequency transmitter. The vessel is limited to operating within 20 nautical miles from land until a MF-DSC frequency transmitter is installed.
46CFR184.502
47CFR80.905
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 20 November 2024
Resolved
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Repairs or alterations that affect the safety of the vessel include, but are not limited to: replacement, repair, or refastening of deck or hull planking, plating, and structural members; repair of plate or frame cracks; damage repair or replacement, other than replacement in kind, of electrical wiring, fuel lines, tanks, boilers and other pressure vessels, and steering, propulsion and power supply systems; alterations affecting stability; and repair or alteration of lifesaving, fire detecting, or fire extinguishing equipment.
Vessel is required to conduct a stability test due to a swap of both the port and starboard engines and associated piping.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 24 August 2023
Resolved
All machinery must be installed in such a manner as to afford adequate protection from causing personnel injury. The starboard engine has an exposed rotating belt. Rectify to the satisfaction of the attending marine inspector.
05 - Radio Communications › N/A - No Subsystem › VHF radio installation
Issued 31 May 2023
Resolved
Vessels subject to part III of title III of the Communications Act that operate in the waters described in § 80.901 must, at a minimum, be equipped as follows: Vessels operated solely within 20 nautical miles of land must be equipped with a VHF–DSC radiotelephone installation
47 CFR 80.905
07 - Fire Safety › N/A - No Subsystem › Fire detection and alarm system
Issued 27 December 2022
Resolved
Fire Detection - Vessels described by 46 CFR 175.110 (c) must have an interconnected fire detection system in compliance with 46 CFR 181.450 installed in all enclosed areas where passengers and crew have routine access, including accommodation spaces and machinery spaces. Vessel has not installed the interconnected detection and alarm systems to meet the new regulations outlined in 181.450. Vessel will install and test to the satisfaction of the attending MI and the vessel will be limited to a route of limited coastwise. 46 CFR 181.405 (c)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 6 October 2021
Resolved
Installation of diesel engine exhaust pipe shall be in accordance with 182.15-20 which states that exhaust piping shall be gas tight throughout its length. Exhaust leak observed on starboard main engine at the connection to the inboard manifold. (Cite: 46 CFR 182.20-20)
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 6 October 2021
Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed or hazardous places such as gears, machinery, etc. Bilge pump and generator require guards on rotating attachments. (Cite: 46 CFR 177.35-15)
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 6 October 2021
Resolved
Small passenger vessels sailing more than 20 NM from shore must carry an MF radio. Vessel MF radio inoperative. Restricted to 20 NM from shore until repaired.
Lifesaving › Buoyant Apparatus › Lifeline
Issued 13 June 2018
Resolved
Lifeline and pendants. The lifeline and pendants must be as furnished by the manufacturer with the approved life float or buoyant apparatus. Replacement lifeline and pendants must meet the requirements in subpart 160.010 of this chapter. Vessel's Buoyant Apparatus lifeline straps have worn beyond intended use.
Engineering › Steering Gear System › Piping
Issued 13 July 2017
Resolved
If subject to pressure of more than 150 psig, will be designed, fabricated and inspected in accordance with standard specified by commandant. Install/Rebuild open bridge helm pump to specified standard.
Engineering › Bilge Water Management System › Valve
Issued 12 November 2015
Resolved
Remote shut off valve rod forward of collision bulk inoperable.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 12 November 2015
Resolved
MOB and Fire drills not performed due to lack of crew in attendance.
Electrical › Electric Generation Source (service) › Generator
Issued 8 August 2011
Resolved
Clean windings on generator.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 8 August 2011
Resolved
Replace fractured weld on bulkhead in way of exhaust piping.
Engineering › Diesel Engine (propulsion-reduction gear) › Piping (exhaust)
Issued 8 August 2011
Resolved
Provide double clamp on starboard main engine exhuast.
Engineering › Sea-water System (primary cooling) › Piping
Issued 8 August 2011
Resolved
Remove kink from starboard water injection hose.
Documentation › Markings/Placards › Injury Placard
Issued 16 September 2010
Resolved
Vessesl does not have emergency broadcast placard.
Lifesaving › Embarkation Appliances/Stations › Steps
Issued 21 July 2008
Resolved
Rescue platform not labeled.
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 21 July 2008
Resolved
Stern light connection loose and would not allow connection for light to function.
Electrical › Electric Supply System (service) › Cable
Issued 16 July 2007
Resolved
Properly secure overhead wiring in the water tank/fwd fuel tank compartment.
Engineering › Sea-water System (primary cooling) › Valve
Issued 16 July 2007
Resolved
Replace valve head to the seawater intake for the service gen.
Accommodation/Occupational Safety › Potable Water System › General
Issued 16 July 2007
Resolved
Properly mount 10 gal potable water tank. Tank found below deck to be in service but not mounted and possibly becoming a hazard.
Lifesaving › Lifefloat › Serviceable
Issued 25 July 2006
Resolved
Replace lifefloat.
Engineering › Sea-water System (primary cooling) › Piping
Issued 25 July 2006
Resolved
Replace water jacket discharge piping overhead straps, port & stbd.
Documentation › Certificates/Documents › Cargo Ship Safety Radio Certificate
Issued 28 June 2004
Resolved
Captain could not locate the FCC Safety Radio Certificate. Locate or obtain Safety Radio Certificate and place on board the vessel.
Engineering › Sea-water System (primary cooling) › Sea Chest
Issued 22 June 2004
Resolved
Sea chests had excessive marine growth. Required cleaning.
Engineering › Shafting/Propeller Arrangements › Bearing
Issued 22 June 2004
Resolved
Strutt bearings worn down and need to be replaced.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 June 2004
Resolved
Wiring that is held in place by plastic wire ties must have approved wire supports installed every 24 inches.
Electrical
Issued 4 April 1992
Resolved
COVER HOLE IN MAIN ELECTRICAL PANAL IN ENGINE ROOM.
Electrical
Issued 4 April 1992
Resolved
REPAIR GENERATOR ENGINE BED MOUNTS.
Electrical
Issued 4 April 1992
Resolved
INSTALL BLANK IN WHEEL HOUSE PANAL.
Electrical
Issued 4 April 1992
Resolved
PROVE PROPER OPERATION OF GENERATOR OVERSPEED TRIP.
Construction/Loadline
Issued 22 March 1991
Resolved
PROVIDE WIRE STUFFING TUBES OR PLUGS FOR ALL OPEN HOLES ON FORWARD ENGINEROOM BULKHEAD._x001C_ _x001C_ _x001C_
Electrical
Issued 22 March 1991
Resolved
PROVIDE A PULLEY GUARD FOR THE SHIPS SERVICE GENERATOR._x001C_ _x001C_ _x001C_ _x001C_
Electrical
Issued 22 March 1991
Resolved
PROVIDE SHIELDING FOR ELECTRICAL WIRING IN ENGINEROOM AS NEEDED TO REPLACE ALL DRY ROTTED SHIELDING CURRENTLY USED. _x001C_ _x001C_ _x001C_
Navigation
Issued 22 March 1991
Resolved
RENEW PIN HOLE ON RAM SIDE OF STEERING QUADRANT TO REMOVE EXCESSIVE PLAY._x001C_ _x001C_ _x001C_ _x001C_
Ownership record
The Coast Guard's documentation record for this hull -- the Abstract of Title,
with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National
Vessel Documentation Center, files it here with its date, and every reader of this page gets it.