Records from 1999 to 2026. Most recent: inspection, 7 January 2026.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 26
7 January 2026
Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8292037
26 February 2025
Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 8085360
14 February 2024
Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7866093
17 February 2023
Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7647571
24 February 2022
Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7403915
3 March 2021
Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 7149003
10 March 2020
Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6921152
26 April 2018
DAPI Audit · Uninspected Passenger Vessel
Physical examination · Detached Duty Office Myrtle Beach · USCG Southeast District (CGD-SE) · Activity 6416878
1 May 2012
COI Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4298547
13 May 2009
Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3468853
19 June 2008
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3239176
14 December 2007
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3115920
5 July 2007
Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2999572
15 August 2005
Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2460813
24 June 2004
Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2125038
16 June 2004
Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2100585
21 May 2003
Hull Examination · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1803821
7 September 2002
Type not recorded
No type recorded · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1749319
24 June 2002
Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1646941
18 June 2002
Hull Examination · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1632477
23 May 2001
Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1393705
10 August 2000
Deficiency Check
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821495
28 July 2000
Re-Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 821232
23 July 1999
COI Inspection
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1104905
20 July 1999
COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1442898
21 April 1999
Hull Examination · Initial Certification · Initial Construction-Excluding Oversight
Physical examination · MSO SAN DIEGO · USCG Southwest District (CGD-SW) · Activity 1397162
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 14 February 2024
Resolved
Surround Line frayed and disintegrating
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 15 February 2024
Resolved 14 February 2024
Resolution: Frayed line replaced
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 10 March 2020
Resolved
Missing Anchor Light
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 April 2020
Resolved 3 March 2021
Lifesaving › Lifejacket/PFD (Type I) › Lights
Issued 26 April 2018
Resolved
Type I PFD's not equipped with water lights.
Action required: 705 - Other - as specified
Resolved 3 March 2021
Navigation › Piloting/Steering › Marine Charts
Issued 26 April 2018
Resolved
Vessel not equipped with navigational publications for areas transited.
Action required: 705 - Other - as specified
Resolved 3 March 2021
Lifesaving › Lifejacket/PFD (Type I) › Retroreflective Material
Issued 26 April 2018
Resolved
Type I PFD's retro-reflective markings worn/required replacement.
Action required: 10 - Deficiency Rectified
Resolved 26 April 2018
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Serviceable
Issued 26 April 2018
Resolved
Ring life buoy missing retro-reflective markings.
Action required: 10 - Deficiency Rectified
Resolved 26 April 2018
Resolution: Corrected on the spot
Lifesaving › Hand Flares › Quantity
Issued 26 April 2018
Resolved
Vessel not equipped with proper type/qty of visual distress signals.
Action required: 705 - Other - as specified
Resolved 3 March 2021
Navigation › Collision/Grounding Avoidance › Navigation Lights
Issued 26 April 2018
Resolved
Navigational side lights were extinguished/inoperable at time of examination.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 3 March 2021
09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 26 April 2018
Resolved
Emergency instructions not posted/carried on board.
Action required: 705 - Other - as specified
Resolved 3 March 2021
Operations/Management › Drills/Instruction › Abandon Ship
Issued 19 June 2008
Resolved
Provide documentation for abandon ship drill.
Due 24 August 2008
Resolved 24 August 2008
Documentation › Certificates/Documents › FCC SSL
Issued 19 June 2008
Resolved
Provide documentation for radio operator permit.
Due 24 August 2008
Resolved 24 August 2008
Communications › Radio Communications › EPIRB
Issued 19 June 2008
Resolved
Provide current battery for EPIRB.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 24 July 2008
Construction/Loadline › Structures › Superstructure
Issued 15 August 2005
Resolved
Repair as original, hull delamination in way of inside forepeak storage where outermost FRP layer is starting to separate. All repairs are to be completed to the satisfaction of the attending marine inspector.
Due 15 October 2005
Resolved 15 August 2005
Construction/Loadline › Hull › Stiffener
Issued 15 August 2005
Resolved
Repair or renew as original, small cracks in side shell stiffeners. All repairs shall be completed to the satisfaction of the attending marine inspector.
Due 15 October 2005
Resolved 15 August 2005
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 June 2004
Resolved
Repair Gusset Tab fractures under seats.
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 24 June 2004
Resolution: Repaired Gussets.
Construction/Loadline › Structures › Transverse Bulkhead
Issued 16 June 2004
Resolved
Repair Fwd nontight bulkhead Tabs.
Action required: 705 - Other - as specified
Due 24 June 2004
Resolved 24 June 2004
Resolution: Reglassed tabs.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 June 2004
Resolved
Install Machinery Guards on winch driveshaft IAW 46 CFR 177.960
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 24 June 2004
Resolution: Guards installed.
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Condition
Issued 16 June 2004
Resolved
Renew fire extinguishers IAW 46 CFR 176.810.
Action required: 701 - Prior to carriage of passengers/cargo
Due 17 July 2004
Resolved 24 June 2004
Resolution: Extinguishers renewed.
Engineering › Bilge Water Management System › Pump
Issued 16 June 2004
Resolved
Install approved Bilge pumps IAW 46 CFR 176.804
Due 17 July 2004
Resolved 24 June 2004
Resolution: Bilge pumps installed.
Electrical › Electrical Distribution System (service) › Cable
Issued 16 June 2004
Resolved
Remove Dead end cable throughout vessel.
Action required: 705 - Other - as specified
Due 17 July 2004
Resolved 24 June 2004
Resolution: Dead end cables removed.
Engineering
Issued 10 August 2000
Resolved
INSTALL MACHINERY GUARDS ON MDE'S AND S/S GENERATOR AS REQUIRED BY 46 CFR 176.960.
Condition: Unknown
Due 10 September 2000
Resolved 22 September 2000
Lifesaving
Issued 28 July 2000
Resolved
RE-MARK EMERGENCY INSTRUCTIONS LEGIBLY IAW 46 CFR 185.510.
Condition: Unknown
Due 28 July 2000
Resolved 28 July 2000
Engineering
Issued 28 July 2000
Resolved
VESSEL PROHIBITED FROM FILLING, OR DRAWING FUEL FROM, PORT FUEL TANK UNTIL EMERGENCY SHUT OFF VALVE PULL/CABLE REPAIRED OR REPLACED.
Condition: Unknown
Due 28 July 2000
Resolved 28 July 2000
Construction/Loadline
Issued 28 July 2000
Resolved
SECURE BILGE HIGH LEVEL ALARM FLOAT SWITCH AND BILGE PUMP IN ENGINE ROOM.
Condition: Unknown
Due 28 July 2000
Resolved 28 July 2000
Fire Fighting
Issued 21 April 1999
Resolved
CONDUCT OPERATIONAL TEST OF INSTALLED PRE-ENGINEERED FIXED FIRE FIGHTING SYSTEM.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Navigation
Issued 21 April 1999
Resolved
PROVIDE NAVIGATIONAL EQUIPMENT REQUIRED IN THE AREA OF OPERATION,
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Navigation
Issued 21 April 1999
Resolved
PROVIDE RADIO FOR SHIP TO SHORE AND/OR SHIP TO SHIP COMMUNICATION REQUIRED IN AREA OF OPERATION.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Documentation
Issued 21 April 1999
Resolved
PROVIDE CERTIFICATE OF DOCUMENTATION OR STATE REGISTRATION WHICH EVER ONE APPLIES.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Documentation
Issued 21 April 1999
Resolved
CONDUCT REQUIRED DRILLS.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Engineering
Issued 21 April 1999
Resolved
POST PLACARD REQUIRING 5 MINUTES OPERATION OF POWER BLOWER PRIOR TO STARTING MAIN ENGINE.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Fire Fighting
Issued 21 April 1999
Resolved
INSTALL PROPER SIZE CG APPROVED PRE-ENGINEERED FIRE FIGHTING SYSTEM'S AGENTBOTTLE (PRESENTLY INSTALLED BOTTLE INCORRECT AMOUNT FOR THE SIZE OF SPACE PROTECTED).
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Engineering
Issued 21 April 1999
Resolved
PROVE PROPER OPERATION OF GASOLINE FUME DETECTOR
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Documentation
Issued 21 April 1999
Resolved
PROVIDE CG LICENSED OPERATOR.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Documentation
Issued 21 April 1999
Resolved
PROVIDE PROOF OF COMPLIANCE WITH DRUG TESTING REGULATIONS.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Navigation
Issued 21 April 1999
Resolved
PROVIDE PUBLICATIONS AND REQUIRED CHARTS OF THE AREA OPERATED.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Lifesaving
Issued 21 April 1999
Resolved
PROVIDE LIFERING BUOY WITH WATER LIGHTS AND LINES ATTACHED.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Navigation
Issued 21 April 1999
Resolved
TEST ALL NAVIGATIONAL LIGHTS.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999
Engineering
Issued 21 April 1999
Resolved
PROVE PROPER OPERATION OF MAIN PROPULSION ENGINE.
Condition: Unknown
Due 21 April 1999
Resolved 21 April 1999