MAURY USCG vessel records Sign in
← All vessels

LORI D

LORI D is a 1977 passenger vessel (inspected). The Coast Guard has recorded 70 inspections since 1981, most recently in November 2022, along with 40 deficiencies.

Records from 1981 to 2022. Most recent: inspection, 1 November 2022.

Built
1977
Last inspected
1 November 2022
Documentation
Not in the documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WYL9658
Flag
UNITED STATES
366537000 (licence lapsed)
Maury page id
psix-49412

Inspections, by type

…with no type recorded8
Years with a record 38 calendar years (1981–2022)
The 70 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

This record may be incomplete: the most recent inspection recorded for this vessel was 4 years ago. Maury shows what the Coast Guard recorded, not whether the vessel has been inspected since, is still in service, or what condition it is in. Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Tonnage as PSIX records it99 - Regulatory (Subpart C or D), Gross Ton
67 - Regulatory (Subpart C or D), Net Ton
This hull's Official Number is not in the NVDC file dated 10 September 2026 as served by NOAA Fisheries, so no documentation record is shown. Absence from that file is a fact about the file, not about the hull.

Radio station licence

WYL9658MMSI 366537000 · cancelled · compulsorily equipped · granted 11 August 2017, cancelled 5 May 2025
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 70

1 November 2022 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7587280
6 July 2022 COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7496635
6 October 2021 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7327687
28 April 2021 Drydock Exam · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7196827
13 November 2020 Administrative Inspection
Administrative · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7094690
12 August 2020 DAPI Audit · Administrative Inspection · Annual Inspection · In-Service Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 7026539
4 September 2019 Annual Inspection · Administrative Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6807762
29 April 2019 Administrative Inspection · Hull Examination · Internal Structural Exam
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6673207
4 September 2018 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6532568
28 April 2017 Internal Structural Exam · Hull Examination · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6134684
12 April 2017 DAPI Audit · Administrative Inspection · Deficiency Check · COI Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 6123136
15 June 2016 DAPI Audit · Annual Inspection · Administrative Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 5904207
26 June 2014 Annual Inspection · Deficiency Check · Administrative Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 4899528
12 August 2011 Administrative Inspection · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 4109119
13 October 2010 Deficiency Check · In-Service Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 3869514
11 March 2010 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 3692435
26 June 2008 Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 3239118
26 June 2007 Internal Structural Exam · Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2974527
5 April 2007 COI Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2902199
26 May 2006 Re-Inspection
Physical examination · Marine Safety Unit Houma · USCG Heartland District (CGD-H) · Activity 2659673
20 June 2005 Hull Examination · Internal Structural Exam · Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 2396282
22 June 2004 Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2106638
17 June 2004 Annual Inspection · Internal Structural Exam
Physical examination · MSU LAKE CHARLES · USCG Heartland District (CGD-H) · Activity 2103597
7 January 2004 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1978896
6 January 2004 Annual Inspection
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1965674
9 September 2003 Deficiency Check
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1901557
4 September 2003 Hull Examination
Physical examination · Marine Safety Detachment Panama City · USCG Heartland District (CGD-H) · Activity 1900781
25 April 2002 COI Inspection
Physical examination · MIDET HARVEY CANAL DETAIL · USCG Heartland District (CGD-H) · Activity 1608995
8 May 2001 Re-Inspection · Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1472064
28 June 2000 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1393485
30 April 1999 Hull Examination · COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1426231
15 October 1998 Deficiency Check
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 802333
9 September 1998 Re-Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1375490
17 December 1997 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1364486
24 September 1997 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 778213
12 September 1997 Re-Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1454474
26 February 1997 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1099708
30 January 1997 Type not recorded
No type recorded · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1102668
13 August 1996 Administrative
Administrative · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1089420
10 July 1996 COI Inspection
Physical examination · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1405931
6 November 1995 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1421034
13 July 1995 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 1392262
16 August 1994 Deficiency Check
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 868024
13 July 1994 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1367096
7 April 1994 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1168227
13 July 1993 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1457107
24 November 1992 Hull Examination
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1440649
13 July 1992 COI Inspection
Physical examination · MSU GALVESTON · USCG Heartland District (CGD-H) · Activity 952290
16 April 1992 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1405314
6 August 1991 Administrative
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 939842
16 July 1991 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 941562
28 November 1990 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 920708
2 August 1990 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 925958
16 May 1990 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 930316
1 August 1989 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1043641
27 October 1988 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 889278
7 September 1988 COI Inspection
Physical examination · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1040373
13 July 1988 Drydock Extension
Administrative · MSO MORGAN CITY · USCG Heartland District (CGD-H) · Activity 1036534
9 September 1987 COI Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1318049
24 June 1987 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1006868
20 November 1986 Hull Examination
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1021381
26 September 1986 COI Inspection
Physical examination · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1317819
4 November 1985 Credit Drydock
Administrative · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1302141
26 September 1985 COI Inspection
Physical examination · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 992394
31 October 1984 Type not recorded
No type recorded · MSO PORT ARTHUR · USCG Heartland District (CGD-H) · Activity 1282171
25 September 1984 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 978969
7 October 1983 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277190
21 October 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1274280
4 March 1982 Type not recorded
No type recorded · MSO Mobile · USCG Heartland District (CGD-H) · Activity 1277580
3 November 1981 Type not recorded
No type recorded · MIO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 965213

Deficiency record · 40

04 - Emergency Systems › N/A - No Subsystem › Fire drills
Issued 4 September 2019 Resolved
Conduct man overboard and fire drill undrway in presence of attending Coast Guard Marine Inspector
Condition: Invalid
Action required: 17 - Rectify deficiencies prior to departure
Resolved 18 November 2019
Resolution: Conducted drills, all sat.
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 4 September 2018 Resolved
A vessel must be provided with a main steering gear of adequate strength and capability. The vessel has two cracks on the STBD rudder table and the rudder arm is hitting the stop on the STBD side. G/W the two fractures and adjust the the rudder arm.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2018
Resolved 10 September 2018
Resolution: Corrected, all SAT.
08 - Alarms › N/A - No Subsystem › Other (alarms)
Issued 4 September 2018 Resolved
The vessel is required to have an operational bilge alarm system. The vessel's bilge alarm system was not operational. Conduct repairs to the bilge alarm system.
Condition: Improper/Lack of Maintenance
Action required: 17 - Rectify deficiencies prior to departure
Due 4 September 2018
Resolved 10 September 2018
Resolution: Corrected, all SAT.
Lifesaving › Lifebuoys › Buoyant Lifeline
Issued 12 April 2017 Resolved
Life ring line needs to be changed out.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 28 April 2017
Resolution: Line was replaced.
Fire Fighting › Fire Hoses › Condition
Issued 12 April 2017 Resolved
Fire hose had a leak
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 28 April 2017
Resolution: Fire hose was replaced.
Communications › Audible Communications › SPD (Other)
Issued 12 April 2017 Resolved
Intercomm system was malfunctioning.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 28 April 2017
Resolution: Intercomm system was replaced
Engineering › Bilge Water Management System › Manifold
Issued 12 April 2017 Resolved
Bilge system was inoperable.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 18 April 2017
Resolved 8 June 2017
Resolution: Bilge system was replaced and satisfactory tested
Communications › Public Address System › Loudspeaker
Issued 26 June 2014 Resolved
PA system powers on but does not provide proper operation to any speakers throughout vsl.
Action required: 705 - Other - as specified
Due 26 July 2014
Resolved 9 July 2014
Resolution: [name withheld] witnessed proper operation of PA system during deficiency check.
Navigation › Collision/Grounding Avoidance › Day Shapes
Issued 26 June 2014 Resolved
Missing diamond day shape.
Action required: 705 - Other - as specified
Resolved 9 July 2014
Resolution: [name withheld] witnessed diamond day shape during deficiency check.
Electrical › Electrical Distribution System (service) › Shore Connection Box
Issued 26 June 2014 Resolved
Open hole found in bottom of shore power switch box.
Action required: 705 - Other - as specified
Resolved 9 July 2014
Resolution: [name withheld] witnessed repaired switch box during deficiency check.
Stability › Watertight Integrity › General
Issued 26 June 2014 Resolved
Cable run penetration through forward engine room watertight bulkhead penetration found to be inadequate.
Action required: 705 - Other - as specified
Resolved 26 July 2014
Resolution: Crew removed wasted sealant and applied new sealant restoring watertight integrity.
Fire Fighting › Fixed Deck Foam System › Hose Connection
Issued 26 June 2014 Resolved
AFFF eductor not providing adequate suction. Vsl not to carry portable tanks until providing proper operation of eductor.
Action required: 705 - Other - as specified
Resolved 4 September 2014
Resolution: [name withheld] wtinessed proper operation of the AFFF eductor and cleared final deficiency.
Engineering › Diesel Engine (propulsion/auxiliary-electric) › Piping (exhaust)
Issued 13 October 2010 Resolved
Stbd generator is discharging oil through exhaust piping onto heat blankets causing a fire hazard. Make repairs, fix leaks, and replace heat blanket. This generator is not to be used unless it is an extreme emergency (port generator failure, and only to bring the vessel safely to port).
Action required: 705 - Other - as specified
Due 13 November 2010
Resolved 29 October 2010
Resolution: Installed new generator and repaired exhaust.
Accommodation/Occupational Safety › Occupational Safety
Issued 23 December 2003 Resolved
Provide insulation on #1 and #4 main diesel engine exhaust pipe as required by 46 CFR 182.430, 425, and 405. LEGACY COMPONENT DESC: Guards for Exposed Hazards
Action required: 705 - Other - as specified
Due 6 February 2004
Resolved 7 January 2004
Resolution: Owner provided insulation on #1 and #4 MDE exhaust pipe.
Construction/Loadline › Hull
Issued 4 September 2003 Resolved
Repair aluminum stiffener fractures in stern corners as identified. LEGACY COMPONENT DESC: Stiffener
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 9 September 2003
Resolution: Owner repaired aluminum stiffener fractures.
Construction/Loadline › Penetrations
Issued 4 September 2003 Resolved
Remove and clean all through hull valves to facilitate inspection. LEGACY COMPONENT DESC: Valves
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 9 September 2003
Resolution: Owner removed and cleaned valves to facilitate inspection.
Accommodation/Occupational Safety › Potable Water System
Issued 4 September 2003 Resolved
Replace hot water heater relief valve with 100 psi relief valve. LEGACY COMPONENT DESC: Relief Valve
Action required: 705 - Other - as specified
Due 4 October 2003
Resolved 9 September 2003
Resolution: Owner replaced hot water heater relief valve.
Construction/Loadline
Issued 9 September 1998 Resolved
CAP BY MEANS OF WELDING AN ALUMINUM PLATE OVER THE OPEN END OF THE DISCONNETED FIRE MONITOR PIPE LOCATED IN THE ENGINE ROOM OVERHEAD.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Construction/Loadline
Issued 9 September 1998 Resolved
REPAIR 2" HOLE LOCATED ON MAIN DECK AROUND THE BULWARK. HOLE DOES NOT PENETRATE HULL.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Lifesaving
Issued 9 September 1998 Resolved
ENSURE ALL OF THE FOLLOWING ARE PROPERLY MARKED: EMERGENCY LIGHTS, WTDS, STBD LIFE RING (MAIN DECK), LIFE JACKETS AND LIFE FLOATS. MOST ARE FADED.
Condition: Unknown
Due 9 September 1998
Resolved 9 September 1998
Navigation
Issued 12 September 1997 Resolved
REPAIR OR REPLACE THE SINGLE SIDE BAND RADIO.
Condition: Unknown
Due 12 September 1997
Resolved 12 September 1997
Navigation
Issued 12 September 1997 Resolved
REPAIR OR REPLACE THE FATHOMETER.
Condition: Unknown
Due 12 September 1997
Resolved 12 September 1997
Documentation
Issued 12 September 1997 Resolved
PLACE ON BOARD THE VESSEL THE VALID F.C.C. STATION LICENSE.
Condition: Unknown
Due 12 September 1997
Resolved 12 September 1997
Documentation
Issued 12 September 1997 Resolved
OBTAIN AND PLACE ON BOARD A VALID F.C.C. SAFETY TELEPHONY CERTIFICATE.
Condition: Unknown
Due 12 September 1997
Resolved 12 September 1997
Engineering
Issued 12 September 1997 Resolved
REPAIR OR REPLACE THE JACKET WATER TEMPERATURE GAUGE FOR THE PORT OUTBOARD MAIN DIESEL ENGINE.
Condition: Unknown
Due 12 September 1997
Resolved 12 September 1997
Fire Fighting
Issued 30 January 1997 Resolved
PROVIDE AT EACH FIRE STATION AN APPROVED COMBINATION NOZZLE OR ONE THAT PROVIDES A SOLID ONE HALF INCH STREAM IAW 46 CFR 181.15-10(d)(2).
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Lifesaving
Issued 30 January 1997 Resolved
PROVIDE A MEANS OF WHICH TO RETAIN THE SIX PERSON LIFEFLOAT AND KEEP IT FLOATFREE MAKING NO USE OF LASHINGS OR TIE DOWNS.
Condition: Unknown
Due 30 January 1997
Resolved 30 January 1997
Accommodation/Occupational Safety
Issued 10 July 1996 Resolved
REPAIR PARTED SEWAGE LINE TO DECK FITTING.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Electrical
Issued 10 July 1996 Resolved
REMOVE DEAD-ENDED ELECTICAL CABLE AND OLD CENTRAL VACUUM PIPING IN VOID ADJACENT TO FORWARD PASSENGER SPACE.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Navigation
Issued 10 July 1996 Resolved
PROVIDE CURRENT TIDAL CURRENT TABLES.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Engineering
Issued 10 July 1996 Resolved
REPLACE WASTED PIPE NIPPLE ON RAW WATER LINE ON STBD OUTBOARD ENGINE.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Engineering
Issued 10 July 1996 Resolved
PROVE PROPER OPERATION OF RED GEAR ON PORT OUTBOARD ENGINE.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Engineering
Issued 10 July 1996 Resolved
REPAIR EXHAUST LEAK ON STBD OUTBOARD ENGINE.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Engineering
Issued 10 July 1996 Resolved
REPLACE BROKEN SPACER BLOCKS ON ALL ENGINE MOUNTS.
Condition: Unknown
Due 10 July 1996
Resolved 10 July 1996
Lifesaving
Issued 13 July 1994 Resolved
PROVIDE ON BOARD A RESCUE BOAT OR EQUIVALENT AS REQUIRED BY 46 CFR 180.10-_x001C_35 AND [name withheld].
Condition: Unknown
Due 13 July 1994
Resolved 13 July 1994
Construction/Loadline
Issued 13 July 1993 Resolved
PROVIDE PROPER DOCUMENTATION FOR VENTILATION HOLES OF 3" DIAMETER AT 6FT LVL OF WATERTIGHT BULKHEAD BETWEEN GENERATOR ROOM AND RUDDER ROOM AT FRAME 25 TO PROVE ACCEPTABILITY WITHIN CONSTRAINTS OF STABILITY LETTER DTD 13JULY84.
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Navigation
Issued 13 July 1993 Resolved
REPAIR/RENEW/REPLACE AFT STEERING STATION CONTROL VALVE ON BRIDGE.
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Engineering
Issued 13 July 1993 Resolved
MAKE STBD CENTER FUEL TANK AVAILABLE AND PROVIDE ADEQUATE MEANS TO TEST INTEGRITY OF 8" WELD ALONG TOP INBOARD SIDE OF FUEL TANK IN THE PRESENCE OFA MARINE INSPECTOR.
Condition: Unknown
Due 19 July 1993
Resolved 19 July 1993
Deck/Cargo
Issued 26 September 1986 Resolved
PROVIDE AT LEAST ONE 180 POUND DANFORTH STANDARD ANCHOR ONBOARD THE VESSEL WITH AN ANCHOR LINE WHICH HAS AN APPROXIMATE BREAKING STRENGTH OF 23,000 POUNDS.
Condition: Unknown
Due 26 September 1986
Resolved 26 September 1986
Unknown
Issued 31 October 1984 Resolved
FORWARD THE FOLLOWING ITEMS TO MSO, PORT ARTHUR, TEXAS: A. WELDING PROCEDURE QUALIFICATION FOR APPLICABLE ALUMINUM MATERIALS; B. WELDER PERFORMANCE QUALIFICATION FOR [name withheld].
Condition: Unknown
Due 31 October 1984
Resolved 31 October 1984

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.