MAURY USCG vessel records Sign in
← All vessels

CAPT. PAUL

CAPT. PAUL is a 1977 passenger vessel (inspected). The Coast Guard has recorded 95 inspections since 1980, most recently in January 2026, along with 104 deficiencies, 1 operational control and 2 casualty investigations between 2010 and 2011.

Records from 1980 to 2026. Most recent: inspection, 15 January 2026.

Built
1977
Last inspected
15 January 2026
Documentation
Case Pending · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WDG8167
Flag
UNITED STATES
367574680
Maury page id
psix-49405

Inspections, by type

…with no type recorded18
Years with a record 44 calendar years (1980–2026)
The 95 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)56.3 ft × 18.6 ft × 7.5 ft
Registered tonnagegross 61 / net 41
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderA-1 MARINE INC · PANAMA CITY, FL, UNITED STATES · built 1977
Hull materialFRP (Fiberglass)
PropulsionDiesel Reduction
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portPORT ARANSAS, TX
Trade endorsementsCoastwise, unrestricted
DocumentationCase Pending · issued 30 June 2004
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it61 - Regulatory (Subpart C or D), Gross Ton
41 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WDG8167MMSI 367574680 · active · compulsorily equipped · granted 3 May 2023, expires 15 May 2033
WDD7963MMSI 366822070 · expired · compulsorily equipped · granted 9 June 2007, cancelled 12 August 2017
WBD9282MMSI 366822070 · expired · compulsorily equipped · granted 9 December 1996, cancelled 5 May 2007
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

Inspection history · 95

15 January 2026 Administrative Inspection · Drydock Exam · Vessel Attendance · Internal Structural Exam · Examination of Repairs
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8297124
10 December 2025 Administrative Inspection · COI Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8281635
28 February 2025 Deficiency Check · Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 8086252
26 February 2024 Administrative Inspection · Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7870131
6 December 2023 Internal Structural Exam · In-Service Inspection · Drydock Exam · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7834699
16 November 2023 In-Service Inspection · Deficiency Check · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7826155
15 May 2023 In-Service Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7689235
17 January 2023 Annual Inspection · DAPI Audit · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7622723
25 February 2022 Administrative Inspection · Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7401980
11 February 2022 Drydock Exam · Internal Structural Exam
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7361997
25 January 2021 Administrative Inspection · COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 7130478
27 March 2020 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6932213
29 January 2020 Internal Structural Exam · Hull Examination · Drydock Exam · In-Service Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6898621
15 April 2019 Annual Inspection · Administrative Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6662712
16 April 2018 Annual Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6392289
30 December 2017 Administrative Inspection · Hull Examination · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6327841
10 April 2017 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 6121156
1 February 2016 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5801459
13 January 2016 Internal Structural Exam · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 5796142
21 February 2012 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4246508
12 December 2011 Hull Examination · Internal Structural Exam · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 4181546
17 February 2011 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3947572
27 January 2011 COI Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3934125
12 January 2010 Deficiency Check · Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3662302
8 January 2010 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3660756
6 February 2009 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3413407
27 February 2008 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3150198
15 February 2008 Administrative Inspection
Administrative · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3148206
11 December 2007 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 3090045
15 March 2007 Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2888478
28 February 2007 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2878854
8 February 2006 COI Inspection · Deficiency Check
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2576878
11 January 2006 Type not recorded
No type recorded · USCGC STEELHEAD (WPB 87324) · USCG East District (CGD-E) · Activity 2632102
13 December 2005 Hull Examination
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2549988
2 June 2005 Annual Inspection
Physical examination · Sector Corpus Christi · USCG Heartland District (CGD-H) · Activity 2376680
27 August 2004 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2178478
15 June 2004 Annual Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2098379
6 April 2004 Deficiency Check · Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 2038607
22 May 2003 Annual Inspection · Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1798880
3 June 2002 Administrative Inspection
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1625516
2 May 2002 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1611787
9 April 2002 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1602977
14 July 2001 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1521946
24 April 2001 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1062522
13 April 2001 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1463650
9 September 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 822320
8 August 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 821747
7 August 2000 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 145902
24 April 2000 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1048800
12 April 2000 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1455843
4 April 2000 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1440277
19 May 1999 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 798573
15 April 1999 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1469259
25 February 1999 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1510162
19 February 1999 Type not recorded
No type recorded · Station Port Aransas · USCG Heartland District (CGD-H) · Activity 1510156
4 May 1998 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1124861
15 April 1998 Deficiency Check · COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1421489
2 April 1998 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1416682
10 April 1997 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1460944
9 April 1996 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1359081
3 April 1996 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1459983
13 April 1995 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1407463
11 April 1994 Deficiency Check · Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1465139
28 March 1994 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1419242
14 May 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 838483
13 May 1993 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 835200
11 May 1993 Plan Review "T" Boat
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1145973
13 April 1993 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1152141
12 February 1993 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1259102
16 April 1992 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1440623
24 March 1992 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 956758
24 February 1992 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 950261
23 August 1991 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 655157
25 June 1991 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 915397
16 May 1991 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 913655
25 June 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 930846
7 June 1990 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1214097
22 May 1990 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 910059
17 May 1990 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1219376
18 May 1989 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1207656
28 June 1988 Administrative
Administrative · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 893040
1 June 1988 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 886703
10 May 1988 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1038713
2 May 1988 Hull Examination
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1036298
19 May 1987 COI Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1331536
17 June 1986 Deficiency Check
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1301220
25 April 1986 Re-Inspection
Physical examination · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1308417
24 March 1986 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 1303199
1 May 1985 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 982780
8 May 1984 Type not recorded
No type recorded · MSO Corpus Christi · USCG Heartland District (CGD-H) · Activity 974169
9 May 1983 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 971761
28 December 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 971210
25 February 1982 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 973814
8 December 1981 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1283284
28 October 1980 Type not recorded
No type recorded · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1272846

Deficiency record · 104

01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 14 January 2026 Resolved
The master or managing operator shall instruct each crew member, at least once every three months, as to the duties that the crew member is expected to perform in an emergency. Training and drills have not been logged from MAR2025-JAN2026. 46CFR185.420(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 28 January 2026
Resolution: Operator completed logs for January and set instructions for monthly requirement.
11 - Life Saving Appliances › N/A - No Subsystem › Operation of Life Saving Appliances
Issued 14 January 2026 Resolved
Each EPIRB must be tested monthly. Crew members were unfamiliar on how to test or use the vessel's EPIRB. 46CFR185.728(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 28 January 2026
Resolution: Crew members were properly trained and EPIRB has been tested and logged.
09 - Working and Living Conditions › 092 - Working Conditions › Guards - fencing around dangerous machinery parts
Issued 14 January 2026 Resolved
Suitable covers or guards shall be installed in way of all exposed hazardous places such as gears and machinery. Vessel is missing guards near bilge pump PTO motor and generator pulley. 46CFR177.35-15(a)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 28 January 2026
Resolution: Fabricated machinery guards and installed properly.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Bilge pumping arrangements
Issued 14 January 2026 Resolved
Bilge suction lines shall be fitted with suitable strainers. Bilge uptake suction screens are wasted throughout the vessel. 46CFR182.25-5(b)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 28 January 2026
Resolution: Fabricated screens and recommended replacing at next DD.
10 - Safety of Navigation › N/A - No Subsystem › Electronic charts (ECDIS)
Issued 14 January 2026 Resolved
As appropriate for the intended voyage, a vessel must carry adequate and up-to-date charts of large enough scale to make safe navigation possible. Garmin electronic charts have not been updated to latest software version. 46CFR184.420(a)(1)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 28 January 2026
Resolved 28 January 2026
Resolution: Most current version of electronic charts uploaded.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for radio personnel
Issued 14 January 2026 Resolved
Each ship transporting more than six passengers for hire must carry a radio operator who meets the following requirements: the radio operator must hold a marine radio operator permit or higher class license. Current captain does not hold a valid FCC VHF radio operators permit. 47CFR80.159(e)(1)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2026
Resolved 20 February 2026
Resolution: Captain has obtained his operators permit.
01 - Certificates & Documentation › 012 - Crew Certificates › Certificate for medical care
Issued 14 January 2026 Resolved
The Coast Guard will issue a medical certificate to a mariner meeting the medical and physical standards for merchant mariners. Medical certificates issued to all other mariners will be issued for a maximum period of 5 years. Captain does not have a valid medical certificate. 46CFR10.301(b)(2)
Condition: Invalid
Action required: 50 - Rectify deficiencies w/in 30 days
Due 14 February 2026
Resolved 28 January 2026
Resolution: Captain provided Valid medical certificate.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 14 January 2026 Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be ready for inspections of the hull structure. Forward engine room bulkhead has multiple cable penetrations filled with foam that is not water tight. Operator shall assess all wooden framing throughout vessel structure that is showing signs of delignification. 46CFR176.802(a)
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 9 March 2026
Resolution: Vessel replaced multiple beams that had severe delignification.
05 - Radio Communications › N/A - No Subsystem › MF Radio installation
Issued 9 April 2025 Resolved
Vessels subject to Part III of Title III of the Communications Act must be equipped as follows: Vessels operated beyond the 20 nautical miles limitation specified in paragraph (a)(1) of this section, but not more than 100 nautical miles from nearest land, must be equipped with a MF-DSC frequency transmitter. Vessel has SSB without DSC functionality. Rectify to the satisfaction of the attending Marine Inspector. Vessel is limited to a Coastwise route while carrying passengers until rectified. 47 CFR 80.905(a)(2)
Condition: Invalid
Action required: 705 - Other - as specified
Resolved 23 May 2025
Resolution: Vessel has requested to change their route to Coastwise in lieu of obtaining MF-DSC radio.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 9 April 2025 Resolved
The general construction of the vessel shall be such as to minimize fire hazardsa insofar as reasonable. There is an open tube with engine start cables running from the E/R to a manned space. The E/R is protected by an automatically activated FM 200 system. Rectify to the satisfaction of the attending Marine Inspector. 46 CFR 177.10-5
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 8 May 2025
Resolution: Marine grade sealant was used to fill in the cable penetration.
10 - Safety of Navigation › N/A - No Subsystem › Nautical publications
Issued 9 April 2025 Resolved
The operator of each self-propelled vessel 12 meters or more in length shall carry, on board and maintain for ready reference, a copy of these rules. The vessel is not carrying a copy of the Navigation Rules. Provide to the satisfaction of the attending Marine Inspector. 33 CFR 83.01(g)
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 25 April 2025
Resolved 8 May 2025
Resolution: Vessel obtained new paper charts.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 April 2024 Resolved
Retroreflective tape on the lifebuoy deteriorated and peeling off.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2024
Resolved 17 April 2024
Resolution: New tape applied to life rings.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 10 April 2024 Resolved
Lifelines on the lifebuoy deteriorated and fraying.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2024
Resolved 17 April 2024
Resolution: Lifelines renewed on life rings.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance and inspections
Issued 10 April 2024 Resolved
Battery for the port forward lifefloat light was expired.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 24 April 2024
Resolved 17 April 2024
Resolution: New batteries were ordered and replaced in the waterlights.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 April 2024 Resolved
U.S. Coast Pilot. U.S. Coast Pilot was not current.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2024
Resolved 15 May 2024
Resolution: Received email with picture of current Coast Pilot on board vessel.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 10 April 2024 Resolved
Coast Guard Light List was not current.
Action required: 50 - Rectify deficiencies w/in 30 days
Due 10 May 2024
Resolved 15 May 2024
Resolution: Received email with picture of current CG Light list on board vessel.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 April 2024 Resolved
02 Child lifejackets' retroflective material was replaced during inspection.
Action required: 10 - Deficiency Rectified
Due 10 April 2024
Resolved 10 April 2024
Resolution: 02 Child lifejackets' retroflective material was replaced during inspection.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 10 April 2024 Resolved
03 life jacket lights for adults and 01 life jacket light for a child were replaced during inspection.
Action required: 10 - Deficiency Rectified
Due 10 April 2024
Resolved 10 April 2024
Resolution: 03 life jacket lights for adults and 01 life jacket light for a child were replaced during inspection.
05 - Radio Communications › N/A - No Subsystem › MF/HF Radio installation
Issued 15 May 2023 Resolved
A vessel must comply with the applicable requirements for any radio and Electronic Position Indicating Radiobeacon (EPIRB) installations, including the requirements for a station license and installation certificates to be issued by the Federal Communications Commission, as set forth in 47 CFR part 80. Vessel did not have MF radio on board for route of <100 nautical miles from shore. Install required radio equipment, obtain new FCC Communications Act Safety Radiotelephone Certificate for newly installed radio equipment, subject to the satisfaction of the attending USCG Marine Inspector. Vessel is restricted to <20 nautical miles from shore until rectified.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 15 June 2023
Resolved 16 November 2023
Resolution: MF/HF Radio installed and tested.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 13 April 2022 Resolved
The individual bilge suction lines shall be led to a central control point or manifold. Each line shall be provided with a stop valve at the control point or manifold and in addition shall be provided with a check valve at some point in the bilge line. All thre submerisible bilge pumps, which are in addition to a fixed bilge system, did not have check valves in the bilge line. Add check valves to the satisfaction of the USCG Marine Inspector. 46CFR182.25-5(c)
Condition: Design Flaw
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 27 April 2022
Resolution: Check valves have been installed on discharge side of Submersible bilge pumps.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 13 April 2022 Resolved
All lights, receptacles, and switches exposed to the weather shall be watertight on vessels operating in salt water. Two fwd lights, the all around light, and port aft speaker had exposed wiring/connections. Seal and repair to the satisfaction of the USCG Marine Inspector. 46CFR183.05-35(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 April 2022
Resolved 27 April 2022
Resolution: Exterior wire connections have been sealed with watertight covers.
Deck/Cargo › Mooring/Anchoring › Winch
Issued 16 April 2018 Resolved
Rigid nonmetallic material possesses characteristics adequate for its intended service and environment. Anchor winch hydraulic lines has perforations in the hose outside material and requires replacement.
Condition: Invalid
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 1 May 2018
Resolution: Vessel Replaced both lines with new ones
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 16 April 2018 Resolved
Suitable covers, guards, or rails shall be installed in way of all exposed and hazardous places. Anchor winch chain gear is exposed and poses a hazardous place.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 1 May 2018
Resolution: Vessel repaired existing machinery guard that was previously damaged.
Fire Fighting › Fire Hoses › Length
Issued 16 April 2018 Resolved
re hose shall not be less than 25 feet and not more than 50 feet in length. Fire hose is 100 feet in length and requires replacement with proper length of hose.
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 1 May 2018
Resolved 1 May 2018
Resolution: Vessel replaced garden style fire hose with a proper length requirement. 50FT
Engineering › Shafting/Propeller Arrangements › Propeller (fixed pitch)
Issued 30 December 2017 Resolved
Both propellers require cleaning/rebuild to specs.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Resolved 14 February 2018
Resolution: Both propellers were cleaned and rebuilt to specs by Marine Propeller Works, Aransas Pass, TX.
Engineering › Shafting/Propeller Arrangements › Propeller Shaft
Issued 30 December 2017 Resolved
Both propeller shafts show signs of uneven wear. Check for straightness and rebuild to specs.
Action required: 705 - Other - as specified
Resolved 14 February 2018
Resolution: both shafts were checked for straightness and rebuilt to specs by Marine Propeller Works, Aransas Pass, TX.
Construction/Loadline › Hull › Stringer
Issued 30 December 2017 Resolved
Delamination noted on stringers in void forward of engine room. Repair delamination of FRP on 2 stringers.
Condition: Improper Installation
Action required: 705 - Other - as specified
Resolved 2 March 2018
Resolution: both stringers repaired with MIL-R-21607E resin.
Construction/Loadline › Structures › Longitudinal Bulkhead
Issued 10 April 2017 Resolved
Fiberglass delaminating from framing in lazarette compartment in way of inboard port longitudinal deck frame where it meets stern also in way of starboard aft corner below deck. Bow anchor pulpit support forum seperated. Vessel does not comply with the structural design requirements. Vessel owner/rep must submit repair proposal.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 9 May 2017
Resolution: Fixed delamination with approved method
Lifesaving › Lifefloat › Painter
Issued 1 February 2016 Resolved
Life float painter/ weak link assembly incorrectly mounted. Painter line ran under mounted cage to weak link connection point enabling proper operation.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 1 February 2016
Resolution: Corrected on the spot.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 1 February 2016 Resolved
Line on life ring bouy incorrectly daisy chained together preventing the abilty to safifactory throw overboard.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 1 February 2016
Resolved 1 February 2016
Resolution: Corrected on spot.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 8 February 2011 Resolved
Replace alcohol testing strips. Vessel may not operate more than 20 miles from a harbor of safe refuge until corrected.
Action required: 705 - Other - as specified
Due 15 February 2011
Resolved 17 February 2011
Resolution: Vessel had new alcohol testing strips.
Electrical › Electrical Distribution System (service) › Wiring
Issued 8 February 2011 Resolved
Install metallic clamps every 2' on wiring in engine room.
Action required: 705 - Other - as specified
Due 15 February 2011
Resolved 17 February 2011
Resolution: Metallic clamps were installed on wiring every 24 inches in engine room.
Documentation › Certificates/Documents › Certificate of Inspection
Issued 8 January 2010 Resolved
VSL overdue hull exam
Action required: 705 - Other - as specified
Due 12 January 2010
Resolved 12 January 2010
Resolution: Completed credit drydock.
Electrical › Electrical Distribution System (service) › Wiring
Issued 28 February 2007 Resolved
Replace wiring to potable water pump port side engine room, install supports every 24 inches
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 7 March 2007
Engineering › Bilge Water Management System › Piping
Issued 28 February 2007 Resolved
Properly secure bilge suction piping in forward engine room to prevent vibration.
Action required: 705 - Other - as specified
Due 28 March 2007
Resolved 7 March 2007
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 8 February 2006 Resolved
Replace metallic fuel line elbow in aft lazarette.
Action required: 705 - Other - as specified
Due 8 March 2006
Resolved 9 February 2006
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 2 June 2005 Resolved
Provide on board first aid kit with approval series #160.01.
Action required: 705 - Other - as specified
Due 9 June 2005
Resolved 3 June 2005
Resolution: Faxed receipt of purchase from Donavan Marine.
Accommodation/Occupational Safety › Occupational Safety
Issued 15 June 2004 Resolved
Mark all emergency exits "Emergency Exit - Keep Clear".
Due 15 July 2004
Resolved 15 June 2004
Construction/Loadline › Hull
Issued 7 April 2004 Resolved
Provide proposal to address excessive moisture and repair to indicated areas in keel and provide plans.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2004
Construction/Loadline › Penetrations
Issued 7 April 2004 Resolved
Remove transducer patch and prepare area for further inspection.
Action required: 17 - Rectify deficiencies prior to departure
Resolved 14 April 2004
Construction/Loadline › Structures › Machinery Space Opening
Issued 7 April 2004 Resolved
Provide proposal to address repair of transverse deck beams forward and aft of engine covers.
Action required: 705 - Other - as specified
Resolved 14 April 2004
Engineering › Steering Gear System
Issued 7 April 2004 Resolved
Provide proposal to address steering gear attachments to keel stringers.
Action required: 705 - Other - as specified
Resolved 14 April 2004
Construction/Loadline › Structures › Door
Issued 7 April 2004 Resolved
Replace exterior dog handle on port side watertight door and make all dogs operable.
Action required: 705 - Other - as specified
Resolved 14 April 2004
Construction/Loadline › Hull
Issued 7 April 2004 Resolved
Clean areas in way of strut connection to hull for further inspection.
Action required: 705 - Other - as specified
Resolved 14 April 2004
Lifesaving › Hand Flares › Quantity
Issued 22 May 2003 Resolved
Obtaine 6 additional flares that comply w/ 46 CFR 160.021 or 160.036. Note 4 other flares exp SEP 03. Prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 22 May 2003
Engineering › Bilge Water Management System
Issued 22 May 2003 Resolved
Bilge Piping: a) provide material data on plastic pipe that shows that piping provides an equal degeree of safety and heat resistivity as teh hull 46 CFR 182.40-1 or B) Install metal valves at all bulkheads or C) install metalic pipe. LEGACY COMPONENT DESC: Piping
Due 22 June 2003
Resolved 30 June 2003
Resolution: Corrected.
Construction/Loadline › Hull
Issued 22 May 2003 Resolved
Install valve at overboard for freezer plate thru hull.
Due 22 June 2003
Resolved 30 June 2003
Resolution: Corrected.
Engineering › Sea-water System (primary cooling)
Issued 22 May 2003 Resolved
Fix lead on port main engine sea water intake LEGACY COMPONENT DESC: Piping
Due 22 June 2003
Resolved 30 June 2003
Resolution: Corrected
Navigation › Piloting/Steering
Issued 22 May 2003 Resolved
Update pubs as required by 46 CFR 184.420 i.e. light list, photo copies acceptable.
Due 22 June 2003
Resolved 30 June 2003
Resolution: Corrected.
Construction/Loadline › Structures
Issued 22 May 2003 Resolved
Provide proposal to meet requirements for hand rails, CG to advise basically 4" spacing of bars, rails or slats.
Due 31 July 2003
Resolved 28 August 2003
Electrical
Issued 9 April 2002 Resolved
Reinstall all missing/wasted/broken bonding system components.
Condition: Improper/Lack of Maintenance
Due 30 April 2002
Resolved 12 April 2002
Engineering › Steering Gear System › Bracket/Clamp
Issued 9 April 2002 Resolved
Replace wasted/loose securing bracket nuts/bolts port side centerline.
Due 30 April 2002
Resolved 12 April 2002
Construction/Loadline › Hull
Issued 9 April 2002 Resolved
Fair and recover cracks in fiberglass skin IWO prow and center first 1/3 of keel.
Due 30 April 2002
Resolved 12 April 2002
Construction/Loadline › Structures › Deck Plating
Issued 9 April 2002 Resolved
Re shim deck beams IWO access hatch to collision compartment. Maintain monthly inspection of beams to verifiy crack not propogating. Notify OCMI if crack grows and submit plan to replace cracked beam(s).
Due 30 April 2002
Resolved 12 April 2002
Deck/Cargo › Mooring/Anchoring
Issued 9 April 2002 Resolved
Reinstall anchor winch in manner that keeps water from leaking through to deck core material. LEGACY COMPONENT DESC: Winch
Condition: Unknown
Due 30 April 2002
Resolved 2 May 2002
Deck/Cargo › Holds/Tanks
Issued 9 April 2002 Resolved
Fumigate collision compartment to exterminate extensive wood mites present.
Condition: Unknown
Due 30 April 2002
Resolved 2 May 2002
Construction/Loadline
Issued 13 April 2001 Resolved
REPAIR CRACK IN FIBERGLASS IN THE FOREPEAK LOCATED ALONG THE PORT SIDE LONGITUDINAL FRAME ADJACENT TO THE COLLISION BULKHEAD.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Electrical
Issued 13 April 2001 Resolved
REMOVE EXCESSIVE ELECTROLYTE AND WATER FROM FORWARD BATTERY BOX IN THE ENGINE ROOM.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Documentation
Issued 13 April 2001 Resolved
PROVIDE UPDATED TRAINING LOG. (LOG ALL DRILLS)
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Navigation
Issued 13 April 2001 Resolved
PROVIDE ADDITIONAL CHART FOR LOCAL OPERATING AREA.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Navigation
Issued 13 April 2001 Resolved
PROVIDE COMPASS LIGHT IAW 46CFR184.402
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Navigation
Issued 13 April 2001 Resolved
PROVIDE PROPER SIZE SHIPS BELL IAW COLREGS ANNEX III 2(b).
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Documentation
Issued 13 April 2001 Resolved
PROVIDE COPY OF FCC SAFETY CERTIFICATE.
Condition: Unknown
Due 23 April 2001
Resolved 23 April 2001
Engineering
Issued 8 August 2000 Resolved
PERMANENTLY AFFIX PORT MDE RAW WATER DISCHARGE LINE TO PREVENT CONTACT_x001C_ WITH PUMP PULLEY ON ENGINE.
Condition: Unknown
Due 7 September 2000
Resolved 11 August 2000
Engineering
Issued 8 August 2000 Resolved
INSTALL "START IN GEAR PROTECTION" IN ACCORDANCE WITH GOOD MARINE PRACTICE AS PER 46 CFR 176.800.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Lifesaving
Issued 8 August 2000 Resolved
INSTALL GUARDS IN FRONT OF BOTH MDE FLYWHEELS.
Condition: Unknown
Due 8 August 2000
Resolved 8 August 2000
Documentation
Issued 8 August 2000 Resolved
PLACE IN WHEEL HOUSE AND ENGINEROOM; STARTING INSTRUCTIONS TO ENSURE BOTH THROTTLE CONTROLS ARE IN NEUTRAL AND MICRO [name withheld] PRIOR TO STARTING ENGINES.
Condition: Unknown
Due 9 August 2000
Resolved 11 August 2000
Engineering
Issued 8 August 2000 Resolved
REPLACE PORT MDE FLYWHEEL PULLEY DUE (CRACKED AND WEARING BELT).
Condition: Unknown
Due 7 September 2000
Resolved 11 August 2000
Construction/Loadline
Issued 12 April 2000 Resolved
CLEAN AND PREPARE FOR INSPECTION BY A MARINE INSPECTOR ENGINE ROOM FORWARD AND AFT MAIN DECK SUPPORTS.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Engineering
Issued 12 April 2000 Resolved
REPAIR TO PROPER OPERATION FUEL SHUT-OFF VALVE AND REACH ROD.
Condition: Unknown
Due 12 April 2000
Resolved 12 April 2000
Lifesaving
Issued 15 April 1999 Resolved
CONDUCT FIRE, MAN OVERBOARD AND ABANDON SHIP DRILL AND PROVE VSL IS ARRANGED IAW 46CFR180.210(a)(1)(2)(3) TO THE SATISFACTION OF ATTENDING USCGMARINE INSPECTOR.
Condition: Unknown
Due 15 April 1999
Resolved 15 April 1999
Lifesaving
Issued 15 April 1998 Resolved
ATTACH WATER LIGHT TO RING BOUY VIA METAL CLIP AT END OF LANYARD.
Condition: Unknown
Due 29 April 1998
Resolved 17 April 1998
Construction/Loadline
Issued 15 April 1998 Resolved
PROVIDE BILGE HIGH LEVEL ALARMS (AUDIBLE AND VISUAL) IAW 46 CFR 182.115 (d) & 182.530 PRIOR TO MARCH 11, 1999
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Fire Fighting
Issued 15 April 1998 Resolved
PROVIDE FIXED GAS FIRE EXTINGUISHING SYSTEM IAW 46 CFR 181.115 (c), & 181.400 PRIOR TO MARCH 11, 1999.
Condition: Unknown
Due 15 April 1998
Resolved 15 April 1998
Electrical
Issued 15 April 1998 Resolved
PROVIDE PROTECTIVE GLOBE FOR LIGHT IN LAZARETTE PORT SIDE/AFT AND REATTACH LIGHT FIXTURE TO BASE.
Condition: Unknown
Due 29 April 1998
Resolved 17 April 1998
Lifesaving
Issued 10 April 1997 Resolved
VESSEL'S WATERTIGHT HATCHES NOT PROPERLY MARKED, 46 CFR 185.610.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Documentation
Issued 10 April 1997 Resolved
VESSEL DID NOT HAVE LOG OF TESTS/DRILLS REQUIRED BY 46 CFR 185.520, 185.320, AND 185.728.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Lifesaving
Issued 10 April 1997 Resolved
VESSEL'S LIFE FLOATS NEED NEW RETROREFLECTIVE TAPE AND SEVERAL HOLES NEED TO BE PATCHED, 46 CFR 180.200.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Documentation
Issued 10 April 1997 Resolved
VESSEL DID NOT HAVE REQUIRED PUBLICATIONS ON BOARD, 46 CFR 184.420.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Accommodation/Occupational Safety
Issued 10 April 1997 Resolved
MAKE PERMANENT ALTERATION TO MSD BY INSTALLING A LEVEL INDICATOR THAT INDICATES WHEN THE MSD IS 3/4 FULL BY VOLUME TO SATISFACTION OF USCG MARINEINSPECTOR, REQUIRED BY 33 CFR 159.83.
Condition: Unknown
Due 23 April 1997
Resolved 23 April 1997
Lifesaving
Issued 10 April 1997 Resolved
VESSEL'S RING BUOYS NEED NEW RETRORFLECTIVE TAPE, 46 CFR 180.70.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Navigation
Issued 10 April 1997 Resolved
VESSEL MISSING RADIO EMERGENCY BROADCAST PLACARD, 46 CFR 184.510.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Documentation
Issued 10 April 1997 Resolved
VESSEL MISSING PFD DONNING INSTRUCTION PLACARD, 46 CFR 185.516.
Condition: Unknown
Due 22 April 1997
Resolved 22 April 1997
Engineering
Issued 11 April 1994 Resolved
Install guard on chain drive for anchor winch.
Condition: Unknown
Due 11 April 1994
Resolved 11 April 1994
Construction/Loadline
Issued 28 March 1994 Resolved
Replace packing around bulkhead penetration for salt water line in forward engine room bulkhead
Condition: Unknown
Due 5 April 1994
Resolved 11 April 1994
Construction/Loadline
Issued 28 March 1994 Resolved
Renew/replace starboard longintudal for deck in #2 hold where it has workedloose
Condition: Unknown
Due 5 April 1994
Resolved 11 April 1994
Engineering
Issued 28 March 1994 Resolved
Renew forward cross bracket to motor mount bracket.
Condition: Unknown
Due 5 April 1994
Resolved 11 April 1994
Electrical
Issued 13 April 1993 Resolved
PROVIDE WATERTIGHT STUFFING TUBES FOR WIRING TO MOTORS & POWER PANEL BOXES IN ENGINE ROOM.
Condition: Unknown
Due 13 April 1993
Resolved 13 April 1993
Lifesaving
Issued 13 April 1993 Resolved
RENEW EPIRB BATTERY PRIOR TO OPERATING VESSEL GREATER THAN 20 MILES FROM A HARBOR OF SAFE REFUGE.
Condition: Unknown
Due 23 April 1993
Resolved 23 April 1993
Documentation
Issued 12 February 1993 Resolved
Submit revisions to plans as noted during 17AUG92 review by MSO Corpus Christi.
Condition: Unknown
Due 12 February 1993
Resolved 12 February 1993
Documentation
Issued 16 April 1992 Resolved
Submit inboard and outboard profile, amidship section (plan review), and schematic of electrical installation plans to cognizant OCMI._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 16 April 1992
Resolved 16 April 1992
Documentation
Issued 16 April 1992 Resolved
Have vessel readmeasured and supply result to local (cognizant) OCMI and reflected information on Certificate of Inspection._x001C_ _x001C_ _x001C_
Condition: Unknown
Due 15 October 1992
Resolved 3 June 1992
Construction/Loadline
Issued 7 June 1990 Resolved
PROVIDE & INSTALL CAPTIVE CHAINS ON DECK WATERTIGHT HATCHES.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Navigation
Issued 7 June 1990 Resolved
MAKE PERMANENT REPAIRS TO LOOSE PLAY IN STEERING SYSTEM CONNECTI;NG POINTS ON STBD QUARDRANT ARM & HYD. RAM BASE.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Engineering
Issued 7 June 1990 Resolved
REPAIR FUEL TANK LEAK IN STEERING COMPARTMENT.
Condition: Unknown
Due 7 June 1990
Resolved 7 June 1990
Electrical
Issued 17 May 1990 Resolved
REMOVE SPLICE IN BATTERY CABLE TO PORT ROTARY SWITCH.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Engineering
Issued 17 May 1990 Resolved
INSTALL PROTECTIVE GUARDS ON POTABLE WATER PUMP AND MAIN ENGINE ALTERN- ATORS P&S.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Navigation
Issued 17 May 1990 Resolved
RENEW STBD RUNNING LIGHT FIXTURE.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Navigation
Issued 17 May 1990 Resolved
INSTALL BULB OF PROPER HEIGHT IN PORT RUNNING LIGHT.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Navigation
Issued 17 May 1990 Resolved
INSTALL CORRECT LENS ON FWD RANGE LIGHT.
Condition: Unknown
Due 17 May 1990
Resolved 17 May 1990
Lifesaving
Issued 10 May 1988 Resolved
REPLACE GRAB LINE ON LIFERING OUTSIDE PILOT HOUSE
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Engineering
Issued 10 May 1988 Resolved
REINSTALL EMERGENCY FUEL SHUTOFF REACH ROD AND STENCIL EMERGENCY FUEL SHUTOFF
Condition: Unknown
Due 10 May 1988
Resolved 10 May 1988
Navigation
Issued 25 April 1986 Resolved
CG-835:"MAKE VESSEL AVAILABLE FOR COAST GUARD INSPECTION OF STEERING GEAR JOCKEY BAR NO LATER THAN 30 MAY 86."
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986
Electrical
Issued 25 April 1986 Resolved
CG-835:"HAVE ALL LOOSE WIRING AND WIRING SPLICED WITH ELECTRICAL TAPE SAFE-LY CONNECTED OR SPLICED NO LATER THAN 30 MAY 86."
Condition: Unknown
Due 25 April 1986
Resolved 25 April 1986

Casualty record · 2

6 August 2010Routine · role: Involved in a Marine Casualty · serious marine incident, as classified · 1 injured · activity 3816771
18 March 2011Routine · role: Transiting Vicinity of Primary Subject · activity 3970431
Each line is an incident investigation the Coast Guard recorded with this hull among the vessels involved, with the date and the classification the Coast Guard gave it, and the bridge, lock or dam the investigation names where it names one. Involvement is not fault. The investigation narrative is not published. Source: IIR, through 2026.

Recorded names · 1

DOLPHIN EXPRESS (2010–2011). Names as the Coast Guard recorded them in incident records, with the years they appear; some are renames and some are spelling variants.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.