MAURY USCG vessel records Sign in
← All vessels

TAHOE

TAHOE is a 1950 passenger vessel (inspected). The Coast Guard has recorded 32 inspections since 1999, most recently in May 2025, along with 36 deficiencies.

Records from 1999 to 2025. Most recent: inspection, 29 May 2025.

Built
1950
Last inspected
29 May 2025
Documentation
Valid · documentation file of 10 September 2026
Controls
None recorded without a removal date

Identity

WCZ4828
494313
Flag
UNITED STATES
367423770 (licence lapsed)
Maury page id
psix-494313

Inspections, by type

…with no type recorded2
Years with a record 23 calendar years (1999–2025)
The 32 inspections in the strip above, split by the kind of activity the US Coast Guard recorded. Years with a record are calendar years in which a record exists, not years in service. What Maury does not do.

Coast Guard record current through 13 September 2026, retrieved 18 September 2026 from PSIX. Every field on this page was recorded by the Coast Guard. Records for the Passenger Ship class in Maury's sources begin in 1977.

Documentation record

Registered dimensions (L × B × D)38.6 ft × 9.7 ft × 5.0 ft
Registered tonnagegross 11 / net 8
ITC dimensions (L × B × D)Not recorded
ITC tonnageNot recorded
BuilderMONSON BOAT COMPANY · SEATTLE, WA, UNITED STATES · built 1950
Hull materialWood
PropulsionGasoline Engine
Hull shapeNot recorded
Hull configurationNot recorded
Hailing portZEPHYR COVE, NV
Trade endorsementsCoastwise, unrestricted
DocumentationValid · issued 10 February 2026 · expires 28 February 2027
Service, as the file records itPassenger (Inspected)
Hull formpowered (Maury's inference from propulsion, hull shape, material and length, rule hf-1; not a recorded fact)
Tonnage as PSIX records it11 - Regulatory (Subpart C or D), Gross Ton
8 - Regulatory (Subpart C or D), Net Ton
6 - Dead Weight, Ton
Every line above is a field of the National Vessel Documentation Center's file as served by NOAA Fisheries, dated 10 September 2026, matched to this hull on its Official Number. Registered and ITC measurements are two systems and are never combined. One snapshot is held so far; documentation history begins with the next.

Radio station licence

WCZ4828MMSI 367423770 · expired · voluntarily equipped · granted 1 September 2009, cancelled 9 November 2019
FCC Universal Licensing System ship-station file of 6 September 2026, matched to this hull on its US Official Number. Status and dates are the file’s own. The licensee is not read from the file and is not shown. A lapsed licence’s MMSI is still the number the vessel transmitted under while it was valid.

A report is not offered for this hull: Its record holds only 2 of the seven kinds of material a report is built from: inspections, deficiencies, operational controls, tow-unit appearances, casualty records, dimensions and documentation. That is a statement about the record, not about the vessel. Reports.

Inspection history · 32

29 May 2025 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8146732
12 May 2025 Deficiency Check · Internal Structural Exam · Drydock Exam · Hull Examination
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 8132941
7 August 2024 Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7976664
15 May 2024 DAPI Audit · Deficiency Check · COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7907792
2 August 2023 Administrative Inspection
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7758668
9 May 2023 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7684782
29 April 2022 Internal Structural Exam · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7440832
12 April 2021 Drydock Exam · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 7173916
10 June 2020 Administrative Inspection · Annual Inspection · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6972682
27 March 2020 Administrative Inspection · Drydock Extension
Administrative · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6932257
13 May 2019 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6681518
22 May 2018 Internal Structural Exam · Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6415549
10 May 2017 Administrative Inspection · Annual Inspection · Deficiency Check · Internal Structural Exam
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 6138285
6 June 2016 Administrative Inspection · Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 5893984
7 May 2012 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 4304979
22 July 2011 Deficiency Check · DAPI Audit
Physical examination · USCG Southwest District (dp) · USCG Southwest District (CGD-SW) · Activity 4098820
29 July 2009 COI Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3544861
28 August 2008 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3305639
20 March 2007 Annual Inspection
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 3118183
3 May 2006 Annual Inspection · Deficiency Check
Physical examination · Sector San Francisco · USCG Southwest District (CGD-SW) · Activity 2639875
5 June 2005 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2383710
1 May 2005 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2331518
29 July 2004 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 2134530
29 July 2003 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1905529
21 May 2003 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1779773
17 April 2002 Annual Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1603360
15 October 2001 Type not recorded
No type recorded · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1075591
10 July 2001 Re-Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1457966
20 April 2000 COI Inspection
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1389070
20 April 2000 Hull Examination
Physical examination · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1441653
26 July 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1393202
1 March 1999 Plan Review "T" Boat
Administrative · MSO SAN FRANCISCO BAY · USCG Southwest District (CGD-SW) · Activity 1411939

Deficiency record · 36

09 - Working and Living Conditions › 092 - Working Conditions › Warning notices
Issued 29 May 2025 Resolved
Procedures for checking the proper operation of a flammable vapor detection system must be posted at the primary operating station... A flammable vapor detection system must be operational for 30 seconds prior to engine startup and continue sensing the entire time the engine is running. Procedures are not posted at operating station to wait for green light on flammable vapor monitor indicator before starting engine. 46 CFR 182.480
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 24 June 2025
Resolution: Operator sent photograph of new vapor detection operating procedures to be posted at operating station. Photo uploaded to documents.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 29 May 2025 Resolved
A vessel not required to have a power driven fire pump by § 181.300 must have at least three 9.5 liter (2-1/2 gallon) buckets, with an attached lanyard satisfactory to the cognizant OCMI, placed so as to be easily available during an emergency. The words “FIRE BUCKET” must be stenciled in a contrasting color on each bucket. One of the vessel's 3 fire buckets is more than 2.5 gallons. 46 CFR 181.610
Condition: Placed in Improper Service
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 10 June 2025
Resolution: Operator sent photo of correction to fire bucket. Uploaded to documents.
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 29 May 2025 Resolved
A vessel must carry either a first-aid kit that meets the requirements in 46 CFR 199.175(b)(10) or a kit with equivalent contents and instructions. First aid kit was missing analgesic medication. 46 CFR 184.710
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 12 June 2025
Resolved 30 May 2025
Resolution: Operator sent photo of new bottle of ibuprofen onboard.
02 - Structural Conditions › N/A - No Subsystem › Hull - cracking
Issued 12 May 2025 Resolved
The construction and arrangement of a vessel must allow the safe operation of the vessel in accordance with the terms of its Certificate of Inspection giving consideration to provisions for a seaworthy hull. Vessel’s aft keel/worm shoe area show signs of wear and degradation clean to good wood and treat to the satisfaction of the Marine Inspector. 46 CFR 177.100
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2025
Resolved 23 May 2025
Resolution: Operator sent report detailing satisfactory repairs to the area. Report uploaded to documents tab.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025 Resolved
Cable and wire for power and lighting circuits must: (1) Meet Section 310-13 of NFPA 70 (incorporated by reference; see 46 CFR 175.600);(2) Be listed by Underwriters Laboratories (UL), as UL Boat or UL Marine cable; or(3) Meet § 111.60-1 in subchapter J of this chapter for cable, and § 111.60-11 in subchapter J of this chapter for wire. Speaker cable not rated for marine use was routed throughout the vessel. 46 CFR 183.340(d)
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 5 June 2025
Resolved 30 May 2025
Resolution: Operator sent video of completed marine grade speaker cable installation. Video uploaded to documents.
02 - Structural Conditions › N/A - No Subsystem › Electrical installations in general
Issued 12 May 2025 Resolved
All cable and wire must: Be installed with metal supports spaced not more than 610 millimeters (24 inches) apart, and in such a manner as to avoid chafing and other damage. Vessel was found with plastic supports. 46 CFR 183.340(b)(4)
Condition: Invalid
Action required: 705 - Other - as specified
Due 5 June 2025
Resolved 29 May 2025
Resolution: MI attended vessel verifying appropriate metallic wire supports installed.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 12 May 2025 Resolved
The cognizant OCMI may require that a vessel and its equipment undergo any additional test or inspection deemed reasonable and necessary to determine that the vessel and its equipment are suitable for the service in which they are to be employed. The vessel is required to conduct a post dry dock sea trial with Marine Inspector attendance prior to the carriage of passengers.
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 29 May 2025
Resolution: MI attended vessel for satisfactory sea trial.
07 - Fire Safety › N/A - No Subsystem › Division - decks, bulkheads and penetrations
Issued 15 May 2024 Resolved
Vapor barriers must be provided where insulation of any type is used in spaces where flammable and combustible liquids or vapors are present. Identified cable penetrations in forward engine room bulkhead that were not vapor tight. 46 CFR 177.405(e)
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 15 May 2024
Resolution: Sealed cable penetrations.
07 - Fire Safety › N/A - No Subsystem › Fixed fire extinguishing installation
Issued 15 May 2024 Resolved
Provision must be made for closing all supply duct cowls or scoops and exhaust duct discharge openings for a space protected by a fixed gas extinguishing system. All closure devices must be readily available and mounted in vicinity of vent. No closure devices for vents found. 46 CFR 182.460(l)
Action required: 16 - Rectify deficiencies w/in 14 days
Due 29 May 2024
Resolved 15 May 2024
Resolution: Operator provided photographs of vent closures.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 13 May 2019 Resolved
A power-driven vessel underway shall exhibit: a masthead light; sidelights; and a sternlight. Starboard running light housing is cracked and requires replacement. Inland Nav Rule 23. Code 16
Condition: Damaged By Earlier Event
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 20 June 2019
Resolution: Running light housing replaced.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 13 May 2019 Resolved
Chemical testing of personnel must be conducted as required by this subpart and in accordance with the procedures detailed in 49 CFR part 40. Drug and Alcohol program information required to complete the DAPI audit was not available onboard.46CFR16.201 code 16 c
Condition: Improper Installation
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 20 June 2019
Resolution: DAPI enrollment provided & sufficent for current employees (new employees expected this summer).
09 - Working and Living Conditions › 091 - Living Conditions › Medical Equipment
Issued 13 May 2019 Resolved
A vessel must carry either a first-aid kit approved under approval series 160.041 or a kit with equivalent contents and instructions. First aid kit is missing Aspirin. 46CFR184.710&160.041-4(b) code 16c
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 27 May 2019
Resolved 20 June 2019
Resolution: Aspirin was procured and placed onboard.
Engineering › Bilge Water Management System › Pump
Issued 22 May 2018 Resolved
Install UL approved bilge pumps.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 June 2108
Resolved 22 June 2018
Resolution: Proof of installation provided.
Engineering › Bilge Water Management System › Not Installed
Issued 22 May 2018 Resolved
Install high level bilge alarm in steering compartment.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 12 June 2018
Resolved 11 June 2018
Resolution: Proof of installation provided.
Engineering › Gasoline Engine (propulsion) › Ventilation
Issued 10 May 2017 Resolved
Vessel’s blower is not interlocked with ignition switch.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 May 2017
Resolved 11 May 2017
Resolution: Wired Blower to Electronics Breaker. Vessel will not start without Electronics breaker energized.
Accommodation/Occupational Safety › Occupational Safety › Guards for Exposed Hazards
Issued 10 May 2017 Resolved
No Guards are installed over Propulsion Engine pullies IAW 465 CFR 177.35-15.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 13 June 2017
Resolution: Protective Guard is installed over engine belts.
Accommodation/Occupational Safety › Occupational Safety › Spark Producing Device
Issued 10 May 2017 Resolved
Batteries did not have screening to protect from the accidental crossing of the battery terminals IAW 46 CFR 183.05-20 (c).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 13 June 2017
Resolution: Battery Covers installed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 10 May 2017 Resolved
Battery wires are mounted with wing nuts. 46 CFR183.05-20 (a).
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 10 June 2017
Resolved 13 June 2017
Resolution: Wing Nuts were replaced.
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011 Resolved
Crewmembers not properly trained prior to assuming safety sensitive positions regarding company's drug and alcohol policy in accordance with 46 CFR 16.401.
Due 21 August 2011
Resolved 27 October 2011
Resolution: DER faxed DAPI copy of EAP training roster.
Documentation › Logs/Records › Drug Test Records
Issued 22 July 2011 Resolved
Copy of latest MIS form not available for review as required by 46 CFR part 16.500.
Due 21 August 2011
Resolved 18 August 2011
Resolution: DER faxed DAPI copy of lastest MIS form.
Fire Fighting › Fire Bucket › Lanyard
Issued 28 August 2008 Resolved
Add lanyard to fire buckets in accordance with 46 CFR 181.610.
Due 28 August 2008
Resolved 28 August 2008
Fire Fighting › Fire Bucket › Stenciling
Issued 28 August 2008 Resolved
Properly label fire buckets in accordance with 46 CFR 181.610.
Due 28 August 2008
Resolved 28 August 2008
Electrical › Electrical Distribution System (service) › Fuse
Issued 3 May 2006 Resolved
Install fuse protection on all current carrying conductors (positive) wires at the battery. With exception of the Engine starting circuit.
Due 10 May 2006
Resolved 10 May 2006
Personnel › Certificates/Documents/Licenses › Certificate, CPR Course Completion
Issued 3 May 2006 Resolved
Provide proof of CPR/First aid cards for 50% of crew.
Due 10 June 2006
Resolved 10 June 2006
Construction/Loadline › Hull › Longitudinal Frame
Issued 3 May 2006 Resolved
Make satisfactory repairs to three (3) cracked frames in way of fwd collision bulkhead IAW NVIC 7-95 prior to carrying passengers.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 11 May 2006
Engineering › Bilge Water Management System › Not Operational
Issued 8 June 2005 Resolved
Repair or renew bilge high water alarm sensor and prove proper operation to attending marine inspector.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2005
Electrical › Electrical Distribution System (service) › Conductor
Issued 5 June 2005 Resolved
Remove or properly dead end un-used wire located behind 12 volt distribution panel in cabin area.
Due 30 June 2005
Resolved 6 June 2005
Construction/Loadline › Hull › Hull Plating
Issued 1 May 2005 Resolved
Vessel shall perform underway sea trials with CG inspector in attendance prior to operating with passengers on board in accordance with MSO San Francisco Bay CID memo 6-94.
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 June 2005
Electrical › Electric Supply System (service) › Cable
Issued 29 July 2004 Resolved
Properly dead end loose wire located on engine electrical harness.
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 29 July 2004
Electrical › Electrical Distribution System (service) › Cable
Issued 29 July 2004 Resolved
properly dead end loose wire in back of laod center behind steering station.
Action required: 705 - Other - as specified
Due 29 August 2004
Resolved 29 July 2004
Fire Fighting › Miscellaneous Items
Issued 21 May 2003 Resolved
Provide on board vessel one fire bucket meeting requirements of 46 CFR 181.610. LEGACY COMPONENT DESC: Fire bucket
Due 21 May 2003
Resolved 21 May 2003
Fire Fighting › Portable Dry Chemical Fire Extinguisher › Pressure
Issued 16 April 2002 Resolved
Fire Extinguisher showing out of charge on dial.
Due 16 April 2002
Resolved 16 April 2002
Resolution: New fire extinguisher placed in service.
Fire Fighting › Fixed Gas Fire Extinguishing System › Operating Controls
Issued 16 April 2002 Resolved
System does not secure engine room powered exhaust fan on release.
Due 16 April 2002
Resolved 16 April 2002
Resolution: Engine room exhaust fans properly connected to control of fixed gas extinguishing system
Lifesaving › Hand Flares › Storage
Issued 16 April 2002 Resolved
Flares improperly stored in unmarked container.
Due 16 April 2002
Resolved 16 April 2002
Resolution: Flare storage container marked properly.
Lifesaving › Lifebuoys
Issued 16 April 2002 Resolved
Vessel name improperly marked on lifebouy LEGACY COMPONENT DESC: Markings (ship name/port)
Due 16 April 2002
Resolved 16 April 2002
Resolution: Lifebouy properly marked with vessel name.
Accommodation/Occupational Safety › Medical/First Aid › Medicine Chest
Issued 16 April 2002 Resolved
Aspirin in first aid kit expired.
Due 16 April 2002
Resolved 16 April 2002
Resolution: Aspirin in first aid kit renewed.

Ownership record

The Coast Guard's documentation record for this hull -- the Abstract of Title, with its owners and liens as filed -- is not in PSIX. Ask, and Maury buys it from the National Vessel Documentation Center, files it here with its date, and every reader of this page gets it.