Documentation record
Registered dimensions (L × B × D)94.5 ft × 25.2 ft × 7.1 ft
Registered tonnagegross 96 / net 65
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderGULF CRAFT INC. · PATTERSON, LA, UNITED STATES · built 1977
Hull materialAluminum
PropulsionDiesel Reduction
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portLOS ANGELES, LA
Endorsements, as the file codes themcw_un, reg
DocumentationValid · issued 8 October 2025 · expires 31 October 2026
Service, as the file records itOffshore Supply Vessel
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it96 - Regulatory (Subpart C or D), Gross Ton
65 - Regulatory (Subpart C or D), Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel
Behind this panel: 19 inspections, each with its date, unit and type; 15 deficiencies with the resolution recorded against each, 1 without one; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast
Guard wrote; the counts above are the same counts as in the summary, and they are free.
Professional is $39 a month or $299 a year,
or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks
every detail section on every vessel page, fleet watch tied to your account, and ownership records
on request. Already a subscriber? Sign in.
Maury does not score, rate or grade vessels, at any price.
Inspection history · 19
18 March 2025
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 8097123
10 September 2024
Deficiency Check · Hull Examination
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7851211
2 May 2024
Administrative Inspection · Deficiency Check · Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7906023
28 March 2023
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7635294
27 December 2022
Plan Review "T" Boat
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7613873
24 August 2022
Examination of Repairs · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7522584
29 March 2022
COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7407685
2 June 2021
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7179806
12 December 2020
Administrative Inspection
Administrative · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7110825
14 October 2020
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 7074738
5 October 2020
Administrative Inspection · Plan Review "T" Boat
Administrative · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 7072024
29 June 2020
Annual Inspection
Physical examination · Sector Los Angeles/Long Beach · USCG Southwest District (CGD-SW) · Activity 6990331
4 October 2019
Type not recorded
No type recorded · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6830631
13 May 2019
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6680328
13 September 2018
Deficiency Check · Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6537037
18 April 2018
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6369204
5 April 2017
DAPI Audit · COI Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6111241
19 September 2016
Hull Examination
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 6004204
22 June 2016
Annual Inspection
Physical examination · Marine Safety Detachment Santa Barbara · USCG Southwest District (CGD-SW) · Activity 5913722
02 - Structural Conditions › N/A - No Subsystem › Steering gear
Issued 2 May 2024
No resolution recorded
Repairs or alterations to the hull, machinery, or equipment that affect the safety of the vessel must not be made without the approval of the cognizant OCMI, except during an emergency. When repairs are made during an emergency, the owner, managing operator, or master shall notify the OCMI as soon as practicable after such repairs or alternations are made. Vessel's lazarette had 8-10 inches of water from leaking rudder post packing. Vessel O/O is aware and daily inspection is required in Helm Connect. Vessel is required to keep performing daily inspections, monitor and pump bilge as needed, and to notify Coast Guard if situation worsens. Rudder packings shall be replaced NLT September FY24 drydock.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
11 - Life Saving Appliances › N/A - No Subsystem › Operational readiness of lifesaving appliances
Issued 2 May 2024
Resolved
A vessel of more than 19.8 meters (65 feet) in length must carry at least one rescue boat unless the cognizant OCMI determines that:(1) The vessel is sufficiently maneuverable, arranged, and equipped to allow the crew to recover a helpless person from the water. Vessel's person recovery davit shackle did not fit pulley rope carabiner. Vessel replaced the shackle to fit the carabiner. Deficiency corrected on site.
Condition: Improper Installation
Action required: 10 - Deficiency Rectified
Due 3 May 2024
Resolved 2 May 2024
Resolution: Vessel replaced davit shackle to fit carabiner.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 2 May 2024
Resolved
A voltmeter and an ammeter, which can be used for measuring voltage and current of a generator that is in operation, must be provided for a generator rated at 50 volts or more. For each alternating current generator, a means for measuring frequency must also be provided. Switchboard voltmeters were not reading generator voltage. Vessel replaced fuse with test SAT.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Resolved 2 May 2024
Resolution: Vessel replaced fuse with SAT test.
07 - Fire Safety › N/A - No Subsystem › Maintenance of Fire protection systems
Issued 28 March 2023
Resolved
Portable and semi-portable extinguishers must be inspected and maintained in accordance with NFPA 10 (incorporated by reference, see § 175.600 of this chapter) as amended. The portable CO2 fire extinguisher serving as the fixed extinguisher for the paint locker was found with a deteriorated discharge hose and with an out of date hydrostatic test date for the cylinder. Provide cylinder within hydrostatic test dates with a serviceable discharge hose.
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 11 April 2023
Resolution: Vessel replaced CO2 extinguisher with a new, serviced one.
02 - Structural Conditions › N/A - No Subsystem › Beams, frames, floors-op. damage
Issued 28 March 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: (1) Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather decks. A crack was found in the transverse weld between the main deck and the transverse structural support for the bow stanchion. Grind and reweld.
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 11 April 2023
Resolved 14 April 2023
Resolution: Vessel repaired broken welds in stanchion support members.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 28 March 2023
Resolved
Except as allowed by paragraph (d) of this section, each life jacket must be approved in accordance with either § 160.002, § 160.005, or § 160.055 in subchapter Q of this chapter, or other standard specified by the Commandant, including, but not limited to, approval series 160.155 or 160.176. Eight life jackets were found unserviceable: missing lights, retro-reflective tape or stenciling. Vessel rectified items during inspection.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 28 March 2023
Resolved 28 March 2023
Resolution: Vessel provided missing equipment, stencils and retro tape.
10 - Safety of Navigation › N/A - No Subsystem › Charts
Issued 29 March 2022
Resolved
As appropriate for the intended voyage, a vessel must
carry adequate and up-to-date charts of large enough
scale to make safe navigation possible. Vessel's
charts were not updated. Provide current/corrected
charts for operational areas. Vessel has paper charts,
but utilizes electronic charts while navigating.
Electronic charts are from May 2009. Provide proof of
up-to date electronic or paper charts
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2022
Resolved 14 April 2022
Resolution: Provided proof of up-to date electronic or paper charts
01 - Certificates & Documentation › 012 - Crew Certificates › Certificates for master and officers
Issued 29 March 2022
Resolved
A person may not employ or engage an individual in a
position required to hold an MMC unless that individual
maintains a current medical certificate. Vessel's
licensed Master did not have medical certificate
available for inspection. Provide proof of medical
certificate or correspondence from NMC attesting to
valid medical certificate.
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 April 2022
Resolved 15 April 2022
Resolution: Provided proof of medical certificate or correspondence from NMC attesting to valid medical certificate.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 29 March 2022
Resolved
Electrical equipment on a vessel must be installed and
maintained to protect passengers, crew, other persons,
and the vessel from electrical hazards, including fire,
caused by or originating in electrical equipment, and
electrical shock. Dead-end wire exposed outside of
junction box leading to galley bilge high level alarm.
Remove/make wire in compliance with regulations
to satisfaction of attending Marine Inspector.
Action required: 10 - Deficiency Rectified
Resolved 29 March 2022
Resolution: Removed/made wire in compliance with regulations to satisfaction of attending Marine Inspector.
Fire Fighting › Means of Escape › Escape Route Signs
Issued 5 April 2017
Resolved
Properly mark emergency escape hatches from E/R and genset compartment.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 15 May 2017
Resolution: Hatches properly marked.
Engineering › Diesel Engine (propulsion-reduction gear) › Exhaust Manifold
Issued 5 April 2017
Resolved
Install missing sections of lagging on MDE exhaust lines.
Action required: 705 - Other - as specified
Due 5 May 2017
Resolved 15 May 2017
Resolution: Lagging installed.
Deck/Cargo › Holds/Tanks › Hatch Cover
Issued 19 September 2016
Resolved
Replace gasket on hatch cover to laz.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 22 September 2016
Resolution: Gasket replaced.
Stability › Watertight Integrity › Watertight Subdivision Standard
Issued 19 September 2016
Resolved
Make watertight unused penetration through aft E/R bulkhead portside of WTD.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 29 September 2016
Resolution: Penetration welded and made watertight.
Construction/Loadline › Hull › Bottom Plating
Issued 19 September 2016
Resolved
Clean and clad weld isolated pits port aft E/R.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 22 September 2016
Resolution: Clad welds completed, all sat.
Construction/Loadline › Hull › Weld
Issued 19 September 2016
Resolved
Open up for further inspection wet area of forward keel cooler stbd side.
Action required: 705 - Other - as specified
Due 30 September 2016
Resolved 22 September 2016
Resolution: Cracked weld gouged and rewelded, all sat.