Records from 1981 to 2004. Most recent: inspection, 10 August 2004.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 45
10 August 2004
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2161657
20 May 2004
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 2072745
29 January 2003
COI Inspection
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1739446
28 January 2003
Hull Examination
Physical examination · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1736956
15 February 2002
Administrative Inspection
Administrative · Marine Safety Unit Saint Thomas · USCG Southeast District (CGD-SE) · Activity 1739412
13 April 2001
Type not recorded
No type recorded · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1376538
30 March 2001
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1403332
12 February 1999
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1469569
29 January 1999
Type not recorded
No type recorded · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 151030
17 September 1998
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1423074
6 February 1998
Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1396862
10 January 1997
COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1452243
11 September 1996
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1385817
12 January 1996
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1402167
13 January 1995
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1419359
12 January 1995
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 212082
8 September 1994
Hull Examination
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1411019
12 January 1994
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1447321
29 April 1993
Damage Survey · Examination of Repairs
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1148373
28 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 903
8 April 1993
Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 838655
14 January 1993
COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1468287
1 October 1992
Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1243912
10 September 1992
Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1458969
7 February 1992
Deficiency Check
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 951766
21 January 1992
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1261379
20 December 1990
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1224523
20 June 1990
COI Inspection · Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1212557
11 January 1990
Damage Survey
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 915664
17 August 1989
COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 896682
12 September 1988
Hull Examination · COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040626
23 April 1988
Drydock Extension
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1341633
15 October 1987
COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1323114
24 October 1986
COI Inspection · Credit Drydock
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1314113
1 October 1986
COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1017397
1 October 1986
COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1019809
26 September 1986
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1312729
3 October 1985
COI Inspection · Credit Drydock
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1294838
10 April 1985
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1290318
4 October 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975402
27 September 1984
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 975400
13 October 1983
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1274011
19 October 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969878
6 April 1982
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1271793
22 October 1981
Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 969509
Documentation › Certificates/Documents › International Tonnage Certificate
Issued 10 August 2004
No resolution recorded
OBTAIN INTERNATIONAL TONNAGE CERTIFICATE.
Action required: 705 - Other - as specified
Due 10 September 2004 — due date passed with no resolution recorded
Documentation › Safety Management System
Issued 29 January 2003
Resolved
Revise the company's safety management manual to reflect actual management structure, daily checkoff sheet and vessel maintenance.
Due 28 February 2003
Resolved 29 January 2003
Lifesaving › Buoyant Apparatus
Issued 29 January 2003
Resolved
Repair the cracks in the life float.
Due 28 February 2003
Resolved 29 January 2003
Lifesaving › Lifejacket/PFD (General) › Storage
Issued 29 January 2003
Resolved
Properly stow and stencil all child size lifejackets.
Due 28 February 2003
Resolved 29 January 2003
Fire Fighting › Fire Pumps
Issued 29 January 2003
Resolved
Prove proper operation of the engine driven fire pump.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2003
Fire Fighting › Fire Main › Condition
Issued 29 January 2003
Resolved
Renew the holed fire main piping on the port deck standpipe.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2003
Stability › Watertight Integrity
Issued 29 January 2003
Resolved
Provide a clamp for the power supply on the watertight door alarm.
Due 28 February 2003
Resolved 29 January 2003
Stability › Watertight Integrity
Issued 29 January 2003
Resolved
Make watertight the penetration in the forward engine room bulkhead on the starboard side.
Due 28 February 2003
Resolved 29 January 2003
Operations/Management › Drills/Instruction
Issued 29 January 2003
Resolved
Conduct crew proficiency drills; man overboard, fire and abandon ship.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 January 2003
Engineering › Bilge Water Management System › Manifold
Issued 28 January 2003
Resolved
Properly label all bilge manifold suction and discharge valves.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 January 2003
Stability › Watertight Integrity
Issued 28 January 2003
Resolved
Properly mount all watertight door alarm sensors.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 January 2003
Electrical › Lighting (service) › Lighting Fixture
Issued 28 January 2003
Resolved
Provide lamp covers for all exposed lights in the steering compartment.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 January 2003
Stability › Watertight Integrity
Issued 28 January 2003
Resolved
Complete the welding on both sides of the newly installed lazarette door closure.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 28 January 2003
Construction/Loadline
Issued 30 March 2001
Resolved
PRIOR TO VESSEL CERTIFICATION: Provide USCG approved plans for main deck seating and canopy additon to the satisfaction of the attending marine inspector. Provide updated stability letter reflecting alteration.
Condition: Unknown
Due 30 April 2001
Resolved 28 January 2003
Lifesaving
Issued 12 February 1999
Resolved
Properly mark distress signal container.
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Accommodation/Occupational Safety
Issued 12 February 1999
Resolved
Properly mark generator room exit.
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Lifesaving
Issued 12 February 1999
Resolved
Shorten lifebuoy waterlight line to length required by 46 CFR 180.70(d)(2).
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Lifesaving
Issued 12 February 1999
Resolved
Replace lifebuoy waterlight battery.
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Navigation
Issued 12 February 1999
Resolved
Properly install correct all-around lantern and base to meet requirements of 46 CFR 183.420.
Condition: Unknown
Due 26 February 1999
Resolved 26 February 1999
Construction/Loadline
Issued 6 February 1998
Resolved
MAKE REAPAIR TO FRACTURE IN WELD LOCATED IN PORT GENERATOR EXHAUST AT DOUBLER PLATE IN SIDESHELL.
Condition: Unknown
Due 10 February 1998
Resolved 19 February 1998
Construction/Loadline
Issued 6 February 1998
Resolved
MAKE REPAIRS TO FRACTURES IN WELDS LOCATED IN THE FORE PEAK TANK ON BOTH PORT AND STARBOARD JUNCTIONS OF #3 VERTICAL SIDE CORD AND THE #1 SIDE LONG.
Condition: Unknown
Due 10 February 1998
Resolved 19 February 1998
Construction/Loadline
Issued 6 February 1998
Resolved
MAKE REPAIR TO FRACTURED WELD ON AFT PORT BITTS. (FRACTURED WELD LOCATED INTHE GENERATOR ROOM WHERE BITTS ARE ATTACHED TO BACKING PLATE.) CAUSE OF FRACTURE DETERMINED TO BE INCOMPLETE FUSION OF WELD TO BACKING PLATE.
Condition: Unknown
Due 10 February 1998
Resolved 19 February 1998
Documentation
Issued 13 January 1995
Resolved
PROVIDE ONBOARD VALID FCC RADIOTELEPHONY SAFETY CERTIFICATE.
Condition: Unknown
Due 13 January 1995
Resolved 13 January 1995
Documentation
Issued 21 January 1992
Resolved
PROVIDE REVISED STABILITY CALCULATIONS OR DOCUMENTED EVIDENCE SHOWING TOTALNUMBER OF PEOPLE CARRIED FOR DETERMINING SATISFACTORY STABILITY IN SERVICE,OR MAKE VESSEL AVAILABLE FOR SIMP. STABILITY TEST IAW 46CFR170.120(B) AND 170.160(B).
Condition: Unknown
Due 18 February 1992
Resolved 18 February 1992
Navigation
Issued 24 October 1986
Resolved
UHF DOES NOT TRANSMIT PROPERLY.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Accommodation/Occupational Safety
Issued 24 October 1986
Resolved
REPAIR VENT FOR GALLEY STOVE.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Construction/Loadline
Issued 24 October 1986
Resolved
REPAIR BROKEN WELDS ON PORT AND STBD SIDE OF TRANSOM WHERE GUSSETS CONNECT.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Accommodation/Occupational Safety
Issued 24 October 1986
Resolved
PROVIDE GUARD FOR MACHINERY SPACE FAN.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Engineering
Issued 24 October 1986
Resolved
AFT FUEL STORAGE TANK FRACTURE ABOUT 1.5 INCHES LONG MAKE PERMENANT REPAIRS
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Electrical
Issued 24 October 1986
Resolved
GALLEY PANEL BOX NEEDS PLATE TO COVER WIRES.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Construction/Loadline
Issued 24 October 1986
Resolved
PROVIDE APPROVED MSD.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Navigation
Issued 24 October 1986
Resolved
PORT AIR RECIEVER HAS POSSIBLE FRACTURE.HYDRO TO 250 P.S.I. ALSO TEST RELIEF VALVE ON PORT AIR RECIEVER.
Condition: Unknown
Due 24 October 1986
Resolved 24 October 1986
Construction/Loadline
Issued 27 September 1984
Resolved
REPAIR DAMAGE TO CARGO DECK PLATING AND ASSOCIATED INTERNAL MEMBERS RESULTING FROM WIRE SPOOL DROPPING ON DECK.
Condition: Unknown
Due 27 September 1984
Resolved 27 September 1984