MAURY USCG vessel records
← All vessels

TAHOE

Built
1950
Last inspected
29 May 2025
Documentation
Valid · NVDC file of 10 August 2026
Controls
None recorded without a removal date

Coast Guard record current through 23 August 2026, retrieved 5 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 2016.

Inspection record

Last inspected 29 May 2025
Operational controls None recorded without a removal date
Years with a record 10 calendar years (2016–2025)
Every line above is a count of records the US Coast Guard wrote, or a date it recorded. A blank resolution means none was recorded in this data; it does not establish that a deficiency is outstanding. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Identity

WCZ4828
494313
Flag
UNITED STATES
Maury page id
psix-494313

Documentation record

Registered dimensions (L × B × D)38.6 ft × 9.7 ft × 5.0 ft
Registered tonnagegross 11 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMONSON BOAT COMPANY · SEATTLE, WA, UNITED STATES · built 1950
Hull materialWood
PropulsionGasoline Engine
Hull shapeUNSPECIFIED
Hull configurationUNSPECIFIED
Hailing portZEPHYR COVE, NV
Endorsements, as the file codes themcw_un
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Regulatory (Subpart C or D), Gross Ton
8 - Regulatory (Subpart C or D), Net Ton
6 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 August 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.
Professional
The full record for this vessel

Behind this panel: 14 inspections, each with its date, unit and type; 18 deficiencies with the resolution recorded against each; operational controls, none recorded without a removal date; no tow-unit appearances recorded; no other recorded names; the documentation record: dimensions, tonnage, builder, hailing port and endorsements. Every line is a record the Coast Guard wrote; the counts above are the same counts as in the summary, and they are free.

Professional is $39 a month or $299 a year, or $19.99 a month locked for life at the founding rate, for the first 200 subscribers. It unlocks every detail section on every vessel page, fleet watch tied to your account, and ownership records on request. Already a subscriber? Sign in.

Maury does not score, rate or grade vessels, at any price.

Vessel history report

A report is not offered for this hull. Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. What a sparse-record report looks like.

Inspection history · 14

29 May 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8146732
12 May 2025 Deficiency Check · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8132941
7 August 2024 Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7976664
15 May 2024 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7907792
2 August 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7758668
9 May 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684782
29 April 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7440832
12 April 2021 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7173916
10 June 2020 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6972682
27 March 2020 Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6932257
13 May 2019 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681518
22 May 2018 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6415549
10 May 2017 Administrative Inspection · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138285
6 June 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5893984

Deficiency record · 18

09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 29 May 2025 Resolved
Procedures for checking the proper operation of a flammable vapor detection system must be posted at the primary operating station... A flammable vapor detection system must be operational for 30 seconds prior to engine startup and continue sensing the entire time the engine is running. Procedures are not posted at operating station to wait for green light on flammable vapor monitor indicator before starting engine. 46 CFR 182.480
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 24 June 2025
Resolution: Operator sent photograph of new vapor detection operating procedures to be posted at operating station. Photo uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 May 2025 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2-1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. One of the vessel's 3 fire buckets is more than 2.5 gallons. 46 CFR 181.610
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 10 June 2025
Resolution: Operator sent photo of correction to fire bucket. Uploaded to documents.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 May 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit was missing analgesic medication. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 30 May 2025
Resolution: Operator sent photo of new bottle of ibuprofen onboard.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 May 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel’s aft keel/worm shoe area show signs of wear and degradation clean to good wood and treat to the satisfaction of the Marine Inspector. 46 CFR 177.100
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2025
Resolved 23 May 2025
Resolution: Operator sent report detailing satisfactory repairs to the area. Report uploaded to documents tab.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025 Resolved
Cable and wire for power and lighting circuits must: (1) Meet Section 310-13 of NFPA 70 (incorporated by reference; see 46 CFR 175.600);(2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable; or(3) Meet § 111.60-1 in subchapter J of this chapter for cable, and § 111.60-11 in subchapter J of this chapter for wire. Speaker cable not rated for marine use was routed throughout the vessel. 46 CFR 183.340(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2025
Resolved 30 May 2025
Resolution: Operator sent video of completed marine grade speaker cable installation. Video uploaded to documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025 Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Vessel was found with plastic supports. 46 CFR 183.340(b)(4)
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2025
Resolved 29 May 2025
Resolution: MI attended vessel verifying appropriate metallic wire supports installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 May 2025 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel is required to conduct a post dry dock sea trial with Marine Inspector attendance prior to the carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2025
Resolution: MI attended vessel for satisfactory sea trial.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 May 2024 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present. Identified cable penetrations in forward engine room bulkhead that were not vapor tight. 46 CFR 177.405(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 15 May 2024
Resolution: Sealed cable penetrations.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 May 2024 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in vicinity of vent. No closure devices for vents found. 46 CFR 182.460(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 15 May 2024
Resolution: Operator provided photographs of vent closures.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2019 Resolved
A power-driven vessel underway shall exhibit: a masthead light; sidelights; and a sternlight. Starboard running light housing is cracked and requires replacement. Inland Nav Rule 23. Code 16
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 20 June 2019
Resolution: Running light housing replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2019 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. Drug and Alcohol program information required to complete the DAPI audit was not available onboard.46CFR16.201 code 16 c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 20 June 2019
Resolution: DAPI enrollment provided & sufficent for current employees (new employees expected this summer).
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 May 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit is missing Aspirin. 46CFR184.710&160.041-4(b) code 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 20 June 2019
Resolution: Aspirin was procured and placed onboard.
Engineering › Bilge Water Management System › Pump
Issued 22 May 2018 Resolved
Install UL approved bilge pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 June 2108
Resolved 22 June 2018
Resolution: Proof of installation provided.
Engineering › Bilge Water Management System › Not Installed
Issued 22 May 2018 Resolved
Install high level bilge alarm in steering compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 June 2018
Resolved 11 June 2018
Resolution: Proof of installation provided.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 10 May 2017 Resolved
Vessel’s blower is not interlocked with ignition switch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 11 May 2017
Resolution: Wired Blower to Electronics Breaker. Vessel will not start without Electronics breaker energized.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2017 Resolved
No Guards are installed over Propulsion Engine pullies IAW 465 CFR 177.35-15.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 13 June 2017
Resolution: Protective Guard is installed over engine belts.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 10 May 2017 Resolved
Batteries did not have screening to protect from the accidental crossing of the battery terminals IAW 46 CFR 183.05-20 (c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 13 June 2017
Resolution: Battery Covers installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 May 2017 Resolved
Battery wires are mounted with wing nuts. 46 CFR183.05-20 (a).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 13 June 2017
Resolution: Wing Nuts were replaced.

Ownership record