MAURY USCG vessel records Sign in
← All vessels

CLIPPER CRISTOBAL

CLIPPER CRISTOBAL is a 1999 freight ship. The Coast Guard has recorded 31 inspections since 2002, most recently in June 2014, along with 13 deficiencies and 7 operational controls.

Records from 2002 to 2014. Most recent: inspection, 19 June 2014.

Built
1999
Last inspected
19 June 2014
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

9169873 View on MarineTraffic leaves Maury; a third-party site, nothing from it is stored here
493558
Flag
BAHAMAS, THE
—
Maury page id
psix-493558

Inspections, by type

…with no type recorded12
Years with a record 9 calendar years (2002–2014)
The 31 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 12 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the General Dry Cargo Ship class in Maury's sources begin in 1980.

Documentation record

Tonnage as PSIX records it6714 - Convention (Subpart B), Gross Ton
2890 - Convention (Subpart B), Net Ton
8733 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

No FCC ship-station licence is recorded against this Official Number in the file of 6 September 2026. That is a fact about the licence file, not about the radio.

Inspected as a tow unit · 2

The Coast Guard recorded this vessel and the following in the same inspection activity — normally a tug and the barges in its tow. A recreational or unclassed hull in the same activity is held and not published, so it does not appear here: these lists are a floor, not a complete manifest.

RHA 2201 Tank Barge · MISLE 25404 · 5 April 2009 · activity 4015034AUDREY Towing Vessel · MISLE 90575 · 5 April 2009 · activity 4015034

Inspection history · 31

19 June 2014 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4888860
24 May 2014 Type not recorded
No type recorded · Marine Safety Unit Texas City · USCG Heartland District (CGD-H) · Activity 4864153
19 May 2014 COE-Dockside
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4859442
2 February 2012 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4235178
1 February 2012 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 4236265
15 March 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3693381
19 February 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3682361
19 February 2010 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3684186
7 February 2010 Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3676603
5 July 2009 Type not recorded
No type recorded · Marine Safety Unit Galveston · USCG Heartland District (CGD-H) · Activity 3526092
20 April 2009 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3456878
5 April 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 4015034
27 March 2009 Type not recorded
No type recorded · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3441591
2 March 2009 COE-Administrative
Administrative · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3426417
10 October 2008 Deficiency Check
Physical examination · Sector Houston/Galveston · USCG Heartland District (CGD-H) · Activity 3342043
29 September 2008 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3334633
16 September 2008 PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3325309
15 September 2008 Type not recorded
No type recorded · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3325534
21 March 2007 Deficiency Check
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2892344
19 March 2007 ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Mobile · USCG Heartland District (CGD-H) · Activity 2890885
3 December 2005 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2545264
2 December 2005 PII Safety Exam · ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2544976
1 December 2005 Type not recorded
No type recorded · Vessel Traffic Service Houston-Galveston · USCG Heartland District (CGD-H) · Activity 2562554
13 August 2004 Deficiency Check
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2165119
23 July 2004 ISPS II Exam
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 2143050
25 May 2004 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 2078211
13 April 2004 Deficiency Check
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2043374
10 March 2004 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2022391
6 January 2004 Annual Inspection
Physical examination · MSO HONOLULU · USCG Oceania District (CGD-O) · Activity 1970965
6 January 2004 Type not recorded
No type recorded · GROUP HONOLULU · USCG Oceania District (CGD-O) · Activity 1976443
13 April 2002 Annual Inspection
Physical examination · MSO MIAMI · USCG Southeast District (CGD-SE) · Activity 1604330

Deficiency record · 13

Engineering › Thrusters › Motor
Issued 19 February 2010 Resolved
The Captain of the Port (COTP) Sector Houston-Galveston was notified the CEC CRISTOBAL experienced a temporary loss of power due to a faulty generator. CG Port State Control Officers dispatched to vessel. More to follow. OPCON 2010-0166 issued.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 February 2010
Resolution: Received Class report attesting that the loss of power was isolated only to the bow thruster and vsl did not lose propulsion or steering. Surveyor verified operational procedures were posted, satisfactorily tested bow thruster under load, and tested gens
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 16 September 2008 Resolved
Both fire doors in the galley are not self-closing as desiganted by the fire plan. Rectify to the satisfaction of class.
Condition: Design Flaw
Action required: 40 - Rectify deficiencies prior to next US port after sailing foreign
Resolved 10 October 2008
Resolution: Cleared by class (LR) report.
Deck/Cargo › Cargo Stowage › General
Issued 16 September 2008 Resolved
One of the support brackets on the cargo hold, starboard side forward, is broken off due to cargo operations. Rectify to the satisfaction of class.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 September 2008
Resolved 10 October 2008
Resolution: Cleared by class (LR) report.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 March 2007 Resolved
Self closing class "A" fire doors in main ladder way do not close by themselves as designed. Closing devices to be adjusted or replaced for correct operation, prior to departure from port to the satisfaction of the Administration. SOLAS II-2/ Reg. 9, 2.2.5.1
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Resolution: Attended vessel and observed proper operation of all class "A" fire doors.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 19 March 2007 Resolved
Class "A" fire doors in main ladder way are missing locks above handles. Pieces of metal are glued over the holes where the locks once existed. Administration to verify and attest that the class "A" fire boundary is not compromised. Repair/replace locks or holes prior to departure from port. SOLAS II-2/ Reg. 9, 2.2.5.1
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Resolution: Attended vessel and observed vessel had replaced pieces of metal that were glued to door with original locks.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 19 March 2007 Resolved
Piping/Flanges for thermo oil for fuel and oil tanks are leaking. Associated laggin is oil soaked. Classification Society to inspect and make recommendations for repair prior to departure from port. SOLAS II-1/ Reg. 3-1.
Condition: Unknown
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 March 2007
Resolution: Attended vessel and received Class report attesting to outstanding condition of class.
Lifesaving › Lifeboat › Rudder/Tiller/Steering
Issued 2 December 2005 Resolved
Seal around steering wheel in freefall lifeboat is wasted and is leaking hydraulic fluid. When steering was tested the fluid was too low to operate the rudder. Seal needs to be replaced.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Resolved 3 December 2005
Resolution: Received confirmation from captain that seal was replaced. Deficiency was removed.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 13 April 2004 Resolved
Make all repairs necessary to SSG#2 so that it can be reinstalled onto Prime Mover. Make repairs to the satisfaction of Class by the next U.S. port after sailing foreign.
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 25 May 2004
Resolution: BOARDED VESSEL AND RECEIVED CLASS REPORT STATING THAT THE SSG#2 HAS BEEN REPLACED AND OBSERVED GENERATOR OPERATING CORRECTLY.
Engineering › Generator (propulsion/auxiliary-electric)
Issued 6 January 2004 Resolved
REINSTALL SSG#3 ONTO PRIME MOVER. SOLAS II-I REG 43.6
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 13 April 2004
Resolution: SSG#3 OPERATIONAL
Pollution Prevention/Response › Prevention Equipment
Issued 6 January 2004 Resolved
Make repairs to type II marine sanitation device. Air compressor pump motor needs to be repaired and reinstalled. 33 CFR 159.7 (A)(1) LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Condition: Unknown
Action required: 15 - Rectify deficiencies by next port
Resolved 13 April 2004
Resolution: New Air Compressor Pump installed and MSD operational
Deck/Cargo › Vapor Control Systems
Issued 6 January 2004 Resolved
Install lube oil vent flame screens.( Rear lube oil, thermal lube oil, Aux engine lube oil, main engine lube oil & sludge oil tank.) SOLAS Ch. I Reg. 11 LEGACY COMPONENT DESC: Flame Screens
Condition: Improper/Lack of Maintenance
Action required: 15 - Rectify deficiencies by next port
Resolved 13 April 2004
Resolution: Vent Flame Screens installed.
Fire Fighting › Fire Pumps
Issued 13 April 2002 Resolved
Make repairs to #1 fire pump discharge gauge. Gauge is disconnected. LEGACY COMPONENT DESC: Gauge
Action required: 705 - Other - as specified
Due 13 May 2002
Resolved 6 January 2004
Resolution: MADE REPAIRS TO #1 FIRE PUMP DISCHARGE GAUGE.
Pollution Prevention/Response › Prevention Equipment
Issued 13 April 2002 Resolved
Marine sanitation device approval certificate has expired. Vessel to get approval for MSD. LEGACY COMPONENT DESC: Marine Sanitation Device, Type II
Action required: 705 - Other - as specified
Due 13 May 2002
Resolved 6 January 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.