Inspection history · 87
1 November 2023
Administrative Inspection
Administrative · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 7818797
17 August 2010
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3826982
27 May 2010
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3749507
27 May 2010
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 3756036
21 May 2010
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3746696
20 May 2010
Damage Survey
Physical examination · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3743241
29 April 2010
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3727236
10 April 2010
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3713487
22 March 2010
Type not recorded
No type recorded · Marine Safety Unit Kodiak · USCG Arctic District (CGD-A) · Activity 3700876
5 March 2010
MARPOL Annex I Examination · Annual Inspection
Physical examination · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 3690470
1 August 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3553611
5 July 2009
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3524461
22 April 2009
Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3458409
18 April 2008
Annual Inspection · Deficiency Check
Physical examination · Marine Safety Detachment Ketchikan · USCG Arctic District (CGD-A) · Activity 3187152
14 April 2008
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3183938
28 February 2008
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3155297
25 October 2007
Hull Examination · Internal Structural Exam
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 3087131
29 June 2007
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2977752
29 June 2007
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2977779
13 March 2007
MTSA Verification · Annual Inspection
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2886946
13 February 2007
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2872018
14 December 2006
Type not recorded
No type recorded · Sector Southeast Alaska · USCG Arctic District (CGD-A) · Activity 2840605
25 September 2006
Administrative Inspection
Administrative · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2786798
30 June 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2696468
30 June 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2696522
14 June 2006
Damage Survey
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2680452
19 April 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2628625
16 April 2006
Type not recorded
No type recorded · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2627624
10 February 2006
MARPOL Annex I Examination · COI Inspection · MTSA Verification · Cargo Tank Internal · Internal Structural Exam · Hull Examination
Physical examination · Sector Puget Sound · USCG Northwest District (CGD-NW) · Activity 2586292
17 January 2006
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2568048
25 October 2005
Administrative Inspection
Administrative · Marine Safety Center (MSC) · Activity 2521579
25 October 2005
Security Plan Review - ASP
Administrative · Marine Safety Center (MSC) · Activity 2521642
11 August 2005
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2459462
13 July 2005
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2431311
22 April 2005
Annual Inspection · MTSA Verification
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2340899
24 February 2005
Damage Survey · Deficiency Check
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2300538
15 November 2004
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 2242091
7 May 2004
Annual Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 2086235
4 December 2003
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1959086
25 November 2003
Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1958201
2 November 2003
Damage Survey
Physical examination · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1940533
31 October 2003
Type not recorded
No type recorded · Marine Safety Unit Dutch Harbor · USCG Arctic District (CGD-A) · Activity 1939881
2 May 2003
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1783144
18 February 2003
Hull Examination · Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1757073
27 January 2003
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1736124
10 December 2002
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1735138
20 November 2002
Internal Structural Exam · Cargo Tank Internal
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1708229
24 April 2002
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1608405
9 March 2002
Damage Survey
Physical examination · Marine Safety Detachment Kenai · USCG Arctic District (CGD-A) · Activity 1599171
2 April 2001
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1470595
29 November 2000
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1415499
3 December 1999
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 812967
27 May 1999
Type not recorded
No type recorded · Marine Safety Unit Valdez · USCG Arctic District (CGD-A) · Activity 518646
13 January 1999
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1470755
25 March 1998
Damage Survey · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1409837
13 November 1997
COI Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1388409
15 March 1997
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 441793
3 February 1997
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1422777
20 November 1996
Re-Inspection
Physical examination · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 1392561
6 March 1996
Damage Survey
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1081410
27 November 1995
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 537831
17 November 1995
Deficiency Check · COI Inspection · Examination of Repairs · MARPOL Annex II Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1441009
26 October 1995
Damage Survey · Deficiency Check
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 876853
3 February 1995
Re-Inspection · Damage Survey
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1143877
18 January 1995
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 498397
19 January 1994
Hull Examination · COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1394050
16 November 1993
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 447539
19 July 1993
Damage Survey · Examination of Repairs
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1401756
15 July 1993
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 183681
17 June 1993
Re-Inspection
Physical examination · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1382633
17 November 1992
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1136037
7 June 1992
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 443447
7 May 1992
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1254550
27 February 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 652364
20 February 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 652363
2 February 1992
Type not recorded
No type recorded · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 173428
25 June 1991
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 907670
25 June 1991
Re-Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 908167
27 January 1991
Damage Survey · Examination of Repairs
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 918341
21 January 1991
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 915648
12 January 1991
Type not recorded
No type recorded · MSO JUNEAU · USCG Arctic District (CGD-A) · Activity 444731
14 December 1990
Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 925677
26 October 1990
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 916328
8 May 1990
COI Inspection
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1241004
27 June 1989
Type not recorded
No type recorded · MSO ANCHORAGE · USCG Arctic District (CGD-A) · Activity 1327163
19 May 1989
COI Inspection · Hull Examination
Physical examination · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 889104
29 May 1987
Administrative
Administrative · MSO PUGET SOUND · USCG Northwest District (CGD-NW) · Activity 1026847
Deck/Cargo › Holds/Tanks › Bulkhead
Issued 20 May 2010
Resolved
High LEL reading in Starboard Forward Void. Shouldn't be any reading in the void. Potential for damage to bulkhead between void and cargo tanks #1S and #1CS. See 835 in documents for more information.
Action required: 705 - Other - as specified
Due 30 May 2010
Resolved 3 June 2010
Resolution: All repairs were found to be satisfactory.
Engineering › Electric Propulsion System › Battery
Issued 29 April 2009
Resolved
The forward port prime mover failed to start due to dead battery bank.
Due 29 April 2009
Resolved 29 April 2009
Resolution: Batteries were replaced and prime mover operated to the satisfaction of on scene marine inspectors.
Electrical › Electrical Distribution System (service) › Ground Detection
Issued 18 April 2008
Resolved
Troubleshoot and repair ground that is indicated on barge ground detection panel.
Due 1 May 2008
Resolved 1 May 2008
Electrical › Electrical Distribution System (service) › Circuit Breaker
Issued 18 April 2008
Resolved
Install blank breaker cover in open slot on electrical panel in forward deckhouse.
Due 1 May 2008
Resolved 1 May 2008
Construction/Loadline › Structures › Door
Issued 18 April 2008
Resolved
Restore starboard door on forward deckhouse to operable condition.
Due 1 May 2008
Resolved 1 May 2008
Engineering › Pressure Vessel › Relief Valve
Issued 18 April 2008
Resolved
Provide proof of pressure test of relief valve on vessels air receiver.
Due 18 May 2008
Resolved 1 May 2008
Construction/Loadline › Hull › Hull Plating
Issued 14 June 2006
Resolved
While at anchor full of diesel; oil, diesel oil leaking from beneath water line; divers attempting to locate source. Wrote 835 to offload all tanks, go to drydock, locate source of leak & affect permanent repairs.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 18 June 2006
Resolution: Located and repaired crack. Vessel cleared to load cargo.
Construction/Loadline › Hull
Issued 2 November 2003
Resolved
Upon discharge of current cargo, deliver barge to port of repair and make available to U.S. Coast Guard for internal inspection. Complete permanent repairs to fractured bottom plate discovered in #3 Starboard and any other damage found in internal inspection prior to operation of barge. LEGACY COMPONENT DESC: Bottom Plating
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 2 December 2003
Resolved 25 November 2003
Resolution: Bottom plating inserted.
Construction/Loadline › Structures
Issued 20 November 2002
Resolved
Port outside tank #1: longitudinal bulkhead at frame 8 1/2 has approx. 3 in. fractured at transverse girder gusset connection. Operator will crop and insert into bulkhead 18" x 18" x 1/2" plate in way of fracture. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Condition: Unknown
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 25 March 2003
Resolution: Crop out and renewed with 18"x18"x1/2" steel plate. NDT sat.
Construction/Loadline › Hull
Issued 20 November 2002
Resolved
- Port tank #3: Frame #15 is detached from sideshell longitudinals #2 & 3. Sideshell longitudinal #2 is fractured through flange at connection to frame 15. Operator will crop and renew sideshell longitudinal #2 and reattach frame #15 to sideshell longitudial #3 by vee and weld. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 25 March 2003
Resolution: Frame # 15 reattach to sideshell long #3 with vee and weld, appeared sat. Crop out and renew sideshell long #2 IWO frame connection (Fr #15) approx 24" of 4"x6"x3/8" angle. Ndt appeared sat.
Construction/Loadline › Structures
Issued 20 November 2002
Resolved
- Port tank #4: Frame #19 detached from sideshell longitudinal #4 and sideshell longitudinal #4 is fractured through flange. Operator will crop and renew sideshell longitudinal #4 in way of frame connection and will reattach frame #19. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 25 March 2003
Resolution: Corrected above item. Appeared sat.
Construction/Loadline › Structures
Issued 20 November 2002
Resolved
Stbd tank #4: bottom longitudinal #17 in way of frame #18 fractured at rat-hole connection. Operator will crop and renew bottom longitudinal #17. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 25 March 2003
Resolution: Corrected above item. Sighted sat.
Construction/Loadline › Hull
Issued 20 November 2002
Resolved
port tank #5: Frame #24 is detached from sideshell longitudinal #4 and 5. Sideshell longitudinal #4 fractured through flange at frame connection. operator will crop and renew sideshell longitudinal #4 in way of frame connection and reattach sideshell longitudinal #5 by vee and weld. LEGACY COMPONENT DESC: Side Shell
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 25 February 2003
Resolution: Corrected above item. Sighted sat repair.
Construction/Loadline › Structures
Issued 20 November 2002
Resolved
Stbd tank #5: Bottom longitudinal #18 at frame #22 upset 0"-1" in way of rat-hole. Operator will crop and renew bottom longitudinal #18. LEGACY COMPONENT DESC: Longitudinal Bulkhead
Action required: 705 - Other - as specified
Due 31 January 2003
Resolved 25 February 2003
Resolution: Repaired with approx 36" of 6"x6"x3/8" angle. Sighted sat repair.
Deck/Cargo
Issued 3 December 1999
Resolved
Provide flame screen for #3 starboard tank opening.
Condition: Unknown
Due 3 December 1999
Resolved 3 December 1999
Electrical
Issued 20 November 1996
Resolved
Provide rubber mats for all breaker boxes.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Deck/Cargo
Issued 20 November 1996
Resolved
longitudinal btwn #2Port and #2Stbd believed to be compromised. Therefore owner is required to sound all tanks and check for thiefage after each loadand prior to each discharge and log same.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Deck/Cargo
Issued 20 November 1996
Resolved
Conduct air test of each cargo tank at next ISE to determine if there are any "pinhole" leaks between tanks.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Electrical
Issued 20 November 1996
Resolved
Provide blanks for breaker box located in aft pumproom.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Deck/Cargo
Issued 20 November 1996
Resolved
Prove proper operation of crane. Athwartship motion inop at RIN conducted 20NOV96.
Condition: Unknown
Due 20 November 1996
Resolved 20 November 1996
Deck/Cargo
Issued 17 November 1995
Resolved
AMEND OIL TRANSFER PROCEDURES TO INCLUDE A DESCRIPTION OF THE OVERFILL DEVICES INCLUDING THE SYSTEM AND PROCEDURES FOR THE PIC TO (1) MONITOR THE LEVEL OF CARGO IN TANKS, AND SHUTDOWN TRANSFER OPS IN TIME TO ENSURE THAT THE CARGO LEVEL IN EACH TANK DOES NOT OVERFILL, (2) LIST TESTING PROCEDURES
Condition: Unknown
Due 1 December 1995
Resolved 6 December 1995
Deck/Cargo
Issued 17 November 1995
Resolved
SUBMIT PLANS FOR THE CARGO TANK OVERFILL INDICATING DEVICES.
Condition: Unknown
Due 1 December 1995
Resolved 6 December 1995
Electrical
Issued 17 November 1995
Resolved
PROVIDE ELECTRICAL 1-LINE DIAGRAM FOR LIGHTING SYSTEM IN SPILL RESPONSE CONEX BOXES.
Condition: Unknown
Due 1 December 1995
Resolved 6 December 1995
Construction/Loadline
Issued 26 October 1995
Resolved
Vessel may proceed from Anchorage, Alaska to Seattle, Washington to make repairs to the hull. The carriage of cargo is not authorized. All testingand repairs shall be to the satisfaction of the cognizant OCMI.
Condition: Unknown
Due 26 October 1995
Resolved 26 October 1995
Documentation
Issued 3 February 1995
Resolved
VESSEL IS RESTRICTED TO DOMESTIC VOYAGES UNTIL RECEIVING AN ITC CERTIFICATE.
Condition: Unknown
Due 3 February 1995
Resolved 3 February 1995
Deck/Cargo
Issued 19 January 1994
Resolved
PROVIDE REPORT OF CARGO PIPING/HOSE HYDROSTATIC TEST
Condition: Unknown
Due 14 February 1994
Resolved 18 February 1994
Deck/Cargo
Issued 19 January 1994
Resolved
PROVIDE REPORT OF CARGO PUMP RELIEF VALVE TEST
Condition: Unknown
Due 14 February 1994
Resolved 18 February 1994
Construction/Loadline
Issued 21 January 1991
Resolved
Make permanent repairs in way of the temporary repairs in the #1 & #2 starboard cargo tanks. Under bottom to be examined for other possible damage.
Condition: Unknown
Due 21 January 1991
Resolved 21 January 1991