MAURY USCG vessel records
← All vessels

ITB VANCOUVER

ITB VANCOUVER is a 1999 tank barge. The Coast Guard has recorded 20 inspections since 1999, most recently in April 2023, along with 5 deficiencies.

Records from 1999 to 2023. Most recent: inspection, 18 April 2023.

Built
1999
Last inspected
18 April 2023
Documentation
Not in the documentation file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 3 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 18 April 2023
…with no type recorded2
Operational controls None recorded without a removal date
Years with a record 19 calendar years (1999–2023)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

8645909
493560
Flag
CANADA
Maury page id
psix-493560

Documentation record

Tonnage as PSIX records it2051 - Convention (Subpart B), Gross Ton
1112 - Convention (Subpart B), Net Ton
4701 - Dead Weight, Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026 for this class, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspection history · 20

18 April 2023 COC-TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7670288
7 July 2022 COC-TVE Annual
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 7489130
14 July 2021 COC-TVE Renew
Administrative · Marine Safety Unit Portland OR · USCG Northwest District (CGD-NW) · Activity 7253924
16 May 2019 COC-TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6683135
30 April 2018 COC-TVE Annual
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6402451
10 May 2017 COC-TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 6132642
10 May 2016 Administrative Inspection · COC-TVE Annual · Deficiency Check
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5863831
14 May 2015 COC-TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 5110145
12 May 2014 COC-TVE Annual
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4843061
28 June 2012 COC-TVE Annual
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 4375896
19 May 2009 Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3502163
17 January 2008 COC-TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3132998
11 October 2006 COC-TVE Renew
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2798565
14 October 2004 COC-TVE Annual
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2219248
3 September 2003 Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1896116
26 July 2002 Certificate of Compliance · MARPOL Annex I Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1657101
23 July 2001 Certificate of Compliance
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1646314
7 July 2000 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 282302
7 July 2000 Tank Vessel Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1369818
9 July 1999 Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 430623

Deficiency record · 5

Electrical › Lighting (service) › Grounding Conductor
Issued 10 May 2016 Resolved
0950-Electrical equipment in general-Electric installations on vessel must ensure protection of passengers, crew, other persons, and the vessel from electricla hazards. Vessel's 24V ground fault detection was showing a ground fault- 46CFR32.45-1
Action required: 705 - Other - as specified
Due 10 June 2016
Resolved 31 May 2016
Resolution: Vessel submitted a class report to rectify deficiency.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Transfer Hose
Issued 10 May 2016 Resolved
1199-Other(cargo)-Hoses used to transfer oil or hazardous material must meet the requirements of 33CFR154.500. Each hose must be marked with the name of each product must be marked with the name of each product for which the hose may be used. All hoses were missing the name of the product for which the hose was to be used.-33CFR155.800
Action required: 705 - Other - as specified
Due 25 May 2016
Resolved 31 May 2016
Resolution: Vessel submitted a class report to rectify deficiency.
Deck/Cargo › Holds/Tanks › Valve, Pressure Vacuum Relief
Issued 17 January 2008 Resolved
Provide copy of PV Valve servicing certificates
Due 28 January 2008
Resolved 28 January 2008
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 17 January 2008 Resolved
Provide proper labeling for Emergency Shutdown on the Barge Office Bulkhead
Due 28 January 2008
Resolved 28 January 2008
Pollution Prevention/Response › Prevention Equipment › Overfill Devices
Issued 14 October 2004 Resolved
Prove proper operation of high-high level visual indicator.
Action required: 701 - Prior to carriage of passengers/cargo
Due 21 October 2004
Resolved 21 October 2004

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.