Records from 2016 to 2018. Most recent: inspection, 21 August 2018.
Inspection history · 9
21 August 2018
Deficiency Check · Administrative Inspection
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6518655
13 August 2018
Ballast Water Examination · PII Safety Exam · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6510161
18 June 2017
ISPS II Exam · Ballast Water Examination · PII Safety Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6179175
23 December 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6061858
18 October 2016
PII Safety Exam · ISPS III Exam · Ballast Water Examination
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 6024540
3 August 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5961660
7 July 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5932384
24 June 2016
Administrative Inspection
Administrative · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5917731
22 March 2016
PII Safety Exam · Ballast Water Examination · ISPS II Exam
Physical examination · Sector Delaware Bay · USCG East District (CGD-E) · Activity 5838157
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 13 August 2018
Resolved
All electrical apparatus shall be so constructed as to not cause injury when handled or touched in the normal manner. Stbd side lifeboat electric control wiring protective sheathing is damaged. -74 SOLAS (04 Cons) II-1/45.1.3
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 August 2018
Resolved 21 August 2018
Resolution: Vessel submitted class report to clear def. See attached.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 13 August 2018
Resolved
The condition of the ship and its equipment shall be maintained to conform with the provisions of the present regulations to ensure the ship remains fit to proceed to sea without danger to the ship or persons. Air compressor is not working under normal parameters requiring additional cooling via portable fan. -74 SOLAS (14 Cons) I/11
Action required: 50 - Rectify deficiencies w/in 30 days
Due 13 September 2018
Resolved 21 August 2018
Resolution: Vessel submitted class report to clear def. See attached.
Lifesaving › Lifeboat › Propeller
Issued 22 March 2016
Resolved
0610-Before the ship leaves port and at all times during the voyage all life-saving appliances shall be in working order and ready for immediate use. The starboard side lifeboat propeller rubs and vibrates against rudder during operation. 74SOLAS(14)III/20.2
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2016
Resolved 23 March 2016
Resolution: Lifeboat was repaired, see attached class report.
Accommodation/Occupational Safety › Occupational Safety › Deck Rail
Issued 22 March 2016
Resolved
1299-Satisfactory means (in the form of guard rails, life lines, gangways, or underdeck passages etc.) shall be provided for the protection of the crew in getting to and from their quarters, the machinery space, and all other parts used in the necessary work of the ship. 2 broken handrails, 1 on port side and 1 on starboard side, found. ICLL(66)Reg 25(4)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 5 April 2016
Resolved 23 March 2016
Resolution: Handrails were repaired. See attached class report.
Electrical › Electrical Distribution System (service) › Wiring
Issued 22 March 2016
Resolved
0950-Where cables which are installed in hazardous areas introduce the risk of fire or explosion in the event of an electrical fault in such areas, special precautions against such risks shall be taken to the satisfaction of the Administration. In the engine room next the purifiers, there is a "dead-end" wire for an unused exhaust fan. 74SOLAS(04)II-1/45.5.4
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 22 March 2016
Resolved 23 March 2016
Resolution: Wire was removed to the satisfaction of class. See attached class report.