02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 4 May 2021
No resolution recorded
Vessels that operate in fresh water at least six months in every 12 month period since the last dry-dock examination must undergo dry-dock and internal structural examinations not to exceed five years.
The Levy's dry-dock interval expired on 30April2021. Prior to carrying passengers this vessel must be dry-docked for credit dry-docking and internal structural examinations. Note, the next five year cycle will be calculated from the 30April2021 due date.
Contact SECTOR New Orleans dispatcher to schedule an inspection for this vessel. [email withheld] or phone [phone withheld].
Action required: 701 - Prior to carriage of passengers/cargo
Due 30 August 2021 — due date passed with no resolution recorded
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Gauges, thermometers, etc
Issued 25 February 2021
Resolved
46CFR62.25-1(a)-Vital systems that are automatically or remotely controlled must be provided with (4) Instrumentation to monitor system parameters necessary for the safe and effective operation of the system. STBD main propulsion engine J/W alarm sensor was relocated to the cold side of the system. This prevents proper monitoring of high engine temperatures. Relocate sensor to location intended by manufacturer.
Condition: Improper Installation
Action required: 60 - Rectify deficiencies prior to movement
Due 17 March 2021
Resolved 4 March 2021
Resolution: Received tech report that stated the heat probe sensor was replaced on the hot side of the J/W system. All sat.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 25 February 2021
Resolved
46CFR11.05-3 -An electric apparatus must be designed, constructed, and installed to prevent any person from accidentally contacting energized parts. A ground was identified on ground detection panel located near emergency generator. Identify location and make appropriate repairs isolate ground.
Condition: Damaged By Earlier Event
Action required: 60 - Rectify deficiencies prior to movement
Due 17 March 2021
Resolved 4 March 2021
Resolution: Received tech report that found the ground fault on neutral, removed and insulated. All sat.
11 - Life Saving Appliances › N/A - No Subsystem › Lifeboats
Issued 25 February 2021
No resolution recorded
46CFR199.153(k)-If a survival craft is recovered by any means using power, including a portable power source, safety devices must be provided that automatically cut off power before the davit arms or falls reach stops in order to avoid overstressing the falls or davits.Install safety device (anti 2-block device) to rescue boat davit winch.
Condition: Improper Installation
Action required: 50 - Rectify deficiencies w/in 30 days
Due 17 March 2021 — due date passed with no resolution recorded
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 25 February 2021
Resolved
46CFR199.190- Operational readiness. Before the vessel leaves port and at all times during the voyage, each lifesaving appliance must be in working order and ready for immediate use. (b) The manufacturers instruction for onboard maintenance of lifesaving appliances must be on board the vessel. Lifesaving maintenance was last conducted in NOV2020. Maintenance must be conducted IAW CFR and Manufacturers recommendations including intervals.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 17 March 2021
Resolved 3 March 2021
Resolution: Onboard representatives created a maintenance plan in their online management program.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 25 February 2021
Resolved
46CFR199.70(a)- Each vessel must carry lifebuoys approved under approval series 160.150. Port bridge wing buoy had no approval markings. Replace with approved buoys.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 17 March 2021
Resolved 3 March 2021
Resolution: Vessel representative replaced lifebouy with a new approved lifebuoy.
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 1 July 2020
Resolved
During todays In Service Inspection, the engineering logs were examined and found to be deficient, there is a problem with Battery weekly checks not being completed which lead to the EDG failure on 23Jun2020. These weekly checks that were last done on 13Jun2020 should have been done again on 20Jun2020 and were not completed until the day after the EDG failure. The EDG failure could have been prevented had the weekly battery checks been completed when required by your logs.
This problem must be investigated by your staff to determine the root cause for this failure in the PMS schedule and the lack of attention by the engineers involved. A written policy that corrects this issue which must include detailed training for the engineers on proper watch standing, log entries and PMS completion. This all must be completed within 14 days and prior to getting the vessel underway and submitted to USCG SECTOR New Orleans.
Condition: Improper/Lack of Maintenance
Action required: 60 - Rectify deficiencies prior to movement
Due 15 July 2020
Resolved 30 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 June 2020
Resolved
Each generator must meet applicable requirements for construction and testing.
Action required: 60 - Rectify deficiencies prior to movement
Due 28 June 2020
Resolved 28 June 2020
Resolution: Deficiency is cleared and rewritten to reflect further issues found during the in-service inspeciton.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 June 2020
Resolved
For the power failure that occured on 23Jun20 with the Port SSDG. Current tech Report from Coastwide Electric is not satisfactory. Provide a detailed root cause analysis for this power loss that determines exactly what happened and the steps to taken to correct the issue. An "unknown answer" is not acceptable. Provide this analysis prior to getting this vessel underway from its current location. This analysis must include all thest conducted to determine the root cause of the failure.
Action required: 60 - Rectify deficiencies prior to movement
Due 13 July 2020
Resolved 30 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 June 2020
Resolved
For the power failure that occured on 23Jun20 with the loss of the Port SSDG and the failure of the EDG to start automatically and provide power. Provide a root cause analysis for the issue and document the corrective action taken to prevent this from happening again. Provide basic engineering check off sheets that deals with starting and checking of the EDG prior to getting the vessel underway. This analysis must include all tests conducted to determine the root cause of the failure. An "Unknown answer" is not acceptable. Must be completed prior to moving the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 13 July 2020
Resolved 30 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 June 2020
Resolved
For the power loss that occured on 27Jun20 with the Port SSGD, provide a root cause analysis that determines why the SSDG failed. This analysis must include all tests conducted to determine the root cause of the failure. an "Unknown answer" is not acceptable. Must be completed prior to moving the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 13 July 2020
Resolved 30 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 June 2020
Resolved
For the power loss that occured on 27Jun20 with the Port SSDG, provide a root cause analysis to determine why the SSDG could not be restarted or even turned over once the vessel returned to the dock. This analysis must include all tests conducted to determine the root cause of the failure. an "Unknown answer" is not acceptable. Must be completed prior to moving the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 13 July 2020
Resolved 30 November 2020
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 28 June 2020
Resolved
For the power loss that occured on 27Jun20 with the SSDG, provide a root cause analysis that determines why the Port SSDG could not be started on 28Jun20 during the Coast Guard visit. This analysis must include all tests conducted to determine the root cause of the failure. An "Unknown answer" is not acceptable. Must be completed prior to moving the vessel.
Action required: 60 - Rectify deficiencies prior to movement
Due 13 July 2020
Resolved 30 November 2020
04 - Emergency Systems › N/A - No Subsystem › Emergency source of power - Emergency generator
Issued 24 March 2020
Resolved
During testing of the emergency generator, E-generator would not automatically start during loss of power. Provide technician’s report attesting to proper operation of emergency generator and provide cause of inoperable generator.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 March 2020
Resolution: New battery installed and testing of the e-generator with a load was verified by attending USCG MI.
15 - Safety Management Systems (ISM) › N/A - No Subsystem › Reports of non-conf., accidents & hazardous occur.
Issued 1 January 2020
Resolved
Any casualty or accident involving any vessel other than a public vessel that occurs upon the navigable waters of the United States, its territories or possessions involves any United States vessel wherever such casualty or accident occurs. CAPN NEVILLE LEVY was involved in an allision with the MARGARET LAB and failed to report this to CG Sector Office within a timely manner. CAPN NEVILLE LEVY shall update the training plans regarding the reporting of a Marine Casualty within 7 days.
Action required: 705 - Other - as specified
Due 8 January 2020
Resolved 8 January 2020
Resolution: Company training performed, USCG questioned and received satisfactory responses to questions regarding marine casualty reporting.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 November 2019
Resolved
A survey, either general or partial, according to the circumstances shall be made every time an accident occurs or defect is discovered which affects the safety of the vessel. The survey shall be such to insure that the necessary repairs or renewals have been sufficiently made, and that the vessel complies in all respects with the regulations in this subchapter. Vessel is not permitted to operate in any capacity until repairs are made to the hydraulic piping system which operates the vehicle ramps, and the system is sufficiently tested to the satisfaction of a CG Marine Inspector.
46 CFR 71.40
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2020
Resolution: Witnessed satisfactory operation of vehicle ramps.
02 - Structural Conditions › N/A - No Subsystem › Other (Structural condition)
Issued 19 November 2019
Resolved
All tubing and pipe materials shall be suitable for handling hydraulic fluid. Discovered significant leak on aft starboard hydraulic system controlling vehicle ramps. Leak was located in #5 stbd ballast tank on threaded piping connection to gear housing for hydraulic ramps. Replace affected piping to satisfaction of CG Marine Inspector, flush all hydraulic piping, hydro-statically test lines to working pressure, and make all hydraulic lines available for inspection.
46 CFR 70-20.1
46 CFR 58.30-15(a)
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2020
Resolution: Witnessed satisfactory operation of vehicle ramps.
09 - Working and Living Conditions › 092 - Working Conditions › Protection machinery
Issued 19 November 2019
Resolved
On vehicular ferries, suitable chains, cables, or other barriers shall be installed at the ends of the vehicle runways. Discovered no locking mechanism on ramps. Install mechanical permanent means to secure all vehicle ramps on board the vessel to the satisfaction of USCG Marine Inspector.
46 CFR 72.40-15(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2020
Resolution: Verified use of ramp securing chains.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 19 November 2019
Resolved
All tubing and pipe materials shall be suitable for handling hydraulic fluid. Discovered hydraulic leak at valve and fitting for port aft ramp system. Make repairs to satisfaction of USCG Marine Inspector.
46 CFR 70-20.1
46 CFR 58.30-15(a)
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Resolved 8 February 2020
Resolution: Witnessed satisfactory operation of vehicle ramps.
02 - Structural Conditions › N/A - No Subsystem › Stability/strength/loading information and instruments
Issued 5 November 2019
Resolved
After loading and prior to departure and at all other times necessary to assure the safety of the vessel, the master shall determine that the vessel complies with all applicable stability requirements in the vessel's trim and stability book, stability letter, Certificate of Inspection, and Load Line Certificate, as the case may be, and then enter an attestation statement of the verification in the log book. The vessel may not depart until it is in compliance with these requirements.
Following the discovery of engineering log entries surrounding steering space de-watering, Inspectors observed rudder posts while operating. Observed substantial water ingress into steering space, significantly affecting the vessel's stability.
Prior to vessel operating, properly de-water space and complete repairs to satisfaction of attending CG Marine Inspector.
46 CFR 78.17-22(a)
Action required: 60 - Rectify deficiencies prior to movement
Resolved 6 November 2019
Resolution: Space properly dewatered, witnessed satisfactory testing of rudder posts underway, leaks corrected.
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 24 October 2019
Resolved
Engine room fire dampers on stack not in operational condition. Safety pin is extremely difficult to remove and dampers do not fully close. Correct to satisfaction of CG Marine Inspector.
Action required: 60 - Rectify deficiencies prior to movement
Resolved 24 October 2019
Resolution: Operator cleaned and conditioned dampers. Verified proper operation. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 October 2019
Resolved
All tubing and pipe materials shall be suitable for handling hydraulic fluid used. Discovered significant leaks throughout Bow Thruster system; oil accumulating in bilge, on deck plates, and in catch basin of shaft tube. Prior to operating bow thruster, properly remove standing hydraulic fluid and correct all leaks to satisfaction of CG Marine Inspector. Provide repair plan within 7 days.
46 CFR 70.20-1
46 CFR 58.30-15(a)
Action required: 705 - Other - as specified
Due 6 February 2020
Resolved 8 February 2020
Resolution: Witnessed satisfactory operation of bow thruster unit following repairs to multiple leaks and replacement of oil pump and seals.
07 - Fire Safety › N/A - No Subsystem › Oil accumulation in engine room
Issued 24 October 2019
Resolved
Fire hazards shall be minimized insofar as is reasonable and practicable. Oil found accumulating in several areas of the engine room. Within seven days, properly remove standing oil and correct excessive oil leaks.
46 CFR 72.03-5
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Bilges free and clear of standing oil.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 24 October 2019
Resolved
Approved portable fire extinguishers must be installed in accordance with 46 CFR Table 76.50-10(a). Portable extinguisher 15 was found to have a damaged bracket. Within seven days, correct damaged bracket to satisfaction of CG Marine Inspector.
46 CFR 76.50-10
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Bracket repaired/remounted.
99 - Other › N/A - No Subsystem › Other (Safety in general)
Issued 24 October 2019
Resolved
The Vessel Security Officer must ensure adequate security training for vessel personnel. Vessel crew found to have limited knowledge on MARSEC levels and how to respond to security incidents. Within seven days, perform satisfactory vessel security drill to satisfaction of CG Marine Inspector.
33 CFR 104.215(e)(7)
Action required: 705 - Other - as specified
Resolved 5 November 2019
Resolution: Operator conducted satisfactory training as evident in drills and discussion in presence of Inspectors.
09 - Working and Living Conditions › 092 - Working Conditions › Electrical
Issued 24 October 2019
Resolved
Each device must have a nameplate showing the device's function. Main switchboard is missing labels on multiple breakers. Within seven days, correct to satisfaction of CG Marine Inspector.
46 CFR 111.30-15(a)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Labels placed on switchboard breakers.
09 - Working and Living Conditions › 092 - Working Conditions › Safe means of access
Issued 24 October 2019
Resolved
All doors shall be capable of operation from either side by 1 person. STBD Pilothouse bridge wing weather-tight door improperly functioning. Within seven days, correct to satisfaction of CG Marine Inspector.
46 CFR 72.05-25(a)(1)
Action required: 705 - Other - as specified
Resolved 5 November 2019
Resolution: Door mechanism replaced and tested. Opens from inside for egress, locks from outside for security. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Operation of machinery
Issued 24 October 2019
Resolved
All tubing and pipe materials shall be suitable for handling hydraulic fluid used. Discovered hydraulic leak at valve and fittings for STBD AFT ramp system. Provide repair plan within 7 days, correct to satisfaction of USCG Marine Inspector.
46 CFR 58.30-5(b)
Action required: 16 - Rectify deficiencies w/in 14 days
Resolved 1 November 2019
Resolution: STBD aft ramp hydraulic lines/valve replaced. No leaks visibile.
11 - Life Saving Appliances › N/A - No Subsystem › Maintenance of Life Saving Appliances
Issued 24 October 2019
Resolved
Storage batteries for emergency lighting and power systems shall be tested at least once each 6-month period that the vessel is navigated to demonstrate the ability of the storage battery to supply the emergency loads for the period of time specified in table 112.05-5(a) of this chapter. Discovered corrosion on battery terminals and immediate wiring for the GE alarm battery system. Within seven days, correct to satisfaction of CG Marine Inspector.
46 CFR 78.17-45(c)
Action required: 705 - Other - as specified
Resolved 5 November 2019
Resolution: Corroded wiring replaced, system energized. All SAT.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 October 2019
Resolved
It shall be the duty of the chief engineer when assuming charge of the boilers and machinery of a vessel to examine them thoroughly. If any parts thereof are in bad condition, the fact shall immediately be reported to the master, owner or agent, and the Officer in Charge, Marine Inspection. Discovered non-functioning Jacket Water temperature gauge on #2 Generator. Within seven days, correct to satisfaction of CG Marine Inspector.
46 CFR 78.17-30
Action required: 705 - Other - as specified
Resolved 24 March 2020
Resolution: Witnessed satisfactory testing during COI (AN# 6930475).
04 - Emergency Systems › N/A - No Subsystem › Emergency, lighting, batteries and switches
Issued 24 October 2019
Resolved
It shall be the duty of the master to see that the emergency lighting and power systems are operated and inspected at least once in each week that the vessel is navigated to be assured that the system is in proper operating condition. Discovered non-functioning Emergency Light on STBD side main deck. Correct within 7 days to satisfaction of CG Marine Inspector.
46 CFR 78.17-45(a)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Light bulbs and ballast replaced.
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 24 October 2019
Resolved
Each lifesaving appliance must be in working order and ready for immediate use. Cloth line holding tether lines to in a bundle on Life Floats have failed, correct within 7 days to satisfaction of CG Marine Inspector.
46 CFR 199.190(a)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Lines bundled to satisfaction of inspector.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Propulsion main engine
Issued 24 October 2019
Resolved
All engine installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this subchapter. Discovered fuel leak at supply valve for PORT Main Diesel Engine. Correct within 7 days to satisfaction of CG Marine Inspector.
46 CFR 58.10-5(a)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Valve and hoses repaired. No leaks present.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Auxiliary engine
Issued 24 October 2019
Resolved
All engine installations shall be of marine type engines suitable for the intended service, designed and constructed in conformance with the requirements of this Subchapter. Discovered oil leak at sending unit for STBD Generator, correct to satisfaction of CG Marine Inspector. Within seven days, correct to satisfaction of CG Marine Inspector.
46 CFR 58.10-5(a)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Leak repaired, all SAT.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2019
Resolved
Each lifesaving appliance must be in working order and ready for immediate use. Discovered 1 non-serviceable adult life jacket on 2nd deck, replace within 7 days to satisfaction of CG Marine Inspector.
46 CFR 199.190(a)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Life Jakcet replaced with new.
07 - Fire Safety › N/A - No Subsystem › Other (fire safety)
Issued 24 October 2019
Resolved
Drills must, as far as practicable, be conducted as if there were an actual emergency. Discovered inconsistency with Fire Drill training witnessed compared to frequency of documentation. Conduct adequate fire drill training to satisfaction of CG Marine Inspector.
46 CFR 199.180(c)
Action required: 705 - Other - as specified
Resolved 5 November 2019
Resolution: Operators conducted adequate training, displayed in drills conducted in presence of Inspectors.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2019
Resolved
The chief engineer shall be responsible only for the sanitary condition of the engineering department. Discovered leaking chemicals on Sewage tank chemical feed tank. Within seven days, correct to satisfaction of CG Marine Inspector.
46 CFR 78.17-25(a)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Repaired fiitings and leaks.
10 - Safety of Navigation › N/A - No Subsystem › Lights, shapes, sound-signals
Issued 24 October 2019
Resolved
Each self-propelled vessel must have duplicate light sources for the side, masthead, and stern lights. Discovered that upon testing anchor lights at operating station, aft anchor light did not work and alarm sounded at operating station indicating failure. Correct within 7 days to satisfaction of CG Marine Inspector.
46 CFR 111.75-17
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Repairs conducted, anchor lights operational with no alarms.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 October 2019
Resolved
Each lifesaving appliance must be in working order and ready for immediate use. Found rescue boat bow light containing port and starboard navigation lights broken. Correct within 7 days to satisfaction of CG Marine Inspector.
46 CFR 199.190(a)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Light repaired and spare on hand if issues arise.
11 - Life Saving Appliances › N/A - No Subsystem › Rescue boats
Issued 24 October 2019
Resolved
Rescue boats must be stowed in a position suitable for launching and recovery. MI discovered exposed wire rope on rescue boat causing a safety hazard for personnel when launching rescue boat. Within seven days, provide suitable chafing gear on wire rope to the satisfaction of CG Marine Inspector.
46 CFR 199.140(a)(2)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Added chaffing gear and removed exposed wire ends.
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 24 October 2019
Resolved
The life jacket stowage positions must be marked with the words “ LIFEJACKETS” or “CHILD LIFEJACKETS” as appropriate, or with the appropriate symbol from IMO Resolution A.760(18). Discovered improper life jacket stowage label for 15 child size life jackets on second deck passenger seating area. Correct within 7 days to satisfaction of CG Marine Inspector.
46 CFR 199.70(b)(2)(iii)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Label corrected.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 24 October 2019
Resolved
Each lifebuoy stowage position must be marked with either the words “LIFEBUOY” or “LIFE BUOY”, or with the appropriate symbol from IMO Resolution A.760(18). Each lifebuoy must be marked in block capital letters with the name of the vessel and the name of the port required to be marked on the stern of the vessel. Found bridge wing life buoys missing required markings and reflective tape, correct within 7 days to satisfaction of CG Marine Inspector.
46 CFR 199.70(a)(1)(iii) and (2)
Action required: 705 - Other - as specified
Resolved 1 November 2019
Resolution: Markings corrected.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2019
Resolved
The installation of all systems of a marine engineering nature, together with the details of design, construction, and installation, shall be in accordance with the requirements of Subchapter F (Marine Engineering) of this chapter. The following plans must be submitted to the Coast Guard for approval in accordance with §50.20-5 and §50.20-10 of this chapter: Design Verification and Periodic Safety test procedures described in subpart 61.40 of this chapter. Update and resubmit PSTP's for local OCMI approval within 60 days.
46 CFR 77.03-1(a)
46 CFR 62.20-1(a)(7)
Action required: 705 - Other - as specified
Resolved 9 December 2019
Resolution: Witnessed satisfactory testing of Maine Engine Low L/O shutdowns and Main Engine Overrides. PSTP revisions reviewed and submitted to Command for signature.
13 - Propulsion and Auxiliary Machinery › N/A - No Subsystem › Other (machinery)
Issued 24 October 2019
Resolved
In all ventilation systems, manually operated dampers or other suitable means shall be provided in accessible locations, outside the spaces served by the system, for shutting off the passage of air in the event of fire. Engine room ventilation dampers should be regularly maintained, and reflected in vessel's Preventative Maintenance System. Add Fire Dampers to vessel's Preventitive Maintenance program within 60 days.
Action required: 705 - Other - as specified
Resolved 2 December 2019
Resolution: Reviewed PSTP revisions and maintenance plan. Vessel added fire dampers to maintenance schedule.
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 July 2019
Resolved
2)[name withheld] for the days log entry the day after 09Jul2019 and before 14Jul2019 needs to date this page of the ships log. Currently no date is written for this log entry.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 19 July 2019
Resolved 1 August 2019
01 - Certificates & Documentation › 013 - Documents › Log-books/compulsory entries
Issued 18 July 2019
Resolved
3)The pilot house log book is missing the weekly fire drills as required by the log. Last drill logged was on 06Jul2019 and today’s inspection date is 18Jul2019. Correct by the end of this inspection today. Today’s Coast Guard Drill has corrected this missing drills. Deficiency issued and cleared the same day.
Condition: Invalid
Action required: 10 - Deficiency Rectified
Due 19 July 2019
Resolved 1 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Buoyant apparatus
Issued 18 July 2019
Resolved
4)Grab lines on the life floats need to be bundled back up to the correct position, currently there are some loose and getting tangled. Correct by 19Jul2019.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 July 2019
Resolved 1 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2019
Resolved
5)2nd deck outside life jacket locker has an A/C drain line that drains back into the life jacket locker. Repair/Modify this line so that it does not drain into the locker. Complete by 25Jul2019.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 July 2019
Resolved 1 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire-dampers
Issued 18 July 2019
Resolved
6)The access to the stack fire dampers is hindered by a sticking access gate latch that allows access to the area. You can gain access by climbing over the gate but the gate does require repairs. Complete by 25Jul2019.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 July 2019
Resolved 1 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2019
Resolved
7)Located inside the second deck, the life jacket storage in the overheads have had their quantity numbers painted over. These are required to be re-stenciled with the correct numbers. Complete by 25Jul2019.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 19 July 2019
Resolved 1 August 2019
11 - Life Saving Appliances › N/A - No Subsystem › Lifejackets incl. provision and disposition
Issued 18 July 2019
Resolved
8)There are some old life jacket donning instruction placards located throughout the vessel, these placards do not apply to the current life jackets on board the vessel. Remove the old placards and install current applicable placards. Complete by 25Jul2019.
Condition: Placed in Improper Service
Action required: 10 - Deficiency Rectified
Due 19 July 2019
Resolved 1 August 2019
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 18 July 2019
Resolved
9)Some fire extinguishers numbers do not match the numbers on the blkhds, check all extinguishers and correct the numbering system on board. Complete by 23Jul2019.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 19 July 2019
Resolved 23 March 2020
Resolution: Item's corrected and verified by MI.
11 - Life Saving Appliances › N/A - No Subsystem › Lifebuoys incl. provision and disposition
Issued 18 July 2019
Resolved
10)The following life jacket lockers had life jacket failures.
Upper Deck 3 Adult and 1 child failed.
2nd Deck STBD 9 adult failed.
2nd deck port 7 adult and 1 child failed.
For a total of 19 adult and 2 child.
Failures were due to rotten fabric and rotten floatation material. Correct by 18Jul2019.
Condition: Improper/Lack of Maintenance
Action required: 10 - Deficiency Rectified
Due 18 July 2019
Resolved 18 July 2019
08 - Alarms › N/A - No Subsystem › Machinery controls alarm
Issued 3 April 2019
Resolved
Prior to getting the vessel U/W with passengers corrections are required to be made to the periodic test procedures as discussed with the Chief Engineer and Port engineer. Also there are various eng. alarms that either show no alarm light and or don't provide same alarms on each alarm repeater panel. Correction required within 30 days. 46CFR's 61.40-6 and 61.40-10.
Condition: Placed in Improper Service
Action required: 50 - Rectify deficiencies w/in 30 days
Due 3 May 2019
Resolved 9 April 2019
Resolution: Alarm panel repair, loose wires, tested all alarms related to problem, all satisfactory.
07 - Fire Safety › N/A - No Subsystem › Fire fighting equipment and appliances
Issued 31 October 2018
Resolved
Condition: Improper/Lack of Maintenance
Action required: 16 - Rectify deficiencies w/in 14 days
Due 14 November 2018
Resolved 13 November 2018
Resolution: Verified and tested proper repair of the burst sprinkler pipe.
Electrical › Lighting (emergency) › Lighting Fixture
Issued 9 April 2018
Resolved
Emergency lighting is nonoperational in 5 fixtures on 02 deck (inside) and in 1 fixture on 02 deck aft at life jacket station.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2018
Resolved 11 April 2018
Resolution: Replaced light bulbs.
Construction/Loadline › Structures › Ventilators
Issued 9 April 2018
Resolved
On 03 deck, flex coupling on port side gooseneck vent is torn.
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 2 May 2018
Resolution: Flex coupling repaired.
Communications › Public Address System › Announcing Station
Issued 9 April 2018
Resolved
PA system non-operational on 01 deck at both bow and stern.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2018
Resolved 2 May 2018
Resolution: Call back system repaired.
Operations/Management › Navigation Safety › Navigation Underway, General
Issued 9 April 2018
Resolved
Bridge bow thruster indicator non-operational.
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 2 May 2018
Resolution: Indicator repaired.
Electrical › Lighting (service) › Lighting Fixture
Issued 9 April 2018
Resolved
Alarm panel light bulb out on bridge.
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 2 May 2018
Resolution: Repaired.
Navigation › Piloting/Steering › Maneuverability Rating
Issued 9 April 2018
Resolved
Bridge port tachometer non-operational.
Action required: 705 - Other - as specified
Due 9 April 2018
Resolved 2 May 2018
Resolution: Demonstrated redundancy for tachometer reading on bridge. Originally issued as prior to movement; now extended to 09 May 2018. Tach repaired completely 02May18.
Electrical › Electrical Distribution System (service) › Wiring
Issued 9 April 2018
Resolved
2 permanent extension cords found (1 on bridge; 1 at air receiver in E/R). Determine needs and repair as necessary.
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 2 May 2018
Resolution: Extension Chords removed.
Electrical › Electric Supply System (service) › Battery Installation
Issued 9 April 2018
Resolved
Battery box for AIS behind bridge had 2 dead end wires and 2 live wires that were chaffed and cracked. Remove and replace.
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 11 April 2018
Resolution: Removed and renewed wires.
Accommodation/Occupational Safety › Occupational Safety › Tripping/Falling Hazard
Issued 9 April 2018
Resolved
Cables wire tied to ladder above bridge, impeding ladder access.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2018
Resolved 11 April 2018
Resolution: Removed from ladder-way; installed correctly.
Construction/Loadline › Hull › Side Shell
Issued 9 April 2018
Resolved
Vertical stanchion on 01 deck (port aft) hydraulic ramp station: bottom is wasted at attachment to deck.
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 11 April 2018
Resolution: Cropped and renewed.
Electrical › Electric Supply System (service) › Cable
Issued 9 April 2018
Resolved
3" gash in shore tie cable near connection on vessel.
Action required: 705 - Other - as specified
Due 9 May 2018
Resolved 11 April 2018
Resolution: Verified cable intact and used heat shrink to protect area from further damage.
Electrical › Electrical Distribution System (service) › Junction Box
Issued 9 April 2018
Resolved
Electrical junction box (forward starboard) identified as containing PA wiring and is missing a cover.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2018
Resolved 11 April 2018
Resolution: Renewed junction box.
Fire Fighting › Ventilation Systems › Operating Controls
Issued 9 April 2018
Resolved
Ventilation shutdown for engine room appears to be jury-rigged.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2018
Resolved 11 April 2018
Resolution: Replaced.
Fire Fighting › Fixed Pressure Water-Spraying Fire Extinguishing System › Nozzles
Issued 9 April 2018
Resolved
Sprinkler system unable to provide adequate deck coverage.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2018
Resolved 11 April 2018
Resolution: Serviced all sprinkler heads.
Engineering › Compressed Air System (start air) › Compressor
Issued 9 April 2018
Resolved
#2 air compressor does not energize.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2018
Resolved 11 April 2018
Resolution: Replaced liner.
Construction/Loadline › Penetrations › Gasket
Issued 9 April 2018
Resolved
Bow thruster hatch not installed correctly, compromising watertight integrity.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2018
Resolved 11 April 2018
Resolution: Cleaned out silicone sealant and installed new bolts.
Electrical › Electric Generation Source (emergency) › Generator
Issued 9 April 2018
Resolved
Belt on emergency generator starting to fray.
Action required: 60 - Rectify deficiencies prior to movement
Due 9 April 2018
Resolved 11 April 2018
Resolution: Belt replaced.
Operations/Management › Drills/Instruction › Man Overboard Recovery
Issued 22 December 2017
Resolved
Demonstrate a proper man overboard drill prior to loading passengers.
Condition: Placed in Improper Service
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2017
Resolved 22 December 2017
Resolution: Conducted man over board training.
Fire Fighting › Fixed CO2 Fire Extinguishing System › Operating Instructions
Issued 22 December 2017
Resolved
Properly label and install CO2 activation instruction for the engine room CO2 system.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 12 January 2018
Resolved 2 March 2018
Resolution: Labels installed.
Fire Fighting › Structural - A Class Divisions › Fire Doors
Issued 22 December 2017
Resolved
Replace both forward and aft main deck engine room doors with approved self closing fire doors or provide proof that doors should not be self closing.
Condition: Improper Installation
Action required: 705 - Other - as specified
Due 21 January 2018
Resolved 2 March 2018
Resolution: self closing mechanisms installed and tested; all sat.
Operations/Management › Drills/Instruction › Fire
Issued 22 December 2017
Resolved
Conduct training for all crew members on basic fire fighting systems onboard.
Condition: Improper/Lack of Maintenance
Action required: 701 - Prior to carriage of passengers/cargo
Due 22 December 2017
Resolved 22 December 2017
Resolution: Fire fighting training conducted.
Engineering › Engine Controls (Electric/Electronic) › Circuit Board
Issued 21 September 2017
Resolved
Received report of loss of power on the port engine. Provide proof of proper operation prior to movement.
Condition: Damaged By Earlier Event
Action required: 17 - Rectify deficiencies prior to departure
Resolved 21 September 2017
Resolution: Received report indicating a faulty jumper in the ECM, replaced, tested; all sat.
Engineering › Steering Gear System › Rudder Stock
Issued 15 June 2017
Resolved
Currently the vessel is having problems with the flanking rudder sticking at hard port, the vessel is currently out of service and is restricted to its dock and not permitted to move or carry passengers until the problem has been identified and corrected. Once problem has been identified, contact the Coast Guard to schedule an inspection of the problem found and to the repairs to the problem,
Condition: Invalid
Action required: 701 - Prior to carriage of passengers/cargo
Due 12 July 2017
Resolved 11 August 2017
Resolution: Witnessed satisfactory steering tests for both the regular and flanking rudders.
Engineering › Fuel Oil Storage/Transfer System › Piping
Issued 26 April 2017
Resolved
1.Complete proper and permanent repairs to the EDG fuel system above the F/O tank which is still leaking after a previous attempt to repair. Make repairs to this leak and then pressure test the fuel lines in the EDG room to check the repairs. Repairs and testing to be completed to the satisfaction of the attending USCG Marine Inspector.Pictures were sent with this 835 requirement to show the leak
Condition: Improper Installation
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 May 2017
Resolved 6 June 2017
Resolution: Routed Tank vent to outside with containment.
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 10 March 2017
Resolved
Gas free the #5 ballast tank and make ready for coast guard examination prior to the moving of the vessel. A company rep. is required for the internal examination.
Condition: Damaged By Earlier Event
Due 10 March 2017
Resolved 10 March 2017
Resolution: #5 ballast tank was gas freed.
Construction/Loadline › Hull › Hull Plating
Issued 10 March 2017
Resolved
The vessel will be required to be dry docked for an internal and external exam, all spaces will need to have a gas free certificate and made safe for entry. A company rep. is required for these internal and external examinations.
Condition: Damaged By Earlier Event
Action required: 701 - Prior to carriage of passengers/cargo
Due 10 April 2017
Resolved 6 June 2017
Construction/Loadline › Hull › Bottom Plating
Issued 10 March 2017
Resolved
A P.E. (Naval Arch) report will be required that notes the damage and any and all recommended repairs that will be required to be completed.
Condition: Damaged By Earlier Event
Action required: 705 - Other - as specified
Due 10 April 2017
Resolved 6 June 2017
Construction/Loadline › Hull › Bottom Plating
Issued 10 March 2017
Resolved
A complete repair proposal will be required for all the damaged areas on the vessel and the repairs that are required must be completed, examined and be tested prior to the vessel being placed back into service.
Condition: Damaged By Earlier Event
Due 10 April 2017
Resolved 6 June 2017
Accommodation/Occupational Safety › Occupational Safety › Welding/Hot Work
Issued 10 March 2017
Resolved
Complete repairs to holed main deck in way of stairwell leading to 2nd deck and make ready for inspection
Condition: Improper/Lack of Maintenance
Due 10 April 2017
Resolved 6 June 2017
Engineering › Diesel Engine (auxiliary) › Crankcase
Issued 9 March 2017
Resolved
Complete proper and permanent repairs to the EDG so that the current oil leak problem is solved. Provide a sort time frame on accomplishing this repair. Until repaired constant watch on tis engine to keep the leaking oil wiped up. Apparently the engine does not have to be running to leak.
Condition: Improper/Lack of Maintenance
Action required: 705 - Other - as specified
Due 1 May 2017
Resolved 6 June 2017
Resolution: New Oil Pan Installed.
Engineering › Fuel Oil Storage/Transfer System › Vent Pipe
Issued 9 March 2017
Resolved
IAW the referenced Cite, 46CFR 56.50-85, make sure the tank piping is in compliance and provide a plan to correct the problem of overfilling the EDG fuel tank when using the F/O transfer pump and to comply with the provisions of the Referenced cite. Especially parts (a) 4 and (a) 11, this must be completed -prior to carrying passengers and to the satisfaction of the attending marine inspector.
Condition: Design Flaw
Action required: 705 - Other - as specified
Due 15 May 2017
Resolved 6 June 2017