Records from 1999 to 2025. Most recent: inspection, 15 August 2025.
Documentation record
Registered dimensions (L × B × D)38.0 ft × 12.0 ft × 2.5 ft
Registered tonnagegross 9 / net 7
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderTHOMAS BOAT CO. · SLIDELL, LA, UNITED STATES · built 1999
Hull materialAluminum
PropulsionGasoline Outboard
Hull shapeBox
Hull configurationMonohull
Hailing portNEW ORLEANS, LA
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 31 July 2026 · expires 31 August 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it9 - Simplified, Gross Ton
7 - Simplified, Net Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.
Inspection history · 19
15 August 2025
COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8196572
18 October 2024
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 8010381
7 September 2023
Annual Inspection · Internal Structural Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7786837
29 September 2022
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7552544
23 August 2021
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7277183
10 July 2020
COI Inspection · Drydock Exam
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 7002942
5 February 2020
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6903518
21 August 2019
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6777797
28 June 2018
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6448616
17 July 2017
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 6208597
29 July 2016
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 5952442
26 June 2014
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4894039
19 June 2012
Annual Inspection
Physical examination · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4342693
3 February 2012
Administrative Inspection
Administrative · Sector New Orleans · USCG Heartland District (CGD-H) · Activity 4237535
1 May 2003
Annual Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1838414
29 April 2002
COI Inspection
Physical examination · MIDET EAST BANK DETAIL · USCG Heartland District (CGD-H) · Activity 1609760
30 April 2001
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1448270
1 May 2000
Re-Inspection
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1389072
4 May 1999
COI Inspection · Initial Construction-Excluding Oversight · Hull Examination
Physical examination · MSO NEW ORLEANS · USCG Heartland District (CGD-H) · Activity 1460292
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 19 September 2023
Resolved
At each initial and subsequent inspection for certification of a vessel, the owner or managing operator shall be prepared to conduct tests and have the vessel ready for inspections of the hull structure and its appurtenances, including the following: Inspection of all accessible parts of the exterior and interior of the hull, the watertight bulkheads, and weather deck. MI observed cracked aluminum welds along the transom near port and starboard engine mounting brackets.
46 CFR 176.802(a)(1)
16 c
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 25 September 2023
Resolution: Operator effected weld repair on transom cracks and provided photo documentation to the satisfaction of the MI.
03 - Water/Weathertight Conditions › N/A - No Subsystem › Manholes/flush scuttles
Issued 19 September 2023
Resolved
The weather deck on a flush deck vessel must be watertight and have no obstruction to overboard drainage. MI observed missing hardware and broken gasket material on forward deck cover and dry rotted gasket on aft deck hatch.
46 CFR 178.40
16 c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 2 October 2023
Resolved 10 October 2023
Resolution: Operator effected repair by replacing adhesive sealant and hardware on forward deck covers and replacing gasket on watertight hatch. Provided photographs of repairs to the satisfaction of the marine inspector.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 19 September 2023
Resolved
An adult life jacket must be provided for each person carried on board a vessel. In addition, a number of child size life jackets equal to at least 10% of the number of persons permitted on board must be provided. MI observed 13 adult and 04 child size life jackets in unserviceable condition.
46 CFR 180.71
10 c
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 September 2023
Resolved 19 September 2023
Resolution: MI observed operator destroy unserviceable life jackets and replace with serviceable itmes.
Lifesaving › Lifejacket/PFD (Type I) › Quantity
Issued 17 July 2017
Resolved
Missing 11 serviceable adult type I PFDs & 1 serviceable child type I PFD. Vessel restricted to carrying 52 adult & 6 child passengers until faulty lifejackets replaced.
Action required: 705 - Other - as specified
Resolved 19 July 2017
Resolution: Received proof of new lifejackets.
Documentation › Markings/Placards › Lifejacket Placard
Issued 29 July 2016
Resolved
Vessel did not have lifejacket donning instructions posted.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 July 2016
Resolved 29 July 2016
Resolution: Rep found the lifejacket donning instructions for Revere 160, on another vsl (same as this vessel, copied and placed it on the board this vessel.
Lifesaving › Hand Flares › Storage
Issued 29 July 2016
Resolved
Flares were not in a watertight container with proper labeling for storage.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 3 August 2016
Resolved 29 July 2016
Resolution: Vsl rep sent a picture of watertight container, labeled properly.
Construction/Loadline › Markings › Vessel Name/Home Port
Issued 29 July 2016
Resolved
Vessel does not have hailing port marked on the stern of vessel.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 29 August 2016
Resolved 9 August 2016
Resolution: Vsl rep sent pic of the hailing port markings on the stern of the vessel.
Engineering › Fuel Oil Service System › Valve
Issued 26 June 2014
Resolved
Vessel missing quick connect or fuel shut off valve and fuel shut off and placard or stencil.46CFR182.455 (b)(4)
Condition: Design Flaw
Due 26 July 2014
Resolved 29 August 2014
Resolution: Fuel shut off valves were installed.
Operations/Management › Drug and Alcohol Testing › Proof of Enrollment
Issued 26 June 2014
Resolved
Recent shift of company policy and no records onboard that provided proof of periodic testing or enrollment of documented mariners. 46CFR16.210 and 46CFR 16.230
Condition: Invalid
Due 26 July 2014
Resolved 26 July 2014
Resolution: While inspection continuted representive was able to produce evidence of all operators enrollment in drug and alochol program and evidence of recent testing.
Construction/Loadline › Hull › Stringer
Issued 26 June 2014
Resolved
Transom between outboard engine mounts had a cracked weld at the bilge level where a stiffener/stringer meets the transom.
Condition: Damaged By Earlier Event
Due 26 July 2014
Resolved 29 August 2014
Resolution: Cracked weld was repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 26 June 2014
Resolved
Lens Covers for bathroom lighting and closet light were missing the protective covers.
Condition: Damaged By Earlier Event
Due 26 July 2014
Resolved 29 August 2014
Resolution: Light was completley removed and wires capped.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 26 June 2014
Resolved
First Aid Kit was missing 2" bandage, Trianglular Bandage, and Asprin. 46CFR160.041-4
Condition: Invalid
Due 26 July 2014
Resolved 29 August 2014
Resolution: Missing first aid kit contents were replaced.
Documentation
Issued 4 May 1999
Resolved
PROVIDE FCC STATION LICENSE AND SAFETY RADIO TELEPHONY CERTIFICATE._x001C_ _x001C_ _x001C_ _x001C_
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999
Documentation
Issued 4 May 1999
Resolved
POST STABILITY LETTER WHEN RECEIVED FROM [name withheld].
Condition: Unknown
Due 4 May 1999
Resolved 4 May 1999