Records from 2016 to 2026. Most recent: inspection, 6 April 2026.
Inspection history · 19
6 April 2026
Vessel Attendance · COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8293635
29 October 2025
DAPI Audit
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8268541
28 October 2025
Administrative Inspection · Drydock Exam · Internal Structural Exam · DAPI Audit
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8178377
21 April 2025
Drydock Extension · Deficiency Check · Annual Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 8114076
3 May 2024
Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7943220
22 April 2024
Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7899573
19 April 2023
Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7654923
25 April 2022
Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7417468
4 May 2021
Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7189218
20 April 2021
Deficiency Check · COI Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7169945
20 August 2020
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 7039147
26 June 2020
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6987709
21 October 2019
Damage Survey · Administrative Inspection · Examination of Repairs · Hull Examination
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6838730
11 April 2019
DAPI Audit · Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6660608
26 March 2018
Annual Inspection · DAPI Audit · Administrative Inspection · Deficiency Check
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6381367
3 February 2017
COI Inspection · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 6082425
3 June 2016
Deficiency Check · Administrative Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5922489
8 April 2016
DAPI Audit · Administrative Inspection · Annual Inspection
Physical examination · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5850240
1 February 2016
Administrative Inspection
Administrative · Sector Upper Mississippi River · USCG Heartland District (CGD-H) · Activity 5807358
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 21 April 2025
Resolved
A vessel must carry one floating waterlight, unless it is limited to daytime operation, in which case no floating waterlight is required. Battery found in waterlight was not correct type as per manufacturer's instructions. Replace with appropriate type battery.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2025
Resolved 18 May 2025
Resolution: New waterlight with new batteries properly installed with ring buoy.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 April 2025
Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. For equivalent kits, the contents must be stowed in a suitable, watertight container that is marked “First-Aid Kit”. A first-aid kit must be easily visible and readily available to the crew. First aid kit contained expired items.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 21 May 2025
Resolved 15 May 2025
Resolution: First aid kit updated with non-expired items.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 22 April 2024
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of machinery, fuel, and piping systems, including the following: (a) Operation of the main propulsion machinery both ahead and astern.
The throttle control for the main engines was inoperable, and were unable to get the vessel underway to conduct a man overboard drill.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2024
Resolved 3 May 2024
Resolution: MIs attended vessel and got underway for sea trial to test throttle controller. All Sat
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 22 April 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The auxiliary generator was leaking coolant.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2024
Resolved 26 June 2024
Resolution: Witnessed proper operation with no leaks.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 22 April 2024
Resolved
Machinery and equipment installed on each vessel must be suitable for the vessel and its operation and for the purpose intended. All machinery and equipment must be installed and maintained in such a manner as to afford adequate protection from causing fire, explosion, machinery failure, and personnel injury. The housing containing the bilge high water alarm was found to be cracked/broken.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 29 May 2024
Resolved 26 June 2024
Resolution: A new bilge sensor was installed, verified all sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 19 April 2023
Resolved
Each item of lifesaving equipment determined by the marine inspector to be not in serviceable condition must be repaired or replaced. Inspection found the handgrab line around the ring lifebuoy broken.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 1 May 2023
Resolution: Received photo showing new life ring.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 April 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers, crew, other persons, and the vessel from electrical hazards. Inspection found distribution panel had missing blank-off for circuit breaker.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 17 May 2023
Resolution: Received photo evidence of blank-off installed.
11 - Life Saving Appliances › N/A - No Subsystem › Distress flares
Issued 19 April 2023
Resolved
A vessel on a lakes, bays, and sounds, and rivers routes must carry 6 hand red flare distress signals approved in accordance with 160.021. Inspection found 2 of 6 red hand flares expired.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 19 May 2023
Resolution: Received photo evidence of new flares onboard.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 19 April 2023
Resolved
Gauges to indicate engine RPM for all propulsion engines installed must be readily visible at the operating station. Inspection found the port main engine RPM gauge at the pilothouse was operating intermittently.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 15 May 2023
Resolution: Received photo evidence of RPM gauge stabilized.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 19 April 2023
Resolved
Electrical equipment on a vessel must be installed and maintained to protect passengers crew, other persons and the vessel from electrical hazards, including fire. Inspection found pilothouse electrical circuit overloaded with multiple multi-outlet strips daisy chained and electrical extension cords utilized to energize exterior deck lighting. Reduce the load on the electrical circuit to only what installed outlets allow and remove extension cords.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 19 May 2023
Resolved 15 May 2023
Resolution: Received photo evidence of electrical cords/strips removed from pilothouse.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 May 2021
Resolved
Any vessel of at least five net tons which engages in coastwise trade must have a Certificate of Documentation (COD) bearing a valid endorsement appropriate for the activity in which engaged. Prove to the Coast Guard marine inspector that vessel holds a valid Certificate of Documentation (COD).
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Other (certificates)
Issued 4 May 2021
Resolved
A vessel to which Small Passenger Vessels regulations apply may not be operated without having on board a valid U.S. Coast Guard Certificate of Inspection (COI). COI issued on 20APR2021 is not valid due to Tropic Island Cruises Inc listed as the owner [name withheld] for Inspection CG-3752 upon new Certificate of Documentation (COD) issuance.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 24 May 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 21 April 2021
Resolved
The owner or managing operator must provide satisfactory evidence of the required servicing‘s (Fire protection) to the marine inspector. Pre-engineered fixed gas fire extinguishing system annual service was conducted but service report did not indicate that the bottle was weighed. Provide documentation or prove to the attending Coast Guard marine inspector that bottle was weighed.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 5 May 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
07 - Fire Safety › N/A - No Subsystem › Evaluation of crew performance (fire drills)
Issued 21 April 2021
Resolved
Conduct and log crew training and drills to include fire drill, man overboard drill, and abandon ship drill in accordance with 46CFR185.512, 185.520, and 185.524.
Action required: 10 - Deficiency Rectified
Resolved 21 April 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 21 April 2021
Resolved
STBD side main engine jacket water temperature gauge in operating station is not working. Approved to the attending Coast Guard marine inspection that the gauge in the operating station is working.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 5 May 2021
Resolved 25 May 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 21 April 2021
Resolved
A vessel must carry either a first aid kit approved under approval series 160.041 or a kit with an equivalent contents and instructions. First aid kit had expired aspirin. Prove to the attending Coast Guard marine inspector that no items in the first aid kit are expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 7 May 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 21 April 2021
Resolved
A vessel must be provided with a satisfactory arrangement for draining any watertight compartment. During inspection it was discovered that two ball valves on the suction side of the bilge pump were cracked. Prove proper operation of entire bilge system to the attending Coast Guard marine inspector.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 23 April 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
01 - Certificates & Documentation › 011 - Ships Certificates › Certificate of Inspection (COI)
Issued 26 June 2020
Resolved
The vessel must undergo an annual inspection within the 3 months before of after each anniversary date (14 MAR 2020). The vessels annual inspection is overdue. Prior to carrying passengers the vessel must complete an annual inspection to the satisfaction of an attending USCG Marine Inspector.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 21 April 2021
Resolution: Cleared to the satisfaction of the Coast Guard marine inspector.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 6 November 2019
Resolved
Whenever damage or deterioration to hull plating or structural members that may affect the seaworthiness of vessel is discovered the owner/operator shall make permanent repairs. During dry dock/internal structural examination inspection there were two areas of concern: First, The engine room starboard longitudinal bay bilge and side shell had severe corrosion areas. Ultra sonic testing revealed the suspect areas were wasted below the minimum allowance. Second, Space #5 aft centerline area (near hotwater tank) severe corrosion and pitting was found. Provide a repair proposal for both engine room and space #5 to the local OCMI for approval. All repairs shall be the same as original construction. All repairs shall be to the satisfaction of the attending USCG marine inspector prior to carrying passengers.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 20 August 2020
Resolution: The deficiency was cleared to the satisfaction of an attending USCG Marine Inspector.
02 - Structural Conditions › N/A - No Subsystem › Hull - corrosion
Issued 8 May 2019
Resolved
Address and arrest corrosion/scaling appearing in bow void compartment.
Condition: Improper/Lack of Maintenance
Action required: 50 - Rectify deficiencies w/in 30 days
Due 8 June 2019
Resolved 22 May 2019
Resolution: On this date, received email verification and photos that this deficiency has been satisfied.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 8 May 2019
Resolved
Life ring buoy on bow, port side is showing signs that outer coating/seal is beginning to fail.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 22 May 2019
Resolution: On this date, received emial verification and photos that have satified this deficiency.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 8 May 2019
Resolved
Both port and starboard main diesel engine reduction gear lube oil cooler hoses are beginning to show signs of deterioration/chaffing.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 13 May 2019
Resolution: On this date, recieved email verification and photos identifying all reduction gear lube oil cooler hoses have been repalced.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 8 May 2019
Resolved
Properly clean ship service generator windings.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 22 May 2019
Resolved 13 May 2019
Resolution: On this date, recieved email verification and photos identifying that the ship service generator windings have been cleaned.
Documentation › Markings/Placards › Capacity Marking
Issued 4 April 2018
Resolved
011301310 - Number of passengers permitted on upper deck IAW stability letter was not marked in 1" letters at either stairwell. Crewmembers must notify all passengers of capacity limitations until markings are in place.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 5 April 2018
Resolution: Both stairwells for upper deck have been appropriately labeled.
Fire Fighting › Fire Pumps › Pressure
Issued 4 April 2018
Resolved
0707113 - Pressure gauge on fire pump appears broken/inadequate, repair or replace pressure gauge on fire pump.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 18 April 2018
Resolved 5 April 2018
Resolution: Pressure gauge has been replaced and operates satisfactorily.
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 4 April 2018
Resolved
11111118 - Boxes containing lifejackets was not labeled with sizes (adult/child) and number of PFDs. Re-stencil boxes with appropriate information.
Action required: 10 - Deficiency Rectified
Due 4 April 2018
Resolved 4 April 2018
Resolution: Re-stenciled prior to completing inspection.
Lifesaving › Hand Flares › Not on Board
Issued 13 March 2017
Resolved
It was discovered that the vessel was missing two (2) day/night hand red distress signals. Vessel was limited to daylight operations only.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 13 April 2017
Resolved 14 March 2017
Resolution: O/O purchased an additional four (4) hand red distress signals.
Documentation › Logs/Records › Drug Test Records
Issued 12 April 2016
Resolved
Provide documentation of the company's Drug and Alcohol and Employee Assistance Programs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 May 2016
Resolved 28 June 2016
Resolution: Recieved an acceptable DAPI Policy and Program.