MAURY USCG vessel records
← All vessels

HUGH

Built
1977
Last inspected
19 January 2017
Documentation
No record in the NVDC file of 10 August 2026
Controls
None recorded without a removal date

This record may be incomplete: the most recent inspection recorded for this vessel was 9 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Barge class in Maury's sources begin in 1972.

Inspection record

Last inspected 19 January 2017
…with no type recorded27
Operational controls None recorded without a removal date
Years with a record 33 calendar years (1981–2017)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

Flag
UNITED STATES
Maury page id
psix-49381

Documentation record

Tonnage as PSIX records it4397 - Convention (Subpart B), Gross Ton
2056 - Convention (Subpart B), Net Ton
This hull's Official Number is not in the NVDC file dated 10 August 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.
Professional
The full record for this vessel

Behind this panel: 105 inspections, each with its date, unit and type; 64 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; 6 other vessels inspected with it; no other recorded names; no NVDC documentation record for this Official Number. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report
Every record for this hull, in one document — $299

Every recorded inspection, 1972 to 2026, in one chronology · every deficiency, with system, dates and resolution · operational controls imposed and removed · every name this hull has been recorded under · the vessels it was inspected alongside, and when · how its record compares with hulls of similar age and size, as a fact about the population and never a judgement about this vessel.

Read one first, in full: a forty-year chronology · a hull that changed operators four times · the sparse case, shown as an example, not for sale.

This report is in development and is not for sale yet. There is no date, and nothing is charged. Leave an email and we will tell you when it exists, once.

Inspected as a tow unit · 6

Inspection history · 105

19 January 2017 Annual Inspection · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6073440
1 October 2016 Examination of Repairs · Deficiency Check · Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 6016477
19 September 2016 Damage Survey · Examination of Repairs
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 6003965
18 September 2016 Examination of Repairs · Administrative Inspection · Damage Survey
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 6004323
22 August 2016 Examination of Repairs
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5977010
18 August 2016 Permit to Proceed
Administrative · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5977291
24 February 2016 Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5819823
27 July 2015 Drydock Exam · Internal Structural Exam · Cargo Tank Internal · Deficiency Check
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5197947
23 February 2015 COI Inspection · DAPI Audit · Deficiency Check
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 5073145
24 November 2014 Damage Survey · Examination of Repairs
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 5028784
25 October 2014 Deficiency Check
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5012600
21 February 2014 Annual Inspection · MTSA Verification
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4802954
13 December 2013 Damage Survey
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4769048
4 August 2013 Examination of Repairs · Drydock Exam · Internal Structural Exam
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 4674177
25 June 2012 Type not recorded
No type recorded · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4356821
8 February 2012 Annual Inspection
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 4240961
20 August 2010 Examination of Repairs
Physical examination · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3831555
4 August 2010 Administrative Inspection · Internal Structural Exam · Hull Examination
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3814737
8 March 2010 MTSA Verification · COI Inspection
Physical examination · Marine Safety Unit Savannah · USCG Southeast District (CGD-SE) · Activity 3691835
7 January 2010 Type not recorded
No type recorded · Sector Jacksonville · USCG Southeast District (CGD-SE) · Activity 3660082
7 September 2009 Administrative Inspection
Administrative · Commandant (CG-CVC) · Activity 3588299
21 August 2009 Examination of Repairs
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 3576500
17 July 2009 Administrative Inspection
Administrative · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3537385
17 June 2009 Annual Inspection
Physical examination · Marine Safety Unit Duluth · USCG Great Lakes District (CGD-GL) · Activity 3506318
25 June 2008 MTSA Verification · MARPOL Annex II Examination · Cargo Tank Internal · Internal Structural Exam · Ballast Water Examination · Periodic Inspection
Physical examination · Sector St Petersburg · USCG Southeast District (CGD-SE) · Activity 3246432
30 November 2007 Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3107294
9 July 2007 MARPOL Annex I Examination · Administrative Inspection · Annual Inspection · MTSA Verification
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 2985749
20 April 2006 Annual Inspection · MTSA Verification
Physical examination · Marine Safety Unit Wilmington · USCG East District (CGD-E) · Activity 2626670
9 August 2005 Internal Structural Exam · Cargo Tank Internal · Hull Examination
Physical examination · Sector Virginia · USCG East District (CGD-E) · Activity 2457162
17 June 2005 MTSA Verification
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 2392524
23 March 2005 COI Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2317640
25 October 2004 Type not recorded
No type recorded · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 2235419
28 May 2004 Annual Inspection
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 2084567
25 July 2003 Examination of Repairs · Hull Examination · Internal Structural Exam
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1853148
7 July 2003 Permit to Proceed · Examination of Repairs · Damage Survey
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1838231
30 June 2003 Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 1833056
18 June 2003 Periodic Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1818759
9 October 2002 Deficiency Check
Physical examination · Marine Safety Unit Victoria · USCG Heartland District (CGD-H) · Activity 1687802
9 August 2002 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1658996
16 July 2002 Deficiency Check
Physical examination · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 1647174
12 June 2002 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1629131
12 June 2002 Re-Inspection
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1630235
27 November 2001 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 466761
3 September 2001 Type not recorded
No type recorded · MSO PHILADELPHIA · USCG East District (CGD-E) · Activity 116990
17 July 2001 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1067239
18 June 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 729071
6 June 2001 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 441484
26 May 2001 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1473368
10 August 2000 Hull Examination
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1420375
8 March 2000 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1464919
15 January 2000 Deficiency Check
Physical examination · MSO WILMINGTON · USCG East District (CGD-E) · Activity 1045993
3 May 1999 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1410089
25 March 1999 Deficiency Check
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 777433
23 February 1999 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1131631
19 February 1999 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 54931
21 January 1999 Re-Inspection · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1408229
17 July 1998 Type not recorded
No type recorded · MSO TAMPA · USCG Southeast District (CGD-SE) · Activity 529264
14 April 1998 Type not recorded
No type recorded · Marine Safety Unit Baton Rouge · USCG Heartland District (CGD-H) · Activity 461708
22 March 1998 Type not recorded
No type recorded · MSO CHARLESTON · USCG Southeast District (CGD-SE) · Activity 471432
11 March 1998 Deficiency Check · COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1398861
11 June 1997 Re-Inspection
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1406142
14 February 1997 Examination of Repairs
Physical examination · MSO SAVANNAH · USCG Southeast District (CGD-SE) · Activity 1105498
9 July 1996 Hull Examination
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1089977
20 March 1996 COI Inspection · Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1396483
13 March 1996 Damage Survey
Physical examination · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 1374525
11 March 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 106947
11 March 1996 Type not recorded
No type recorded · MSO JACKSONVILLE · USCG Southeast District (CGD-SE) · Activity 150468
16 June 1995 Administrative
Administrative · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 878194
30 May 1995 Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1417784
28 April 1995 Administrative
Administrative · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1180777
8 February 1995 Examination of Repairs
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1409234
18 November 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 33898
18 November 1994 Type not recorded
No type recorded · MSO WILMINGTON · USCG East District (CGD-E) · Activity 123263
19 May 1994 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 860007
29 April 1994 Hull Examination · COI Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1148888
8 July 1993 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 843474
22 August 1992 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1257860
19 August 1992 Type not recorded
No type recorded · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 25833
14 July 1992 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 951588
12 June 1992 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 947199
30 October 1991 Deficiency Check
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 932589
28 June 1991 Hull Examination · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1249037
21 February 1991 Examination of Repairs
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1225464
24 October 1990 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1218801
15 June 1990 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1227237
30 March 1990 Re-Inspection
Physical examination · MSO HOUSTON/GALVESTON · USCG Heartland District (CGD-H) · Activity 1211834
3 November 1988 Hull Examination · COI Inspection · Deficiency Check
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1204146
14 October 1988 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1197534
3 October 1988 Damage Survey
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1196436
13 June 1988 Re-Inspection
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1212001
15 May 1988 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 888668
28 January 1988 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1020808
16 November 1987 Administrative
Administrative · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1026106
10 July 1987 COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1029958
16 April 1987 Type not recorded
No type recorded · Marine Safety Center (MSC) · Activity 1334386
6 November 1986 Hull Examination
Physical examination · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1324610
9 September 1986 Re-Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1006574
19 July 1985 Credit Drydock · COI Inspection
Physical examination · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 982504
9 July 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 979619
7 March 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 981094
27 February 1985 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 978216
29 December 1984 Type not recorded
No type recorded · MIO HOUSTON · USCG Heartland District (CGD-H) · Activity 1285451
26 November 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1282356
28 September 1984 Type not recorded
No type recorded · MSO HAMPTON ROADS · USCG East District (CGD-E) · Activity 1286791
24 September 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1275528

Deficiency record · 64

Deck/Cargo › Cargo Transfer/Lightering (liquid) › Relief Valve
Issued 6 February 2017 Resolved
Cargo pump relief valves on port/strbd side require annual testing. 46 CFR 35.35-50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 8 February 2017
Resolution: Cargo pump relief valves on port/strbd side tested.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 6 February 2017 Resolved
Cargo piping gauges require annual testing. 46 CFR 35.35-50
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 8 February 2017
Resolution: Cargo piping gauges tested to satisfaction of the Marine Inspector.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Piping
Issued 6 February 2017 Resolved
Cargo pump strbd pump room requires repair to exhaust lagging.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 6 March 2017
Resolved 8 February 2017
Resolution: Lagging repaired in strbd pump room.
Construction/Loadline › Hull › Weld
Issued 1 October 2016 Resolved
Make proper repairs to the following areas within the 2 Port void tank.a. Renew weld on frame 16 were connected to longitudinal in two locations. 46CFR 32.60-1
Action required: 705 - Other - as specified
Resolved 7 October 2016
Resolution: Welds renewed in both locations.
Construction/Loadline › Hull › Weld
Issued 1 October 2016 Resolved
2. Make proper repairs to the following areas within the 2 STBD void tank.a. Renew weld on frame 14 on side shell were connected to longitudinal. b. Renew weld on frame 15 on side shell were connected to longitudinal. 46CFR 32.60-1
Action required: 705 - Other - as specified
Resolved 7 October 2016
Resolution: Welds repaired in both locations.
Construction/Loadline › Hull › Weld
Issued 1 October 2016 Resolved
3. Make proper repairs to the following areas within the 3 STBD void tank.a. Grind out and Renew weld were cracked on frame 19 bracket along previously repair. b. Grind out and Renew weld were cracked on frame 21 bracket along previously repair. c. Grind out and Renew weld were cracked on frame 22 bracket along previously repair. ... see full discription in attached CG-835
Action required: 705 - Other - as specified
Resolved 7 October 2016
Resolution: Inspection of the following repairs in #3 stbd void: 3 cargo tank bottom knuckle saddle supports cracked welds repaired SAT, cracked bottom long replaced SAT, cracked side long replaced SAT, numerous bottom shell clad welds SAT.
Construction/Loadline › Hull › Weld
Issued 1 October 2016 Resolved
4. Make proper repairs to three areas identified by gauging within 4 Port void. 46CFR 32.60-1
Action required: 705 - Other - as specified
Resolved 7 October 2016
Resolution: - Vacuum box test of inserts on bottom shell of #4 port void at centerline and bottom shell of #3 stbd void. SAT.
Construction/Loadline › Hull › Weld
Issued 1 October 2016 Resolved
5. Make proper repairs to the following areas within the 4 STBD void tank. a. Crop out and renew large area identified between frames 30 and 37 as marked. Once Cropped, area will be re-inspected to determine transverse and longitudinal size needed along centerline and aft bulk-head. b. Grind out and renew weld along lap joint between frames 28 and 29. 46CFR 32.60-1
Action required: 705 - Other - as specified
Resolved 7 October 2016
Resolution: Air test of #4 stbd void; tank was pressed to a pressure of 2 psi and held for approx 2 hours prior to spray testing welds. Confirmed 2 PSI at manometer on deck. All welds on bottom shell inserts were sprayed with soapy water and inspected. SAT.
Construction/Loadline › Hull › Bottom Plating
Issued 23 September 2016 Resolved
Provide repair proposal for void 4S hole (1/4") found in bottom plating.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 25 September 2016
Resolution: Temp repair completed. PTP issued for vessel to proceed directly to dry-dock in Tampa, FL.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 23 September 2016 Resolved
Gouge/reweld cracked weld between cargo tanks 4S and void 4S.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 24 September 2016
Resolution: ABS surveyor witnessed satisfactory weld repair and test of new weld.
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 23 September 2016 Resolved
Identify leak between cargo tank 1S and cofferdam 1S. Provide repair proposal.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 25 September 2016
Resolution: Crack identified. DyePen, drill stopped, gouged and welded. Cofferdam aired up and weld tested sat.
Construction/Loadline › Hull › Bottom Plating
Issued 23 September 2016 Resolved
Gauge pitting identified in voids 4S & 4P in presence of marine inspector.
Condition: Invalid
Action required: 705 - Other - as specified
Due 23 September 2016
Resolved 24 September 2016
Resolution: NFSY UT'd and pit gauged suspect areas of bottom plating in presence of [name withheld] docs for report.
Construction/Loadline › Hull › Longitudinal Frame
Issued 31 July 2015 Resolved
1.Either gage or submit a repair proposal for quarter sized pit located in Port #1 ballast tank, in the aft most bay on the 3rd longitudinal from the centerline. 46 CFR 31.10-21
Action required: 705 - Other - as specified
Resolved 9 September 2015
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 31 July 2015 Resolved
Crop and renew deteriorated ladder support in the #1 STBD cofferdam at the top of the ladder. 46 CFR 32.02-15
Action required: 705 - Other - as specified
Resolved 2 September 2015
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 31 July 2015 Resolved
Crop and renew deteriorated ladder support in the #4 STBD cofferdam at the bottom of the ladder. 46 CFR 32.02-15
Action required: 705 - Other - as specified
Resolved 2 September 2015
Construction/Loadline › Structures › Manhole
Issued 31 July 2015 Resolved
Crop and renew deteriorated scuttle hinge on the #4 Port ballast tank hatch. 46 CFR 42.15-20
Action required: 705 - Other - as specified
Resolved 25 August 2015
Construction/Loadline › Hull › Longitudinal Frame
Issued 31 July 2015 Resolved
Crop and renew longitudinal in the #4 Post ballast tank located just below the deck in first bay across from ladder. 46 CFR 31.10-21
Action required: 705 - Other - as specified
Resolved 25 August 2015
Construction/Loadline › Hull › Bottom Plating
Issued 31 July 2015 Resolved
Renew undercut weld on bottom plating approximately 15’ frw from first set of blocks. 46 CFR 31.10-21
Action required: 705 - Other - as specified
Resolved 2 September 2015
Construction/Loadline › Hull › Bottom Plating
Issued 31 July 2015 Resolved
Renew STBD side inset hull plating washed out weld approximately ¾ from bow. 46 CFR 31.10-21
Action required: 705 - Other - as specified
Resolved 2 September 2015
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 23 February 2015 Resolved
Properly remove all dead end wires on navigation light system (all 3 locations)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 March 2015
Resolved 24 February 2015
Resolution: Operator properly removed dead-end wires.
Pollution Prevention/Response › Prevention Equipment › Coamings
Issued 23 February 2015 Resolved
Provide coamings mechanical plugs for anchor and stern windlass.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 2 March 2015
Resolved 24 February 2015
Resolution: Operator provided missing mechanical plugs to the satisfaction of the attending MI.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Emergency Shut-down
Issued 23 February 2015 Resolved
Properly repair CO2 piping (conduit) for pumps prime mover emergency shutdown system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 February 2015
Resolution: Operator replaced damaged section to the satisfaction of attending MI.
Deck/Cargo › Cargo Transfer/Lightering (liquid) › Cargo Pump
Issued 23 February 2015 Resolved
Prove proper operation of emergency shutdown device (selenoid) on port side prime mover. BArge is not allowed to discharge/transfer using port pump/prime mover.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 24 February 2015
Resolution: Operator replaced damaged selenoid, MI tested proper operation of emergency shut-off.
Construction/Loadline › Structures › Deck Plating
Issued 24 November 2014 Resolved
Prior to conducting cargo operations, effect repairs to crack in deck above #3 cargo tank and complete successful testing of repairs.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 November 2014
Resolution: Repairs made. Received ABS report attesting to proper repairs & successful weld testing.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 25 October 2014 Resolved
Barge rep reported inoperative anchoring system.
Action required: 17 - Rectify deficiencies prior to departure
Due 25 October 2014
Resolved 26 October 2014
Resolution: Received, reviewed, and accepted technicians report attesting to the proper operation of the anchoring system. For further details refer to activity narrative.
Construction/Loadline › Hull › Hull Plating
Issued 13 December 2013 Resolved
Damge caused by vessel's anchor, starboard side of the anchor tube.
Action required: 705 - Other - as specified
Resolved 17 December 2013
Resolution: All repairs completed.
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 21 July 2009 Resolved
-Per 33 CFR 155.1040(a), the Areas of Operation List must be amended to reflect the addition of the Great Lakes COTP zones. -Per 33 CFR 155.1040(j), the geographic-specific appendix for each COTP zone must include notifications to the appropriate state authorities, including boundary states.
Due 21 August 2009
Resolved 14 December 2009
Resolution: vessel HUGH is not authorized for Great Lakes Zones per response from Allied Transportation (see Narrative Statement.)
Documentation › Safety/Response Plans/Programs › Vessel Response Plan
Issued 17 June 2009 Resolved
Submit changes to your Tank Vessel Response Plan (VRP Control #00419) to C.G. Commandant (CG 5431) to relect D-9 Captain of the Port Zones. Provide documentation to COTP Duluth.
Action required: 705 - Other - as specified
Due 17 August 2009
Resolved 22 February 2012
Resolution: Attending Marine Inspector witnessed valid vessel response plan during Annual inspection.
Engineering › Diesel Engine (auxiliary) › Piping (exhaust)
Issued 17 June 2009 Resolved
Install missing exhaust lagging on port cargo pump engine. Provide documentation to [name withheld].
Action required: 705 - Other - as specified
Due 17 June 2009
Resolved 25 June 2009
Resolution: Recieved digital pic of new lagging installed.
Operations/Management › Pollution › Reporting Discharges of Oil
Issued 18 June 2003 Resolved
Place a current copy of the Vessel Response Plan Approval Letter Onboard the vessel and provide a faxed copy of the letter to MSO Wilmington at [phone withheld].
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 18 June 2003
Resolution: VRP Approval Letter Faxed per instructions.
Fire Fighting › Portable CO2 Fire Extinguisher › Condition
Issued 18 June 2003 Resolved
Provide this office a faxed copy of the portable CO2 fire extinguisher inspection report to [phone withheld].
Condition: Unknown
Action required: 705 - Other - as specified
Due 18 June 2003
Resolved 18 June 2003
Resolution: Recieved copy of inspection report.
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 18 June 2003 Resolved
Prove proper operation of port and starboard cargo pump engine emergency shutdowns at next discharge port. LEGACY COMPONENT DESC: Cargo Pump
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 24 June 2003
Resolved 19 June 2003
Resolution: Shutdown system serviced and tested operational.
Engineering › Fuel Oil Service System
Issued 16 July 2002 Resolved
Prove proper operation of fuel oil tank supply valve. LEGACY COMPONENT DESC: Valve
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 October 2002
Resolution: The supply valve for the fuel oil tank was renewed and tested satisfactory.
Electrical › Electric Supply System (service)
Issued 16 July 2002 Resolved
Properly install battery switch at genset. LEGACY COMPONENT DESC: Battery switch
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 17 August 2002
Resolved 9 October 2002
Resolution: New battery switch was installed satisfactory.
Documentation › Certificates/Documents
Issued 12 June 2002 Resolved
Conduct IOPP inspection at next U.S. port of call. LEGACY COMPONENT DESC: IOPP Certificate
Action required: 705 - Other - as specified
Resolved 17 July 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 June 2002 Resolved
Replace flame screen in vent for tank 4-P-C. LEGACY COMPONENT DESC: Flame Screens
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 17 July 2002
Deck/Cargo › Cargo Transfer/Lightering (liquid)
Issued 12 June 2002 Resolved
Prove proper operation of RED cargo transfer light prior to off loading cargo at night. LEGACY COMPONENT DESC: Lighting
Condition: Unknown
Action required: 705 - Other - as specified
Resolved 17 July 2002
Deck/Cargo
Issued 3 May 1999 Resolved
MAKE PROPER REPAIRS OR REPLACE THROTTLE LINKAGE ON PORT CARGO PUMP.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Electrical
Issued 3 May 1999 Resolved
PROVIDE UPDATED CIRCUIT DIRECTORY CARDS FOR ALL PANEL BOARDS THROUGHOUT VESSEL IAW 46 CFR 111.40-10.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Electrical
Issued 3 May 1999 Resolved
PROVIDE ELECTRICAL SAFETY MATTING FOR FRONT OF GENERATOR DISTRIBUTION CONTROL BOARD.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Lifesaving
Issued 3 May 1999 Resolved
PROVIDE COVER FOR PORT LIGHT BETWEEN THE STBD CARGO PUMP ROOM AND DECK STORAGE LOCKER.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Fire Fighting
Issued 3 May 1999 Resolved
PROPERLY INSPECT AND SERVICE ALL REQUIRED PORTABLE FIRE EXTINGUISHERS.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Deck/Cargo
Issued 3 May 1999 Resolved
PROVIDE SERVICE AND INSPECTION REPORT FOR CARGO PUMP ENGINE EMERGENCY SHUTDOWN SYSTEM.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Documentation
Issued 3 May 1999 Resolved
PROVIDE LINE DIAGRAM OF THE VESSEL'S TRANSFER PIPING IAW 33 CFR 155.750.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Documentation
Issued 3 May 1999 Resolved
PROVIDE UPDATED AND APPROVED SOPEP.
Condition: Unknown
Due 3 May 1999
Resolved 3 May 1999
Construction/Loadline
Issued 25 March 1999 Resolved
Make permanent repairs to hole in no. 3 stbd void at lapped section in way of bilge turn aft of frame 18. This requirment is not to be extended beyond25June99.
Condition: Unknown
Due 25 March 1999
Resolved 25 March 1999
Construction/Loadline
Issued 23 February 1999 Resolved
Make permanent repairs to hole in #3 stbd void at lapped section in way of bilge turn aft of frame 18. Provide ABS class report testifying to satisfaction of temporary repair prior to departing Jacksonville, FL. Submit repair proposal to [name withheld] for permanent repairs to above.
Condition: Unknown
Due 23 February 1999
Resolved 23 February 1999
Documentation
Issued 11 March 1998 Resolved
IAW 33 CFR 151.19 VESSEL IS RESTRICTED FROM ENGAGING IN VOYAGES TO PORTS OROFF SHORE TERMINALS UNDER THE JURISDICTION OF OTHER PARTIES TO MARPOL 73/78UNTIL A VALID IOPP CERT IS RECEIVED ONBOARD VESSEL.
Condition: Unknown
Due 11 April 1998
Resolved 23 March 1998
Unknown
Issued 11 June 1997 Resolved
Provide evidence of participation in a chemical testing program
Condition: Unknown
Due 25 June 1997
Resolved 25 June 1997
Construction/Loadline
Issued 14 February 1997 Resolved
Make permanent repairs to wasted plate in upper section of anchor pocket, midships in forward rake, to the satisfaction of ABS.
Condition: Unknown
Due 17 February 1997
Resolved 19 February 1997
Deck/Cargo
Issued 13 March 1996 Resolved
REPAIR THE LEAK IN THE #2 PORT CARGO TANK AT 3RD FRAME AFT OF FORWARD BULKHEAD. REPAIRS TO BE COMPLETED PRIOR TO LOADING CARGO IN THIS TANK.
Condition: Unknown
Due 13 March 1996
Resolved 13 March 1996
Deck/Cargo
Issued 30 May 1995 Resolved
PROCEED TO SAVANNAH, GA TO DISCHARGE CURRENT CARGO. SUBMIT REQUIRED DOCUMENTATION TO COAST GUARD MARINE SAFETY CENTER TO OBTAIN UPDATED L.O.A.C. ALLOWING CARRIAGE OF CSS. AFTER DISCHARGE, NO CSS TO BE CARRIED UNTIL LOAC IS UPDATED BY MARINE SAFETY CENTER.
Condition: Unknown
Due 15 June 1995
Resolved 16 June 1995
Deck/Cargo
Issued 28 June 1991 Resolved
REPAIR BRAKE AND DEMOSTRATE PROPER OPERATION OF ANCHOR WINDLASS.
Condition: Unknown
Due 28 June 1991
Resolved 28 June 1991
Construction/Loadline
Issued 24 October 1990 Resolved
MAKE PERMANENT REPAIRS TO THE FWD RAKE CENTERLINE BLKHD FROM THE AFT BLKHD TO APPROX 7' FWD IN WAY OF THE BOTTOM PLATING TO THE SATISFACTION OF THE COGNIZANT [name withheld] 30NOV91
Condition: Unknown
Due 24 October 1990
Resolved 24 October 1990
Deck/Cargo
Issued 24 October 1990 Resolved
REPLACE BRONZE/BRASS P/V VALVE WEIGHTS FOR #4CP CARGO TANK W/A COMPATIBLE MATERIAL FOR THE CARRIAGE OF STYRENE TO THE SATISFACTION OF THE COGNIZANT [name withheld] 26NOV90
Condition: Unknown
Due 24 October 1990
Resolved 24 October 1990
Construction/Loadline
Issued 3 October 1988 Resolved
MAKE VESSEL'S UNDERWATER PORTION OF HULL AVAILABLE FOR DAMAGE SURVEY BY MARINE INSPECTOR.
Condition: Unknown
Due 3 October 1988
Resolved 3 October 1988
Construction/Loadline
Issued 3 October 1988 Resolved
MAKE NO. 3 STBD CARGO TANK GAS-FREE FOR DAMAGE SURVEY BY MARINE INSPECTOR.
Condition: Unknown
Due 3 October 1988
Resolved 3 October 1988
Deck/Cargo
Issued 10 July 1987 Resolved
PROVE COMPLIANCE WITH STRIPPING QUANTITIES OF 46 CFR 153.481 OR PROVIDE RESTRICTED VOYAGE WAIVER ALLOWED BY 46 CFR 153.483.
Condition: Unknown
Due 10 July 1987
Resolved 10 July 1987
Deck/Cargo
Issued 10 July 1987 Resolved
INSTALL AND PROVE OPERATION OF HIGH LEVEL ALARMS REQUIRED BY 46 CFR 153.409
Condition: Unknown
Due 10 July 1987
Resolved 10 July 1987
Construction/Loadline
Issued 27 February 1985 Resolved
MAKE PERMANENT REPAIR TO #2 OUTBOARD CARGO TANK. NO CARGO SHALL BE CARRIED UNTIL REPAIRS ARE MADE.
Condition: Unknown
Due 27 February 1985
Resolved 27 February 1985
Construction/Loadline
Issued 27 February 1985 Resolved
MAKE AVAILABLE FOR INTERNAL INSPECTION ALL COFFERDAMS FOWARD AND AFT OF #2 AND #4 CARGO TANKS. NO CARGO SHALL BE CARRIED UNTIL THIS ITEM IS CLEARED.
Condition: Unknown
Due 27 February 1985
Resolved 27 February 1985
Construction/Loadline
Issued 27 February 1985 Resolved
MAKE PERMANENT REPAIR TO THE VOID BENEATH THE PORT GENERATOR AND PUMP ROOM.
Condition: Unknown
Due 27 February 1985
Resolved 27 February 1985
Deck/Cargo
Issued 26 November 1984 Resolved
REPAIR TO THE SATISFACTION OF THE COGNIZANT OCMI THE AFT AND CAPSTAN HYDRAULIC CONTROL PUMP.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984
Deck/Cargo
Issued 26 November 1984 Resolved
REPAIR TO THE SATISFACTION OF THE COGNIZANT OCMI THE PORT DEEP WELL CARGO PUMP.
Condition: Unknown
Due 26 November 1984
Resolved 26 November 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.